• Title/Summary/Keyword: Apparatus Capacity

Search Result 175, Processing Time 0.027 seconds

Characteristics of Closed Circuit Cooling Tower with Variation of Tube Diameter (멀티패스 밀폐식 냉각탑의 관경변화 특성)

  • Shim, Gyu-Jin;Lee, Ho-Saeng;Kim, Eun-Pil;Yoon, Jung-In;Kwon, O-Ick
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.531-536
    • /
    • 2008
  • This paper presents experimental result of characteristics about Closed circuit Cooling Tower having a rated 2RT. The experimental apparatus has been set-up with a conventional type system. The test section is heat exchangers of cooling tower that consist of different vertical tubes, 15.88mm with 10 rows and columns and 19.05 mm with 8 rows and 12 columns. The main results were summarized as follows : The values of heat and mass transfer coefficients of cooling tower operating with two paths are higher than these with one path. Cooling capacity per unit volume using 15.88mm tubes are higher than 19.05mm tubes.

  • PDF

Evaluation of Energy Saving with Vector Control Inverter Driving Centrifugal Pump System (벡터 제어 인버터 구동 원심펌프시스템의 에너지 절감 평가)

  • Suh, Sang-Ho;Kim, Kyungwuk;Kim, Hyoung-Ho;Yoon, In Sik;Cho, Min-Tae
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.2
    • /
    • pp.67-72
    • /
    • 2015
  • The purpose of this study is to achieve energy saving effect of inverter driving multistage centrifugal pump. For determining the operation points in the pump system, the system curves should be obtained experimentally. To get the system curves, three pumps combined in parallel and one pump operated with different rotational speeds. But for variable speed pump system, energy saving rates can not be evaluated from operation efficiencies. That is why operation efficiencies, system curves, duty cycles, and input powers of the pump system were measured by the constructed experimental apparatus. The duty cycle segmented into different flow rates and weighting the average value for each segment by the interval time. The system was operated with two different periods. The mean duty cycles were collected from apartment and found that the system operated at 40% and at 50% or below capacity. Measured energy saving rate was 58.16%. Estimating method of energy saving rate could be more effective operation index than that of operation efficiency.

Performance Verification and Improvement of UHF Sensor for the Increasement of the Partial Discharge Detection Reliability (부분방전검출 신뢰도 향상을 위한 UHF 센서개선 및 성능검증)

  • Kim, Won-Gyu;Kim, Min-Soo;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1461-1466
    • /
    • 2014
  • GIS(Gas Insulated Switchgear) is important power apparatus which have strong dielectric strength, supply electric power and is a part of the power system. Most substation type is configured as GIS. Recently, because of continuous increasement of GIS demand resulted from high quality & big capacity of electric power, the necessity of the preventive & diagnosis system is being expanded gradually. GIS partial discharge occurred on the UHF band is detected effectively by the method to IEC 60270 that recommend to be able to detect the apparent minimum discharge, 5 pC. Additionally, the UHF sensor should be installed to detect PD signal if Partial discharge signal, 5 pC occur in every part of GIS. Currently PD diagnosis system applying UHF sensor for GIS with various voltage level like 154 kV, 345 kV, 765 kV have been operated. And it is necessary to measure and analyze insulation breakdown phenomenon of inside GIS exactly. In this paper, we proposed Fat-dipole patch UHF sensor that is developed and more sensitive, excellent wide-range characteristic than the exising UHF sensor. And we performed KERI (Korea Electrotechnology Research Institute) reference test, which showed the excellent result for the all tests.

Measurement of Shoulder Muscle Workload at Various Working Postures (작업자세에 따른 어깨근육의 작업부하 측정)

  • Kim, Jung-Yong;Park, Ji-Soo;Park, Chang-Soon;Phyun, Heung-Kook
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.25 no.2
    • /
    • pp.266-273
    • /
    • 1999
  • The maximum work capacity at various shoulder angles was estimated in terms of joint moment through maximum voluntary contraction (MVC) measurement, and the result was compared to workload computed from 3-D static lifting model (3DSSPP) based upon national institute of safety and health (NIOSH) lifting guideline (1991). The electromyography (EMG) of anterior/posterior deltoid and trapezius muscle was also recorded to study the function of individual muscle during asymmetric shoulder lifting. Psychophysical workload was measured to observe the difference from MVC or biomechanical estimation. An apparatus was constructed for the study and twenty five trials including five flexion angles and five add/abduction angles were performed isometrically. Results indicated that MVC at 30 degree of flexion was the strongest whereas MVC at 120 degree was the weakest. In case of add/abduction, MVC decreased to 77 to 89 % during add/abduction compared to the MVC at neutral position. Regarding the normalized EMG value, a substantial increase was observed at 30 and 60 degree abduction. More importantly, the shoulder moment computed from maximum permissible limit (MPL) was greater than the moment at MVC condition during 30 degree adduction. Current result can be used as a reference information for a safe workplace design to prevent the shoulder from an excessive work load in industry.

