• 제목/요약/키워드: Antibody

검색결과 4,159건 처리시간 0.031초

Development of an Immunosensor to Detect Rat IgG Using Impedance Analyser

  • No D. H.;Kang S.;Kim G. Y.;Chung S. H.;Park Y. H.;Om A. S.;Cho S. I.
    • Agricultural and Biosystems Engineering
    • /
    • 제5권1호
    • /
    • pp.21-24
    • /
    • 2004
  • Antibody based biosensors are very selective and ultra-sensitive. Antigen-antibody reactions have been used in immunoassays. In this research, a biosensor which uses antigen-antibody reaction was developed to measure and detect rat IgG. Because the antigen-antibody reaction is a physical bounding between antigen and antibody, there are several ways to measure an antigen-antibody reaction. Among the methods, impedance analysis has short measuring time and possibilities of analyzing various properties of the reaction using frequency analysis. Rat IgG could be detected with developed biosensor and impedance analyzer. The biosensor showed good repeatability and availability of detecting concentration changes of rat IgG.

  • PDF

항체 검사에 의한 Fragile X 증후군의 진단 (Diagnosis of Fragile X Syndrome by Antibody Test)

  • 김강영;윤인숙;김종봉;진동규
    • 생명과학회지
    • /
    • 제9권6호
    • /
    • pp.704-708
    • /
    • 1999
  • This research was carried out for evaluating diagnostic value of antibody test in Fragile X syndrome. In antibody test of control individuals and carriers with a premutation, FMRP were detected in the lymphocytes, whereas the lymphocytes of male Fragile X syndrome patients were devoid of FMRP. Five Fragile X syndrome male patient, two Fragile X syndrome female patients, three carriers were diagnosed by southern blot. Five boys who were diagnosed as the patients by antibody test were turned out full mutation and having multiple smear beside normal single band. However, fragile site of X chromosome was not expressed in Fragile X syndrome patients by chromosome analysis. These results showed that antibody test was a fast and simple method, but the diagnostic power was "perpect" for males, whereas the results were less specific for females.r females.

  • PDF

Enzyme immunoassay(EIA)에 의한 소의 혈중 progesterone 측정과 이의 응용에 관한 연구 I. 이항체(二項體)의 최적조건에 관한 연구 (Studies on enzyme immunoassay for determining progesterone of bovine plasma and its clinical application I. Optimizing double antibody for progesterone in enzyme immunoassay)

  • 강정부;신종욱;최상용
    • 대한수의학회지
    • /
    • 제28권2호
    • /
    • pp.321-325
    • /
    • 1988
  • This experiment was carried out to determine the progesterone concentration of bovine plasma by liquid phase double antibody enzyme immunoassay. The optimum conditions of assay-system, double (first and second) antibody and carrier (normal rabbit serum) were investigated. The optimum dilution rate of first antibody, second antibody and normal rabbit serum was $10{\times}10^3$ to $15{\times}10^3$, 20 and $1{\times}10^3$ times, respectively.

  • PDF

항 GQ1b 항체와 연관된 급성 단독 양안성 내안근마비 1예 (A Case of Acute Isolated Bilateral Internal Ophthalmoplegia Associated with Anti-GQ1b IgG Antibody)

  • 김재하;이경복;노학재;안무영;정두신
    • Annals of Clinical Neurophysiology
    • /
    • 제8권1호
    • /
    • pp.78-80
    • /
    • 2006
  • Miller-Fisher syndrome, Guillain-Barre syndrome with ophthalmoplegia, Bickerstaff s brainstem encephalitis and acute ophthalmoplegia share some clinical features, and common anti-GQ1b IgG antibody and these are introduced as anti-GQ1b antibody syndrome. These syndromes mostly present with paralysis of extraocular muscles and internal ophthalmoplegia rarely occurs. We report a case of acute isolated bilateral internal ophthalmoplegia associated with anti-GQ1b IgG antibody.

  • PDF

정맥용 면역글로불린 투여로 호전된 항-$Di^a$ 항체에 의한 신생아 용혈성 질환 1예 (A Case of Hemolytic Disease of a Newborn by an Anti-$Di^a$ Antibody Treated with Intravenous Immunoglobulin)

