• Title/Summary/Keyword: Anterior plate

Search Result 254, Processing Time 0.034 seconds

Surgical Reconstruction Using a Flanged Mesh Cage without Plating for Cervical Spondylotic Myelopathy and a Symptomatic Ossified Posterior Longitudinal Ligament

  • Kang, Jung Hoon;Im, Soo-Bin;Yang, Sang-Mi;Chung, Moonyoung;Jeong, Je Hoon;Kim, Bum-Tae;Hwang, Sun-Chul;Shin, Dong-Seong;Park, Jong-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.6
    • /
    • pp.671-680
    • /
    • 2019
  • Objective : We introduce innovative method of cervical column reconstruction and performed the reconstruction with a flanged titanium mesh cage (TMC) instead of a plate after anterior corpectomy for cervical spondylotic myelopathy (CSM) and an ossified posterior longitudinal ligament (OPLL). Methods : Fifty patients with CSM or OPLL who underwent anterior cervical reconstruction with a flanged TMC were investigated retrospectively. Odom's criteria were used to assess the clinical outcomes. The radiographic evaluation included TMC subsidence, fusion status, and interbody height. Thirty-eight patients underwent single-level and 12 patients underwent two-level corpectomy with a mean follow-up period of 16.8 months. Results : In all, 19 patients (38%) had excellent outcomes and 25 patients (50%) had good outcomes. Two patients (4%) in whom C5 palsy occurred were categorized as poor. The fusion rate at the last follow-up was 98%, and the severe subsidence rate was 34%. No differences in subsidence were observed among Odom's criteria or between the single-level and two-level corpectomy groups. Conclusion : The satisfactory outcomes in this study indicate that the flanged TMC is an effective graft for cervical reconstruction.

Intermediate-Term Clinical Outcomes after Autologous Osteochondral Transplantation for Lateral Osteochondral Lesions of the Talus (외측 거골 골연골 병변에 대한 자가 골연골 이식술 후의 중기 추시 임상결과)

  • Sung-Hoo Kim;Byung-Ki Cho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.27 no.4
    • /
    • pp.137-143
    • /
    • 2023
  • Purpose: Autologous osteochondral transplantation (AOT) is indicated for patients with a large osteochondral lesion of the talus (OLT), accompanying subchondral cyst, and the failure of bone marrow stimulation (BMS) procedures. Despite the many reports on the clinical results of surgical treatment for medial osteochondral lesions, those of lateral lesions are rare. This paper reports the intermediate-term clinical outcomes after AOT for lateral OLTs. Materials and Methods: Twenty-one patients with lateral OLTs were followed up for at least three years after AOT. The clinical evaluations comprised the Foot and Ankle Outcome Score (FAOS) and Foot and Ankle Ability Measure (FAAM). The radiographic assessment included the irregularity of the articular surface (subchondral plate), the progression of degenerative arthritis, and the changes in talar tilt angle and anterior talar translation. Results: The mean FAOS and FAAM scores improved significantly from 42.1 to 89.5 and 39.5 to 90.6 points, respectively, at the final follow-up (p<0.001). The radiological evaluation revealed two cases (9.5%) of articular step-off ≥2 mm and 1 case (4.8%) of progressive arthritis. The mean talar tilt angle and anterior talar translation improved significantly. As postoperative complications, there was one case of a local wound problem, one case of superficial peroneal nerve injury, and one case of donor site morbidity. At a mean follow-up of 62.3 months, no patient showed a recurrence of instability or required reoperation for OLT. Conclusion: AOT for the lateral OLTs demonstrated satisfactory intermediate-term clinical outcomes, including daily and sports activity abilities. Most OLT could be accessed through lateral ligament division and capsulotomy, and the incidence of iatrogenic complications, such as recurrent sprains or chronic instability, was minimal. AOT appears to be an effective and relatively safe treatment for patients with large lateral osteochondral lesions unresponsive to conservative therapy, with subchondral cysts, or with failed primary BMS.

