• Title/Summary/Keyword: Apical Shaping

Search Result 45, Processing Time 0.024 seconds

Shaping characteristics of two different motions nickel titanium file: a preliminary comparative study of surface profile and dentin chip (두 가지 다른 행정의 니켈 티타늄 파일의 성형 성상: 표면 성상, 상아질 삭편과 도말층에 대한 예비적 비교 연구)

  • Park, So-Ra;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.121-130
    • /
    • 2014
  • Purpose: To assess the surface profile of dentinal wall, dentin chips and smear layer during the canal shaping with rotary (ProTaper) and ProFile and reciprocating (WaveOne) nickel-titanium file. Materials and Methods: Sixty human extracted mandibular premolars and incisors with single canals were randomly selected. Three experimental groups (n = 20) were instrumented with ProTaper (F2), ProFile (25/.06), WaveOne (25/.08) with irrigation of 2.5% NaOCl. The dentin chips were collected from flute of file during each canal preparation. After canal preparation, roots were grinded and each group was divided into two subgroups (n = 10) for surface profile and smear layer of dentinal wall of shaped root canal. Each specimen was observed under scanning electron microscope for evaluating size of dentin chips, root canal surface recessions and smear layer. Scores of Smear layer were statistically analyzed using Kruskal Wallis test and Mann Whitney test at P = 0.05 level. Results: The size of dentin chips from ProFile, ProTaper and WaveOne was up to $7{\mu}m$, $6.5{\mu}m$, and$4{\mu}m$, respectively. In the surface profile, the width of surface irregularity was measured and Profile, ProTaper and WaveOne was up to $150{\mu}m$, $70{\mu}m$, and $80{\mu}m$, respectively. Completely cleaned root canals were not found. In the middle and apical third of the canals, WaveOne group showed higher smear layer score than ProFile and ProTaper groups (P < 0.05). Conclusion: Within limits of this study, reciprocating motion WaveOne group was not significant difference of shaping ability with the full-sequence ProFile and ProTaper systems except canal clearness of middle and apical third of root canal. When using WaveOne to shaping root canal, thorough root canal irrigation is recommended.

MORPHOLOGIC ANALYSIS OF C-SHAPED ROOT USING 3-D RECONSTRUCTION (3차원 재구성법에 의한 C-shaped root의 형태분석)

  • Jung, Eun-Hee;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.421-431
    • /
    • 2002
  • C-shaped canal configuration is very difficult to treat because that clues about preoperative canal anatomy cannot be ascertained from clinical crown morphology and limited information can be derived from radiographic examination. This study was done to get more informations about the root and canal configuration of C-shape root by 3-dimensionally reconstructing for the purpose of enhancing success rate of endodontic treatment. 30 mandibular molars with C-shaped root were selected. Six photo images from occlusal, apical, mesial, distal, buccal, lingual directions and radiographic view were taken as preoperative ones to compare them with 3-D image. After crown reduction to the level of 1-2mm over pulpal floor was performed, teeth were stored in 5.25% sodium hypochlorite solution for the removal of pulp tissue and debris. They were cleaned under running water, allowed to bench dry and embedded in a self-curing resin. This resin block was serially ground with a microtome (Accutom-50, Struers, Denmark) and the image of each level was recorded by digital camera (FinePix S1-pro, Fuji Co., Japan). The thickness of each section was 0.25mm. Photographs of serial sections through all root canal were digitized using Adobe Photoshop 5.0 and then minimum thickness of open and closed sites were measured (open site is the surface containing occluso-apical groove closed site is oppsite). After dizitization using 3-D Doctor (Able software Corp, USA). 3D reconstruction of the outer surface of tooth and the inner surface of pulp space was made. Canal classsification of C-shaped roots was performed from this 3-D reconstructed image. The results were as follows : 1. Most C-shape rooted teeth showed lingual groove (28/30). 2 According to Vertuccis' calssification, type I, II, III, IV, VII were observed. but also new canal types suck as 2-3-2, 1-2-3-2. 2-3-2-1, 2-3-2-3 were shown. 3 There was little difference in minimum thickness on coronal and apical portions, but open site were thinner than closed site on mid portion. Conclusively, 3D reconstruction method could make the exact configurations of C-shape root possible to be visualized and analyzed from multi-directions. Data from minimum thickness recommend cleaning and shaping be more carefully done on dangerous mid portion.