  • 이창언;박수진;김원덕
    • Journal of Yeungnam Medical Science
    • /
    • 제30권1호
    • /
    • pp.21-24
    • /
    • 2013
  • Hemolytic disease in a newborn that causes early jaundice is common. It is often due to the Rh (D) and ABO incompatibility, but rarely due to unexpected antibodies. Among these unexpected antibodies, the anti-$Di^a$Dia antibody rarely occurs. The anti-$Di^a$ antibody was observed in the serum and red-cell eluate of an infant, and in the serum of his mother. The frequency of the appearance of the $Di^a$ antigen in the Korean population is estimated to be 6.4-14.5%. This paper reports a case of hemolytic disease in a newborn associated with the anti-$Di^a$ antibody. A full-term male infant was transferred to the authors' hospital due to hyperbilirubinemia the day after his birth. The laboratory data indicated a hemoglobin value of 11.6 g/dL, a reticulocyte count of 10.6%, a total bilirubin count of 14.4 mg/dL, a direct bilirubin count of 0.6 mg/dL, and a positive result in the direct Coombs' test. Due to the identification of an irregular antibody from the maternal serum, an anti-$Di^a$ antibody was detected, which was also found in the eluate made from the infant's blood. The infant had been treated with phototherapy and intravenous immunoglobulin since the second day after his birth and was discharged due to an improved condition without exchange transfusion. Therefore, in cases of iso-immune hemolytic disease in a newborn within 24 hours from birth who had a negative result in an antibody screening test, the conduct of an anti-$Di^a$ antibody identification test is recommended due to the suspicion of an anti-$Di^a$ antigen, followed by early administration of intravenous immunoglobulin.

The p16INK4a Antibody Immobilization Method for Immonosensor Application

  • Yang, Li;Huang, Xian-He;Sun, Liang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권12호
    • /
    • pp.5115-5118
    • /
    • 2015
  • Background: The $p16^{INK4a}$ is a protein that expressed in Liquid-based cervical cytology specimens and has been proved link to cervical cancer. The $p16^{INK4a}$ could be detection by piezoelectric immunosensor and the immobilization of the $p16^{INK4a}$ antibody influence the sensitivity of the piezoelectric immunosensor. Materials and Methods: $5{\mu}L$ mouse polyclonal antibody against $p16^{INK4a}$ was bound onto the surface of immonosensor through two methods. (directly immobilized method; protein A method). Absorb of the $p16^{INK4a}$ antibody on the surface of immonosensor caused a shift in the resonant frequency of the immunosensor and The frequency changes recorded showed a better reproducibility. The activity of the immobilization antibody with the directly method and protein A method was tested with $p16^{INK4a}$ antigen. Results: The resonant frequency for different antibody immobilization methods were different, and the sensitivity for $p16^{INK4a}$ detection also different. Conclusions: The protein A method was found to be much more better than the directly method for the immobilization of the p16INK4A antibody on the gold electrode of the quartz crystal for cervical lesion detection. The Protein A method created more reproducible and stable immobilization antibody layers with p16INK4A antigen.

Affinity Maturation of an Epidermal Growth Factor Receptor Targeting Human Monoclonal Antibody ER414 by CDR Mutation

  • Chang, Ki-Hwan;Kim, Min-Soo;Hong, Gwang-Won;Seo, Mi-Sun;Shin, Yong-Nam;Kim, Se-Ho
    • IMMUNE NETWORK
    • /
    • 제12권4호
    • /
    • pp.155-164
    • /
    • 2012
  • It is well established that blocking the interaction of EGFR with growth factors leads to the arrest of tumor growth, resulting in tumor cell death. ER414 is a human monoclonal antibody (mAb) derived by guided selection of the mouse mAb A13. The ER414 exhibited a ~17-fold lower affinity and, as a result, lower efficacy of inhibition of the EGF-mediated tyrosine phosphorylation of EGFR when compared with mAb A13 and cetuximab. We performed a stepwise in vitro affinity maturation to improve the affinity of ER414. We obtained a 3D model of ER414 to identify the amino acids in the CDRs that needed to be mutated. Clones were selected from the phage library with randomized amino acids in the CDRs and substitution of amino acids in the HCDR3 and LCDR1 of ER414 led to improved affinity. A clone, H3-14, with a ~20-fold increased affinity, was selected from the HCDR3 randomized library. Then three clones, ER2, ER78 and ER79, were selected from the LCDR1 randomized library based on the H3-14 but did not show further increased affinities compared to that of H3-14. Of the three, ER2 was chosen for further characterization due to its better expression than others. We successfully performed affinity maturation of ER414 and obtained antibodies with a similar affinity as cetuximab. And antibody from an affinity maturation inhibits the EGF-mediated tyrosine phosphorylation of EGFR in a manner similar to cetuximab.

소 전염성비기관염(傳染性鼻氣管炎) 바이러스에 대한 monoclonal antibody 생산(生産)과 진단법(診斷法) 개발 II. Monoclonal antibody를 이용한 소 전염성비기관염(傳染性鼻氣管炎)의 진단(診斷) (Application of monoclonal antibody to develop diagnostic techniques for infectious bovine rhinotracheitis virus. II. Diagnosis of infectious bovine rhinotracheitis by using monoclonal antibody)

