• Title/Summary/Keyword: Anterior implant

Search Result 434, Processing Time 0.023 seconds

Three key factors for successful esthetic anterior implant restoration (성공적인 전치부 심미 임플란트를 위한 3가지 요소)

  • Lim, Pil
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.35-49
    • /
    • 2016
  • With the increasing demand for aesthetic implant dentistry, the importance of implant restoration is emphasized not only in the functional aspect but also in the aesthetic aspect. The aesthetic restoration of dental implants in the anterior maxilla is a challenge for clinicians because it requires proper harmony in three following conditions; reconstruction of hard tissue, soft tissue, and aesthetic prosthesis. The soft tissue aesthetics are dependent upon the condition of the supporting hard tissue because the osseous structure provides a framework for the development of a healthy and aesthetic soft tissue interface. Therefore, the augmentation of hard tissue is a first step and especially, optimal 3-dimensional position of implant is the most important factor in aesthetic implant restoration. The management of soft tissue is a second step, and the final step is a restoration of harmonic prosthesis using provisional restoration with proper emergence profile. This clinical report describes the procedure of bone augmentation in labial dehiscence defect, Vascularized Interpositional Periosteal-Connective Tissue (VIP-CT) flap for aesthetic anterior soft tissue, and the importance of provisional restoration and impression taking stage with customized impression coping.

Reconstruction of Disharmonious Upper Anterior Dentition by Implant Supported Fixed Prosthesis (임플란트 지지 고정성 보철물로 상악 전치부를 수복한 증례)

  • Oh, Sang-Chun;Chee, Young-Deok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.183-192
    • /
    • 2008
  • Modern dental reconstructions do not only aim at restoring the patient's mastication, but rather at improving general well-being and quality of life, especially in terms of esthetics. The media, the internet, advertising, and many other facts of society contribute to an increased cosmetic awareness. A 35-year-old male patient presented with as follows: 1) the porcelain fracture of ceramo-metal restoration on #11 and #23, 2) the inclination of incisal plane to horizontal reference plane, 3) the dental midline deviation to facial midline, and 4) the lack of symmetry on upper anterior dentition. The patient requested an aesthetic improvement using fixed prosthodontics including implant-supported restorations. In the upper anterior region, one of the goals of the conventional as well as implant prosthesis is to achieve restorations with the dental attractiveness and beauty in the respect of dental, dentofacial, and facial compositions. This case report presents geometrically improvement of dental esthetics using conventional and implant prosthesis with soft and hard tissue augmentation.

Multidisciplinary approach of the problem of unaesthetic implants in the maxillary anterior dentition (비심미적 임플란트의 심미성 회복을 위한 다각적 접근법)

  • Joo, Ji-Young;Choi, Jeomil;Lee, Ju-Youn
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.2
    • /
    • pp.126-133
    • /
    • 2015
  • Periodontal tissue destroyed by inflammation is difficult to achieve regeneration of the tissue and esthetic restorations only by surgical methods. In particular, improvement of esthetics is more difficult if the problem is related to the implant. A 23 year old woman suffered from unesthetic anterior implant prosthesis. According to her dental history, a repeated bone graft and soft tissue graft failed at a local dental clinic. It was needed to resolve the inflammation and to improve the esthetics. A free gingival graft and ridge augmentation accompanied by guided bone regeneration and a vascularized interpositional periosteal connective tissue graft was performed. Instead of implant prosthesis, a conventional fixed bridge was adopted for better esthetic result. The patient was satisfied with the esthetic conventional fixed prosthesis. This case report introduces esthetic rehabilitation of unesthetic implant prosthetics in the maxillary anterior dentition by a combination of surgical and prosthetic approaches.

