• 제목/요약/키워드: Ankle Range of Motion

Search Result 291, Processing Time 0.026 seconds

The Comparison Study of Ankle Joint Mobilization and Elongation on the Difference of Weight-bearing Load, Low Back Pain and Flexibility in Flat-foots Subjects (편평족에 대한 관절가동술과 자가신장이 요부의 신장성, 요통과 하지 체중부하 차이에 대한 비교 연구)

  • Park, Sung-doo;Yu, Dal-yeong
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.23 no.2
    • /
    • pp.9-16
    • /
    • 2017
  • Background: The purpose of this study was to investigate the relationship between the spine and the flat-foot, the stability and the alignment of the posture of the neck to prevent the alignment of the ankle joint operation and the lower back flexibility of the lumbar region according to the type of treatment using active stretching of the triceps, back pain, and to see how they affect weight bearing differences. Methods: The subjects of this study were 24 chronic low back pain patients. They were randomly divided into experimental group and control group. In the experimental group, ankle joint mobilization and active scraping of triceps were performed three times a week for a total of 6 weeks. The control group was performed in the same way without articulation. The range of flexion and extension motion of the lumbar spine and pain degree and difference of weight-bearing were measured before and after the experiment. Results: The model of ankle joint mobilization and calf muscle elongation of flat foot significantly improved the range of flexion and extension motion of the vertebrae (p<.05) and the VAS and distribution of weight-bearing were decreased in both of two groups (p<.05). In other words, the exercise and mobilization help to recover of the balance of the whole musculoskeletal, the vertebrae. Conclusions: The active exercise of the triceps muscle of the lower leg in this study It affects the flexibility of the lumbar spine, the pain and the difference in the weight support of the lower extremities, when we performed ankle joint mobilization for exercise and cramping, pain and the difference in weight support between the two lower limbs.

  • PDF

Effect of the Instrument Assisted Soft Tissue Mobilization and Static Stretching on the Range of Motion and Plantar Foot Pressure of an Ankle Joint (도구를 이용한 연부조직가동술과 정적 스트레칭이 족저압과 발목관절 가동범위에 미치는 영향)

  • Lee, Jae-hong;Lee, Jin-hwan;Min, Dong-ki;Kim, Kwang-su;Kim, Jong-woo
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.23 no.2
    • /
    • pp.27-32
    • /
    • 2017
  • Background: The purpose of this study was to compare the effects of IASTM and static stretching techniques on ankle joint range of motion (ROM), static foot pressure. Methods: Twenty four subjects with gastrocnemius shortness participated in this study. The subjects were assigned randomly to one of two groups: The soft tissue mobilization technique (IASTM) group received intervention using a IASTM instrument for two minutes, and the stactic stretching group performed self stretching for 30 seconds, four times. The ROM of the ankle joint was measured by active ankle dorsi-flexion test, and a TPScan was utilized to collect the plantar foot pressure. This experiment was performed by two physical therapists. The significant level was set at ${\alpha}=.05$. Results: The results were as follows: 1) The ROM of the ankle joint and was significantly increased in both groups. 2) Plantar foot pressure was no significant in both groups. 3) There were no significant differences between the IASTM group and static stretching group for any variable. Conclusions: The results of this study suggest that static stretching is an effective and easy technique for restoring proper muscle length in subjects with gastrocnemius shortness. We recommend that static stretching technique be used for treat gastrocnemius shortness in clinical setting and home program.

  • PDF

Immediate Effects of Frequency-dependent Electrotherapy on the Gait and Ankle Range of Motion of Chronic Stroke Patients (주파수에 따른 전기치료가 만성 뇌졸중 환자의 보행 및 발목 관절가동범위에 즉각적으로 미치는 영향)

  • Cho, Kyun-Hee;Kim, Tae-Hyun;Park, Shin-Jun
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.10
    • /
    • pp.220-226
    • /
    • 2019
  • Transcutaneous electrical nerve stimulation and interferential current therapy were applied to the plantar flexor of the stroke patients, and the immediately effects on gait and ankle ROM were investigated. TENS group (n=15) and ICT group (n=15) were applied to the paretic side plantar flexor, respectively. After 60 minutes of application, evaluation of the gait and passive ankle dorsiflexion range of motion (ROM) using smartphone. After 60 minutes of application, immediate post evaluation was carried out. Two electrotherapy methods showed a significant increase in gait speed, cadence, and ankle ROM. Two electrotherapy methods were intervention methods that could increase the gait and ankle ROM of stroke patients. More subjects will be needed to pinpoint differences between the two electrotherapy methods.

