• 제목/요약/키워드: Anti-Resonance

검색결과 235건 처리시간 0.038초

Analysis on the cascade high power piezoelectric ultrasonic transducers

  • Lin, Shuyu;Xu, Jie
    • Smart Structures and Systems
    • /
    • 제21권2호
    • /
    • pp.151-161
    • /
    • 2018
  • A new type of cascade sandwiched piezoelectric ultrasonic transducer is presented and studied. The cascade transducer is composed of two traditional longitudinally sandwiched piezoelectric transducers, which are connected together in series mechanically and in parallel electrically. Based on the analytical method, the electromechanical equivalent circuit of the cascade transducer is derived and the resonance/anti-resonance frequency equations are obtained. The impedance characteristics and the vibrational modes of the transducer are analyzed. By means of numerical method, the dependency of the resonance/anti-resonance frequency and the effective electromechanical coupling coefficient on the geometrical dimensions of the cascade transducer are studied and some interesting conclusions are obtained. Two prototypes of the cascade transducers are designed and made; the resonance/anti-resonance frequency is measured. It is shown that the analytical resonance/anti-resonance frequencies are in good agreement with the experimental results. It is expected that this kind of cascade transducer can be used in large power and high intensity ultrasonic applications, such as ultrasonic liquid processing, ultrasonic metal machining and ultrasonic welding and soldering.

Anti-windup 보상기의 점프공진에 관한 연구 (Jump resonance in anti-windup compensator for systems with saturating actuators)

  • 박영진;장원욱
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.1060-1066
    • /
    • 1992
  • One of the undesirable nonlinear phenomenon called 'wind up' occours when the integrator in the controller and the saturated actuator interact. Large overshoot, slow response, instability, limit cycle and jump resonance are the characteristics of wind up phenomenon. Several 'anti-windup' compensators have been developed to prevent some of the aforementioned nonlinear characteristics such as instabilituy and limit cycle, but none has studied the effect of antiwindup compensator on the jump resonance. In this paper, we developed an analyitcal method to design the compensator to prevent not only limit cycle but also jump resonance. An illustrative example is included to show the compensator eliminates jump resonance of effectively.

  • PDF

대형석탄화력발전용 보일러 관군의 Anti-Noise Baffle 설치에 따른 음향공진 (Acoustic resonance by Inserting Anti-noise Baffle in the Tube Bank of Boiler of a Large Fossil Power Plant)

  • 방경보;김철홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.178-183
    • /
    • 2004
  • This paper presents phenomena of vibration and noise due to acoustic resonance in tube bank of a large fossil power plant. The phenomena of acoustic resonance may arise when the vortex shedding frequency coincides with the acoustic natural frequency. In this system dominant frequency of vibration and noise was 37.5Hz. The $3^{rd}$ acoustic natural frequency calculated was 37.2 Hz. When the difference of vortex shedding frequency and acoustic natural frequency is within ${\pm}20%$, acoustic resonance could occur. If system is the state of acoustic resonance, vibration and noise become large. In order to prevent acoustic resonance, anti-noise baffle should be installed in the tube bank. In the case of installing baffle, we should consider the number of baffle and the effect of acoustic mode due to baffle extension length. To do this, we did acoustic mode analysis. After installing anti-noise baffle, acoustic resonance was disappeared and vibration magnitude and noise level was reduced dramatically.

  • PDF

와인드업 방지 보상기의 점프공진 제거 특성 (Anti-Jump Resonance Characteristics of Anti-Windup Compensator for Systems with a Saturating Actuator)

  • 장원욱;노현석;박영진
    • 대한기계학회논문집
    • /
    • 제17권6호
    • /
    • pp.1342-1350
    • /
    • 1993
  • 본 논문에서는 참고문헌(12)에서 개발된 와인드업 방지 보상기를 사용하여 점프공진 현상을 제거할 수 있음을 참고문헌(16)에 제시된 방법에 기초하여 보이고 이를 위한 보상기 이득 결정 방법을 제시하려 한다.

Sensitivity Analysis of Anti-resonance Frequency for Vibration Test Control of a Fixture

  • Jeong, Weui-Bong;Yoo, Wan-Suk;Kim, Jun-Yeop
    • Journal of Mechanical Science and Technology
    • /
    • 제17권11호
    • /
    • pp.1732-1738
    • /
    • 2003
  • The test specimen in environmental vibration test is connected to the fixture through several attachment points. The forces generated by the shaker must be transmitted equally to all attachment points. The forces transmitted to attachment points, however, are different because of the flexural vibration of the fixture. The variations of the transmitted force cause the under-test, especially at anti-resonance frequencies, in vibration test control. Anti-resonance frequencies at the attachment points of the fixture must be same in order to avoid the under-test in vibration test control. The structural modification of the fixture is needed so that anti-resonance frequencies at attachment points have the same value. In this paper, the method to calculate the anti-resonance frequencies and those sensitivities is presented. This sensitivity analysis is applied to the structural modification of the fixture excited at multi-points by the shaker. The antiresonance frequencies at the attachment points of the fixture can have the same value after structural modification, and the under-test in the vibration test control can be removed. Several computer simulations show that the proposed method can remove the under-tests, which are not removed in conventional vibration test control.

