• Title/Summary/Keyword: Anionic polymer

Search Result 197, Processing Time 0.019 seconds

The Coagulation Characteristics of Wastewater Using Poly-γ-glutamic Acid (Poly-γ-glutamic acid(PGA)를 이용한 폐수의 응집특성)

  • Kwon, Kwi-bock;Kim, Dong-ha;Kang, Seon-Hong;Sung, Moon-Hee;Park, Chung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.357-362
    • /
    • 2005
  • Poly-${\gamma}$-glutamic acid (${\gamma}-PGA$), which is extracted from fermented soybeans, is a high molecular weight, adhesive, and negatively charged(anionic) polymer. Recently, ${\gamma}-PGA$ has gained attention due to its potential as polymer. The objectives of this study were to examine the applicability of ${\gamma}-PGA$ as a coagulant and/or a coagulant aid, to evaluate the efficiency of ${\gamma}-PGA$ for the removal of Organic and Ammonium substance in wastewater treatment. The effect of coagulation was evaluated for the removal of SS and organic matter using poly aluminum chloride(PACI) as well as newly developed ${\gamma}-PGA$. The maximum COD removal rate of 63% and the SS of 78% were occurred at the dosage of 50mg/L ${\gamma}-PGA$ only. The most effective removal for particulate and organic matter was occured when both PACI and ${\gamma}-PGA$ were applied at the rate of 20:1(10mg/L PACI and 0.5mg/L ${\gamma}-PGA$). When mixed with PACI, only small portion of ${\gamma}-PGA$ was enough to improve removal efficiencies of organic and particulate matter in wastewater. This result showed the positive potential of ${\gamma}-PGA$ as a new coagulant materials for wastewater treatment.

${\cdot}$ 무기 복합 고분자를 이용한 granule의 활성도 실험

  • Jeong, Hyeon-Seong;Kim, Yong-Hwan;Ryu, Jeong-Yong;Song, Bong-Geun;Lee, Sang-Il
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.676-679
    • /
    • 2003
  • Long time over 6 month was required to form granuler sludge, which is critically necessary for UASB reactor. By feeding both high molecular cationic polymer and anionic silica sol to conventional digestion sludge, granular sludge was obtained within 5 minutes. Succession adaptation was performed for granular sludge for 30 days. $80{\sim}90%$ COD removal efficiency was shown with granular sludge, which was comparable with that of typical UASB granular sludge.

  • PDF

Improvements of Strength and Retention of Cotton Handsheet by Additives(I) - Characteristics of Strength and Retention by Additives - (면 수초지의 지력 및 보류 향상을 위한 첨가제의 적용(제 1보) - 첨가제에 따른 지력 및 보류도 특성 -)

  • Cho, Yu-Je;Kim, Kang-Jae;Eom, Tae-Jin
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.45 no.5
    • /
    • pp.23-29
    • /
    • 2013
  • Various properties of cotton handsheet were measured to solve the problem of deformation while storing guar gum(natural polymer) and to improve strength and retention by synthetic polymers(A-PAM, C-PAM, CMC). The results of this study were summarized as follow. The cotton handsheet with 0.2% of A-PAM showed the best tensile index and folding endurance. Retention of fines and fillers in pulp slurry with 0.2% and 0.3% of A-PAM were more excellent than that with guar gum.

Application of Nano-sized Amphiphilic Polyurethane Particles for The Remediation of PAH-Contaminated Soil:Sorption to Soil and PAH Solubilization

  • Park, Heon-Sik;Ahn, Ik-Sung;Kim, Ju-Young;Park, Sung-Yong;Shin, Young-Seob
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.183-186
    • /
    • 2002
  • Experiments in the batch soil/aqueous systems were conducted to compare the sorption onto soil and extraction efficiency of sorbed phenanthrene in the presence of the micelle-forming anionic surfactant(SDS) or the micelle-like amphiphilic nano-sized polyurethane particles. Micelle-like amphiphilic nano-sized polyurethane(APU) particles synthesized from amphiphilic urethane acrylate anionomers(UAA) could solubilize phenanthrene within their hydrophobic interiors as the same way that surfactants micelles did in aqueous phase.

  • PDF

Recycling of Wastepaper(IV) -The effect of polyelectrolytes on recycled KOCC stock- (고지재생연구 (제4보) -고분자 전해질이 KOCC 재생지료에 미치는 영향)

  • 김정은;안인숙;류정용;신종호;송봉근;오세균
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.31 no.1
    • /
    • pp.23-30
    • /
    • 1999
  • The effects of polyelectrolytes and enzyme, alone and in combination, were investigated in OCC recycling system. Four types of the polyelectrolytes based on acrylamide, cationic and anionic monomers were applied to the enzyme-treated KOCC stock to improve the strength and drainage properties of testliner. The polyelectrolytes used in this work were designed in terms of molecular weight and charge density. The water conditions used for recycling were also varied. The results showed that the hydrolytic action of enzyme gave reduced surface area and amorphous region of fiber, and as a result, the cationic polymer was lost apparently its flocculating power due to the reduced bonding site of fiber surface. When the hardness and conductivity of water had been controlled to the conditins of OCC paper mill, the application of amphoteric polyelectrolyte to the enzyme-treated recycled stock was the most effective with respect to the strength and drainage properties of testliner.

