A Study on the Smoke Hazard Increase of Flame-retardant-treated Interior Decorative Textile -Focused on Viscose Rayon Textile Wallcovering- (난연 처리된 실내장식섬유의 연기 위해성 증가에 관한 연구 -비스코스 레이온 섬유 벽지를 중심으로-)

  • Lee, Joonhan;Kim, Sun Mee
    • Journal of Fashion Business
    • /
    • v.24 no.3
    • /
    • pp.30-39
    • /
    • 2020
  • This study was conducted to identify problems in domestic flame-retardant performance specifications. Currently, the domestic wallcovering anti-inflammatory regulations are not prepared for damage caused by smoke, with the carbonized area as the main function. In particular, given that smoke is the main cause of human casualties and injuries in a fire, it is reasonable that the flame density and toxicity of the wallcovering should also be the main performance indicators. The scope and method of research in this study were as follows. First, a prior study related to fire on various wallcoverings was considered. Second, it raised questions about the effects of smoke in the event of a fire and domestic anti-inflammatory performance tests. Third, textile wallcovering samples were manufactured with viscose rayon for experimental verification of the problems and tested by Korean and EU standards without flame retardant processing to analyze the differences between each regulation. Fourth, the performance of flame retardant wallcovering according to Korean standards was evaluated using smoke density and harmful gas testing methods. The results of each test were as follows. Non-fire retardant wallcovering was rejected by Korea standards. However, B-s1.d0 in Europe. Smoke density testing and harmful gas by domestic combustion processing on the same sample showed that the smoke density increased about 4.3 times more than before, and the harmful gas test showed that the suspension of the post-processing sample slowed earlier than the non-processed sample.

A Study on the Safety Facilities of Urban Railway (I) (도시철도 선로안전시설에 관한 고찰(I))

  • Lee Seong-Won;Kim Seung-Hwan;Shin Seung-Kyo;Kim Hong-Seuk
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1150-1155
    • /
    • 2004
  • In this paper, safety requirements for guard rails, buffer stops, defensive structures, anti-fire facilities, and safety sidings are studied to establish a standard. Various kinds of guard rails and their construction methods are investigated. Researches on the level difference of main track and guard rail, joint. length, and fastening force of guard rail are done. The classification of buffer stops, defensive structures, anti-fire facilities, and safety sidings and its characteristics are examined. From this study, fundamental data on the safety facilities of urban railway system are established.

  • PDF

Study on the Development of Optical Sensor Linear Fire Detection System Using Raman Scattering (라만산란을 이용한 광센서 선형 화재감지시스템 개발에 관한 연구)

  • Lee, Gun-Ho;Lim, Woo-Sub;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.27-38
    • /
    • 2016
  • The paper reports the development of a distributed temperature sensing (DTS) system, which is a fire detection system using optical sensor linear detectors that depends on foreign and domestic technologies. This study accordingly analyzed the electrical signal patterns of Raman scattering light mainly used for temperature sensing among back-scattered light generated in optical fiber by using an oscilloscope. Through the measurement results, it could be verified that the Stokes signal patterns had little change by the temperature increase, but the temperature-sensitive anti-Stokes patterns had relative increase of the changes. This study developed a K-DTS system, which is an optical sensor linear fire detection system composed of an optical repeater and a receiver that can detect fires using Raman scattering light. It could be verified that the developed K-DTS system satisfied the type approval standards through the sensitivity tests using the rate of rise type and fixed temperature type sensitivity testers. In addition, performance experiments have been performed for performance evaluation of the K-DTS system developed in comparison with S-DTS system which has been imported from abroad and widely used in Korea. It can be confirmed from the results of the performance experiments using model tunnels that comparable performances can be obtained in fire detection locations and the measurements of fire temperatures.

The System Position from High Firing Rate of Anti-Aircraft Gun system (고발사율 대공포 발사에 따른 체계자세 연구)

  • Hwang, Boo Il;Lee, Boo Hwan;Kim, Chi Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.6
    • /
    • pp.611-615
    • /
    • 2015
  • Anti-aircraft gun system is used for low-level air defense system and has more than twin guns with high firing rate in order to maximize the capability of defense. Gun's vibration and bullet's variance has a critical effect on accuracy and hit probability of weapon system such as anti-aircraft gun system with high firing rate. Typical mechanism to reduce the amount of vibration and shock during gun-fire process is very important design factor. In this paper, the suspension characteristics of the vehicle are studied for the improvement of isolating performance of gun firing system with high firing rate. Gun fire test for the vehicle is conducted and computational models using Recurdyn and Adams are created based on test results. Through this study, results of computational analysis are compared with the real test results, which includes type, location and quantity of suspension and gun mechanism are selected for anti-aircraft gun. From the result of this study, we could make basic design and consider the proper component of the system such as suspension and gun spring.

Comparison of the Effects of Straight and Twisted Heat Trace Installations Based on Three-dimensional Unsteady Heat Transfer (열선의 직선시공과 감기시공의 동파방지 효과 비교를 위한 3차원 비정상 수치해석)

  • Choi, Myoung-Young;Jeon, Byoung-Jin;Choi, Hyoung-Gwon
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.49-56
    • /
    • 2016
  • This paper numerically examines, straight and twisted electrical heat trace installations for their anti-freezing effects on water inside a pipe. The unsteady incompressible Navier-Stokes equations coupled with an energy equation were solved to compare the two installation methods. The heat conduction of the pipe with a heat source interacts with the natural convection of the water, and the conjugate heat transfer was considered using a commercial code (ANSYS-FLUENT) based on a SIMPLE-type algorithm. Numerical experiments, were done to investigate the isotherms and the vector fields in the water region to extract the evolutions of the minimum and maximum temperatures of the water inside the pipe. There was no substantial difference in the anti-freezing effects between the straight and twisted. Therefore, the straight installation is recommended after considering the damage and short circuit behavior of the electrical heat trace.

