A Study on the Energy Consumption and the Degree of Satisfaction by Heating System in Rental Apartment (임대아파트 난방방식별 에너지소비와 만족도 조사에 관한 연구)

  • 박민용;장승재
    • Journal of the Korean housing association
    • /
    • v.14 no.3
    • /
    • pp.85-92
    • /
    • 2003
  • Considering the present development situation of rental apartment since 1982, the supply of homeless housing for low-income dwellers has contributed a amount of quantities, but has been deficient qualities in housing policy. To propose the energy policy for low-income dwellers, this study investigated the energy consumption and the degree of heating satisfaction by heating system through questionaries in permanent rental apartment and 50 year period rental apartment complexes. The results of this study were as follows; The annual energy consumption of heating and hot water supply is 267.2 Mca1/$\textrm{m}^2$ㆍyr in central heating system, is 163.9 Mca1/$\textrm{m}^2$ㆍyr in unit heating system. But from the view of annual energy cost and the degree of heating satisfaction, central heating system were better than unit heating system in rental apartment.

The Economic Analysis on the Heating System Remodeling by the Life Cycle Costing in Permanent Rental Apartment (LCC 기법을 이용한 영구임대아파트 난방방식 리모델링에 대한 경제성분석 -유지관리비용을 중심으로-)

  • 박민용;장승재
    • Journal of the Korean housing association
    • /
    • v.15 no.1
    • /
    • pp.33-40
    • /
    • 2004
  • Considering the present development situation of rental apartment since 1982, the supply of rental housing for low-income dwellers has contributed a amount of quantities, but has been deficient qualities in housing policy. To propose the device of remodeling for low-income dwellers in deteriorated apartment, this study investigated the energy consumption of central heating system and the characteristics of maintenance cost in permanent rental apartment. The results of evaluation of alternative heating systems by Life Cycle Costing in permanent rental apartment were as follows; From Life Cycle 15∼20 years by Present Worth Method, the economic heating system of remodeling is central heating system (heat source: B-C oil), unit heating system(natural gas), central heating system(natural gas) in order.

Analysis of Heating Energy in a Korean-Style Apartment Building 1: The Effect of Location (한국형 아파트의 난방에너지 분석 1: 위치의 영향)

  • 유호선;현석균;박유원;김용식;홍희기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.101-110
    • /
    • 2004
  • This paper presents an analysis of heating energy for apartment houses in a Korean-style apartment building, paying special attention on the effect of their location. Six representative locations encompass three floors and two placements on each floor. Two different roof types are also considered. In order to incorporate actual tenant's refit, a five-zone model composed of one conditioned and four unconditioned spaces is developed. TRNSYS 15 is adopted to estimate heating energy. The predicted results show fairly good agreements with the available measured data, validating the present model. Heating energy needed for an apartment located at the uppermost and lowermost floors is far greater compared with the case of intermediate floors. In addition, an appreciable difference is found between apartment with and without side end wall. Insulation thickness of walls, floors and underground structure appears to be a dominant factor affecting heating energy, which leads to needs of revision of the related regulation. Ridged-roofs instead of flat-roofs are highly recommended in apartment buildings for effective energy saving. It is finally concluded that the location-dependent, severe imbalance in heating energy should be improved and/or reflected in the policy making process and design standards.

Proposal of Unit Building Method for Calculating Unit Heating Load of Apartment Houses (공동주택 단위난방부하 계산을 위한 단위동법 제안)

  • Yoo Ho-Seon;Chung Joo-Hyuk;Moon Jung -Hwan;Lee Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.68-76
    • /
    • 2007
  • As an alternative approach to evaluate the unit heating load for apartment houses, we newly developed and proposed unit building method. The new method, which calculates the heating load of an apartment building as a whole, conceptually corresponds to integral analysis of building heat loss, while the existing unit apartment method to differential analysis. Four typical building models of Korean-style apartment house and two dynamic load calculation programs were selected to validate the present method under realistically imposed conditions. Eight sets of unit heating load calculated respectively by unit building and unit apartment methods showed excellent agreements regardless of building model and simulation program. It is expected that the unit building method can take the place of the unit apartment method due to fewer modeling assumptions as well as less computational efforts. Additional calculations to investigate the effects of various parameters on unit heating load yield good consistencies with known facts, and re-confirm the validity.

Improvement of Design Criteria in Heating and Cooling Equipment According to the Consolidation of Design Standard for Energy Saving in Apartment Buildings of Korea (국내 공동주택의 에너지절약 설계기준 강화에 따른 냉난방설비 설계 기준 개선 방안)

  • Lim, Jae-Han;Kim, Sung-Im;Song, Seung-Yeong
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.89-97
    • /
    • 2014
  • Recently design standard for energy-saving in apartment buildings has been consolidated gradually on the basis of evaluation and certification standards of energy efficiency of buildings, the energy-saving policy of building at home and abroad. Performance criteria for thennal insulation as well as fenestration has been progressively enhanced, and performance criteria for ventilation and airtightness of the building have also been re-developed. Therefore, heating and cooling load characteristics of the apartment building can be changed. For the design of the upcoming heating and cooling equipment in apartment buildings, it is necessary to evaluate the heating and cooling load characteristics according to the design strategies for energy saving in apartment buildings. As a result, in this study, it is intended to use as a resource for analyzing the impact that the adoption of energy-saving design variables for each of the apartment buildings, to predict the heating and cooling load characteristics in the apartment building.

