• 제목/요약/키워드: Anti-freezing

검색결과 117건 처리시간 0.024초

빙해선박 상부갑판 열선의 열전달 특성에 따른 착빙방지 성능평가 및 설계기준에 관한연구 (A Study on the Anti-Icing Performance Evaluating and Design Guide by Heating Coil for Upper Deck of Icebreaking Vessels)

  • 이종찬;서영교;이춘주
    • 대한조선학회논문집
    • /
    • 제49권6호
    • /
    • pp.541-549
    • /
    • 2012
  • The study adopted a freezing prevention method of the upper deck which used heating coil, and carried out numerical analysis by using ANSYS 13.0 CFD for design guide of the vessel operating in cold region. It is based on the experimental results of the anti-icing performance tests which were carried at cold room chamber in MOERI. Numerical analysis for the design guide was performed by considering S.S.T. (Shear Stress Transport) turbulent model for flow separation effects and the turbulence which occurred in interfaces of the numerical model in order to express appropriate heat transmission phenomenon. The numerical result shows average temperature of the upper deck surface appeared similarly compared with the indoor chamber test. The design guide for optimum freezing prevention presented through heat transmission capability and interval of the heat coil in various outdoor temperature($10^{\circ}C{\sim}-30^{\circ}C$) and wind speed(1m/s~7m/s).

극저온 고압액체수소 공급을 위한 실험실 규모 인쇄기판 열교환기의 복합열전달 해석을 통한 방빙설계에 관한 연구 (A Study on Anti-Icing Design by Conjugate Heat Transfer Analysis in a Lab-Scale Printed Circuit Heat Exchanger for Supply of Cryogenic High Pressure Liquid Hydrogen)

  • 손상호;김우경
    • 한국수소및신에너지학회논문집
    • /
    • 제33권5호
    • /
    • pp.541-549
    • /
    • 2022
  • This study investigates anti-icing design by conjugate heat transfer analysis in lab-scale printed circuit heat exchanger (PCHE) for supply of cryogenic high pressure liquid hydrogen. The conjugate heat transfer analysis by using computational dynamics (CFD) provided various temperature distributions at important locations in PCHE heat exchanger and predicted the possibility of freezing in hot channel. And, the effect of inlet temperature of glycol water was analyzed in order to resolve the freezing problem in PCHE.

동상모형실험을 통한 아스팔트 포장체의 동결 및 처짐 특성 (Freezing and Deflection Characteristics of Flexible Pavement Structure Using Frost Model Test)

  • 신은철;황순갑;박정준
    • 한국지반신소재학회논문집
    • /
    • 제11권3호
    • /
    • pp.27-35
    • /
    • 2012
  • 본 논문에서는 $-20^{\circ}C{\sim}10^{\circ}C$의 온도 유지가 가능한 길이 3.2m, 폭 3.2m, 높이 2.4m의 대형 냉동고 내부에 길이 0.9m, 폭 0.9m, 높이 0.9m의 실험용 토조를 실제 도로 아스팔트 포장체의 형상과 유사하게 구성하여 실험 조건에 따른 시료 깊이별 온도변화, 동상 팽창압, 팽창량 등 도로의 동결 특성을 분석하였다. 또한, 소형충격재하 장치(LFWD)를 활용하여 동결 전과 융해 후 도로포장구조체의 동상방지층 유무에 따른 실험을 실시하여 아스팔트 포장체 표면의 처짐을 측정하였다. 즉, 도로포장 중앙부의 처짐비와 표층곡률지수비를 분석, 평가함으로써 도로동상방지층의 효용성 및 공용성을 규명하였다.