A Method for Eliminating Aiming Error of Unguided Anti-Tank Rocket Using Improved Target Tracking (향상된 표적 추적 기법을 이용한 무유도 대전차 로켓의 조준 오차 제거 방법)

  • Song, Jin-Mo;Kim, Tae-Wan;Park, Tai-Sun;Do, Joo-Cheol;Bae, Jong-sue
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.47-60
    • /
    • 2018
  • In this paper, we proposed a method for eliminating aiming error of unguided anti-tank rocket using improved target tracking. Since predicted fire is necessary to hit moving targets with unguided rockets, a method was proposed to estimate the position and velocity of target using fire control system. However, such a method has a problem that the hit rate may be lowered due to the aiming error of the shooter. In order to solve this problem, we used an image-based target tracking method to correct error caused by the shooter. We also proposed a robust tracking method based on TLD(Tracking Learning Detection) considering characteristics of the FCS(Fire Control System) devices. To verify the performance of our proposed algorithm, we measured the target velocity using GPS and compared it with our estimation. It is proved that our method is robust to shooter's aiming error.

A Study on the Anti-Spalling Performance of High-Strength Concrete Members by covered Engineered Cementitious Composite (ECC로 피복된 고강도콘크리트 부재의 폭렬억제성능에 관한 연구)

  • Lee, Jae-Young;Kim, Jae-Hwan;Han, Byung-Chan;Park, Sun-Gyu;Kwon, Young-Jin
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.85-94
    • /
    • 2008
  • The purpose of this study is to obtain the fundamental fire resistance performance of engineered cementitious composites (ECC) under fire temperature in order to use the fire protection material in high-strength concrete structures. The present study conducted the experiment to simulate fire temperature by employing of ECC and investigated experimentally the explosion and cracks in heated surface of these ECC. In the experimental studies, 5 HSC specimens are being exposed to fire, in order to exami ne the influence of vari ous parameters (such as depth of layer=20, 30, 40 mm; construction method=lining and repairing type) on the fire performance of HSC structures. Employed temperature curve were ISO 834 criterion (3 hr), which are severe in various criterion of fire temperature in building structures. The numerical regressive analysis and proposed equation to calculate ambient temperature distribution is carried out and verified against the experimental data. By the use of proposed equation, the HSC members subjected to fire loads were designed and discussed.

An Experimental Study on the Fire Risk of Electric Heaters According to Contact of Flammable Materials (가연물 접촉에 따른 전기히터의 화재위험성에 관한 실험적 연구)

  • Lee, Sung-Ryong
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.63-71
    • /
    • 2011
  • In this study, it was evaluated the fire risk of an electric heater as representative seasonal appliances. Two type of electric heaters were used in experiments. When electric heaters were operated, temperature variation was measured around the heater. Internal structure was understood by Nondestructive inspection. It was evaluated the tire risk of electric heaters, when flammable materials were positioned ear a heater. It was also estimated the probability of a tire in case of malfunction of a safety tip-over witch. When a heater was operated in a normal condition, temperature was maintained under $80^{\circ}C$ around the heater. The possibility of a fire is very high, when a heater is covered with flammable materials or malfunction of safety parts (safety tip-over switch, anti-overheating devices).

Research of Traditional Herbal Medicines for Anti-inflammatory Effects - Focusing on in vitro experiments - (항염증 효능을 가진 한약물에 관한 고찰 - 시험관내 실험을 중심으로 -)

  • Lee, Soo-Jin
    • Journal of Haehwa Medicine
    • /
    • v.22 no.1
    • /
    • pp.37-48
    • /
    • 2013
  • This study aims to summarize and makes a reference of anti-inflammatory activities of herbal medicines. In this process, this review collated papers of anti-inflammation-focused studies using herbal medicines in Oriental medical journals since 2003. Finally 221 papers were included and the type of materials, the type and effective classification of herbal medicines, the type of cells used in the experiments and the action and mechanisms of herbal medicine were analysed. The herbal medicines having the effects of decreasing fire and tonifying and nourishment were used the most. Most herbal medicines in this study can decrease proinflammatory cytokines, NO and prostaglandin 2 (PGE 2) production, inducible nitric oxide synthase (iNOS) and cyclooxygenase-2 (COX-2) expression by regulating of nuclear factor kappa B (NF-${\kappa}B$) and/or mitogen activated protein kinases (MAPKs).

Anti-aging Effect of Phytochemical fused Peptides (피토케미칼 융합 펩타이드 신소재의 안티에이징 효능)

  • Cho, Moon-Jin;Seo, Hyo-Hyun;Lee, Yu-Ri;Moh, Ji-Hong;Moh, Sang-Hyun;Cho, Suk-Hyung;Kim, Young-Jun;Lee, Jeong-Hun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05a
    • /
    • pp.187-190
    • /
    • 2012
  • 본 연구는 피토케미칼과 펩타이드의 융합된 신소재의 항노화 효능에 관한 연구이다. 대표적인 피토케미칼인 갈릭산 및 시키믹산에 식물유래 Pentapeptide인 Exorphin을 융합시켜 만든 Galloyl Exorphin 및 Shikimoyl Exorphin은 콜라겐 합성능 및 항염증 효능 등을 보여주었다. 이러한 피토케미칼 융합 펩타이드 신소재는 피토케미칼이 가진 Stability 및 Solubility를 향상시키며, 피토케미칼 및 펩타이드 소재가 가진 각각의 효능을 유지시켰다. 이러한 결과는 피토케미칼 융합 펩타이드 소재가 항노화 소재로서 화장품 포물레이션에 널리 활용될 수 있음을 의미한다.

  • PDF