Morphometric analysis of maxillary alveolar regions for immediate implantation

  • Park, Man-Soo;Park, Young-Bum;Choi, Hyunmin;Moon, Hong-Seok;Chung, Moon-Kyu;Cha, In-Ho;Kim, Hee-Jin;Han, Dong-Hoo
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.494-501
    • /
    • 2013
  • PURPOSE. The purpose of this study was to provide an actual guideline in determining the shape, diameter, and position of the implant in immediate implantation by the measurement of the thickness of facial and palatal plate, the thickness of cortical bone on the facial and palatal plate, the diameter of the root, and the distance between the roots in the cadavers. MATERIALS AND METHODS. The horizontal sections of 20 maxillae were measured and analyzed to obtain the average values. Resin blocks were produced and cut serially at 1 mm intervals from the cervical line to the root apex. Images of each section were obtained and the following measurements were performed: The thickness of the facial and palatal residual bone at each root surface, the thickness of the facial and palatal cortical bone at the interdental region, the diameter of all roots of each section on the faciopalatal and mesiodistal diameter, and the interroot distance. Three specimens with measurements close to the average values were chosen and 3-dimensional images were reconstructed. RESULTS. The thickness of the facial and palatal cortical bone at the interdental region in the maxilla, the buccal cortical bone was thicker in the posterior region compared to the anterior region. The interroot distance of the alveolar bone thickness between the roots increased from anterior to posterior region and from coronal to apical in the maxilla. CONCLUSION. In this study, the limited results of the morphometric analysis of the alveolar ridge using the sections of maxilla in the cadavers may offer the useful information when planning and selecting optimal implant for immediate implantation in the maxilla.

The Effect of the Insole Height on Lower Limb Joint Angle and Muscle Activity at Landing when the Maximal Ground Reaction Force of Male in Their 20s (착지 동작 시 깔창 높이가 20대 남성의 하지 관절 각도와 근활성도에 미치는 영향)

  • Yoo, Kyung-Tae
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.12
    • /
    • pp.132-139
    • /
    • 2020
  • The purpose of this study is to analyze the effect of the height and insole height upon landing on the lower limb joint angle and muscle activity during maximum ground repulsion in young men. For a male in their twenties, a landing motion was performed with a force plate on a 40cm-high platform by wearing one of 0, 3, 5cm polyurethane insoles per week for a total of 3 weeks. During the landing motion, the joint angle of the lower extremities and the muscle activity of the rectus femoris, biceps femoris, anterior tibialis and calf muscles were measured during the maximum ground repulsion. In order to compare the changes in the joint angle and muscle activity of the lower limbs according to the height of the insole, a one-way ANOVA with repetitive factors was performed. As a result of the analysis of the lower limb joint angle, the higher the height of the insole affected the angle of the left ankle joint. As a result of the muscle activity analysis, the higher the height of the insole affected the right anterior tibialis muscle and biceps femoris. It is thought that it is possible to protect the body when landing through sufficient muscle strength increase of the lower limb muscles. As the angle of the affected muscle and lower limb joint may be different depending on the type of insole, it is considered necessary to study it.

Load Sharing Mechanism Across Graft-Bone Interface in Static Cervical Locking Plate Fixation

  • Han, In-Ho;Kuh, Sung-Uk;Chin, Dong-Kyu;Jin, Byung-Ho;Cho, Yang-Eun;Kim, Keun-Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.4
    • /
    • pp.213-218
    • /
    • 2009
  • Objective : This study is a retrospective clinical study over more than 4 years of follow up to understand the mechanism of load sharing across the graft-bone interface in the static locking plate (SLP) fixation compared with non-locking plate (NLP). Methods : Orion locking plates and Top non-locking plates were used for SLP fixation in 29 patients and NLP fixation in 24 patients, respectively. Successful interbody fusion was estimated by dynamic X-ray films. The checking parameters were as follows : screw angle (SA) between upper and lower screw, anterior and posterior height of fusion segment between upper and lower endplate (AH & PH), and upper and lower distance from vertebral endplate to the end of plate (UD & LD). Each follow-up value of AH and PH were compared to initial values. Contributions of upper and lower collapse to whole segment collapse were estimated. Results : Successful intervertebral bone fusion rate was 100% in the SLP group and 92% in the NLP group. The follow-up mean value of SA in SLP group was not significantly changed compared with initial value, but follow-up mean value of SA in NLP group decreased more than those in SLP group (p=0.0067). Statistical analysis did not show a significant difference in the change in AH and PH between SLP and NLP groups (p>0.05). Follow-up AH of NLP group showed more collapse than PH of same group (p=0.04). The upper portion of the vertebral body collapsed more than the lower portion in the SLP fixation (p=0.00058). Conclusion : The fused segments with SLP had successful bone fusion without change in initial screw angle, which was not observed in NLP fixation. It suggests that there was enough load sharing across bone-graft interface in SLP fixation.

