• Title/Summary/Keyword: Anti-icing system

Search Result 19, Processing Time 0.024 seconds

The Study of FAA's certification policy for approving the ground use of deicing/anti-icing fluids on airplane (항공기용 결빙방지액의 지상 사용승인을 위한 FAA의 최근 인증정책 연구)

  • Kim, You gwang
    • Journal of Aerospace System Engineering
    • /
    • v.7 no.3
    • /
    • pp.51-57
    • /
    • 2013
  • This study describes the Federal Aviation Administration(FAA) certification policy for approving the use of Type II, III, and IV deicing/anti-icing fluids on small category airplanes. These fluids can be characterized as non-Newtonian, pseudo-plastic fluids, also known as "thickened" fluids. Deicing fluids are used before takeoff to remove frost or ice contamination, while anti-icing fluids are used before takeoff to prevent frost or ice contamination from occurring for a period of time(referred to as "holdover time") after application. Thickened deicing/anti-icing fluids can affect airplane performance and handling characteristics and their residue may cause stiff or frozen flight controls. This study also describes an approval process that may be used by type certificate holders and applicants for a type certificate under parts 23 to support operational use of these fluids on their airplanes.

A Study on Anti-Icing Technique for Ballast Water of Icebreaking Vessels Operating in Ice-Covered Water (극지운항용 빙해선박의 밸러스트 수 결빙방지 기법 연구)

  • Jeong, Seong-Yeob;Lee, Chun-Ju;Cho, Seong-Rak
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.1
    • /
    • pp.93-97
    • /
    • 2011
  • When freezing is present on ballast water, it can impose additional loads on the hull and effect on stabilization of ship. The anti-icing techniques of ballast water, therefore, are key criteria for ship safety. The existing anti-icing techniques of ballast tank are hull heating, water circulation and air bubble system etc. In this research, anti-icing performance tests for the ballast water using micro-bubble system and sea water circulation system have been carried out at two temperature conditions($-10^{\circ}C$ and $-25^{\circ}C$). Ambient temperature, sea water temperature and temperature of the inner parts of the ballast tank are measured and also ballast water conditions are checked during the model test. The applied anti-icing techniques of ballast water, such as micro-bubble system and sea water circulation system show good performance in the low temperature conditions.

Prioritization of Anti-Icing Spray System for Active Snow-Removal Works (능동적 제설작업을 위한 염수분사장치 설치 우선순위 선정)

  • Yang, Choong Heon;Kim, In Su
    • International Journal of Highway Engineering
    • /
    • v.17 no.4
    • /
    • pp.99-105
    • /
    • 2015
  • PURPOSES: This study aims to establish the priority of introducing anti-icing spray system for regions of the National Highways in South Korea. Using this study, a logical plan for instituting such an anti-icing spray system can be established for the National Highways. METHODS : The Analytical Hierarchy Process (AHP) was employed to prioritize the implementation of an anti-icing spray system on Korean highways. For this purpose, an existing scoring table developed by the Ministry of Land, Infrastructure Transport Affair was slightly modified in order to reflect recent trends in winter maintenance. A survey was conducted to gather the preferences regarding the developed hierarchy of road experts and agencies. Finally, the final score was produced by integrating the scoring results with estimated weights for each evaluation criterion. RESULTS: In general, Honam and the metropolitan areas have relatively high priority while other areas such as Chungcheong, Young Nam, and Gang Won appear to be uniform in importance in terms of establishing an anti-icing spray system. This result may indicate that historical weather data and traffic volumes are significant factors in deciding in winter maintenance polices CONCLUSIONS : In this study, useful insights are suggested regarding winter maintenance by simultaneously performing rapid snow removal and proactive treatment. Issues of resource allocation may be potential research items in the field transportation engineering.

