Heating Energy Consumption Analysis of the Apartment Applied District Heating System (지역난방 공동주택의 단지별 난방사용량 분석 연구)

  • Park, Sun-Hyo;Lee, Hyun-Jung;Kwon, Kyung-Woo;Lee, Byung-Seok;Kim, Yang-Sub
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.293-298
    • /
    • 2012
  • The purpose of this study is performance validation of district heating apartments about heating energy consumption and analysis of energy consumption by unit characteristics. The heating energy consumption of the existing apartments was analyzed and the analyzed results will be used for energy saving technology development and policy making. The heating energy consumption data about total 78 apartment complexes, 56,910 units in Gangnam-Gu, Seoul, Korea were investigated from October, 2010 to April 2011. The analysis results are as follows; The mean heating energy consumption is 98[kWh/m2]. The energy consumption of Apgujung-Dong, Daechi-Dong is higher than that of mean valuse. The energy consumption deviation by deterioration, unit area, core type and regional group is very high. Specially, building deterioration casts a long shadow.

  • PDF

Numerical Analysis of Heavy-weight Impact Noise for Apartment Units Considering Acoustic Mode (음향모드를 고려한 공동주택 중량충격음 소음해석)

  • Mun, Dae-Ho;Park, Hong-Gun;Hwang, Jae-Seung;Hong, Geon-Ho;Im, Ju-Hyeuk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.7
    • /
    • pp.676-684
    • /
    • 2012
  • Numerical analysis was performed to investigate the heavy-weight impact noise of apartment houses. The FEM is practical method for prediction of low-frequency indoor noise. The results of numerical analysis, the shape of the acoustic modes in room-2 are similar to that of acoustic pressure field at the fundamental frequency of acoustic modes. And the acoustic pressure was amplified at the natural frequency of the acoustic modes and structural modes. The numerical analysis result of sound pressure level at 63 Hz and 125 Hz octave-band center frequency are similar to the test results, but at 250 Hz and 500 Hz have some errors. Considering most of bang-machine force spectrum exists below 100 Hz, the noise at 250 Hz and 500 Hz are not important for heavy-weight impact noise. Thus, the FEM numerical analysis method for heavy-weight impact noise can apply to estimate heavy-weight impact noise for various building systems.

A Study on the Trends of Remodeling in the Apartment Housing Unit - Focused on case study of the Korea National Housing Corporation - (공동주택 주호의 리모델링 경향에 관한 연구 - 대한주택공사 리모델링 사례 및 현상공모전 사례를 중심으로 -)

  • 오진수;조영호
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.5
    • /
    • pp.198-205
    • /
    • 2004
  • The remodeling of apartment that improves the improves the life level is going to be in the market because of lots of old apartment buildings. Until now, the research of remodeling is mainly restricted to the laws and financial funding, however, the needs in the trend of remodeling. This research, first, through the examples of remodeling in the country, this study draws remodeling factors that can be applied. Secondly, this study targets the study of remodeling to apartments and analyzes the type of housings made by the Korea National Housing Corporation. Thirdly the study analyzes the features that appear in housing units and draws out factors of remodeling This research's result is arranged as follows. \circled1Need Remodeling thorough study of space expanded, grant between artificer and active performance improvement direction such as building equipment expansion along with Remodeling concept of unit repair. \circled2When apartments are newly built, systematic construction is necessary that considers future efficiency improvement from the design stage. \circled3This study, which applied the characteristic factors appearing after the 1990s to remodeling factors, show that they can be applied when remodeling the worn out wall-slab type apartments.

The Analysis of Satisfaction and Preference Rates of Bathroom Design in Mid-class Apartment Residents - Focused on Residents's age of Brand Apartment in Seoul Metropolitan Area - (중규모 아파트 거주자의 욕실디자인 만족도와 선호도 분석 - 수도권 브랜드 아파트 거주자의 연령을 중심으로 -)

  • Shin, Kyung-Joo;Hwang, Yun-Jung;Rhee, Jee-Heon
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.5
    • /
    • pp.12-22
    • /
    • 2008
  • The purpose of this article is to establish fundamental sources and guidelines of bathroom designs of brand apartments in Korea. The article examines the current conditions of bathroom, satisfaction rates, and preference rates of residents in Mid-sized apartment units of the top five brand apartments based on construction capacity and brand popularity. A total of 427 samples, acquired via internet survey, were analyzed with the statistical computer program SPSS PC+ window version 15.0. The conclusions of the article are as follows: 1) Fixtures and products which fulfill various behaviors, as well as multi-functional space programming, are demanded. 2) Developing clear standards of basic bathroom fixtures and environments is also required in further research and to be applied to practical bathroom design. 3) The bathroom fixtures and environments ought to accommodate all age groups. 4) Respondents preferred a separated dry floor, either toilet or sink portion, to a full-dry or full-wet floor. 5) Respondents of all age groups considered bathroom as a private space, thus it should facilitate various private activities. The results of this study would contribute to adequate and sound bathroom design as key information.