Shaping Ability of Four Rotary Nickel-Titanium Instruments to Prepare Root Canal at Danger Zone (네 가지 전동 Ni-Ti 파일의 danger zone에서의 근관성형력)

  • Choi, Seok-Dong;Jin, Myoung-Uk;Kim, Ki-Ok;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.5
    • /
    • pp.446-453
    • /
    • 2004
  • The aim of this study was to evaluate the shaping abilities of four different rotary nickel-titanium instruments with anticurvature motion to prepare root canal at danger zone by measuring the change of dentin thickness in order to have techniques of safe preparation of canals with nickel-titanium files. Mesiobuccal and mesiolingual canals of forty mesial roots of extracted human lower molars were instrumented using the crown-down technique with ProFile, $GT^{TM}$ Rotary file, Quantec file and $ProTaper^{TM}$. In each root, one canal was prepared with a straight up-and-down motion and the other canal was with an anticurvature motion. Canals were instrumented until apical foramens were up to size of 30 by one operator. The muffle system was used to evaluate the root canal preparation. After superimposing the pre- and post-instrumentation canal. change in root dentin thickness was measured at the inner and outer sides of the canal at 1. 3, and 5 mm levels from the furcation. Data were analyzed using two-way ANOVA. Root dentin thickness at danger zone was significantly thinner than that at safe zone at all levels (p < 0.05). There was no significant difference in the change of root dentin thickness between the straight up-and-down and the anticurvature motions at both danger and safe zones in all groups (p > 0.05). ProTaper removed significantly more dentin than other files especially at furcal 3 mm level of danger and safe zones (p < 0.05) Therefore, it was concluded that anticurvature motion with nickel-titanium rotary instruments does not seem to be effective in danger zone of lower molars.

COMPARISON OF SHAPING ABILITY OF ROTARY Ni-Ti FILE SYSTEMS USED BY UNDERGRADUATES (학생들이 사용한 엔진 구동형 Ni-Ti file systems의 근관 성형 효율 비교)

  • Kang, Mun-Seong;Kim, Hyeon-Cheol;Hur, Bock;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2006
  • The purpose of this study was to compare the shaping ability of three Ni-Ti file systems used by dental students or the experts and consequently to aid in choosing a proper systems for educational courses of dental students and beginners. Fifty students and ten dentists who have clinical experience over two years prepared 180 simulated root canals in resin blocks with three Ni-Ti systems; $ProFile^{(R)}\;(PF),\;HeroShaper^{(R)}\;(HS),\;K3^{TM}\;(K3)$. After preparation, the Ni-Ti files were evaluated for distortion and canal preparation time was recorded. The images of pre- and post-instrumented canals were scanned and superimposed. Amounts of increased canal widths, deviation, and centering ratio were calculated at apical 1, 3 and 5 mm levels and statistical analysis was performed The results were as follows : 1. HS showed the shortest preparation time and instrumented canal width in K3 was significantly larger than other groups (P<0.05). 2. At 1 and 3mm levels, all groups had outward deviation. In student group, at the 1mm level, PF had the least deviation (P<0.05). 3. In the centering ratio, the PF had the best centering ability compared to the others at 5mm level. At 1 and 3mm levels, HS and PF had better abilities than K3. Student group had better ratio than the expert at 3mm level with PF (P<0.05). Based on the results, it is surmised that the $ProFile^{(R)}$ is the safest and most ideal instrument for students and beginners.

Outcome Assessment of Endodontic Treatment of Mandibular Second Molars with C-shaped Canals in Elderly Patients

  • Go, Yu-Ra;Kim, Mi-Yeon;Kim, Sun-Ho;Kim, Jeong-Hee;Kim, Ran-Ah
    • Journal of Korean Dental Science
    • /
    • v.14 no.2
    • /
    • pp.61-68
    • /
    • 2021
  • Purpose: The aim of this study was to investigate the outcomes of endodontic treatment of mandibular second molar with C-shaped canal in elderly patients and related factors affecting the survival of the tooth. Materials and Methods: From 2010 to 2015, the survival rate following endodontic treatment was evaluated in elderly patients over 60 years who visited the Veterans Health Service Medical Center for endodontic treatment. The presence of C-shaped canals was confirmed using clinical records and radiographic features. Patient's age, sex, systemic diseases, tooth location, vitality, signs and symptoms, fractures, caries, apical radiolucency, canal shaping methods, sealer leakage, filling voids, and restoration of prosthesis were included in the analyses as confounding variables. The survival rate of teeth was analyzed using Kaplan-Meire analysis and the relationship between the survival rate and variables was analyzed using Simple and Multiple Cox regression analysis. Result: In total, 107 teeth in elderly patients had C-shaped canal. The survival rate of teeth that received endodontic treatment was 63.70%. None of the factors investigated significantly influenced the survival rate (P>0.05). Conclusion: In elderly patients with C-shaped canal, the survival rate after root canal treatment was not significantly different from that of other mandibular molars.