Characteristics of ROM and EMG to Balance Training in Unstable Plate System: Primary Study (균형 훈련 플레이트 시스템을 이용한 생체역학적 특성 연구)

  • Jun, SungChul;Lim, HeeChul;Lee, ChangHyung;Kim, TaeHo;Jung, DukYoung;Chun, KeyoungJin
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.235-239
    • /
    • 2015
  • The purpose of this study was to investigate the unstable plate system for the advanced balance ability. 7 male volunteers (age $33.7{\pm}1.2$ years, height $174.7{\pm}3.8cm$, weight $86.0{\pm}3.6kg$, BMI $28.2{\pm}2.0kg/m^2$) performed the partial squat motion on the shape of CAP type(${\cap}$) and BOWL type(${\cup}$) plate system. The range of motion (ROM) and muscle activation were acquired by the motion analysis system and the EMG system. Results of ROMs of the CAP type plate system were shown the widely range of the deviation in the ankle joint on the sagittal plane (sagittal plane - hip joint $10.7^{\circ}$ > $5.4^{\circ}$, knee joint $16.3^{\circ}$ > $6.4^{\circ}$, ankle joint $18.8^{\circ}$ > $6.3^{\circ}$ ; transverse plane - hip joint $3.5^{\circ}$ > $1.8^{\circ}$, knee joint $5.3^{\circ}$ > $3.4^{\circ}$, ankle joint $11.3^{\circ}$ > $5.3^{\circ}$ ; frontal plane - hip joint $0.9^{\circ}$ > $0.5^{\circ}$, knee joint $0.8^{\circ}$ > $0.6^{\circ}$, ankle joint $4.8^{\circ}$ > $3.7^{\circ}$). Muscle activation results of the CAP type plate system were indicated higher in major muscles for balance performance than the BOWL type plate system (vastus lateralis 0.90 > 0.62, peroneus longus 0.49 > 0.21, biceps femoris 0.38 > 0.14, gastrocnemius 0.11 > 0.05). These findings may indicate that the CAP type plate system would expect better effectiveness in perform the balance training. This paper is primary study for developing balance skills enhancement training device.

Gait Analysis on Unexpected Missing Foot Steps (헛디딤 보행특성 분석)

  • Hwang, Sun-Hong;Ryu, Ki-Hong;Keum, Young-Kwang;Kim, Young-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.1 s.190
    • /
    • pp.85-92
    • /
    • 2007
  • In the present study, three-dimensional motion analyses were performed to determine biomechanics of the lower extremity in unexpected missing foot steps for ten healthy young volunteers. In unexpected missing foot steps, the whole plantar surface of the foot or the heel contacted to the ground. A rapid ankle dorsiflexion was found right after missing foot steps and an increased plantarflexion moment was noted during loading response. After the unexpected situation, the breaking force increased rapidly. At this time, both tibialis anterior and soleus were simultaneously activated. Moreover, the range of motion at ankle, knee and hip significantly decreased during stance. In pre-swing, rectus femoris and biceps femoris prevented the collapse of the lower limbs. During late stance, propulsive forces decreased and thus, both plantarflexion moment and power generation were significantly reduced. On the opposite side, hip extension and pelvic upward motion during terminal swing were significant. Due to the shortened pre-swing, the energy generation at the ankle to push sufficiently off the ground was greatly reduced. This preliminary study would be helpful to understand the biomechanics of unexpected dynamic perturbations and valuable to prevent frequent falling of the elderly and patients with gait disorders.

Development of Joint Angle Measurement System for the Feedback Control in FES Locomotion (FES보행중의 피드백제어를 위한 관절 각도계측 시스템 개발)

  • Moon, Ki-Wook;Kim, Chul-Seung;Kim, Ji-Won;Lee, Jea-Ho;Kwon, Yu-Ri;Kang, Dong-Won;Khang, Gon;Kim, Yo-Han;Eom, Gwang-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.203-209
    • /
    • 2009
  • The purpose of this study is to develop a minimally constraint joint angle measurement system for the feedback control of FES (functional electrical stimulation) locomotion. Feedback control is desirable for the efficient FES locomotion, however, the simple on-off control schemes are mainly used in clinic because the currently available angle measurement systems are heavily constraint or cosmetically poor. We designed a new angle measurement system consisting of a magnet and magnetic sensors located below and above the ankle joint, respectively, in the rear side of ipsilateral leg. Two magnetic sensors are arranged so that the sensing axes are perpendicular each other. Multiple positions of sensors attachment on the shank part of the ankle joint model and also human ankle joint were selected and the accuracy of the measured angle at each position was investigated. The reference ankle joint angle was measured by potentiometer and motion capture system. The ankle joint angle was determined from the fitting curve of the reference angle and magnetic flux density relationship. The errors of the measured angle were calculated at each sensor position for the ankle range of motion (ROM) $-20{\sim}15$ degrees (dorsiflexion as positive) which covers the ankle ROM of both stroke patients and normal subjects during locomotion. The error was the smallest with the sensor at the position 1 which was the nearest position to the ankle joint. In case of human experiment, the RMS (root mean square) errors were $0.51{\pm}1.78(0.31{\sim}0.64)$ degrees and the maximum errors were $1.19{\pm}0.46(0.68{\sim}1.58)$ degrees. The proposed system is less constraint and cosmetically better than the existing angle measurement system because the wires are not needed.