A basic study on the development Interior design Database for consumer trend analysis system method on the Web (소비자 기호 분석을 위한 웹 기반 실내디자인 데이터베이스 시스템 개발에 관한 기초 연구 - 아파트 주거공간을 중심으로 -)

  • 한영호;김홍기;조성오
    • Korean Institute of Interior Design Journal
    • /
    • no.31
    • /
    • pp.71-78
    • /
    • 2002
  • Understanding the consumer changed life styles are integrated, mutual complement for user's worth and consciousness, the life of consumption, etc. Recently, Apartment Model House has built for distribute to Apartment house When they enter the units after 2 or 3 years. So, Interior designer make an inference from the changed life styles. But, We don't have enough information to trace the design trend about residential space design. Design database is correspond with interior space and structured entity relationship. There are three parts in this Database, Type, Elements and Relation information. Type are composed size, ages, style, and space, Elements are materials and space elements. Relation information are publishing, designer, exhibition, construction company, remodeling, Intoner design and User favorite styles are the development in web environment. This research supplies interior design information for Web environment and trend analysis supports collaboration with development of interior design information database.

A Study on Solar Heating System Technology Combining Multiple Technology with Mutual-Complementary Method - Low-cost, high efficiency, large-scale use of solar heating system - (다원기술 상호보완식 태양열 난방기술 - 저원가 고효율 규모화 태양열 난방 방안 -)

  • Nan, Bao-Xuan
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.15-23
    • /
    • 2008
  • The article deals with system technology of a new solar heating system which systematically combines exiting solar collector technology, auxiliary electrical water heating, floor heating system and well insulated construction method and its application of this system to apartment house heating system in the cold region, and also analyzed performance of the new system in terms of technical and economic feasibility. Results shows that energy efficiency approaches up to 50% of the energy consumption of local construction from 1980 to 1981. The implementation of "DQ technology" to floor heating system achieved from 79% to 85% of the energy-saving benefits comparing to other housing units which were supplied by the local district heating plant.

A Study on Ventilation Characteristics Made by Thin Line Type Ventilator in an Apartment House (창호형 환기장치에 의한 아파트의 환기성능에 대한 연구)

  • Chang, Hyun-Jae;Kim, Hyung-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.3
    • /
    • pp.201-207
    • /
    • 2011
  • Total heat recovery type ventilators that are connected to each room with ducts are mainly installed in Korea, but they raise concern over duct pollution. In this study, indoor environments made by thin line type ventilators installed in dwelling units of apartment houses are investigated by CFD. Results show the case that thin line type ventilators installed in each room-including kitchens-make the best indoor environment that maintains air velocity at under 0.25m/s, and evenly distributes the age of air in all areas.

A Study on the Variety of Elevations comply with Plan Variations in Wallgae Mansion (공동주택의 평면변화에 따른 외관 입면의 다양성에 관한 연구 - 한남동 월계맨션을 중심으로 -)

  • Lee, Sun-kyu;Kim, Soo-Am;Lee, Young-Su
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.121-124
    • /
    • 2005
  • During that time various methods were introduced in the unit planning for the various realization. But the consideration against a variety from the living and functional side still is insufficient. The methods of this study are as follows: 1) Executing domestic instances of being completed above 30 years apartment housing. 2) Case studying the 'Wallgae mansion' in hannam-dong, one of them. Based on the results, this study is analyzed plan variations and the changing points of exterior elevations. The results are as follows: The layout integrated and divided changes composition of units and it is various escaping in the outer wall as the external space being various. Also including the balcony, the spaces with intermediate characteristics much more effect variety of elevations.

  • PDF

An Study on the Sound Attenuation of Audible Fire Alarm Device in Apartment Buildings (공동주택에서의 화재 경보음 전달특성에 관한 연구)

  • Lee, Min-Joo;Kim, Myung-Jun;Yoon, Myong-O
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.658-661
    • /
    • 2005
  • In many fire emergencies, the auditory fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the audible fire alarm worked. This is the first study to show the sound attenuation of audible fire alarm device in apartments. We measured and analyzed the sound attenuation level in seven units. The result showed that it was not sufficient to detect the sound from the fire alarm device in bedrooms. Whether the fire alarm device worked or not, the differences of sound level in bedrooms were below 1$\sim$10dBA. To give the minimum sound level 60dBA in bedrooms, the proper sound levels from alarm device installed in livingrooms were suggested using computer simulation.

  • PDF

Window-to-Wall-Ratio for Energy Reduction in Early Design Stage of Residential Building

  • Lee, Myung Sik
    • Architectural research
    • /
    • v.19 no.4
    • /
    • pp.89-94
    • /
    • 2017
  • In Korea, it is necessary to improve the performance of buildings with respect to the energy efficiency while improving the quality of occupants' lives through a sustainable built environment. During the design and development process, building projects must have a comprehensive, integrated perspective that seeks to reduce heating, cooling and lighting loads through climate-responsive designs. The aim of this study is to assess the optimal window-to-wall ratio of multi-rise residential units in the early design phase in Korea. The study analyzed the variation of annual heating and cooling energy load in two apartment prototype units located in Seoul city using different WWRs. The analysis was conducted using Autodesk Ecotect Analysis 2011 tool. The study found for total annual building load reductions WWR on the south and north face should be studied independently based on the room function. It also found reducing the WWR for bedrooms and windows on the northern façade resulted in reduced total annual building load.