• Title/Summary/Keyword: Anterior plate

Search Result 254, Processing Time 0.028 seconds

Displacement and stress distribution of the maxillofacial complex during maxillary protraction using palatal plates: A three-dimensional finite element analysis

  • Eom, Jusuk;Bayome, Mohamed;Park, Jae Hyun;Lim, Hee Jin;Kook, Yoon-Ah;Han, Seong Ho
    • The korean journal of orthodontics
    • /
    • v.48 no.5
    • /
    • pp.304-315
    • /
    • 2018
  • Objective: The purpose of this study was to analyze initial displacement and stress distribution of the maxillofacial complex during dentoskeletal maxillary protraction with various appliance designs placed on the palatal region by using three-dimensional finite element analysis. Methods: Six models of maxillary protraction were developed: conventional facemask (Type A), facemask with dentoskeletal hybrid anchorage (Type B), facemask with a palatal plate (Type C), intraoral traction using a Class III palatal plate (Type D), facemask with a palatal plate combined with rapid maxillary expansion (RME; Type E), and Class III palatal plate intraoral traction with RME (Type F). In Types A, B, C, and D, maxillary protraction alone was performed, whereas in Types E and F, transverse expansion was performed simultaneously with maxillary protraction. Results: Type C displayed the greatest amount of anterior dentoskeletal displacement in the sagittal plane. Types A and B resulted in similar amounts of anterior displacement of all the maxillofacial landmarks. Type D showed little movement, but Type E with expansion and the palatal plate displayed a larger range of movement of the maxillofacial landmarks in all directions. Conclusions: The palatal plate served as an effective skeletal anchor for use with the facemask in maxillary protraction. In contrast, the intraoral use of Class III palatal plates showed minimal skeletal and dental effects in maxillary protraction. In addition, palatal expansion with the protraction force showed minimal effect on the forward movement of the maxillary complex.

Descriptions on the Plate Patterns of Genus Protoperidinium for Plankton Monitoring Network (플랑크톤 모니터링 네트워크를 위한 Protoperidinium속의 패각 유형 기재)

  • Yeo, Hwan-Goo;Shin, Eun-Young
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.845-847
    • /
    • 2009
  • In thecate dinoflagellates, the thecal plate pattern has been considered to be important criteria in their classifications. Due to this fact the shape of the theca and the arrangement of the theca were studied. In the pictures, the distinctions between the plates in the cells were so vague that I drew a diagram to illustrate the plate pattern. To identify the genus Protoperidinium, the shape of the first apical plate and the second anterior intercalary plate were used. Depending the shape of first apical plate, will be designated as meta(4), meta(5), para(4), para(5) or para(6). The shape of first apical plate is considered an important factor. From this point of view, the genus Protoperidinium as a group of planktonic protist in the coastal environment was classified.

  • PDF

Anterior Cervical Instrumentation Using Intradiscal Cage with Integrated Plate

  • Ahn, Kyoung-Rok;Ryu, Kyeong-Sik;Chang, In-Bok;Cho, Byung-Moon;Park, Se-Hyuck;Oh, Sae-Moon
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.4
    • /
    • pp.260-264
    • /
    • 2006
  • Objective : The retrospective study is undertaken to report clinical results of anterior cervical interbody fusion with an intradiscal cage with an integrated plate [PCB cervical plating system]. Methods : 38 patients underwent anterior cervical interbody fusion with PCB cervical plating system and followed $6{\sim}24\;months$. The authors investigated overall surgical results; clinical outcome, fusion rate, change of interspace height & lordotic angle, and complications. Results : No complication was observed during the operation. Clinical improvement was identified in 34 cases [89.5%]. Bone fusion observed in 44 out of 49 sites [90.7%]. After operation, the interspace height increased from $5.4{\pm}1.3mm$ to $7.8{\pm}1.5mm$ and maintained $7.4{\pm}1.1mm$ and, interspace angle went up from $4.2{\pm}0.7^{\circ}$ to $4.8{\pm}1.1^{\circ}$ and maintained $4.6{\pm}$0.9^{\circ}. The loosening of screw was observed in 6 cases, one of which had reoperation because of the expulsion of the device accompanied. Conclusion : PCB cervical plating system could restore interbody height and lordosis in anterior cervical interbody fusion. But, if the insertion of the spacer is not precise, the frequencies of hardware failure are relatively high. It is considered necessary for the operator to be careful in the procedure.

