DOI QR코드

DOI QR Code

Evaluation of Energy Saving with Vector Control Inverter Driving Centrifugal Pump System

벡터 제어 인버터 구동 원심펌프시스템의 에너지 절감 평가

  • Received : 2014.11.04
  • Accepted : 2015.02.10
  • Published : 2015.04.01

Abstract

The purpose of this study is to achieve energy saving effect of inverter driving multistage centrifugal pump. For determining the operation points in the pump system, the system curves should be obtained experimentally. To get the system curves, three pumps combined in parallel and one pump operated with different rotational speeds. But for variable speed pump system, energy saving rates can not be evaluated from operation efficiencies. That is why operation efficiencies, system curves, duty cycles, and input powers of the pump system were measured by the constructed experimental apparatus. The duty cycle segmented into different flow rates and weighting the average value for each segment by the interval time. The system was operated with two different periods. The mean duty cycles were collected from apartment and found that the system operated at 40% and at 50% or below capacity. Measured energy saving rate was 58.16%. Estimating method of energy saving rate could be more effective operation index than that of operation efficiency.

Keywords

References

  1. Ani bal T. de Almeida, Fernando JTE Ferreira and Dick Both., 2005, ".Technical and economical considerations in the application of variable-speed drives with electric motor systems.", IEEE Transactions on Industry Applications, Vol. 41. No. 1, pp. 188-199. https://doi.org/10.1109/TIA.2004.841022
  2. Pyun, K. B., Kim, J. H., Choi, Y. S. and Yoon, J. Y., 2011, "Design Optimization of a Centrifugal Pump Impeller using RSM and Design of Volute", Korean Society for Fluid Machinery, Journal of Fluid Machinery, Vol. 15, No. 3, pp. 39-45.
  3. Kim, S., Choi, Y. S., Yoon, J. Y. and Kim, D. S., 2008, "Design Optimization of Centrifugal Pump Impeller Using DOE", Korean Society for Fluid Machinery, Journal of Fluid Machinery, Vol. 11, No. 3, pp. 36-42. https://doi.org/10.5293/KFMA.2008.11.3.036
  4. Mo, J. O., Kim, Y. T. and Lee. Y. H., 2012, "Numerical Study on Cavitation Performance Evaluation in a Centrifugal Pump Impeller", Korean Institute of Navigation and Port Reserch, Proceedings of the 36th KOSME Spring Conference, Vol. 36, No. 2, pp. 286-293.
  5. Kim, S., Choi, Y. S. and Lee, K. Y., 2009, "A Numerical Study on the Flow Characteristics of Side-suction Inlet Geometry for Centrifugal Pump", Korean Society for Fluid Machinery, Journal of Fluid Machinery, Vol. 12, No. 6, pp. 7-12.
  6. Jin, H. b., Kim, M. J., Son, C. H. and Chung W. J., 2013, "Spiral Casing of a Volute Centrifugal Pump -Effects of the Cross Sectional Shape-", Korean Society for Fluid Machinery, Journal of Fluid Machinery, Vol. 16, No. 4, pp. 28-34. https://doi.org/10.5293/kfma.2013.16.4.028
  7. Jacobina, C. B., et al., 1995, "Vector and scalar control of a four switch three phase inverter." Industry Applications Conference, Thirtieth IAS Annual Meeting, IAS'95., Conference Record of the 1995 IEEE, Vol. 3, pp. 2422-2429.
  8. Suh, S.-H., Kim, H. H., MD. Rakibuzzaman, Kim, K. W. and Yoon, I. S., 2013, "A Study on the Performance Evaluation of Variable-speed Drive Pump", Korean Society for Fluid Machinery, Proceedings of the KFMA Annual Meeting 2013, p. 188.
  9. Ma, Zhenjun, and Shengwei Wang, 2009, "Energy efficient control of variable speed pumps in complex building central air-conditioning systems." Energy and Buildings, Vol. 41. No. 2, pp. 197-205. https://doi.org/10.1016/j.enbuild.2008.09.002
  10. Rakibuzzaman, Suh, S.-H., Kim, K. W., Kim, H. H., Yoon, I. S. and Cho, M. T., 2014, "A Study on Energy Saving Rate for Variable Speed Condition of Multistage Centrifugal Pump", The 5th Asian Joint Workshop on Thermophysics and Fluid Science 2014, p. 39.

Cited by

  1. 인버터 구동 원심펌프의 급수 사용율에 따른 에너지 절감 평가 vol.18, pp.6, 2015, https://doi.org/10.5293/kfma.2015.18.6.081
  2. 해수 담수화 공정의 고압펌프 가변속 운전에 따른 동력 절감 vol.20, pp.5, 2015, https://doi.org/10.5293/kfma.2017.20.5.033