Analysis of the Influence of Anti-icing System on the Performance of Combined Cycle Power Plants (가스터빈 결빙방지 시스템이 복합화력발전 시스템의 성능에 미치는 영향)

  • Moon, Seong Won;Kim, Jeong Ho;Kim, Tong Seop
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.6
    • /
    • pp.19-25
    • /
    • 2016
  • Anti-icing is important in gas turbines because ice formation on compressor inlet components, especially inlet guide vane, can cause performance degradation and mechanical damages. In general, the compressor bleeding anti-icing system that supplies hot air extracted from the compressor discharge to the engine intake has been used. However, this scheme causes considerable performance drop of gas turbines. A new method is proposed in this study for the anti-icing in combined cycle power plants(CCPP). It is a heat exchange heating method, which utilizes heat sources from the heat recovery steam generator(HRSG). We selected several options for the heat sources such as steam, hot water and exhaust gas. Performance reductions of the CCPP by the various options as well as the usual compressor bleeding method were comparatively analyzed. The results show that the heat exchange heating system would cause a lower performance decrease than the compressor bleeding anti-icing system. Especially, the option of using low pressure hot water is expected to provide the lowest performance reduction.

Study about the Evaluation of Freezing Risk Based Road Surface of Solar Radiation (도로 노면 일조량에 따른 결빙 위험도 평가 방법에 관한 연구)

  • Lee, Dong-Hyun;Jeong, Won-Seok;Kim, Hong-Jin;Kim, Jiwon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.130-135
    • /
    • 2013
  • Anti-icing system can reduce traffic accidents and congestion by quickly removing the frozen road surface area. there is no decision criteria for determining application of the Anti-icing system in Korea. In this study, we proposed the decision criteria for determining application of the anti-icing system based on weather and road conditions, i.e., geometric and topographic conditions. Regional climate survey, Solar Radiation analysis, and dynamic vehicle simulation considered road geometry was conducted to standardize the installation method of anti-icing system. Also, we have developed a software that can be determined an installation of anti-icing system.

Study about the Standard of Anti-icing System Based on Geography and Geometric Designs (기하구조 및 지형적 요소를 고려한 융설시스템 설치 기준 정립에 관한 연구)

  • Lee, Dong-Hyun;Jeong, Won-Seok;Kim, Ji-Won;Ko, Seok-Beom
    • International Journal of Highway Engineering
    • /
    • v.13 no.2
    • /
    • pp.95-102
    • /
    • 2011
  • Anti-icing system can immediately respond when snowing is expected or the snow comes down on the road surface. It has been recognized that the system can reduce traffic accidents and congestion by quickly removing the frozen road surface area. However, it is very difficult to implement this system due to the expensive equipment installation and operation cost, Recently, there was a developed program for predicting the freezing area using three-dimensional model and tracking the sun path. But, there is no objective analysis method and all developed approaches are different so that the general standard of anti-icing system is needed. In this study, we proposed the decision criteria for determining application priorities of the anti-icing system based on weather and road conditions, i.e., geometric and topographic conditions. Regional climate survey, topographical analysis, and dynamic vehicle simulation considered road geometry and skid resistance was conducted to standardize the installation method of anti-icing system.

Study for Certification of Aircraft De-icing System (항공기 제빙 시스템의 인증에 대한 연구)

  • Jun, Jonghyub
    • Journal of Aerospace System Engineering
    • /
    • v.6 no.2
    • /
    • pp.7-12
    • /
    • 2012
  • De-icing system is essential for any aircraft to fly in icing conditions. So there are two kinds of aircraft-those that are certificated for flight in icing conditions and those that are not. Icing certification involves a rigorous testing program, and relatively few light aircraft carry this approval. From a legal perspective, aircraft that do not have all required ice protection equipment installed and functional are prohibited from venturing into an area where icing conditions are known. There are a few kinds of de-icing system. It is necessary to review the systems in point of aircraft certification considering the operational and safety issues.