  • PDF

Humidity-Sensitive Properties of Self-Assembled Polyelectrolyte System

  • Lee Chil-Won;Kim Jong-Gyu;Gong Myoung-Seon
    • Macromolecular Research
    • /
    • v.13 no.3
    • /
    • pp.265-272
    • /
    • 2005
  • Polyelectrolyte membranes for humidity-sensing were fabricated using a layer-by-layer adsorption process based on the spontaneous self-assembly of alternating layers of cationic and anionic polymers on a silanized ITO patterned glass substrate. The substrate is dipped successively into dilute solutions of a polyanion and a polycation. The homopolymers and copoymers of diallyldimethylammonium chloride (DDA), allylamine hydrochloride (AA), 2-[(methacryloyloxy)ethyl]trimethyl ammonium chloride (METAC) and vinylbenzyl tributyl phosphonium chloride(VTBPC) were used as the polycations. In this experiment, it was found that the resistance varied according to the chemical structure of the polycation. The resistance varied from $10^7$ to $10^5$ $\Omega$, as the humidity was increased from 60 (relative humidity) to $95\%$RH, which is the range of RH values required for a dew sensor operating at high humidity.

Molecular Dynamics Simulation Studies of the Effects of the Protonation State of Chitosan in Interactions with Bacterial Membranes (키토산의 양성자화가 세균막과의 상호작용에 미치는 효과 연구)

  • Truong, Gia Khuong;Yi, Myunggi
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.49 no.6
    • /
    • pp.815-822
    • /
    • 2016
  • The cationic biopolymer chitosan has several applications in medicine. Chitosan is the deacetylated derivative of chitin, the second most abundant naturally occurring polymer. Recent studies have investigated the relationship between chitosan and antibacterial activity. However, the molecular interactions and mechanisms have not been detailed. This study used molecular dynamics simulations to study interactions between chitosan and anionic bacterial membranes (POPE-POPG) and electrically neutral non-bacterial membranes (POPC). We calculated the free energy using umbrella sampling to compare the interactions between membranes and chitosan in different protonation states. Fully protonated chitosan interacted most strongly with the bacterial membranes, but weakly with non-bacterial membranes. These results suggest that electrostatic interactions are the main mechanism of the antibacterial activity of chitosan, and they provide insights into the design of novel antibacterial and antimicrobial agents.

The Analysis of Surface Characteristics of the Hydrophilic Chemicals Treated PET Fibers using Tensiometric Methods (Tensiometric법을 이용한 친수하 PET 섬유의 표면특성 분석)

  • Chung Hae Won;Obendorf S. Kay
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.15 no.4 s.40
    • /
    • pp.431-435
    • /
    • 1991
  • The dispersion and Poiar force components of the surface free energy of PET fibers untreated and treated with hydrophilic chemicals, such as nonionic-soil release polymer (SRP), anionic, nonionic and hydrophilic silicone, were determined using harmonic-mean and geometric-mean methods. Contact angles of water and methylene iodide on the fibers were determined from the adhesion tensions using tensiometric method. Fibers treated with hydrophilic chemicals have the increased polar force component and the decreased dispersion force component. The adhesion tensions of triolein for the hydrophilic treated fibers were smaller than that for untreated fiber.

  • PDF

Self-Assembly Modification of Perfluorosulfonic Acid Membranes for the Application to Direct Methanol Fuel Cells

  • Moon, Go-Young;Rhim, Ji-Won
    • Macromolecular Research
    • /
    • v.16 no.6
    • /
    • pp.524-531
    • /
    • 2008
  • The mitigation or elimination of methanol crossover for perfluorosulfonic acid fuel cell membranes has been investigated extensively for direct methanol fuel cell applications with the aim of increasing the electrochemical performance and enhancing the utilization rate of methanol. Self-assembly modifications by applying an oppositely charged polyelectrolyte to Nafion membranes were attempted in order to block or reduce methanol crossover while maintaining the other advantageous properties of Nafion membranes. It was reported that anionic polyallylamine hydrochloride (PAH) was the most efficient polyelectrolyte in reducing methanol crossover, and considerable cell performance was obtained even at a methanol feed concentration of 10 M.

Characteristics of Drag Reduction Additives in the Application of District Cooling System (지역냉방시스템에의 적용을 위한 마찰저항감소 첨가물 특성 연구)

  • 윤석만;김종보
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.251-257
    • /
    • 2000
  • District heating and cooling systems offer highly efficient energy utilization and maintenance by centralizing heat management. More pumping power, however, is required because the water has to travel long distance from heat source to the users. In the present study, a trace of drag reduction additives is added to the District Cooling system to achieve a significant drag reduction and save pumping power. Water-soluble polymers, surfactants, and environment-friendly degradable polymers are used as effective drag reducing additives. Time dependent percent drag reductions are compared for various additive solutions at 100 wppm concentration for different water velocity. Without as an anionic surfactant, copolymer was most effective in percent drag reduction. It is found that there exists an optimal condition when copolymer is mixed with SDS. An environment-friendly degradable polymer, xanthan gum, is found to be a significant drag reduction additive. Ice slurry systems, can give less pressure drops compared with chilled water system for certain condtions. Drag reduction additives were also effective for the ice slurry system.

  • PDF