Balanced Tucking of the Levator Muscle and Müller's Muscle in Blepharoptosis (거근건막 전진을 병용한 Müller Turking에 의한 안검하수의 교정)

  • Park, Jang Woo;Shin, Ho Sung;Park, Eun Soo;Kim, Yong Bae
    • Archives of Plastic Surgery
    • /
    • v.33 no.2
    • /
    • pp.149-154
    • /
    • 2006
  • The levator and $M{\ddot{u}}ller^{\prime}s$ muscle balanced tucking was performed to correction myogenic or aponeurotic blepharoptosis. Through the blepharoplasty incision, the upper half of tarsal plate was exposed and the orbital was opened to show the levator aponeurosis. the $M{\ddot{u}}ller^{\prime}s$ muscle dissected from the upper border of the tarsal plate and from the posteriorly located conjunctiva with sharp scissors. $M{\ddot{u}}ller^{\prime}s$ muscle was advanced about 3 mm to 8 mm on anterior surface of the tarsal plate and fixed approximately upper one third of the tarsal plate with three horizontal 6-0 Nylon mattress sutures. The amount of tucking of $M{\ddot{u}}ller^{\prime}s$ muscle was controlled by the location of the upper eyelid margin 2 mm below the upper limbus in primary gaze after first temporary fixations suture in the maximum superior point of the limbus. The amount of advancement of levator aponeurosis was controlled by the location of the upper eyelid margin 1 mm below the upper limbus in primary gaze after first temporary fixations suture in the maximum superior point of the limbus. And then levator aponeurosis was fixed with three horizontal 6-0 Nylon mattress on beside the point that was tucked $M{\ddot{u}}ller^{\prime}s$ muscle. We have been thirty cases with levator and $M{\ddot{u}}ller^{\prime}s$ muscle balanced tucking from January 2004 to Jun 2005. 3 cases were traumatic blepharoptosis with 3-5 mm ptosis and poor levator function. 27 cases were myogenic or aponeurotic blepharoptosis with 2-5 mm ptosis with and more than 4 mm of levator function. the age of the patients ranged from 6 to 78 years. The levator aponeurosis and $M{\ddot{u}}ller^{\prime}s$ muscle tucking procedure can reduce the amount of the levator and $M{\ddot{u}}ller^{\prime}s$ muscle resection, and improve discomfort when the patients open eyes.

Development of Gait Event Detection Algorithm using an Accelerometer (가속도계를 이용한 보행 시점 검출 알고리즘 개발)

  • Choi, Jin-Seung;Kang, Dong-Won;Mun, Kyung-Ryoul;Bang, Yun-Hwan;Tack, Gye-Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.1
    • /
    • pp.159-166
    • /
    • 2009
  • The purpose of this study was to develop and automatic gait event detection algorithm using single accelerometer which is attached at the top of the shoe. The sinal vector magnitude and anterior-posterior(x-axis) directional component of accelerometer were used to detect heel strike(HS) and toe off(TO), respectively. To evaluate proposed algorithm, gait event timing was compared with that by force plate and kinematic data. In experiment, 7 subjects performed 10 trials level walking with 3 different walking conditions such as fast, preferred & slow walking. An accelerometer, force plate and 3D motion capture system were used during experiment. Gait event by force plate was used as reference timing. Results showed that gait event by accelerometer is similar to that by force plate. The distribution of differences were spread about $22.33{\pm}17.45m$ for HS and $26.82{\pm}14.78m$ for To and most error was existed consistently prior to 20ms. The difference between gait event by kinematic data and developed algorithm was small. Thus it can be concluded that developed algorithm can be used during outdoor walking experiment. Further study is necessary to extract gait spatial variables by removing gravity factor.

Study on the Production and Management of Aquatic Animal : Application of ELISPOT-Assay for the Detection of Antibody Secreting Cells in Flounder, Paralichthys olivaceus (수산생물의 생산과 관리에 관한 기초연구 : ELISPOT 기법을 이용한 넙치의 항체생성 세포분석)

  • HA Jai Yi;PARK Jun-Hyo;KIM Myoung Sug;CHUNG Joon-Ki;JEONG Hyun Do
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.4
    • /
    • pp.420-426
    • /
    • 1999
  • We examined the immune response in flounder, Paralichthys olivaceus, with immunization of formalin killed Edwardsiella tarda as an antigen. The ELISPOT-assay (enzyme-linked immunospot assay) was optimized technically and applied to count the number of total and specific antibody secreting cells (TASC and SASC) in lymphocytes of different lymphatic organs. Incubation of lymphocytes on 96 well plate for more than 2.5hrs came out enough time in ELISPOT-assay for counting the antibody secreting cells in the anterior kidney and spleen. However, too much of plate-coated antigen or rabbit anti-flounder immunoglobulin for SASC or TASC counting, respectively, was appeared to decrease the sensitivity of the assay system. Specificity of the system was also confirmed by the absence of TASC in lymphocytes treated with cycloheximide to prevent protein synthesis. The peak numbers of SASC appeared at wk 3 post immunization after that there was a sharp decrease and reached to almost zero at wk 7. In the spleen and kidney, the timing and numbers of SASC on peak response were concurrent without preferential organ distribution. The specific antibody level in the sera increased rapidly between wk 2 and 3 after immunization, i.e. like the specific cellular response found with ELISPOT-assay on that period, However, the remained high level of specific serum antibody from wk 5 after immunization until the end of experiment was clearly distinguishable from the kinetics of SASC response decreased sharply.