New Surgical Technique for Harvesting Proximal Fibular Epiphysis in Free Vascularized Epiphyseal Transplantation (혈관부착 근위비골성장판 이식시 공여부 수술의 새로운 술식)

  • Chung, Duke-Whan
    • Archives of Reconstructive Microsurgery
    • /
    • v.5 no.1
    • /
    • pp.106-111
    • /
    • 1996
  • Purpose : Propose a surgical technique in donor harvesting method in free vascularized proximal fibular epiphysis. Methodology : Concerned about growth potentials of the transplanted epiphysis in our long term results of the epiphyseal transplanted 13 cases more than 4 years follow-up, anterior tibial artery which contains anterior tibial recurrent artery is most reliable vessel to proximal fibular epiphysis which is the best donor of the free vascularized epiphyseal transplantation. In vascular anatomical aspect proximal fibular epiphysis norished by latearl inferior genicular artery from popliteal, posterior tibial recurrent artery and anterior tibial recurrent artery from anterior tibial artery and peroneal artery through metaphysis. The lateral inferior genicular artery is very small and difficult to isolate, peroneal artery from metaphysis through epiphyseal plate can not give enough blood supply to epiphysis itself. The anterior tibial artery which include anterior tibial recurrent and posterior tibial recurrent artery is the best choice in this procedure. But anterior tibial recurrent artery merge from within one inch from bifucating point of the anterior and posterior tibial arteries from popliteal artery. So it is very difficult to get enough vascular pedicle length to anastomose in recipient vessel without vein graft even harvested from bifucating point from popliteal artery. Authors took recipient artery from distal direction of anterior tibial artery after ligation of the proximal popliteal side vessel, which can get unlimited pedicle length and safer dissection of the harvesting proximal fibular epiphysis. Results : This harvesting procedure can performed supine position, direct anterolateral approach to proximal tibiofibular joint. Dissect and isolate the biceps muscle insertion from fibular head, micro-dissection is needed to identify the anterior tibial recurrent arteries to proximal epiphysis, soft tissue release down to distal and deeper plane to find main anterior tibial artery which overlying on interosseous membrane. Special care is needed to protect peroneal nerve damage which across the surgical field. Conclusions : Proximal fibular epiphyseal transplantation with distally directed anterior tibial artery harvesting technique is effective and easier dissect and versatile application with much longer arterial pedicle.

  • PDF

Ulnar Nerve Injury Caused by the Incomplete Insertion of a Screw Head after Internal Fixation with Dual Locking Plates in AO/OTA Type C2 Distal Humerus Fractures

  • Shin, Jae-Hyuk;Kwon, Whan-Jin;Hyun, Yoon-Suk
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.236-239
    • /
    • 2017
  • After dual plating with a locking compression plate for comminuted intraarticular fractures of the distal humerus, the incidence of ulnar nerve injury after surgery has been reported to be up to 38%. This can be reduced by an anterior transposition of the ulnar nerve but some surgeons believe that extensive handling of the nerve with transposition can increase the risk of an ulnar nerve dysfunction. This paper reports ulnar nerve injuries caused by the incomplete insertion of a screw head in dual plating without an anterior ulnar nerve transposition for AO/OTA type C2 distal humerus fractures. When an anatomical locking plate is applied to a distal humeral fracture, locking screws around the ulnar nerve should be inserted fully without protrusion of the screw because an incompletely inserted screw can cause irritation or injury to the ulnar nerve because the screw head in the locking system usually has a slightly sharp edge because screw head has threads. If the change in insertion angle and resulting protruded head of the screw are unavoidable for firm fixation of fracture, the anterior transposition of the ulnar nerve is recommended over a soft tissue shield.

