• Title/Summary/Keyword: Anthropogenic factor

Search Result 138, Processing Time 0.021 seconds

Estimation of the Temporal and Spatial Distribution of Anthropogenic Heat in Daegu (대구지역 인공열의 시공간적 분포 추정에 관한 연구)

  • 안지숙;김해동;홍정혜
    • Journal of Environmental Science International
    • /
    • v.11 no.10
    • /
    • pp.1045-1054
    • /
    • 2002
  • Urban atmospheric conditions are usually settled as warmer, drier and dirtier than those of rural counterpart owing to reduction of green space and water space area heat retention in surfaces such as concrete and asphalt, and abundant fuel consumption. The characteristics of urban climate has become generally known as urban heat island. The purpose of this study is to investigate the temporal and spatial distribution of the heat emission from human activity, which is a main factor causing urban heat island. In this study, the anthropogenic heat fluxes emitted from vehicles and constructions are estimated by computational grid mesh which is divided by 1km $\times$ 1km. The anthropogenic heat flux by grid mesh can be applied to a numerical simulation model of the local circulation model. The constructions are classified into 9 energy-consumption types - hospital, hotel, office, department store, commercial store, school, factory, detached house and flat. The vehicles classified into 4 energy-consumption types - car, taxi, truck and bus. The seasonal mean of anthropogenic heat flux around central Daegu exceeded $50 W/m^2$ in winter. The annual mean anthropogenic heat flux exceeded $20 W/m^2$. The values are nearly equivalent to the anthropogenic heat flux in the suburbs of Tokyo, Japan.

A Study on the Characteristics of Airborne Trace Metal Elements using Diverse Statistical Approaches in the Daejeon 1st and 2nd Industrial Complex Area (다양한 통계기법을 이용한 대전 1,2 공단지역의 미량금속원소의 특성 연구)

  • 이진홍;장미숙;임종명
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.2
    • /
    • pp.95-112
    • /
    • 2002
  • A precision analysis was conducted for the quantification of trace metal levels in airborne particulates using ICP-MS. According to our study the quantitative analysis using Whatman grade 41 filters produces more precise and representative values of metal concentrations than that using EPM 2000 filters. The mean concentration of PM 10 analyzed during 1998 ~ 2000 was 82 $\mu$g/m$^3$. The concentrations of human carcinogens such as As and Cr were 8.65 and 25.87 ng/m$^3$, respectively, while those of probable human carcinogens such as Cd and Pb were 3.13 and 219.46 ng/m$^3$, respectively. Time-weighted mean concentration, calculated using surface wind speed and direction, indicated that there were differences between metals of crustal origin and metals of anthropogenic origin. The rectorial concentrations of anthropogenic metals and PM 10 were higher for north -west sector with calm or low wind speed conditions than for any other sector with high wind speed conditions. On the contrary, the rectorial concentrations of crustal metals were high with high wind speed. In addition, the sectorial concentrations of crustal metals were more affected by south-west wind directions, which were compared with those of anthropogenic metals. The enrichment factor (EF) values of many anthropogenic metals were higher than 50, while those of crustal metals were lower than 3, respectively. The concentrations of Cr and Ni in Daejeon industrial complex area were 11 times higher than those in the background site of Kuopio in Finland, while that of Pb in the complex area was 22 times higher, respectively.

A Study on Ion Distribution and Behavior of Acidrain in Mokpo and Yeochon Area (목포, 여천지역 강수의 무기이온 성분농도와 거동에 관한 연구)