하소온도가 BaTiO3 세라믹의 Kp와 공진특성에 미치는 영향 (Effects of Calcining Temperature on Planar Coupling Factor and Resonance Charcteristics of BaTiO3)

  • 정수태;조상희
    • 한국세라믹학회지
    • /
    • 제23권6호
    • /
    • pp.66-70
    • /
    • 1986
  • The calcining temperature ranging from 900$^{\circ}C$ to 1300$^{\circ}C$ affected on the planar coupling factor and resonance characteristics of BaTiO3 ceramics doped with 0.2 wt% MnO2 have been investigated. Dielectric constant planar coupling factor and anti-resonance frequency of the sample increased with the calcining temperature up to 1,200$^{\circ}C$ and decreased above that temperature but the resonance frequency decreased slightly with the increasing calcining temperature. The planar coupling factor and anti-resonance frequency increased with the sintered density and dielectric constant while the resonance frequency was almost constant. The resonance and anti-resonance frequency increased with the sample temperature.

  • PDF

조류발전용 수직축 터빈의 공진 회피 설계를 위한 프로그램 개발 (Development of Vibration Analysis Program for Anti-resonance Design of Vertical-axis Tidal Current Turbine)

  • 배재한;성혜민;조대승;김재호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.336-341
    • /
    • 2012
  • The vertical-axis tidal current turbine (VAT) consisting of blades, struts to support blades, shaft, generator and so forth requires anti-resonance design against fluid fluctuation forces generated on blades to ensure its stable operation. In this study, a free vibration analysis program based on the finite element method is developed for efficient anti-resonance design of VAT in the preliminary design stage. In the finite element modeling, the VAT structure components are regarded as beam elements. Added masses due to the fluid and structure interaction of VAT evaluated by empirical formulas are considered as lumped mass elements. In addition, input parameters required for the analysis can be automatically prepared from the principal dimensions of VAT to make anti-resonance design more convenient. The validity of applied methods is verified by the comparison of the numerical results obtained from MSC/Nastran and the developed program for two VAT models.

  • PDF

Backbone assignment and structural analysis of anti-CRISPR AcrIF7 from Pseudomonas aeruginosa prophages

  • Kim, Iktae;Suh, Jeong-Yong
    • 한국자기공명학회논문지
    • /
    • 제25권3호
    • /
    • pp.39-44
    • /
    • 2021
  • The CRISPR-Cas system provides adaptive immunity for bacteria and archaea against invading phages and foreign plasmids. In the Class 1 CRISPR-Cas system, multi-subunit Cas proteins assemble with crRNA to bind to DNA targets. To disarm the bacterial defense system, bacteriophages evolved anti-CRISPR (Acr) proteins that actively inhibit the host CRISPR-Cas function. Here we report the backbone resonance assignments of AcrIF7 protein that inhibits the type I-F CRISPR-Cas system of Pseudomonas aeruginosa using triple-resonance nuclear magnetic resonance spectroscopy. We employed various computational methods to predict the structure and binding interface of AcrIF7, and assessed the model with experimental data. AcrIF7 binds to Cas8f protein via flexible loop regions to inhibit target DNA binding, suggesting that conformational heterogeneity is important for the Cas-Acr interaction.

백래시 크기 변화 감지를 위한 주파수응답특성의 활용 (The Utilization of Frequency Response Characteristic for the Detection of Change of Backlash Magnitude)

  • 백주현
    • 한국시뮬레이션학회논문지
    • /
    • 제24권3호
    • /
    • pp.45-54
    • /
    • 2015
  • 본 논문에서는 기어감속 서보시스템의 모터입력전압 크기를 적절히 감소시키면 모터입력전압에 대한 모터각속도에서 나타나는 주파수응답특성에 미치는 백래시 영향이 매우 커지게 됨을 보여 주였다. 또한 주파수응답선도에서 나타나는 반공진 및 공진주파수 변화량을 관찰하여 기어감속 서보시스템 내 기어 백래시 변화를 감지할 수 있는 방법의 유용성을 이론적, 시뮬레이션 및 실험적으로 검증하였다. 반공진주파수 변화가 공진주파수 변화 보다 안정적으로 계측될 수 있으므로 백래시 크기 변화감지 시 반공진주파수 변화량 관찰이 좀 더 유용하며, 공진주파수는 모터입력전압을 충분히 감속시켜야 급격한 변화를 관찰할 수 있음을 보여주었다. 본 연구는 기어감속 서보시스템 내 백래시 크기 변화 감지에 대한 향후 연구에 있어서 유용하게 사용될 수 있을 것이라고 생각한다.

An Investigation of Control Parameters of Active Filters Based on Voltage Detection

  • SATO Yukihiko;KAWASE Takeshi;MACHIDA Hiraku
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.475-479
    • /
    • 2001
  • Compensation characteristics or active filters based on voltage detection are investigated. These active filters act equivalently as a passive circuit so that they may not cause practical problems such as stimulation of resonance in the distribution lines. Thus, these active filters can be used as the general-purpose active filters. On the other hand, these active filters may have a possibility of the anti-resonance associated with the line inductance of the distribution lines. In this paper, the relationship between the anti-resonance and the control parameters of the proposed active filters is clarified. Some methods to avoid the problems due to the anti-resonance are investigated. Experimental results are included to confirm the validity of the investigation presented in this paper.

  • PDF