현장계측 데이터를 이용한 일평균 대기온도 산정방법과 동상방지층 설계를 위한 동결지수 보정 (Computing Procedure of Daily Average Air Temperature using Field Data and Frost Index Calibration for Anti-Frost Heave Layer Design)

  • 조명환;김낙석;심재필
    • 대한토목학회논문집
    • /
    • 제31권3D호
    • /
    • pp.433-439
    • /
    • 2011
  • 도로의 동상방지층을 설치하기 위하여 동결심도(동결관입깊이)를 산정하는데, 동결지수는 $0^{\circ}C$ 이하의 기온과 영하온도의 지속시간을 곱한 값을 연간을 통하여 누계한 수치로 표시된다. 따라서, 일평균 대기 온도를 구하는 방법이 동결지수에 영향을 미칠 수 있다. 기상청의 경우 1999년을 기점으로 이전에는 1일 4회 평균 대기온도 제공하였으며, 현재는 1일 8회 평균 대기온도를 제공하고 있다. 본 연구에서는 이러한 일평균 대기온도를 산정하는 방법이 동결지수의 산정결과에 미치는 영향을 확인하기 위하여 한반도 남부(동결지수 $350^{\circ}C{\cdot}$일 미만) 6개 지역을 현장조건(저성토부, 절성경계부 및 절토부)에 따라 구분하여 15개소에 대하여 현장계측시스템을 구축하였다. 그리고 현장계측시스템으로부터 얻어진 대기온도를 통하여 동결지수를 산정하고 상호 비교분석 하였다. 비교분석 결과 일반적으로 1일 4회 평균 대기온도를 사용한 경우가 1일 8회 평균 대기온도를 사용하는 경우보다 약 3% 전후 큰 것으로 나타났으며, 본 연구 지역에 대한 동결지수를 결정할 때 동결지수를 보정할 수 있는 보정식을 제안하였다.

기하구조 및 지형적 요소를 고려한 융설시스템 설치 기준 정립에 관한 연구 (Study about the Standard of Anti-icing System Based on Geography and Geometric Designs)

  • 이동현;정원석;김지원;고석범
    • 한국도로학회논문집
    • /
    • 제13권2호
    • /
    • pp.95-102
    • /
    • 2011
  • 융설액 분사 시스템은 강설이 예상되거나 진행 중인 상황에서 즉시 대응이 가능하며, 강설 초기에 효율적인 처리로 강설로 인해 발생 가능한 교통사고와 교통 지정체를 감소시킬 수 있는 장점을 가지고 있다. 그러나 시스템의 설치비용이 고가이고, 설치되는 장비의 종류에 따라 운영 및 유지관리 비용이 지속적으로 소요되기 때문에 모든 도로 구간에 설치하는 것은 현실적으로 불가능하다. 최근 국내에서는 결빙 위험 구간을 파악할 수 있는 프로그램들이 개발되어 턴키 및 대안 설계에 활용되고 있다. 그러나 프로그램 개발 업체들마다 분석 방식이 상이하고 객관적인 기준이 없는 실정이다. 이에 따라 융설시스템 적용구간에 대한 기준 마련도 시급하다고 볼 수 있다. 본 연구에서는 선형, 기상조건, 일조조건 등을 다양한 도로 조건을 정량화하여 어떤 구간에 우선적으로 융설시스템을 적용하여야 하는지 판단할 수 있는 기준을 제시한다. 이를 위해 국내 지역별 기상 조사, 지형지물에 의해 음지 발생 여부 분석, 선형과 미끄럼 저항성을 고려한 차량 시뮬레이션 등을 수행하고 이론적 검토를 통해 설치 기준 방법론을 정립하는데 중점을 둔다.

초소수성 발수제를 사용한 모르타르 표면의 결빙 방지 효과 (Anti-freezing effect of mortar surface with superhydrophobic water repellent)

  • 김상진;인병은;강석표
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.15-16
    • /
    • 2022
  • In order to examine the adhesion characteristics of road pavement according to environmental conditions, the freezing time of cement mortar and the adhesion performance between ice and pavement were evaluated depending on the presence or absence of polymer and water repellent. As a result of measuring the ice formation time, it was found that there was no delay when a polymer was added, but the complete freezing time was delayed when a water repellent was added. As a result of measuring the strength of ice adhesion, it was found that the bonding force between ice and the surface of the test body was greatly generated in the test body without water repellent. In the case of a test specimen to which a water repellent was added, it was found that the bonding strength between the test specimen surface and ice was reduced.

