Browse > Article
http://dx.doi.org/10.4047/jkap.2022.60.1.119

Mini-implant with additional retentive structure by using digital method  

Hwang, Su-Hyun (Department of Prosthodontics, Dental and Life Science Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University)
Bae, Eun-Bin (Department of Prosthodontics, Dental and Life Science Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University)
Cho, Won-Tak (Department of Prosthodontics, Dental and Life Science Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University)
Huh, Jung-Bo (Department of Prosthodontics, Dental and Life Science Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University)
Publication Information
The Journal of Korean Academy of Prosthodontics / v.60, no.1, 2022 , pp. 119-126 More about this Journal
Abstract
Mini-implant has been reported as an alternative method to conventional diameter implants in the treatment of mandibular anterior region with narrow ridge. However, one-piece type mini-implant showed biological and technical complications, such as peri-implantitis by residual cement and prosthetic detachment. Recently, one-piece type mini-implant with additional retentive structure has been introduced to increase the retention and stability of the mini-implant. The mini-implant is based on spreading the upper retentive structure with a spreader and connected it with the inner surface of the zirconia prosthesis. In two cases, we tried to reduce these complications through the mini-implant on the narrow mandibular anterior region, and it was possible to reduce the overall treatment period through a digital system. In this case report, restoration using the digital mini-implant system showed improvement of patient satisfaction on the aspect of function and esthetic in the narrow mandibular anterior region.
Keywords
Dental implant; Digital scan; Mini-implant; Narrow ridge;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Galindo-Moreno P, Nilsson P, King P, Worsaae N, Schramm A, Padial-Molina M, Maiorana C. Clinical and radiographic evaluation of early loaded narrow-diameter implants: 5-year follow-up of a multicenter prospective clinical study. Clin Oral Implants Res. 2017;28:1584-91.   DOI
2 Griffitts TM, Collins CP, Collins PC. Mini dental implants: an adjunct for retention, stability, and comfort for the edentulous patient. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2005;100:e81-4.   DOI
3 Buser D, Mericske-Stern R, Bernard JP, Behneke A, Behneke N, Hirt HP, Belser UC, Lang NP. Long-term evaluation of non-submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants. Clin Oral Implants Res 1997;8:161-72.   DOI
4 Klein MO, Schiegnitz E, Al-Nawas B. Systematic review on success of narrow-diameter dental implants. Int J Oral Maxillofac Implants 2014;29:43-54.   DOI
5 Goiato MC, Sonego MV, Pellizzer EP, Gomes JML, da Silva EVF, Dos Santos DM. Clinical outcome of removable prostheses supported by mini dental implants. A systematic review. Acta Odontol Scand 2018;76:628-37.   DOI
6 Park JH, Lee JY, Ryu JJ, Shin SW. Mandibular implant supported overdentures with two different mini-implant systems: A case report. J Korean Acad Prosthodont 2016;54:267-72.   DOI
7 Parize HN, Bohner LOL, Gama LT, Porporatti AL, Mezzomo LAM, Martin WC, Goncalves TMSV. Narrow-diameter implants in the anterior region: A meta-analysis. Int J Oral Maxillofac Implants 2019;34:1347-58.   DOI
8 Parel SM, Schow SR. Early clinical experience with a new one-piece implant system in single tooth sites. J Oral Maxillofac Surg 2005;63:2-10.   DOI
9 Vigolo P, Givani A. Clinical evaluation of single-tooth mini-implant restorations: a five-year retrospective study. J Prosthet Dent 2000;84:50-4.   DOI
10 Song SR, Park KM, Jung BY. Fracture strength analysis of titanium insert-reinforced zirconia abutments according to the axial height of the titanium insert with an internal connection. PLoS ONE 2021;16:e0249208.   DOI
11 Jeong B, Lee Y, Hong SJ, Paek J, Noh K, Pae A, Kim HS, Kwon KR. Accuracy of implant digital scans with different intraoral scanbody shapes and library merging according to different oral exposure height. J Korean Acad Prosthodont 2021;59:27-35.   DOI
12 Wu AY, Hsu JT, Chee W, Lin YT, Fuh LJ, Huang HL. Biomechanical evaluation of one-piece and two-piece small-diameter dental implants: In-vitro experimental and three-dimensional finite element analyses. J Formos Med Assoc 2016;115:794-800.   DOI
13 Flanagan D, Mascolo A. The mini dental implant in fixed and removable prosthetics: a review. J Oral Implantol 2011;37:123-32.   DOI
14 Mohan CS, Harinath P, Cholan PK, Kumar DL. Predictable aesthetic outcome with immediate placement and early loading of one piece mini implant - A 5 year follow-up case report. J Int Oral Health 2014;6:132-5.
15 Huh JB, Ko SM. The comparative study of thermal inductive effect between internal connection and external connection implant in abutment preparation. J Korean Acad Prosthodont 2007;45:60-70.
16 Reddy MS, O'Neal SJ, Haigh S, Aponte-Wesson R, Geurs NC. Initial clinical efficacy of 3-mm implants immediately placed into function in conditions of limited spacing. Int J Oral Maxillofac Implants 2008;23:281-8.
17 Kim YK, Yeo IS, Yi YJ, Kim UK, Moon KN, Jeon SJ, Cho YS, Yun PY. Multicentric retrospective clinical study on the clinical application of mini implant system. J Korean Assoc Oral Maxillofac Surg 2010;36:325-30.   DOI
18 Nogueira LB, Moura CD, Francischone CE, Valente VS, Alencar SM, Moura WL, Soares Martins GA. Fracture strength of implant-supported ceramic crowns with customized zirconia abutments: screw retained vs. cement retained. J Prosthodont 2016;25:49-53.   DOI
19 Abduo J, Lyons K, Bennamoun M. Trends in computer-aided manufacturing in prosthodontics: a review of the available streams. Int J Dent 2014;2014:783948.   DOI
20 Jackson BJ. Small diameter implants: specific indications and considerations for the posterior mandible: a case report. J Oral Implantol 2011;37:156-64.   DOI