A 8 year old male was admitted to the Department of Thoracic Surgery, Korea University Hospital on June 22, 1978. The chief complaints were cyanosis and exertional dyspnea since at birth. EKG shows BVH and dextrocardia, phonocardiogram revealed the accentuation of second heart sound in aortic area. Echocardiogram from the left ventricle to the base of the heart, there is a discontinuity between the ventricular septum and the anterior aortic margin with a large aortic root & aortic overriding. His cardiac catheterization data and cardiac angiogram shows situs inversus totalis, dextrocardia, right aortic arch, large ventricular septal defect etc., and finally diagnosed Truncus Arteriosus. Edwards type IV with retrograde aortogram and selective bronchial angiogram. This is the first operative case reported as Rastelli operation for Truncus Arteriosus type IV in the literatures in Korea. Authors have experienced I case of Truncus Arteriosus, Edward type IV and Rastelli operation with Dacron Arterial Conduit Graft under cardiopulmonary bypass on July 3, 1978. The procedures were as follows; 2] Cardiopulmonary bypass: Origin of bronchial arteries excised from descending aorta bilaterally; defects in aorta closed. 2] Horizontal incision made high in right ventricle. 2] Ventricular septal defect [Kirklin type I+II] closed with Teflon patch. 4] Bifurcated dacron arterial graft with pericardial monocusp sutured to the bilateral pulmonary arteries. [Diameter 9 mm: Length 7 cm]. 5] Proximal end of the conduit graft anastomosed to right ventricle. [Diameter 19 mm: Length 5 cm]..Total perfusion time was 220 min. The result of operation was poor due to anastomotic leakage and increased pulmonary vascular resistance resulting acute right heart failure. The patient was died on the operation table. Literatures were briefly reviewed.
Background: Despite the excellent early results after the repair of congenital bicuspid aortic valve (BAV) disease, the mid-term durability of the repaired valve has still controversies. Material and Method: To evaluate the mid-term results of BAV repair, retrospective review of medical records and echocardiographic data were done. Between 1994 and 2003, twenty-two patients underwent reparative procedure for either regurgitant or stenotic congenital bicuspid aortic valve (BAV). Result: Mean age was $41\pm14$ years with male predominance (Male=17, Female=5). The pathophysiologies of the BAV were regurgitation-dominant in 20 (91%) and stenosis-dominant in 2 (9%) cases. Various repair techniques were used for raphe, prolapsed leaflet, thickened leaflet, and commissures; 1) release of raphe in 19 (86%), 2) wedge resection and primary repair in 11 (50%), pericardial patch reinforcement after plication of the leaflet in 6 (27%), and plication of the leaflet in 3 (14%), 3) slicing of thickened leaflet was used in 12 (55%) cases, 4) commissuroplasty in 8 (36%), and commissurotomy in 6 (27%) cases. There was no in-hospital mortality. During the mean follow-up of $38\pm17$ months, one patient underwent aortic valve replacement after developing acute severe regurgitation from dehiscence of the suture on postoperative 2 months. New York Heart Association functional class was improved from $1.9\pm0.6$ to $1.2\pm0.5$ (p<0.01). Left ventricular end-systolic and diastolic dimension (LVESD/LVEDD) were also improved from $45\pm9$ and $67\pm10$ to $37\pm10$ and $56\pm10,$ respectively (p<0.01). The grade of aortic regurgitation (AR) was improved from preoperative $(3.1\pm1.2)$ to post-bypass $(0.9\pm0.7).$ However, the grade at last follow-up $(1.7\pm1.1)$ was deteriorated during the follow-up period (p<0.01). Freedom from grade III and more AR at one, three, and four year were 89.7%, 89.7%, and 39.9% respectively. Conclusion: Midterm clinical result of the BAV repair was favorable. But, the durability of the repaired valve was not satisfactory.