  • PDF

한중콘크리트에 있어서 폐부동액을 이용한 내한제의 효율성에 관한 기초적 연구 (A Fundamental Study on the Effectiveness of Anti-freeze Agent Using Waste Coolant in Cold Weather Concreting)

  • 김경민;원철;김기철;오선교;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.231-236
    • /
    • 2001
  • In this paper, tests are carried out in order to investigate the validities of anti-freeze agent, which is developed using waste coolant and existing anti-freeze agent through previous study, under various W/C and contents. According to test results, adequate dosage of developed anti-freeze agent shows positive performance in slump, air content and chloride contents in the mixture of 40% and 50% of W/C, accelerates setting time and drops the freezing temperature of concrete. Meanwhile, in the region of 30% of W/C, followings can be indicated that increasing the contents of anti-freeze agent leads to reduce fluidity, rapid setting and excessive chloride contents. Improved strength gain is shown when anti-freeze agent is used with in 8%.

  • PDF

초기함수비, 비표면적, 풍건 및 동결.융해작용이 흙의 액성한계에 미치는 영향 (Influence of Initial Water Content, Specific Surface, Air Drying and Freezing-thawing Action on the Liquid Limit of Soils)

  • 류능환
    • 한국농공학회지
    • /
    • 제38권5호
    • /
    • pp.116-124
    • /
    • 1996
  • The purpose of The work described in this paper is to clear up the initial moisture content, specific surface, air drying and freezing-thawing process on liquid limit of clayey soils distributed widely at estuary of three main rivers in the west coast. To this end, a series of tests were conducted on clayey soils samples with natural state and treated state. From the test results, the liquid limit was decreased with decrement of initial moisture content, air drying process, and freezing-thawing cycles and increased with increment of specific surface. The specific surface which influenced on the liquid limit is over $25 m^2$m$^2$/g, and their relationships are well formulated. Air drying process is expected to improve the engineering properties of the soils such the pro-water properties were changed to anti-water proper-ties through lowering of water holding as resulted to incline from A-7-5 to A-5 on the soil classificaction plastic chart. The freezing-thawing process decreased 20% of liquid limit, especially under the first cycle of the behavious, as a result of above mentioned reasons, phase change of soil-water system brought the decrement of specific surface and affected to the liquid limit.

  • PDF

CRM 개질아스팔트 혼합물의 소성변형 및 박리저항 특성 (Evaluation of Stripping and Rutting Properties of CRM Modified Asphalt Mixtures)

  • 도영수;박태원;김현환;김광우
    • 한국도로학회논문집
    • /
    • 제9권4호
    • /
    • pp.149-158
    • /
    • 2007
  • 본 연구는 산업부산물인 폐타이어인 #30 체를 거의 다 통과한 CRM 입자를 아스팔트 콘크리트 혼합물의 개질재로서 8%, 10%, 12%를 각각 습식 및 건식방법의 CRM 개질아스팔트 혼합물에 대하여 동결융해에 의한 수분취약성 시험을 통하여 동결융해저항성을 평가하였다. 건식 및 습식방법에 의한 CRM 개질아스팔트 혼합물의 배합설계를 통하여 최적아스팔트 함량을 결정하였고. OAC로 제조한 CRM 개질 혼합물은 반복주행시험과 수분취약성시험을 수행하였다. 그 결과, CRM 개질아스팔트 혼합물의 소성변형 저항성은 일반 AP-5 혼합물보다 우수하게 나타났다. 그러나 수분취약성시험에 의한 동결융해 저항성이 상당히 낮게 나타나 동결융해에 의한 수분취약성에 아주 민감한 것으로 나타났다. 반면에, CRM 개질아스팔트 혼합물에 박리저감제의 첨가는 동결융해에 의한 수분취약성에 대한 저항성을 상당히 향상시키는 것으로 나타났다. 따라서 국내에서 CRM 개질아스팔트 혼합물을 사용할 때에는 반드시 수분취약성에 대한 동결융해저항성에 대한 예방책이 제시된 혼합물을 사용될 것이 권장된다.

  • PDF