Properties of De/Anti-icing Fluid for High Speed Railway Rolling Stock Based on Propylene-glycol Containing Water Repellent Agent (발수 성분을 포함하는 프로필렌글리콜(PG) 기반 고속철도차량용 제·방빙액의 특성)

  • Jin-Myeong, Park;Tae-Hyun, Kim;Jung-Mu, Yang;Cha-Jung, Yun;Hong-Ki, Lee
    • Applied Chemistry for Engineering
    • /
    • v.34 no.1
    • /
    • pp.69-74
    • /
    • 2023
  • As a chemical de-icing method, propylene glycol de-icing fluid is applicable for melting ice caused by snow and ice adhering to the lower part of high-speed rail rolling stock and bogie parts in winter. By spraying propylene-glycol de-icing fluid on high-speed rail rolling stock and bogie parts in advance to minimize snow adhesion, ice-melting efficiency can be further improved. In the case of high-speed rail rolling stock, even if propylene-glycol de-icing fluid is sprayed, the anti-icing performance is poor because the fluid is almost lost on the surface of the vehicle when operating at high speed. In this study, in order to prevent freezing caused by snow and ice adhering to the lower part of high-speed rail rolling stock and bogie parts, we have investigated the properties of propylene-glycol de/anti-icing fluid containing water-repellent agents that prevent surface freezing. We tried to find the optimal component for de/anti-icing fluid for high-speed rail rolling stock by evaluating the ice melting performance, contact angle, and anti-icing performance according to the types of water-repellent agent. As a result of the evaluation, it was confirmed that an de/anti-icing fluid containing an ethoxysilane-type water repellent agent was most suitable.

Icing Characteristics in Liquid-Phase Injection of LPG Fuel (액상분사식 LPG 인젝터의 아이싱 생성 특성 및 억제 방법)

  • Lee, Sun-Youp;Kim, Chang-Up;Choi, Kyo-Nam;Kang, Kern-Yong
    • Journal of ILASS-Korea
    • /
    • v.14 no.4
    • /
    • pp.147-152
    • /
    • 2009
  • Since a liquid-phase LPG injection system allows accurate control of fuel injection and increase in volumetric efficiency, it has advantages in achieving higher engine power and lower emissions compared to the mixer type LPG supplying system. However, this system also leads to an unexpected event called icing phenomenon which occurs when moisture in the air near the injector freezes and becomes frost around the nozzle hole due to extraction of heat from surrounding caused by instant fuel vaporization. As a result, it becomes difficult to control air/fuel ratio in engine operation, inducing exacerbation of engine performance and HC emission. One effort to mitigate icing phenomenon is to attach anti-icing injection tip in the end of nozzle. Therefore, in this study, the effect of engine operation parameters as well as surrounding conditions on icing phenomenon was investigated in a bench test rig with commercially-used anti-icing injection tips. The test results show that considerable ice was deposited on the surface near the nozzle hole of the anti-icing tip in low rpm and low load operating conditions in ambient air condition. This is because acceleration of detachment of deposited ice from the tip surface was induced in high load, high rpm conditions, resulting in decrease in frost accumulation. The results of the bench testing also demonstrate that little or no ice was formed at surrounding temperature below a freezing point since the absolute amount of moisture contained in the intake air is too small in such a low temperature.

  • PDF

Investigation of the Performance of Anti-Icing System of a Rotorcraft Engine Air Intake (회전익기 공기흡입구 주위 방빙장치 성능 해석)

  • Ahn, Gook-Bin;Jung, Ki-Young;Jung, Sung-Ki;Shin, Hun-Bum;Myong, Rho-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.4
    • /
    • pp.253-260
    • /
    • 2013
  • Ice accretions on the surface around a rotorcraft air intake can deteriorate the safety of rotorcraft due to the engine performance degradation. The computational simulation based on modern CFD methods can be considered extremely valuable in analyzing icing effects before exact but very expensive icing wind tunnel or in-flight tests are conducted. In this study the range and amount of ice on the surface of anti-icing equipment are investigated for heat-on and heat-off modes. It is demonstrated through the computational prediction and the icing wind tunnel test that the maximum mass and height of ice of heat-on mode are reduced about 80% in comparison with those of heat-off mode.