  • 전무형;김덕환;안수환;이중복;민원기
    • 대한수의학회지
    • /
    • 제29권1호
    • /
    • pp.27-35
    • /
    • 1989
  • To develop more specific and sensitive diagnostic methods for infectious bovine rhinotracheitis, 7-C-2 monoclonal antibody specific to polypeptides of infectious bovine rhinotracheitis virus (IBRV) was applied in indirect immunofluorescence antibody assay (IFA), indirect immunoperoxidase assay(IPA) and radial immunodiffusion enzyme assay (RIDEA). It was found that IBRV infected in MDBK cells could be detected as early as 8 hours post infection by IFA, and that IFA was more rapid and specific to identify IBRV antigen than IPA. The diagnostic efficacy of RIDEA and SN test was studied with 88 bovine sera. It was evident that RIDEA could eliminate the false positive reaction encountered in serum neutralization(SN) test, being more rapid and sensitive than the latter. Highly significant correlation coefficiency (r=0.76, p<0.01) was evaluated between the titers of sera and the diameters of RIDEA. Tracheal membranes and sera collected from 96 slaughtered cattle with lesions in respiratory organs were examined to detect IBRV antigen and antibody by IFA, RIDEA and SN test. It was presented that positive rates were 32.3% in IFA, 20.8% in RIDEA and 21.9% in SN test, and that coincidence rate between RIDEA and SN test were 100% in positive sera and 98.7% in negative sera. In conclusion, it was assumed that application of monoclonal antibody could improve the diagnostic efficacy of IBR by enhancing sensitivity and specificity of IPA, IFA and RIDEA.

  • PDF

직접형광항체법(直接螢光抗體法)에 의한 축산식품중(畜産食品中)의 Salmonella 균(菌) 검출(檢出)에 관한 실험적(實驗的) 연구(硏究) (Experimental Studies on Detection of Salmonellae in Animal-origin Foods by Means of Dirct Fluorescent Antibody Technique)

  • 전무형;차연호;정길택
    • 대한수의학회지
    • /
    • 제14권2호
    • /
    • pp.243-252
    • /
    • 1974
  • The experiment was performed in order to investigate the applicability of the rapid detection of salmonellae in various animal-origin foods by means of the direct fluorescent antibody technique. Egg, sausage and chicken were inoculated with various concentrations of Sal.paratuphi A, Sal. paratyhi B and Sal. thompson, and the fluorescent antibody technique was applied and compared with the conventional cultura method for the sensitivity of detection of the organisms. Two methods were employed in the fluorescent antibody technique; the direct smear method in which the smear being made directly from the specimens, and the enrichment smear method in which the smear being made from the enrichment broth. The effect of various enrichment time (1,5,8,11 and 13 hours) in tetrathionate broth on the detection of salmonellae in the fluoresent antibody technique was also studied. The results obtained were summarized as followings; 1. Of the three methods, the enrichment smear method of fluorescedt antibody technique was highly effective as cultural method for the detection of salmonella organisms. 2. Direct smear method of fluorescent antibody technique was effective as two other methods $5{\times}10^4$ organisms presented in 50 g(ml) of specimens. This method may not be applicable when the specimens contained $5{\times}10^2$ or less organisms. 3. Of the three specimens, the recovery rate of Salmonella organisms from egg was slightly higher than that of sausage and chicken. 4. In fluorescent antibody technique and cultural method, the specimens inoculated with Sal. thompson were found to be higher detection rate than the specimens inoculated with Sal. paratyphi A, 5. The optimum enrichment time of Salmonella organisms in tetrathionate broth on the detection by fluorscent antibody technique was found to be 11 hours or longer when the specimens of egg, sausage and chicken were inoculated with approximately 500 organisms. The longer enrichment time was the higher detection rate up to 11 hours tested.

  • PDF

하이브리도마 세포의 유가식 배양에서 배지첨가속도가 단일클론 항체 생산에 미치는 영향 (The Effect of Media Feeding Rate on the Production of Monoclonal Antibody Production in the Fed-batch Culture of Hybridoma)

  • 곽원재;최태부;박정극
    • 한국미생물·생명공학회지
    • /
    • 제19권3호
    • /
    • pp.272-280
    • /
    • 1991
  • 유가식 배양에서 배지첨가속도가 하이브리도마 세포의 증식과 항체생성속도에 미치는 영향을 조사하였다. 항체 비생성속도 $q_p$값이 변화는, 회분식 배양의 경우 배양 초기에 가장 높았다가 계속 감소하는 경향을 보였으나, 배양 48시간 이후부터 배지의 첨가가 시작되는 유가식 배양에서는 qp 값이 배지 첨가직후 부터 빠른 속도로 증가하기 시작해 배양이 끝날 때까지 높은 값으로 유지되었다. 그리고 배지의 비첨 가속도 $q_f$가 증가되면서 항체의 비생성속도 $q_p$도 민감하게 증가하는 경향을 보였다. 생성된 최종 항체농도 $C_{final}$은 배지 첨가속도에 비해 큰 영향을 받지 않고 거의 비슷한 값을 보였지만 평균적으로 회분식 배양보다는 그 값이 3배 이상 증가되어 최고 220$\mu g$/ml까지 향상되었다.