  • PDF

An Experimental Study for Reduction of Energy losses at Surcharged Four-way Combining Square Manhole (과부하 4방향 사각형 합류맨홀에서의 에너지 손실 저감을 위한 실험 연구)

  • Kim, Jung Soo;Kim, Chae Rin;Yoon, Sei Eui
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.2
    • /
    • pp.311-324
    • /
    • 2017
  • Energy loss at manholes under surcharged flow is considered as one of the major causes of inundation in urban area. Therefore, it is necessary to analyze the flow characteristics to reduce the energy loss in the surcharged four-way combining manhole. In this study, hydraulic experimental apparatus was constructed considering the results of the present survey. Square manholes and pipe diameters were reduced to 1/5 by applying sewer facility standards. Numerical simulations were carried out with the Fluent 6.3 model to derive the invert condition which can reduce the energy loss in the surcharged four-way combining square manhole. The hydraulic experiments were carried out according to the various conditions of the lateral flow rate($Q_{lat}/Q_{out}$), discharge of outflow pipe (2.0, 3.0, 4.0, 4.8 l/sec), and invert shape (rectangle and square open conduit type). The crossed invert was not found to improve the drainage capacity of the surcharged four-way rectangular combining manhole. However, the improved rectangle open conduit type invert and square open conduit type invert were analyzed to improve the drainage capacity by reducing the head loss coefficients by about 8% and 28%, respectively. Therefore, in order to increase the drainage capacity of urban facilities, it is possible to install and use the improved invert proposed in this study.

A Study on the Recent Trends and Prospects of Maritime Satellite Communication Systems (해사위성통신시스템의 현황과 전망)

  • 조성준
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.2 no.1
    • /
    • pp.20-28
    • /
    • 1977
  • The shipping business which consistutes main stream of foreign trades in the world desires more larger and higher speed ships to convey a large amount of cargo at a time rapidly and safely. They also want to introduce new techniques into transportation system so to meet the rapid growing demand of maritime mobile communications with the improvement of efficiency of radio apparatus and reduction of the hard labors of radio operators mechanization and modernization of radio apparatus is necessary. Now HF band is used mainly for communications between maritime mobile stations and coast stations but the quality of received signal is not so good and the coverage is not sufficient by the condition of propagation of waves. There is also limitation of channel capacity in HF band. So to cope with or improve of these defects and meet the demands of modern maritime communication it is essential to introduce maritime satellite communication system in this field. By using the maritime satellite we can establish high quality communication circuits as maritime Telex, Faximile, high speed data transmission line and can expand coverages. Therefore industrial rationalization of marine transportation is possible with the reduction of painful labors of radio operators by improving safety and promoting of efficiency of movement of ships and freights. Obviously it is prospected that the introduction of maritime satellite communication system will bring a rapid promotion of its usuage in maritime mobile communication field and also anticipated that maritime satellite communication system will be a main current in maritime mobile communication field over the world in the near future with moderated cost of transmission links as in the case of INTELSAT in the past 10 years after its first launching.

  • PDF

A Study on the CO2 Removal Efficiency with Aqueous MEA and Blended Solutions in a Vortex Tube Type Absorber (Vortex Tube 형 흡수장치에서 MEA와 혼합흡수용액을 이용한 CO2 제거 효율 고찰)

  • Ryu, Woo-Jung;Han, Keun-Hee;Choi, Won-Kil;Lee, Jong-Sub;Park, So-Jin
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.795-800
    • /
    • 2009
  • In this study, the $CO_2$ removal characteristics of the Vortex tube type absorbtion apparatus were investigated to enhance the compactness of $CO_2$ absorption process and to reduce the amount of absorbing solution of the $CO_2$ separation process. The Vortex tube with the diameter of 17 mm and the length of 250mm was introduced in the experimental apparatus to treat $20Nm^3/hr$ of $CO_2$ containing flue gas. The flue gases for experiments containing 11~13 vol% of $CO_2$ were supplied from the coal-firing CFBC power plant with 12 ton/hr of steam producing capacity. The mixed solutions of 20 wt% of MEA as base solution with the adding solutions like HMDA, AMP and KOH were used as absorbents. The experiments were executed under the various conditions like the absorbing solution concentrations in the range of 20 to 50 wt%, the flow rate of $CO_2$ containing flue gases in the range of 6 to $15Nm^3/hr$ and the flow rate of absorbing solution in the range of 1.0 to 3.0 l/min. As a results, the $CO_2$ removal efficiency of mixed absorbent of 20 wt% of MEA with HMDA was remarkable. From this study, we concluded that the efficient separation of $CO_2$ from flue gases using the features of the Vortex tube type absorbing unit for gas/liquid contact and the separation of gas/liquid be possible. But more works are needed to increase the $CO_2$ removal efficiency of Vortex tube process.