Comparison of shaping ability between various hybrid instrumentation methods with ProTaper (ProTaper를 사용한 다양한 hybrid instrumentation methods의 근관성형 효율 비교)

  • Hong, Eun-Sook;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.1
    • /
    • pp.11-19
    • /
    • 2006
  • The purpose of this study was to compare and evaluate the shaping abilities of various hybrid instrumentation method using constant tapered file systems with $ProTaper\^{(R)}$ S1 and the difference between experts and inexperienced clinicians in use of NiTi file. Three hybrid methods used in this study were composed of $ProTaper\^{(R)}\;S1\;and\;K-Flexofile\^{(R)}\;(group S),\;ProTaper\^{(R)}\;S1\;and\;HeroShaper\^{(R)}\;(group\;H),\;and\;ProTaper\^{(R)}\;S1\;and\;ProFile\^{(R)}\;(group\;P)$respectively. The $ProTaper\^{(R)}$-alone method (group C) was introduced as a control group. After canal preparation, the lapse of time was recorded. The images of pre- and post-operative canal were scanned and superimposed. Amounts of instrumented canal widths and centering ratio were measured at apical 1, 2 and 3 mm levels and statistical analysis was performed In this study. both of the group C and S took more time to prepare canals than other groups, Inexperienced operators required more time for the entire preparation with the groups C and H than the experienced (p<0.05). And the centering ratio of group P were preferable to $ProTaper\^{(R)}$-alone method or the hybrid technique using stainless steel files. As such, within experienced operators, group H also showed better results in addition to the group P. Under these condition, the hybrid methods of each the $ProFile^{(R)}$ system and $HeroShaper^{(R)}$ with ProTaper are recommendable comparative to $ProTaper\^{(R)}$-alone method. According to the results, the hybrid instrumentation method is a more appropriate method of canal preparation than single file system for narrow or curved canals.

Comparison of the Frequency of Pain Occurrence by Using Different Calcium Hydroxide Pastes and Root Canal Sealers (수종의 수산화칼슘 근관 첩약제와 레진계 근관 실러의 사용 후 통증 발생 빈도에 관한 연구)

  • Kwak, Sang Won;Kim, Hyeon-Cheol
    • The Journal of the Korean dental association
    • /
    • v.56 no.5
    • /
    • pp.254-262
    • /
    • 2018
  • Objectives: This study aimed to compare the postoperative pain and clinical performance after applying three different intracanal medicaments and root canal sealers. Materials and Methods: Sixty-five patients requiring root canal treatment due to symptomatic apical periodontitis were included in this study. After a glide path preparation by using PathFile, each canal was shaped with ProTaper Next file system. After the canal cleaning and shaping procedure, the canal was dried and each intracanal medicaments were adjusted (Calcipex II, TRC-paste, Metapaste). At the next visit, the patients were requested to answer the absence of the pain after the procedure. Once the patients showed no symptom, the canal was obturated with each corresponded root canal sealers (AH plus, Radic-sealer, ADseal). The patients were recalled after 1 week, 1, 3, and 6 months to check the postoperative pain or unexpected clinical signs. One-way ANOVA and Duncan's post hoc comparison, and Chi-square test were used for statistical analysis to evaluate any differences among tested materials. Results: The average number of visits for intracanal medication was 2.69, 2.65, and 2.61 for Calcipex II, TRC-paste, and Metapaste. There were no statistically differences in post-obturation pain among three groups obturated with different root canal sealers (P > 0.05). Conclusions: Under the limitations of this study, three tested intracanal medicaments and epoxy resin root canal sealers showed clinically acceptable similar results.