Characteristics of adhesion areas between the tissue expander and capsule in implant-based breast reconstruction

  • Lim, Yoon Min;Park, Kwang Hyun;Lee, Dong Won;Lew, Dae Hyun;Roh, Tai Suk;Song, Seung Yong
    • Archives of Plastic Surgery
    • /
    • v.46 no.4
    • /
    • pp.330-335
    • /
    • 2019
  • Background The use of anatomic implants has improved the aesthetic results of breast surgery; however, implant malrotation is an uncommon, but serious complication of these procedures. Nevertheless, little research has explored implant adhesion. In this study, we investigated adhesion between the expander and the capsule. Methods Seventy-nine cases of immediate breast reconstruction via two-stage implant-based reconstruction performed between September 2016 and November 2017 were evaluated. Mentor CPX4 expanders were used in 14 breasts, and Natrelle expanders in 65. We analyzed areas of adhesion on the surfaces of the tissue expanders when they were exchanged with permanent implants. We investigated whether adhesions occurred on the cephalic, caudal, anterior, and/or posterior surfaces of the expanders. Results Total adhesion occurred in 18 cases, non-adhesion in 15 cases, and partial adhesion in 46 cases. Of the non-adhesion cases, 80% (n=12) were with Mentor CPX4 expanders, while 94.4% (n=17) of the total adhesion cases were with Natrelle expanders. Of the partial adhesion cases, 90.7% involved the anterior-cephalic surface. The type of tissue expander showed a statistically significant relationship with the number of attachments in both univariate and multivariate logistic regression analyses (P<0.001) and with total drainage only in the univariate analysis (P=0.015). Conclusions We sought to identify the location(s) of adhesion after tissue expander insertion. The texture of the implant was a significant predictor of the success of adhesion, and partial adhesion was common. The anterior-cephalic surface showed the highest adhesion rate. Nevertheless, partial adhesion suffices to prevent unwanted rotation of the expander.

Reliability of a chairside CAD-CAM surgical guide for dental implant surgery on the anterior maxilla: An in vitro study

  • Phyo Ei Ei Htay;Richard Leesungbok;Suk Won Lee;Yu-Jin Jee;Kyung Lhi Kang;Sung Ok Hong
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.5
    • /
    • pp.259-270
    • /
    • 2023
  • PURPOSE. This study evaluated the reliability of the chair-side CAD-CAM surgical guide (CSG) in the anterior maxilla by comparing its accuracy with the laboratory 3D-printed surgical guide (3DSG) and manual surgical guide (MSG) concerning different levels of dentists' surgical experience. MATERIALS AND METHODS. Ten surgical guides of each type (MSG, 3DSG, and CSG) were fabricated on a control study model with missing right and left central incisors. Sixty implants were placed in 30 study models by two dentists (one inexperienced and one experienced) using three different types of surgical guides. Horizontal deviations at shoulder and at apex, vertical, and angular deviations were measured after superimposing the planned and placed implant positions in the software. Kruskal-Wallis and Mann-Whitney U tests were used to compare the accuracy of three types of surgical guides in each dentist group and the accuracy of each surgical guide between two dentists (α = .05). RESULTS. There were no significant differences in any deviations between CSG and 3DSG, apart from angular deviation, for both dentists' groups. Moreover, both CSG and 3DSG showed no significant differences in accuracy between the two dentists (P > .05). In contrast, MSG demonstrated significant differences from CSG and 3DSG and a significant difference in accuracy between the two dentists (P < .05). CONCLUSION. CSG provides superior accuracy to MSG in implant placement in the maxillary anterior region and is comparable to 3DSG at different levels of surgical experience, while offering the benefits of shorter manufacturing time and reduced patient visits.

치조제 분리술을 이용한 임프란트의 식립증례

  • Kim, Mi-Seong;Nam, Ok-Hyeon;Kim, Su-Gwan;Jo, Se-In;Kim, Sik;Kim, Hyeon-Ho;Gwon, Byeong-Gon
    • The Journal of the Korean dental association
    • /
    • v.40 no.9 s.400
    • /
    • pp.709-715
    • /
    • 2002
  • Two patients with sufficient vertical bone height but insufficient bone width in the anterior mandibular edentulous area, less than 6mm in the buccolingual aspect, for implant placement were chosen for treatment with a ridge splitting procedure. The surgical technique involving greenstick fracture is described. This ridge splitting procedure could be simple placement of implants into ideal restorable positions in severely atrophic, knife-edged ridges and predictable for narrow edentulous alveolar ridge augmentation associated with implant placement. We experienced two cases to place implant with insufficient bone width in the anterior mandibular edentulous area for overdenture be ridge splitting technique. Thus, we will report two cases and review of the literature.