An Investigation on the Effect of Duration of Sunshine on the Heating Energy of Apartment Houses (일조시간이 아파트 난방에너지 소비량에 미치는 영향에 관한 조사연구)

  • Lee Jong-Won;Hwang Hye-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.3
    • /
    • pp.277-284
    • /
    • 2005
  • The purpose of this study is to analyze the effect of sunshine on the heating energy consumption of apartment houses by a field investigation in Haeundae, Busan. In the field, heating energy consumption of every household is researched by reading a calorimeter and the duration of sunshine of every household is calculated by Sunlight V1.0. Then, the duration of sunshine and heating energy are done regression analysis by SPSS 10. According to this study the apartment houses by orientation spend more energies order of east, west, southeast, southwest, and south. When apartment houses are same orientation, there is difference of $29{\sim}58\%$ in heating energy consumption by the duration of sunshine. And the heating energy consumption in worst condition of sunshine increases $67\%$ on the best condition of sunshine.

The Analysis of the Heating Energy in Apartment Houses with Pilotis (공동주택에서 필로티 세대의 난방에너지 분석)

  • Ahn, Min-Hee;Choi, Chang-Ho;Lee, Hyeon-Woo;Cho, Min-Kwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.1
    • /
    • pp.99-104
    • /
    • 2006
  • This paper presents an analysis of heating energy for apartment houses in apartment building, paying special attention on the effect of pilotis which is increasing recently. A four-zone model composed of one conditioned and three unconditioned space is developed in this study. IES VE is adopted to estimate heating energy. Especially, we used Apache module for a heating energy calculated. The predicted result shows fairly good agreements with the available measured data and simulation data. Heating energy needed for an apartment located on the pilotis floors is far greater compared with the case of intermediate floors. Insulation thickness of walls, floors and underground structure appears to be a dominant factor affecting heating energy, which leads to needs of revision of the related regulation. It is finally concluded that the location dependent, severe imbalance in heating energy should be improved and reflected in the policy making process and the design standards.

The Comparison of Maintenance Cost and Residents′Consciousness of Remodeling by Rental Apartment Types (임대아파트 유형별 유지관리비와 거주자의 리모델링 의식비교)

  • 박민용;장승재
    • Journal of the Korean housing association
    • /
    • v.14 no.4
    • /
    • pp.69-76
    • /
    • 2003
  • Considering the present development situation of rental apartment since 1982, the supply of rental housing for low-income dwellers has contributed a amount of quantities, but has been deficient qualities in housing policy. To propose the device of remodeling for low-income dwellers in deteriorated apartment, this study investigated the characteristics of maintenance cost and the residents'consciousness of remodeling by rental apartment types. The results of this study were as follows; The annual maintenance cost of permanent rental apartment was 14,249 won/$\textrm{m}^2$$.$yr, that of fifty years period rental apartment was 13,372 won/$\textrm{m}^2$$.$yr. In the case of remodeling in deteriorated heating system, the principal decision factor of choice was showed “economics” as priority. Residents in rental apartment preferred remodeling to reconstruction, and unit heating system to central heating system.

A Study on the Modernization of the Heating Method of Apartment Houses in the 1950s and 1960s Korea - Focusing on Haengchon, Jongam, Mapo Apartments - (1950~60년대 한국 아파트의 난방 방식 근대화에 관한 연구 - 행촌, 종암, 마포아파트를 중심으로 -)

  • Lee, Byoung-Heon;Kim, Hyon-Sob
    • Journal of architectural history
    • /
    • v.30 no.6
    • /
    • pp.33-44
    • /
    • 2021
  • The traditional Korean heating system ondol, one of the most important characteristics of Korean architecture, still remains as hydronic floor heating. Various studies have been conducted on the modernization of ondol, but the process of introducing the hydronic floor heating has not been seriously studied so far. Therefore, this paper aims to demonstrate how the hydronic floor heating had been introduced to Korea, taking the 1950s and 1960s Haengchon, Jongam, and Mapo Apartments for example - these three are regarded as the first Korean apartment houses after the Korean War. While Western advanced construction technology was imported for these apartments, various methods of modernizing ondol were also considered. What was remarkable in these attempts is that hydronic floor heating first appeared in Mapo 1st Apartment in 1962, because this is the universal heating method in the present Korea. This fact signifies that the traditional principle of floor heating has been maintained, and it would also be meaningful in terms of architectural exchanges between East and West, if considered along with Wright's application of the Korean heating principle to his houses since 1930s.

LS-SVM Based Modeling of Winter Time Apartment Hot Water Supply Load in District Heating System (지역난방 동절기 공동주택 온수급탕부하의 LS-SVM 기반 모델링)

  • Park, Young Chil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.9
    • /
    • pp.355-360
    • /
    • 2016
  • Continuing to the modeling of heating load, this paper, as the second part of consecutive works, presents LS-SVM (least square support vector machine) based model of winter time apartment hot water supply load in a district heating system, so as to be used in prediction of heating energy usage. Similar, but more severely, to heating load, hot water supply load varies in highly nonlinear manner. Such nonlinearity makes analytical model of it hardly exist in the literatures. LS-SVM is known as a good modeling tool for the system, especially for the nonlinear system depended by many independent factors. We collect 26,208 data of hot water supply load over a 13-week period in winter time, from 12 heat exchangers in seven different apartments. Then part of the collected data were used to construct LS-SVM based model and the rest of those were used to test the formed model accuracy. In modeling, we first constructed the model of district heating system's hot water supply load, using the unit heating area's hot water supply load of seven apartments. Such model will be used to estimate the total hot water supply load of which the district heating system needs to provide. Then the individual apartment hot water supply load model is also formed, which can be used to predict and to control the energy consumption of the individual apartment. The results obtained show that the total hot water supply load, which will be provided by the district heating system in winter time, can be predicted within 10% in MAPE (mean absolute percentage error). Also the individual apartment models can predict the individual apartment energy consumption for hot water supply load within 10% ~ 20% in MAPE.