  • 오길영;양수인;이완진
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.4
    • /
    • pp.385-392
    • /
    • 1999
  • This study was carried out to investigate the constituents of inorganic ions of precipitation in Mokpo and Yeochon area from Jan. 1996 to Dec. 1997. The volume-weighted mean pH of precipitation was 5.7(4.8~7.8) at Mokpo, and 5.6(5.1~7.4) at Yeochon area, respectively. The non-seasalt(nss) anion concentrations were found in order of $nss-SO^{2-}_4>NO^-_3>nss-Cl^-$ at two areas. The portion of $nss-SO^{2-}_4;and;NO^-_3$ was 71~84% out of anions. The the non-seasalt cation concentrations were found in order of $NH^+_4>nss-Ca^{2-}>nss-Mg^{2+}>nss-K^-$ at two areas. The portion of $NH^+_4;and; nss-Ca^{2+}$ was 85~92% out cations. Compared regionally the year concentraton of $nss-SO^{2-}_4$, the result of Yeochon was 3 times higher than that of Mokpo in 1996, while the results of two regions were almost similar in 1997. The reason was that Yeochon was restricted area of the use of 0.5% sulfur B-C oil, controlled air pollution emission area, controlled semitotal amounts of air pollution emission area and partial operating of factories in 1997. There were no ions having high correlation with $H^+,;but;nss-SO^{2-}_4,;NO^-_3,;NH^+_4;and;nss-Ca^{2+}$ showed high correlation coefficient each other. It seems that these ions have little correlation with $H^+$ because they are washed out on binding state. Factor analysis showed that the first factor was complicated factor containing anthropogenic and soil resource, the second factor was sea-salt resource and the third factor was independent behavior of hydrogen at Mokpo. While, the first factor was complicated factor containing anthropogenic and sea-salt resource, the second factor was $Ca(NO_3)_2$ salt and the third factor was $NH^+_4;and;SO^{2-}_4$ synergied by resource and combination at Yeochon.

  • PDF

Geochemical characteristics of spring, ground and thermal waters in Mt. Geumjeong-Mt. Baekyang area, Pusan (부산 금정산-백양산 일대 용천수, 지하수 및 지열수의 지화학적 특성)

  • Hamn, Se-Yeong;Cho, Myong-Hee;Hwang, Jin-Yeon;Kim, Jin-Sup;Sung, Ig-Hwang;Lee, Byeong-Dae
    • Journal of Environmental Science International
    • /
    • v.9 no.3
    • /
    • pp.229-239
    • /
    • 2000
  • Spring, ground and thermal waters in the vicinity of Mt. Geumjeong and Mt. Baekyang area have been sampled and analyzed for major and minor elements. According to the Piper diagram, spring water belongs to $Ca-HCO_3$ and $Na-HCO_3$ types, groundwater to $Ca-HCO_3$ type, and thermal water to Na-Cl type. Based on the phase stability diagrams of $[Ca^{2+}]/{[H^+]}^2, [Mg^{2+}]/{[H^+]}^2, [K^+]/[H^+]$, and $[Na^+]/[H^+] vs. [H_4SiO_4]$, spring water, groundwater and thermal water are mostly in equilibrium with kaolinite. The result of factor analysis shows three factors (factor 1, 2 and factor 3) for the spring water, the groundwater and the thermal water which are represented by the influence of the dissolution of feldspar, calcite, anthropogenic sources (domestic and industrial wastes) and salt water.

  • PDF

Elemental Composition of PM2.5 Particulate with a 3-Stage DRUM Sampler during Spring and Summer Seasons in Urban Area of Gwangju, Korea (3-Stage DRUM 샘플러를 이용한 광주 도심지역의 봄철과 여름철 PM2.5 원소적 조성 비교)

  • Ryu S.Y.;Kim Y.J.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.6
    • /
    • pp.699-708
    • /
    • 2005
  • To characterize the elemental composition of fine particles in urban area, $PM_{2.5}$ was collected by a 3-stage DRUM impactor at Gwangju during spring and summer. Time and size resolved concentrations for 19 trace elements were obtained by synchrotron X-Ray fluorescence analysis. Trace elements in summer were distributed in smaller size range compared to those in spring. Almost trace element concentrations in fine particles were highly increased during the Asian dust. In spring, soil elements such as Si, K, Ca, Ti and Fe had low enrichment factors indicating the dominant influence of soil dust. However, all elements had high enrichment factors in summer implying that these elements could be emitted from the anthropogenic sources. Factor analysis was conducted with the elemental composition data in order to identify anthropogenic sources of aerosols in urban area during spring and summer. Fine particles in spring have several sources such as soil dust originating from China continental region, coal and oil combustion, biomass burning, sea salt, ferrous and nonferrous metal sources. On the other hand, fine particles in summer were influenced by road dust, gasoline vehicle as well as coal and oil combustion, sea salt, ferrous and nonferrous metal sources.