Development of an Apparatus for Vertical Transfer of a PRT Vehicle Operating on a Road Network (운행 중인 PRT 차량의 수직이송을 위한 장치 개발)

  • Kang, Seok-Won;Um, Ju-Hwan;Jeong, Rag-Gyo;Kim, Jong-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2604-2611
    • /
    • 2013
  • The Personal Rapid Transit(PRT) system has been highly interested in future transportation developments due to its on-demand and optimized door-to-door transport capability. However, the major impediments to the commercialization of PRT are the high cost for construction of infrastructures as opposed to the small transport capacity and difficulty in defining the role of PRT in building a balanced transportation system. In this study, the vertical transfer device for the PRT vehicle is developed to provide more flexible and better compatible urban mobility services between means of transportation, which is expected to meet particular demands in a particular environment. This apparatus was initially designed based on the basis of vertical circulating conveyors with steel chains, which is frequently used in logistics. Its advantages are capable of the non-stop loading and reduced head-way time. Most importantly, it was intensified by the additional idea to ensure the stable and reliable transfer of the PRT vehicle fully loaded with passengers. The 1/10-scale prototype was successfully tested to demonstrate a fundamental mechanism of vertical transfer and identify unexpected user requirements prior to a real manufacturing process.

Biopolitics, Montage, and Potentialities of the Image: Giorgio Agamben and Cinema (생명정치, 몽타주, 이미지의 잠재성: 조르조 아감벤과 영화)

  • Kim, Jihoon
    • Cross-Cultural Studies
    • /
    • v.49
    • /
    • pp.59-93
    • /
    • 2017
  • This paper provides an in-depth examination of the relationship between cinema and Giorgio Agamben's aesthetics and philosophy. Intersecting Agamben's key concepts including gesture, mediality, biopolitics, historicity, and profanation with historical and aesthetic dimensions of cinema, I argue for his ambivalent view on cinema and visual media. On the one hand, Agamben linked cinema and visual media to his discussion on biopolitics and spectacle as he considered them as apparatus for capturing and controlling gestures. On the other hand, he also argued that cinema could restore the image with capacity to preserve and recuperate gestures based on his consideration of montage as cinema's key aesthetic and technical component (an operation of profanation) and his Benjaminian thought on the ways in which montage suspended linear flow of images and activated an alternative memory of them. Drawing on history of cinema and optical devices in the 19th and early 20th centuries as well as examples of found footages of filmmaking predicated upon stoppage and repetition of images, I argue that Agamben's concept of potentialities can be extended into his thought on cinema and visual media apparatuses in general.

Analysis and Suggestion of Estimation Equation for Sedimentation in Square Manholes with Straight Path (사각형 중간맨홀에서의 유사 퇴적 분석 및 산정식 제안)

  • Kim, Jung-Soo;Song Ju-Il;Rim Chang-Soo;Yoon, Sei-Eui
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.2
    • /
    • pp.177-189
    • /
    • 2012
  • Sediment load deposited in sewers and manholes reduces not only the capacity of pipes but also the efficiency of the whole sewer system. This causes the inundations of the low places and overflows at manholes, Moreover, sulfides and bad odor can occur due to deposited sediment with organic loads in manholes. Movements of sediment load in manholes are complicated depending on manhole size, location, inside structure, sediment load type, and time. Therefore, it is necessary to understand the movements of sediment load in manholes by experiments. In this study, experiments were implemented by a square manhole with straight path to measure deposited sedimentation quantity. The experimental apparatus was consisted of a high water tank, an upstream tank, test pipes, a sediment supplier, a manhole, and a downstream tank to measure the experimental discharge. The quantity of deposited sediment load was measured by different conditions, such as the inflow condition of sediment(continuous and certain period), the amount of inflow sediment, discharge, and the type of sediment. Jumoonjin sand(S=2.63, D50=0.55mm), general sand(GS, S=2.65, D50=1.83mm) and anthracite (S=1.45, D50=0.80mm) were employed for the experiment. The velocities in inflow pipe were 0.45 m/s, 0.67 m/s, and 0.9 m/s. Sediment load movement and sedimentation quantity in manhole were influenced by many factors such as velocity, shear stress, viscosity, amount of sediment, sediment size, and specific gravity. Suggested regression equations can estimated the quantity of deposited sediment in the straight path square manholes. The connoted equations that were evaluated through the experimental study have velocity range from 0.45 to 0.9m/sec. The study results illustrates that appropriation of design velocity ragne between 1.0 and 2.0m/sec could implement to maintain and manage manholes.