  • PDF

Root canal volume change and transportation by Vortex Blue, ProTaper Next, and ProTaper Universal in curved root canals

  • Park, Hyun-Jin;Seo, Min-Seock;Moon, Young-Mi
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.1
    • /
    • pp.3.1-3.10
    • /
    • 2018
  • Objectives: The aim of this study was to compare root canal volume change and canal transportation by Vortex Blue (VB; Dentsply Tulsa Dental Specialties), ProTaper Next (PTN; Dentsply Maillefer), and ProTaper Universal (PTU; Dentsply Maillefer) nickel-titanium rotary files in curved root canals. Materials and Methods: Thirty canals with $20^{\circ}-45^{\circ}$ of curvature from extracted human molars were used. Root canal instrumentation was performed with VB, PTN, and PTU files up to #30.06, X3, and F3, respectively. Changes in root canal volume before and after the instrumentation, and the amount and direction of canal transportation at 1, 3, and 5 mm from the root apex were measured by using micro-computed tomography. Data of canal volume change were statistically analyzed using one-way analysis of variance and Tukey test, while data of amount and direction of transportation were analyzed using Kruskal-Wallis and Mann-Whitney U test. Results: There were no significant differences among 3 groups in terms of canal volume change (p > 0.05). For the amount of transportation, PTN showed significantly less transportation than PTU at 3 mm level (p = 0.005). VB files showed no significant difference in canal transportation at all 3 levels with either PTN or PTU files. Also, VB files showed unique inward transportation tendency in the apical area. Conclusions: Other than PTN produced less amount of transportation than PTU at 3 mm level, all 3 file systems showed similar level of canal volume change and transportation, and VB file system could prepare the curved canals without significant shaping errors.

Evaluation of canal preparation with Ni-Ti rotary files by micro computed tomography

  • Lee, Jeong-Ho;Kim, Mi-Ja;Seok, Chang-In;Lee, Woo-Cheol;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.4
    • /
    • pp.378-385
    • /
    • 2004
  • The purpose of this study was to compare the effects of preparation with GT files and profiles .04 in shaping of root canals and reconstruct the three-dimensional root canal system using micro computed tomography 40 canals of the extracted human mandibular molars were used, and randomly distributed into two experimental groups. In group 1. canals were prepared by GT files. In group 2, Profiles .04. were used. Apical preparation size was #30. For each tooth pre and post operative cross-sectional images were obtained by the micro CT at 50 micron intervals. Pre and post operative cross-sectional images of 1, 2, 3, 5, and 8mm from the apex were compared. For each section. canal area and centering ratio were determined. For each tooth pre- and post-operative root canal volume from the furcation to the apex of the roots was calculated by three-dimensional image software. Following results were obtained: 1. At 8mm from the apex, area of dentin removed by GT rotary file was significantly larger than that by Profile .04. And at the other levels there was not a significant difference. 2. There was a trend for GT rotary file to remain more centered in the canals than Profile .04 at all levels. But at 3mm level. there was a statistically significant difference. 3. In root canal volume increments after instrumentation, there was no significant difference between two groups.

THE INFLUENCE OF DIFFERENT ACCESS CAVITY DESIGNS ON THE FRACTURE STRENGTH IN ENDODONTICALLY TREATED MANDIBULAR ANTERIOR TEETH (근관와동형태에 따른 근관치료된 하악절치의 파절강도)

  • Lee Young-Gyun;Shin Hye-Jin;Park Se-Hee;Cho Kyung-Mo;Kim Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.6
    • /
    • pp.515-519
    • /
    • 2004
  • Straight access cavity design allows the operator to locate all canals, helps in proper cleaning and shaping, ultimately facilitates the obturation of the canal system. However, change in the fracture strength according to the access cavity designs was not clearly demonstrated yet. The purpose of this study was to determine the influence of different access cavity designs on the fracture strength in endodontically treated mandibular anterior teeth. Recently extracted mandibular anterior teeth that have no caries, cervical abrasion, and fracture were divided into three groups (Group 1 : conventional lingual access cavity, Group 2 : straight access cavity, Group 3 : extended straight access cavity) according to the cavity designs. After conventional endodontic treatment, cavities were filled with resin core material. Compressive loads parallel to the long axis of the teeth were applied at a crosshead speed of 2mm/min until the fracture occurred. The fracture strength analyzed with ANOV A and the Scheffe test at the 95% confidence level. The results of this study were as follows: 1. The mean fracture strength decrease in following sequence Group 1 (4558.90{\;}\pm{\;}77.40{\;}N$), Group 2 ($494.07{\;}\pm{\;}123.98{\;}N) and Group 3 ($267.33{\;}\pm{\;}27.02{\;}N). 2. There was significant difference between Group 3 and other groups (P = 0.00). Considering advantage of direct access to apical third and results of this study, straight access cavity is recommended for access cavity form of the mandibular anterior teeth.