Truncus arteriosus with interrupted aortic arch is a very rare congenital cardiac anomaly that has an unfavorable natural course. We report a successful one-stage repair of truncus arteriosus with interrupted aortic arch through median sternotomy in a 25-day-old neonate weighing 3.1 kg. We reconstructed the aortic arch with direct side-to-end anastomosis between ascending and descending aortas. The right ventricular outflow reconstruction was performed with untreated autologous pericardial conduit without valve following Lecompte maneuver. The patient has been grown-up in good condition (25 ∼ 50 percentile of body weight) and shows the right ventricular outflow tract wide 1 year after the operation.
Jo, Jeong Jun;Kim, Yun Seok;Kim, Gun-Jik;Kim, Jae Hyun
Journal of Chest Surgery
/
v.55
no.3
/
pp.243-245
/
2022
True aneurysms of the coronary artery after aortic root replacement in Marfan syndrome patients are very rare. An anomalous origin of the right coronary artery (RCA) from the left sinus of Valsalva adds complexity during aortic root surgery. We present a case of a 37-year-old male patient with Marfan syndrome who had an RCA anomaly and a 4.5-cm true aneurysm of the common coronary button 14 years after a previous Bentall procedure. A redo Bentall operation and hemi-arch replacement were successfully performed. The anomalous origin of the RCA from the left sinus of Valsalva was safely divided and anastomosed as separate coronary buttons to the prosthetic composite valve graft. To prevent coronary button aneurysms after aortic root surgery in Marfan patients, the coronary buttons and the corresponding side holes on the prosthetic graft must be reduced to the maximum possible extent.
A congenital coronary artery fistula is an uncommon anomaly which has a direct communication between a coronary artery and the lumen of any one of the four cardiac chambers, or the coronary sinus, or its tributary veins or the superior vena cava. The right coronary artery is involved most frequently, and the abnormal communication in most often is to the right ventricle followed in incidence by drainage into the right atrium and the pulmonary artery. Recently. we experienced a case of congenital coronary artery fistula associated with valvular heart disease. The fistulous communication was noted between the left circumflex artery and the left atrial appendage. Under the cardiopulmonary bypass, the internal obliteration of the left atrial appendage, mitral valve replacement, and aortic valve exploration were accomplished. Postoperative hospital course was uneventful and the patient was discharged without any problems.
Between Feb. 1990 and Aug. 1993, 180 cases of the open heart surgery were performed under cardiopulmonary bypass in the Department of Thoracic & Cardiovascular surgery, Gil General Hospital. There were 83 cases with congenital heart diseases [CHD] and 97 cases with acquired heart diseases [AHD]. The CHD consisted of 78 acyanotic[mortality: 3.8 %] and 5 cyanotic cases with heart anomaly[mortality:l case]. The AHD were 97 cases, which contained 53 valvular, 27 ischemic heart diseases, 10 aortic diseases, 5 cases with myxoma, 1 case with post-infarct VSD, and 1 case with removal of infected pacing wire in right ventricle. In the 53 valvular heart diseases, there were 45 cases with valve replacement[MVR 27, AVR 9,MVR + AVR 9] and 8 cases with valvuloplasty. The number of the implanted prosthetic valves were 53. In MVR, 25 St. Jude, 6 Sorin, 3 Carpentier-Edward and 2 Intact medical valves were used. In aortic position, 13 St. Jude, 3 Sorin and 1 Intact medical valves were applied. The operative mortality was 5.6 % [3/53]. The annuloplasty applying artificial ring was performed in 17 patients[4 cases associated with MVR] and the number of the implanted ring was 19, which included 14 Duran ring[10 mitral, 4 tricuspid] and 5 Carpentier ring [3 mitral, 22 tricuspid]. In the 27 ischemic heart diseases, there were 9 cases with left main coronary artery lesions, 7 one vessel, 5 two vessels, and 6 three vessels. Average number of anastomosis was 2.8 per patient. The operative mortality was 14.3 % [4/27]. Among the 10 patients with aortic diseases, 7 cases were aortic dissection[type A: 5, type B: 2] and 3 cases were descending thoracic aortic aneurysm. The operative morality occurred in 3 cases. The overall mortality and the operative mortality of congenital and acquired heart disease was 7.8 %, 4.8% and 10.4%, respectively.