  • PDF

Cortical and cancellous bone thickness on the anterior region of alveolar bone in Korean: a study of dentate human cadavers

  • Kim, Heung-Joong;Yu, Sun-Kyoung;Lee, Myoung-Hwa;Lee, Hoon-Jae;Kim, Hee-Jung;Chung, Chae-Heon
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.3
    • /
    • pp.146-152
    • /
    • 2012
  • PURPOSE. The cortical bone thickness on the anterior region is important for achieving implant stability. The purpose of this study was to examine the thickness of the cortical and cancellous bones on the anterior region of the maxilla and mandible. MATERIALS AND METHODS. Twenty-five cadaver heads were used (16 male and 9 female; mean death age, 56.7 years). After the long axis of alveolar process was set up, it was measured in 5 levels starting from 2 mm below the cementoenamel junction (L1) at intervals of 3 mm. All data was analysed statistically by one-way ANOVA at the .05 significance level. RESULTS. The cortical bone thickness according to measurement levels in both the labial and lingual sides increased from L1 to L5, and the lingual side below L3 was significantly thicker than the labial side on the maxilla and mandible. In particular, the labial cortical bone thickness in the maxilla was the thinnest compared to the other regions. The cancellous bone thickness according to measurement levels increased from L1 to L5 on the maxilla, and on the mandible it was the thinnest at the middle level of the root. CONCLUSION. For implant placement on the anterior region, a careful evaluation and full knowledge on the thickness of the cortical and cancellous bone are necessary, therefore, these results may provide an anatomic guideline to clinicians.

The use of zirconia hybrid abutment for the anterior esthetic restoration and anterior implant utilizing CAD/CAM technology (캐드캠 기능을 이용한 전치부 심미 수복 및 전치부 임플란트에서 지르코니아 링크 지대주(Hybrid abutment)의 사용)

  • Kim, Jongyub
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.9-21
    • /
    • 2013
  • Aesthetics means differ from cultures and times and also differ from each person's own thinking. But as a restorative dentist who works for esthetic areas, we need to have certain principles and rationale. Some functions in CAD/CAM looks very useful to match harmonious shape to adjacent teeth and also very effective and efficient when compare to the traditional laboratory technics. Also we will discuss about link abutment (Titanium-Zirconia abutment) which we need for dental implant placed anterior area where the soft tissue is thin.

Mini-implant with additional retentive structure by using digital method (부가적인 유지구조를 가진 미니 임플란트의 디지털 수복 증례)

  • Hwang, Su-Hyun;Bae, Eun-Bin;Cho, Won-Tak;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.119-126
    • /
    • 2022
  • Mini-implant has been reported as an alternative method to conventional diameter implants in the treatment of mandibular anterior region with narrow ridge. However, one-piece type mini-implant showed biological and technical complications, such as peri-implantitis by residual cement and prosthetic detachment. Recently, one-piece type mini-implant with additional retentive structure has been introduced to increase the retention and stability of the mini-implant. The mini-implant is based on spreading the upper retentive structure with a spreader and connected it with the inner surface of the zirconia prosthesis. In two cases, we tried to reduce these complications through the mini-implant on the narrow mandibular anterior region, and it was possible to reduce the overall treatment period through a digital system. In this case report, restoration using the digital mini-implant system showed improvement of patient satisfaction on the aspect of function and esthetic in the narrow mandibular anterior region.

An analysis of ITI implants placed in korean patients (한국환자에 매식된 ITI 임플란트에 관한 조사)

  • Chang, Moon-Taek
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.2
    • /
    • pp.361-370
    • /
    • 2002
  • The aim of this study was to analyze various data of 120 non-submerged ITI implants placed in 64 korean adults. The data were retrieved from patients' charts and registered in the computer and coded for a statistical analysis. The results revealed that the most common type of edentulism was a distal extension case, and the largest number of implants were placed in the mandibular first molar position. Implants were placed more frequently in mandibular, posterior position than maxillary, anterior position, respectively. With respect to the implant diameter and length, an implant with 4.1mm in diameter and more than 10mm in length was the most common. Since a molar position was the most prevalent position for implant placement in korean patients, clinicians should be careful about implant diameter which can resist a strong occlusal force expected in the molar position. In addition, the distance to the mandibular canal and the floor of maxillary sinus should be considered to avoid possible damages, such as nerve injury and sinus perforation in selecting a proper implant length.