• Title/Summary/Keyword: Appliance System

Search Result 447, Processing Time 0.022 seconds

Robust Safety Circuits for DC Powered Home Appliances in Transient State

  • Ahn, Jung-Hoon;Kim, Yun-Sung;Lee, Byoung-Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1967-1977
    • /
    • 2014
  • In this paper, for the development of a safe and reliable DC home appliance suitable for DC home power supply system, we classified a number of inherent problems with help of the comparative analysis of existing AC and new DC home appliance. Several new technical problems of DC home appliances are mainly linked to the DC transient state. Among them, this paper concentrates on start-up inrush current problem, uni-polarity problem, and heavy DC load control problem. And to address these problems, we herein present an implementation of robust safety circuits for DC home appliances. Specifically, we investigate several multi-circuit countermeasures and select the best among them through comparative evaluation, based on theoretical, simulational, and experimental results.

A Study on the Insulation Methods of 220V Home Appliances and Wiring Devices (승압에 따르는 220V용 전기기기의 절연방식 결정에 관한 연구)

  • Sung Won Rhee
    • 전기의세계
    • /
    • v.20 no.4
    • /
    • pp.5-11
    • /
    • 1971
  • This is a study on the insulation methods of home appliances and wiring devices proper to the new electric distribution system, primary side is 22.9/13.2KV, 3 phase 4 wire multigrounding system and secondary side is 380/220V, 3 phase 4 wire common neutral system. 1800V is determined as the electrical insulation voltage of the functional insulation because the abnormal voltage rise of the neutral line is 1300V. In the case of the functional insulation faults, the following safety methods will be suggested to protect the accidental faults: (a) class I appliance (accessible metal part is earthed), (b) class II appliance (doublly insulated), (c) class III appliance (operates at low voltage source). The mechanisms of the wiring devices are not improved to guarantee for the harmful electric shock but also the electrical insulation voltage is rised to 2000V.

  • PDF

DC Appliance Safety Standards Guideline through Comparative Analysis of AC and DC Supplied Home Appliances

  • Ahn, Jung-Hoon;Kim, Dong-Hee;Lee, Byoung-Kuk;Jin, Hyun-Cheol;Shim, Jae-Sun
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.51-57
    • /
    • 2012
  • This paper provides a safety guideline for DC supplied home appliances through the comparative analysis of existing safety guideline for AC supplied home appliances. For this purpose, a predictive DC home appliance model is suggested and in special international safety standards of AC appliances are also analyzed. Moreover, a DC distribution system is built to verify the validity of the proposed safety guideline. The detailed analyzing process is explained with help of informative experimental results.

Economic analysis of Electric heating appliances (전기난방기구의 경제성 분석 비교)

  • Kim, Yong-Ha;Lee, Kwang-Sung;Nam, Kim-Hyun;Park, Nam-Chul;Woo, Sung-Min;Kim, Mi-Ye;Lim, Hyun-Sung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.448-452
    • /
    • 2006
  • Many kinds of electric heating appliance is used by user interface and desire. Far infrared ray heating system can use a kind of main heating appliance. This paper gives un saving amounts, energy curtailment money and payback period between far infrared ray heating system and existing electric heating appliance - EHP, electric air heater, electric radiator, electric floor heating system - from economy analysis.

  • PDF

Electric Load Signature Analysis for Home Energy Monitoring System

  • Lu-Lulu, Lu-Lulu;Park, Sung-Wook;Wang, Bo-Hyeun
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.12 no.3
    • /
    • pp.193-197
    • /
    • 2012
  • This paper focuses on identifying which appliance is currently operating by analyzing electrical load signature for home energy monitoring system. The identification framework is comprised of three steps. Firstly, specific appliance features, or signatures, were chosen, which are DC (Duty Cycle), SO (Slope of On-state), VO (Variance of On-state), and ZC (Zero Crossing) by reviewing observations of appliances from 13 houses for 3 days. Five appliances of electrical rice cooker, kimchi-refrigerator, PC, refrigerator, and TV were chosen for the identification with high penetration rate and total operation-time in Korea. Secondly, K-NN and Naive Bayesian classifiers, which are commonly used in many applications, are employed to estimate from which appliance the signatures are obtained. Lastly, one of candidates is selected as final identification result by majority voting. The proposed identification frame showed identification success rate of 94.23%.

A Study on Development of Flux to Restrict Occurrence of ion Migration in Lead-Free Solder (무연솔더 내 마이그레이션 플럭스개발에 관한 연구)

  • Ryu Dong Su;Lim Jae Hoon;Woo Seong Woo
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2005.06a
    • /
    • pp.385-392
    • /
    • 2005
  • The restriction of the use of hazardous substances in electrical and electronic equipment legislation mandates the substitution of lead and other hazardous substances in electronics products by July 2006. Due to this legislative pressure, the electronics industry is moving to adoption of lead free solders. In this paper, we investigated a flux to restrict generating electrochemical migration in lead-free solder. The lead-free solders used in this study were Sn-0.7Cu-0.01P and Sn-3.0Ag-0.5Cu. To measure the resistance of electrochemical migration, the dew-cycle test and water drop test were adopted. As the result, now flux having high durable of electrochemical migration was developed.