The anomaly which the right pulmonary artery originates from the ascending aorta is a rare and usually fatal form of congenital heart disease. This lesion is often associated with a patent ductus arteriosus. Death frequently occurs in early infancy. Anomalous origin of the right pulmonary artery is much more common than anomalous origin of the left pulmonary artery. The anomalous right pulmonary artery usually arise from the posterior aspect of the ascending aorta close to the aortic valve. We report a 1 month-old infant with right pulmonary artery arising from the ascending aorta, which was corrected successfully by direct anastomosis to the main pul onary artery.
The remote location of VSD relative to the aortic valve imposes considerable surgical difficulties in the repair of DORV with noncommitted VSD. We report a successful biventricular repair of the anomaly with VSD rerouting to pulmonary artery followed by arterial switching operation.
Background: Tricuspid valve replacement is very rarely performed procedure and its long-term result is not yet satisfactory. Moreover, it is not well known whether bioprosthesis or mechanical prosthesis is the best selection for artificial valve. We reviewed 72 cases of tricuspid valve replacements in 71 patients between January 1989 and December 1998, trying to analyze the overall results and risk factors for mortality and morbidity. Material and Method: Average age of the patients at the time of operation was 42$\pm$13 years(range 16 to 65 years) and the sex ratio of male versus female was 32/39. Primary diagnosis consisted of 50 cases of aquired valvular heart disease and 18 cases of congenital heart disease, such as Ebstein’s anomaly. 4 cases had isolated tricuspid valve regurgitation. Implanted valves were 69 mechanical prosthesis and 3 bioprosthesis. Concomitant mitral or aortic valve replacements were performed in 50 cases. One patient received concomittant pulmonary valve replacement. Result: There were 7(9.72%) operative deaths and 7(13.0%) late deaths. Actuarial survival at 10 years was 59.2$\pm$7.2%. Prosthetic tricuspid valve thrombosis occurred 11 times in 5 patients. Reoperation for prosthetic tricuspid valve failure was performed in 1 patient. In this case, examination of the explanted prostheses showed that the tricuspid stenosis was the result of valve thrombosis. Among the 47 survivors, 46 patients(98%) were in functional class I or II. Conclusion: In our ten-year experience of tricuspid valve replacement, mortality and morbidity were satisfactory. Mechanical prosthesis in tricuspid position showed comparable clinical results as bioprosthesis.
Background: The purpose of writing this article is to get better clinical results and further clinical improvement based on subject to 110 cases of cardiac surgery which were performed and clinically analyzed. Material and Method: Since January 1995, the patent ductus arteriosus surgery had started in our hospital. In February 1999, an open heart surgery had started and up to September 2000, total of 110 cases were performed as of double ligation of patent ductus arteriosus(10 cases) and open heart surgery(100 cases). Result: Among the patients, Korean-Chines was 74(67.3%) and Han-Chinese was 35(31.8%). Congenital heart disease was 95 cases and acquired valvular heart disease was 15 cases. 83 cases of acyanotic congenital heart disease consisted of ventricular septal defect(VSD) with associated anomaly(45 cases), atrial septal defect(ASD) with associated anomaly(20 cases), patent ductus arteriosus(PDA) with associated anomaly(11 cases), cogenital aortic stenosis(5 cases), double chamber right ventrical(1 case) and Ebstein's anomaly(1 case). Among the 12 cases of cyanotic congenital heart disease, 11 cases of tetralogy of Fallot underwent total correction. Among the 15 cases of acquired valvular heart disease, valvular replacement(7 cases), double valve replacement (3 cases), mitral valve replacement(3 cases) and aortic valve replacement(1 case) were performed. And 8 cases of valvuloplasty were performed by using of commissurotomy, chordal plasty, plasty of papillary muscle, ring type annuloplasty, repair of leaflet. Conclusion: on cogenital heart disease, short term results of surgery for acyanotic cogenital heart disease was good. Among the cyanotic congenital heart disease, tetralogy of Fallot showed a little difference of recovery according to the surgery method so that further follow up observation was needed for long term result. On acquired valvular heart disease, especially, in terms of short term result of valvuloplasty, was relatively good, but further follow up observation was also needed for long term result. There wasn's any operative mortality.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.