The Effect of Total Contact Inserts on the Gait Parameters During High-Heeled Shoes Walking (높은 굽 신발 보행 시 전면 접촉인솔이 보행 변수에 미치는 영향)

  • Moon, Gon-Sung;Kim, Tack-Hoon
    • Physical Therapy Korea
    • /
    • v.18 no.2
    • /
    • pp.1-8
    • /
    • 2011
  • The purpose of this study was to investigate the effect of high heeled shoes with the total contact insert (TCI) on the frontal plane of the joints for the lower extremity during the gait. Ten healthy females voluntarily participated in this study and the height of the high heeled shoes was 7 cm. A three-dimensional motion analysis system (VICON) and force plates were used to analyze the movements of the joints for the lower extremities. The results were as follows: There were no significant differences for the angle value on the event of the gait cycle in the maximum eversion and inversion of the ankle joint, the varus and valgus of the knee joint, and the adduction and abduction of the hip joint (p>.05). But, there was a significant difference or the range of motion in the ankle joint (p<.05). The value of ankle and knee moment with a TCI was less than the value for no TCI. And there were significant differences for the moment value of the maximum inversion and eversion on the ankle joint and for the maximum varus and valgus on the knee joint (p<.05). Therefore, a TCI would be effective in stabilizing the joints of the lower extremities and increasing the balance of a body to reduce the injure from a fall during the gait.

Ruptured Posterior Tibialis and Flexor Digitorum Longus Tendon in Closed Ankle Fracture (폐쇄성 족관절 골절에 동반된 후경골건 및 장족지 굴건 파열)

  • Park, In-Heon;Lee, Kee-Byoung;Song, Kyung-Won;Lee, Jin-Young;Choi, Min
    • Journal of Korean Foot and Ankle Society
    • /
    • v.2 no.2
    • /
    • pp.93-96
    • /
    • 1998
  • A tibialis posterior and flexor digitorum longus tendon rupture associated with a closed bimalleolar ankle fracture occured in a 30 years old man due to traffic accident. The tendon injury was not recognized before surgery but was diagnosed at the time of operation. The treatment was open reduction and internal fixation of the ankle fracture with primary repair of the ruptured tendons. one year postoperatively, he had a nearly full range of ankle and toes motion without pain and a radiologic normal longitudinal arch. This associated tendon injury, although rare, maybe first time in reviewed similar reports, should be considered in the management of ankle fracture because the tendon rupture could easily have been overlooked.

  • PDF

Distraction Arthroplasty as Treatment for Ankle Osteoarthritis (신연 관절 성형술을 이용한 족근 관절 골관절염의 치료증)

  • Park, Yong-Wook;Kim, Do-Young;Lee, Sang-Soo;Lim, Chang-Kyun;Park, Hyun-Chul
    • Journal of Korean Foot and Ankle Society
    • /
    • v.6 no.2
    • /
    • pp.161-166
    • /
    • 2002
  • Purpose: To evaluate the effectiveness of distraction arthroplasty as treatment for moderate or severe ankle osteoarthritis Materials and Methods: Thirteen patients who underwent distraction arthroplasty using the Ilizarov external fixator were available. We removed osteophytes around the ankle before applying the external fixator. We encourage the patients to do active range of motion exercise and to walk with cruch. Follow-up averaged 15 months (range, 10-31 months). Both the patients' postoperative satisfaction and the radiographic joint space were retrospectively evaluated. Results: The duration from applying the external fixator to remove was 12 weeks. Breakage of the wire applied to the forefoot occurred in 2 cases. All patients satisfied with the postoperative clinical results. The ankle joint space averaged $1.6{\pm}0.2mm$ in pre-operative, $4.2{\pm}0.9mm$ in post-Ilizarov external fixator's removal, and $2.3{\pm}0.3mm$ in last follow-up ankle lateral view. Conclusion: We think that distraction arthroplasty with external fixator is useful operative method for the moderate or severe ankle osteoarthritis.

  • PDF

A Study on the Lower Body Range of Motion(Using a 3-D Motion Analysis System) about Korean Adults (한국성인 남자의 하체 동작범위 연구 - 3D 동작분석 장치를 이용하여 -)

  • 류신아;박길순
    • The Research Journal of the Costume Culture
    • /
    • v.8 no.5
    • /
    • pp.741-753
    • /
    • 2000
  • The purpose of this study : 1. The total 24 range measurements of active dynamic motion of 40 subjects(20's and 30's, and 40's∼60's) using previous studies. The results were compared with the other studies in the aspects of age. In this study, The 3-D motion analysis system consists of VICON 140, data acquisition system, and data analysis program called by KRISSMAS. VICON 140 is dynamic motion analyzer, and KRISSMAS is a program developed for analysis of the data captured from the VICON. The results of this study were as follows : 1. Comparing 20's∼30's and 40's∼60's the result shows that 40's∼60's have smaller ROM at the most joints(Thoratic and Lumber, Hip Joint, Knee Joint, Ankle Joint), which is inconsistent with the previous result. The reason is that most investigations were carried out using traditional measurement equipments, which have encountered difficulty in quantifying the exact motion of the body. 2. There are no significant mean difference between the right and the left side. Most of the significances were not high(〉0.05).

  • PDF