Analysis of Sternal Fixation Results According to Plate Type in Sternal Fracture

  • Byun, Chun Sung;Park, Il Hwan;Hwang, Wan Jin;Lee, Yeiwon;Cho, Hyun Min
    • Journal of Chest Surgery
    • /
    • v.49 no.5
    • /
    • pp.361-365
    • /
    • 2016
  • Background: Sternal fractures are relatively rare, and caused mainly by blunt anterior chest wall trauma. In most cases, sternal fractures are treated conservatively. However, if the patient exhibits problematic symptoms such as intractable chest wall pain or bony crepitus due to sternal instability, surgical correction is indicated. But no consensus exists regarding the most appropriate surgical method. We analyzed the results of surgical fixation in cases of sternal fracture in order to identify which surgical method led to the best outcomes. Methods: We retrospectively reviewed the medical records of patients with sternal fractures from December 2008 to December 2011, and found 19 patients who underwent open reduction and internal fixation of the sternum with a longitudinal plate (L-group) or a T-shaped plate (T-group). We investigated patients' characteristics, clinical details regarding each case of chest trauma, the presence of other associated injuries, the type of open reduction and fixation, whether a combined operation was performed, and postoperative complications. Results: Of the 19 patients, 10 patients (52.6%) were male, and their average age was 56.8 years (range, 32 to 82 years). Seven patients (36.8%) had isolated sternal fractures, while 12 (63.2%) had other associated injuries. Seven patients (36.8%) were in the L-group and 12 patients (63.2%) were in the T-group. Three patients in the L-group (42.9%) showed a loosening of the fixation. In all patients in the T-group, the fracture exhibited stable alignment. Conclusion: Open reduction and internal fixation with a T-shaped plate in sternal fractures is a safer and more efficient treatment method than treatment with a longitudinal plate, especially in patients with a severely displaced sternum or anterior flail chest, than a longitudinal plate.

Effect of Target Height on Ground reaction force factors during Taekwondo and Hapkido Dollyuchagi Motion (태권도와 합기도의 돌려차기시 타격 높이가 지면반력에 미치는 영향)

  • Yang, Chang-Soo
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.1
    • /
    • pp.193-204
    • /
    • 2002
  • The purpose of this study was to investigate the effect of martial art type and target height on the ground reaction force factors during Dollyuchagi motion. Data were collected using force plate. Five Taekwondo players and five Hapkido players were tested during Dollyuchagi motion to three different target heights(0.8, 1.2, 1.6 m). After analysis of kinetics using force plate data, maximum vertical ground reaction force was 1.62~2.44 BW, and impulse was $0.66\sim1.01 BW{\cdot}s$. Even though there was no difference for maximum ground reaction forces and impulse between Hapkido and Taekwondo, as target height was higher, impulse increased. Anterior-posterior and vertical ground reaction forces at kicking foot take-off were greater with target height, although there was no difference for medio-lateral force with target height. At impact there was significant difference for anterior-posterior ground reaction force between Hapkido and Taekwondo players. Taekwondo players' force (range, -0.23~-0.26 BW) was greater than Hapkido players's force (range, -0.08~-0.14 BW).

A New Species of the Genus Agauopsis (Acari: Halacaridae) from Jeju Island, Korea

  • Shin, Jong Hak;Chang, Cheon Young
    • Animal Systematics, Evolution and Diversity
    • /
    • v.35 no.2
    • /
    • pp.49-56
    • /
    • 2019
  • A new marine halacarid species of the genus Agauopsis Viets, 1927 (Acari: Halacaridae) is recorded from Jeju Island, Korea. Agauopsis tetrasetosa n. sp. belongs to the microrhyncha group in sharing one ventral and three ventromedial spines on tibia of leg I, of which two ventromedial ones are adjacent to each other, with its 20 congeneric members. Agauopsis tetrasetosa n. sp. is most similar to A. miliaris Bartsch, 2005 and A. similis Bartsch, 1979 in sharing the similar chaetotaxy of legs I-IV, positions of the second and fourth dorsal setae, and non 'H'- or 'M'-shaped costae on anterior dorsal plate. However, the new species is distinguished from them by four pairs of perigenital setae in female, the relatively anterior location of gland pores on posterior dorsal plate, and three ventral spines on the tibia of leg II. We describe the new species herein, with detailed illustrations under a differential interference contrast microscope. We also make some brief comments on the affinities between the congeneric species of the microrhyncha group and the new species, based on a tabular key to species of the group.