  • PDF

Accelerated Life Test for Door Switch (도어스위치의 가속수명시험)

  • Kim Sang Uk;Jang Young Kee;Moon Chul Hui
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2005.06a
    • /
    • pp.327-337
    • /
    • 2005
  • Accelerated life test models and procedure are developed to assess the reliability of Door switch. The main function of door switch is to operate bulb lamp and fan motor. The accelerated life test method and test equipments are developed using the relationship between stresses and life characteristics of the products. Using the developed accelerated life test method, the parameters of the ALT model and life time distribution are estimated and the reliability of the Door S/W at use condition if assessed. The proposed accelerated life test method and procedure may be extended and applied to testing similar kinds of products to reduce test time and costs of the tests remarkably.

  • PDF

A Study on Interior Design of Domestic Electric Home Appliance Stores Applied with Store Identity Program(SIP) - Focused on Samsung Electric Home Appliance Stores - (Store Identity Program(SIP)이 적용된 국내 가전매장 실내디자인에 관한 연구 - 삼성전자 가전매장의 사례를 중심으로 -)

  • Noh, Chang-Young;Kim, Jin-Woo
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2007.05a
    • /
    • pp.160-165
    • /
    • 2007
  • Recently, the interior design of electric home appliance stores requires comprehensive image management with systemic marketing strategies and consistence in order to attract consumers to purchase products. However, the environment of domestic electric home appliance stores is complex and confused by indiscreet design factors and operation. Despite of the fact that company costs a lot of money to manage each store, consumers are not provided with selling environment with high quality. On the other hand, it is inevitable to compete with foreign specialized stores and discount malls due to opening distribution market. Besides, company has faced to attract customers with distinct strategies in order to survive in various competition system. In this sense, in store environment, there should be consistent image in interior design of the store based on management ideology of the company for the successful management of electric home appliance stores. The purpose of this research is to investigate and analyze the case of Samsung Electronics's electric home appliance stores among domestic electric home appliance stores that is applied with Store Identity Program (hereafter SIP) and to suggest solutions for the problems. Therefore, it is purposed to use as references for the stores that has the similar interior design plan. The result of this study is to upgrade the store image through providing basic data about role of data and distinct factors for competitive design as a part of Store Identity Strategy. Furthermore, it can be important data to optimize the profits and to make positive space for both consumer and company as company and products are credible with mental satisfaction of consumers if there is enough study on SIP and process and symbol of company and products to consumers, enough recognition and improvement on problems.

  • PDF

A Study on the appliance of performance based design to the automatic fire alarm system in clean room facility (클린룸 자동화재탐지설비의 성능위주 방재설계 적용에 관한 고찰)

  • Kim, Dong-Sung;Hwang, Cheol-Seung;Lee, Sang-Gon;Cho, Cheol-Won;Lee, Te-Shik
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.513-517
    • /
    • 2007
  • This study is to establish the appliance model for the automatic fire alarm system in clean room within the framework of the performance based design. Because of the environmental and dimensional characters of clean room, this space is exposed to fire and toxic damage, so it is very important to notify the occupants of these dangerous situations.

  • PDF

Development of Home Electrical Power Monitoring System and Device Identification Algorithm (가정용 전력 모니터링 시스템 및 장치식별 알고리즘 개발)

  • Park, Sung-Wook;Seo, Jin-Soo;Wang, Bo-Hyeun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.4
    • /
    • pp.407-413
    • /
    • 2011
  • This paper presents an electrical power monitoring system for home energy management and an automatic appliance-identification algorithm based on the electricity-usage patterns collected during the monitoring tests. This paper also discusses the results of the field tests of which the proposed system was voluntarily deployed at 13 homes. The proposed monitoring system periodically measures the amount of power consumption of each appliance with a pre-specified time interval and effectively displays the essential information provided by the monitored data which is required users to know in order to save power consumption. Regarding the field tests of the monitoring system, the households responded that the system was useful in saving electricity and especially the electricity-usage patterns per appliances. They also considered that the predicted amount of the monthly power consumption was effective. The proposed appliance-identification algorithm uses 4 patterns: Zero-Crossing Rate(ZC), Variation of On State(VO), Slope of On State(SO) and Duty Cycle(DC), which are applied over the 2 hour interval with 25% of it on state, and it yielded 82.1% of success rate in identifying 5 kinds of appliances: refrigerator, TV, electric rice-cooker, kimchi-refrigerator and washing machine.