  • PDF

Dual Plate Fixation for Periprosthetic Femur Fracture after Total Knee Arthroplasty (슬관절 전치환술 후 발생한 대퇴골 삽입물 주위 골절의 이중 금속판 고정술)

  • Kim, Dong Hwi;Cha, Dong Hyuk;Ko, Kang Yeol
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.26-33
    • /
    • 2021
  • Purpose: This study evaluated the results of dual plate fixation for periprosthetic femur fracture after total knee arthroplasty (TKA). Materials and Methods: From October 2007 to February 2013, 23 cases of periprosthetic femur fracture after TKA were treated at the author's hospital. There were 13 cases of fixation using a medial and lateral dual plate when the stability of the fracture site could not be achieved by one side fixation with a follow-up of more than one year. The cases included no loosening of the femoral component in fractures that were categorized as Lewis-Rorabeck classification II and supracondylar comminuted fractures and elongation of the fracture line to the lateral epicondyle of the femur or stem in the medullary canal. The mean age was 72 years (65-82 years), and 11 cases were female. Three cases had a stem due to revision. The mean bone marrow density was -3.2 (-1.7 to -4.4), and the mean period from primary TKA to periprosthetic fractures was 28 months (1-108 months). The mean follow-up period was 23 months (12-65 months). The medial fracture site was first exposed via the subvastus approach. Second, the supplementary plate was fixed on the lateral side of the fracture using a minimally invasive plate osteosynthesis technique. The average union time, complications, and Hospital for Special Surgery Knee Score (HSS) at the last follow-up were evaluated. Results: The mean union time was 17.4 weeks (7-40 weeks). Two cases showed delayed bone union and nonunion occurred in one case, in whom bone union was achieved three months later after re-fixation using a dual plate with an autogenous bone graft. The mean varusvalgus angulation was 1.67 degrees (-1.2-4.9 degrees), and the mean anterior-posterior angulation was 2.86 degrees (0-4.9 degrees) at the last follow-up. The mean knee range of motion was 90 degrees, and the HSS score was 85 points (70-95 points) at the last follow-up. Conclusion: Dual plate fixation for periprosthetic femur fractures that had not achieved stability by one side plate fixation after TKA showed a good clinical result that allowed early rehabilitation.

A study on sagittal root position of maxillary anterior teeth in Korean (한국인에서 상악 전치의 시상 치근 위치에 대한 연구)

  • Kong, Hyun-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.88-94
    • /
    • 2020
  • Purpose: The purpose of this study was to analyze the sagittal root position of maxillary anterior teeth and report the frequency of each classification in Korean for immediate implant placement. Materials and Methods: A retrospective review of cone-beam computed tomography (cone-beam CT) images was conducted on 120 patients (60 male and 60 female) who fulfilled the inclusion criteria. After reorientation of the axis, cone-beam CT images were evaluated and the relationship of the sagittal root position (SRP) of the maxillary anterior teeth to its associated osseous housing was recorded. Class I, II, and III were classified respectively when the root was positioned on the labial, central, and palatal aspect of the alveolar bone. Class IV was the position that at least two thirds of the root is engaging both the labial and palatal cortical plates. Then, the angulation of the root axis and the alveolar bone axis was measured. Descriptive statistics and Kruskal-Wallis test were used to compare the angulation according to the root position and SRP class. Results: The frequency distribution of sagittal root position of maxillary anterior teeth indicated that 81.1%, 10.3%, 1.9%, and 6.7% were classified as Class I, II, III, and IV, respectively. The sagittal angulation at approximately 77.5% of central incisor, lateral incisor, and canine was < 20 degrees, but the angle at more than 42.7% of canine was ≥ 20 degrees. Within the class, the angulation was statistically significantly greater in Class I (16.19) compared to Class II (8.72) and Class III (9.93), and smaller in Class IV (3.79). Conclusion: Within the limitation of this study, a majority of the maxillary anterior roots were positioned close to the buccal cortical plate. However, some roots have very thin alveolar bone and sagittal angulation larger than 30 degrees. Therefore, cone-beam CT analyses of the sagittal root position and the sagittal angulation are recommended for the selection of the appropriate dental implant treatment approach.