A STUDY OF THE FOCAL TROUGH IN ORTHOPANTOMOGRAPH (Orthophantomograph에 있어서 상층면적에 관한 연구)

  • Choi Chong-Ho;Khim Jhai-Dhuck
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.1
    • /
    • pp.137-143
    • /
    • 1991
  • In the study of the focal trough of panoramic radiograph using Panoura Eight-S (the Yoshida company), a series of 63 X-ray films were taken with the 8-19 metal pins placed in the holes of the plastic model plate and evaluated by 4 observers. The author analized the focal trough defined by the sharpness criteria and calculated dimension of focal trough in the horizontal plane. The results were as follows; 1. Focal trough was not continued in the anterior region within a very high degree of sharpness. 2. With optional sharpness, the width of anterior and posterior focal trough was approximately l3㎜ and 60㎜ respectively. 3. The focal trough was narrow in the anterior region and was flared laterally with symmetry in posterior region. 4. Sharp image began to show at the position of 18㎜ posteriorly from the most anterior position of chin rest.

  • PDF

A Prospective Study with Cage-Only or Cage-with-Plate Fixation in Anterior Cervical Discectomy and Interbody Fusion of One and Two Levels

  • Kim, Sam Yeol;Yoon, Seung Hwan;Kim, Dokeun;Oh, Chang Hyun;Oh, Seyang
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.6
    • /
    • pp.691-700
    • /
    • 2017
  • Objective : The authors prospectively analyzed the effect of one-level or two-level anterior cervical discectomy and fusion (ACDF), comparing stand-alone cages and cage-with-plate fixation constructs with respect to clinical outcomes and radiologic changes. Methods : A total of 84 patients who underwent one-level (n=52) or two-level ACDF (n=32) for cervical disc disease and who completed 2 years of follow-up were included in this study. The patients were divided by cervical level and grouped into ACDF-Cage-only and ACDF-Cage-with-plate groups. The following parameters were assessed using radiographs : subsidence, C2-C7 lordosis angle, fusion segment angle, adjacent disc space narrowing, and fusion status. Clinical outcomes were assessed using the neck disability index (NDI) and visual analog scale scores for arm pain. Results : In the comparison of one-level ACDF-cage-only and ACDF-cage-with-plate groups, the NDI score was better in the cage-only group at the 3-, 12-, and 24-month follow-ups : however, no significant difference in clinical outcomes was observed. In the comparison of two-level ACDF-cage-only and ACDF-cage-with-plate groups, no difference in any clinical outcome was observed between the two groups. At the 24-month follow-up, subsidence was observed in 45.8% of patients in the one-level cage-only group and 32.1% of patients in the one-level cage-with-plate fixation group. There was no statistically significant difference in the incidence rate between the two groups (p=0.312). Subsidence in the two-level cage-only group (66.6%) was significantly more frequent than in the two-level cage-with-plate fixation group (30%; p=0.049). The fusion rate for patients in the one-level cage-only group was not significantly different from that in the one-level cage-with-plate fixation group (cage-only, 87.5%; cage-with-plate fixation, 92.9%; p=0.425) ; fusion rate in the two-level patients were also similar between groups (cage-only, 83.3%; cage-with-plate fixation, 95%; p=0.31). Conclusion : Our clinical results showed that for single-level cases, plate fixation had no additional benefit versus cage-only; for two-level ACDF cases, the fusion rate and clinical outcomes were similar, although the cage-with-plate fixation group had a lower incidence of cage subsidence than did the cage-only group. We conclude that physicians should be aware of this possible disadvantage associated with using cervical plates in one-level ACDF. However, in two-level ACDF, subsidence is more likely to occur without plate fixation, and thus the addition of plate fixation should be considered.