Monthly Variation of n-alkanes concentration in PM2.5 of the Anmyeon Island (안면도 대기 중 PM2.5 내 n-alkanes의 월별 농도 분포 특성)

  • Kim, Ki Ae;Lee, Jong Sik;Kim, Eun Sil;Jung, Chang Hoon;Kim, Yong Pyo;Lee, Ji Yi
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.1
    • /
    • pp.166-176
    • /
    • 2018
  • The n-alkanes which are stable compounds in the atmosphere are emitted by anthropogenic sources and biological sources. The goal of this study is to understand characteristics of n-alkane distributions in $PM_{2.5}$ of the Anmyeon Island which is one of background site in Korea. The concentration of n-alkanes in $PM_{2.5}$ was measured at Anmyeon Island for one year from June 2015 to May 2016. The average concentration of total n-alkanes (${\sum}$ n-alkanes) from C20 to C34 was $14.02{\pm}10.26ng\;m^{-3}$ and ranged from 1.77 to $47.65ng\;m^{-3}$. Various diagnostic parameters were used to identify the source. As a result, it is considered that Anmyeon Island had a large influence of biological sources during non-heating period, while the influence of anthropogenic emission during the heating period was significant. Principle Component Analysis (PCA) was performed and yielded three components that accounted for 93.6% of the total variance in n-alkanes. Factor 1, which accounted for 42.3% of the total variance, indicated anthropogenic source including fossil fuel and biomass combustion, while, Factor 3 was interpreted as the biological sources such as plant wax.

Geochemical Study of Coastal Sediments around the Samcheonpo Coal-fired Power Plant (삼천포화력발전소 주변해역 퇴적물의 지구화학적 연구)

  • Lee, Doo-Ho;Lim, Ju-Hwan;Jeong, Yeon-Tae;Jeong, Nyeon-Ho;Kang, Jeong-Won
    • Journal of Environmental Impact Assessment
    • /
    • v.10 no.2
    • /
    • pp.85-98
    • /
    • 2001
  • This study was conducted to investigate the geochemical factors governing the distribution of heavy metals(Co, Cr, Cu, Fe, Mn, Ni, Pb, and Zn) in the marine surface sediment samples collected from the Samcheonpo coal-fired power plant. Variations of absolute metal concentrations were related to those in textural and/or carbonate and organic matter content. Most elements, except for Pb, showed generally lower contents compared with the average shale concentration, and the effect of anthropogenic input appeared to be minimal in the sediments. Computations of LF%(labile fraction) and EF(enrichment factor) based on all trace metal data indicated the presence of mineralogical control for Co, Cr, Cu, Ni, and Zn, and anthropogenic contamination for Pb, which needs to be considered in the design of long term monitoring programmes.

  • PDF

A Study on Chemical Characterization of Precipitation in the Central Part of Korea from 1994 to 1997 (1994~1997년 중부지방에 내린 강수의 화학적 특성에 관한 연구)

  • 조하만;최재천
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.6
    • /
    • pp.589-598
    • /
    • 1998
  • This study was conducted to investigate the chemical characteristics of Precipitation at Seoul, Yangpyong, Hongchon and Inje in the central part of Korean peninsula during the period from March 1994 to November 1997. The precipitation samples were collected by automatic wet-only sampler. The samples were analyzed for major anions (SO42-, NO3-, Cl-, F-) and cations(NH4+, Ca2+, Mg+, Na+, K+), in addition to acidity and electrical conductivity. The analytical instrument for water soluble ionic components was ion chromatography. The volume - weighted mean PH were 4.73, 4.87, 4.89 and 4.81 at Seoul, Yangpyong, Hongchon and Inje, respectively. The sums of cation concentrations was slightly greater than the sums of anion concentrations. Also, the highest ion component was SO42- in anions and NH4+ in cations. The mean equivalent ratios of SO42- to NO3- were found by 2.96, 2.71, 2.43 and 2.25 at Seoul, Yangpyong, Hongchon and Inje, respectively. The factor analysis was conducted in order to make the large and diverse data set as manageable levels and to qualitatively examine the relationship between the variables. It showed that major sources of pollutants in precipitation were from the anthropogenic in Seoul, the natural in Hongchon, and the anthropogenic and natural in Yangpyong and Inje.

  • PDF

Pollution Level of Heavy Metals of Asian Dust in Daejeon Area, 2008 (2008년 대전지역에서 발생한 황사의 중금속 오염도)

  • Lee, Pyeong-Koo;Bae, Beob-Geun
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.1
    • /
    • pp.8-25
    • /
    • 2014
  • The aims of this study were to determine concentrations of selected metals in Asian and non-Asian dust collected in Daejeon, Korea between February 2008 and December 2008 and to estimate the pollution level. The geochemical analyses of Asian dust (AD) and Non Asian dust (NAD) show that the mean concentrations of As, Cd, Cu, Pb, Zn, Zr, Sb, Mo and S reached levels up to 16, 209, 31, 43, 81, 28, 31, 122 and 302 times higher, respectively, than those in uncontaminated Chinese desert soils. These results indicate that both AD and NAD serve as an atmospheric repository for trace and heavymetal accumulation. The the enrichment factor (EF) and pollution index (PI) show that AD and NAD were severely contaminated by S, Mo, Zr, Cd, Pb, Zn, Sb, Cu, and As. All indices for these metals showed either strong or notably high level of pollution relative to Chinese desert soil, principally due to the severe atmospheric pollution derived from anthropogenic activities in heavily industrial Chinese cities. Therefore, Mo, Cd, Zr, As, Cu, Sb, Pb, and Zn are the ones most strongly affected by anthropogenic inputs such as airborne pollutants.

Study on the Chemical Characteristics of $PM_{10}$ at Background Area in Korean Peninsula (한반도 서해안 배경지역 미세입자의 화학적 특성 연구)

  • Bang So-Young;Baek Kwang-Wook;Chung Jin-Do;Nam Jae-Cheol
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.5 s.81
    • /
    • pp.455-468
    • /
    • 2004
  • The purpose of this paper is to understand the time series and origin of a chemical component and to compare the difference during yellow sand episodes for analysis $PM_{10}$ chemical components in the region of west in Korean Peninsula, 1999-2001. An annual mean concentration of $PM_{10}$ is $29.1\;{\mu}g/m^3$. A monthly mean and standard deviation of $PM_{10}$ concentration are very high in spring but there is no remarkably seasonal variation. Also, water soluble ionic component of $PM_{10}$ be influenced by double more total anion than total cation, be included $NO_{3}^-\;and\;SO_{4}^{2-}$ for the source of acidity and $NH_{4}^+$ to neutralize. Tracer metals of $PM_{10}$ slowly increases caused by emitted for soil and ocean (Fe, Al, Ca, Mg, Na) and Zn, Pb, Cu, Mn for anthropogenic source. According to method of enrichment factor (E.F) and statistics, assuming that the origin of metal component in $PM_{10}$ most of element in the Earth's crust e.g. Mg, Ca, Fe originates soil and Cu, Zn, Cd, Pb derives from anthropogenic sources. The ionic component for $Na^{+}\;Cl^-,\;Mg^{2+}\;and\;Ca^{2+}$ and Mg, Al, Ca, Fe originated by soil component largely increase during yellow sand period and then tracer metal component as Pb, Cd, Zn decrease. According to factor analysis, the first group is ionic component ($Na^+,\;Mg^{2+},\;Ca^{2+}$) and metal component (Na, Fe, Mn and Ni) be influenced by soil. The second group, Mg, Cr also be influenced by soil particle.