Kim, Yong Kwan;Kim, Ha-Young;Jeon, Albert Byungyun;Lee, Myoung-Heon;Bae, You-Chan;Byun, Jae-Won
Korean Journal of Veterinary Research
/
v.54
no.2
/
pp.113-115
/
2014
Salmonella are causative agents of gastroenteritis and systemic disease in animals. The invA gene was selected as a target sequence of loop-mediated isothermal amplification (LAMP) assay for diagnosis of Salmonella infection. The detection limits for broth dilution, spiked feces and enrichment were $10^4$, $10^5$ and $10^2$ CFUs/mL, respectively. The LAMP assay developed in the present study may be a reliable method for detection of Salmonella spp. in pig feces.
Objective: This study aimed to develop loop-mediated isothermal amplification (LAMP) combined with lateral flow dipstick (LFD) and compare it with LAMP-AGE, polymerase chain reaction (PCR), and standard Salmonella culture as reference methods for detecting Salmonella contamination in animal products and animal production environmental samples. Methods: The SalInvA01 primer, derived from the InvA gene and designed as a new probe for LFD detection, was used in developing this study. Adjusting for optimal conditions by temperature, time, and reagent concentration includes evaluating the specificity and limit of detection. The sampling of 120 animal product samples and 350 animal production environmental samples was determined by LAMP-LFD, comparing LAMP-AGE, PCR, and the culture method. Results: Salmonella was amplified using optimal conditions for the LAMP reaction and a DNA probe for LFD at 63℃ for 60 minutes. The specificity test revealed no cross-reactivity with other microorganisms. The limit of detection of LAMP-LFD in pure culture was 3×102 CFU/mL (6 CFU/reaction) and 9.01 pg/μL in genomic DNA. The limit of detection of the LAMP-LFD using artificially inoculated in minced chicken samples with 5 hours of pre-enrichment was 3.4×104 CFU/mL (680 CFU/reaction). For 120 animal product samples, Salmonella was detected by the culture method, LAMP-LFD, LAMP-AGE, and PCR in 10/120 (8.3%). In three hundred fifty animal production environmental samples, Salmonella was detected in 91/350 (26%) by the culture method, equivalent to the detection rates of LAMP-LFD and LAMP-AGE, while PCR achieved 86/350 (24.6%). When comparing sensitivity, specificity, positive predictive value, and accuracy, LAMP-LFD showed the best results at 100%, 95.7%, 86.3%, and 96.6%, respectively. For Kappa index of LAMP-LFD, indicated nearly perfect agreement with culture method. Conclusion: The LAMP-LFD Salmonella detection, which used InvA gene, was highly specific, sensitive, and convenient for identifying Salmonella. Furthermore, this method could be used for Salmonella monitoring and primary screening in animal products and animal production environmental samples.
This report outlines the development of a rapid, simple, and sensitive detection system for pathogenic bacteria using a capillary electrophoresis-based, single strand conformation polymorphism (CE-SSCP) combined with PCR. We demonstrate that this method, used with primers targeting the V4 region of the16S rRNA gene, is capable of the simultaneous detection of 10 microbes that could be associated with foodborne illness, caused by animal-derived foods: Salmonella enterica, Listeria monocytogenes, Escherichia coli O157:H7, Campylobacter jejuni, Staphylococcus aureus, Bacillus cereus, Clostridium perfringens, Yersinia enterocolitica, Vibrio parahaemolyticus, and Enterobacter sakazakii. The traditional detection techniques are time-consuming and labor-intensive, due to the necessary task of separate cultivation of each target species. As such, the CE-SSCP-PCR method, that we have developed, has the potential to diagnose pathogens rapidly, unlike the traditional technique, in order to prevent foodborne illness in a much more efficient manner.
Si Nae Cheon;Geun-Woo Park;Kyu-Hyun Park;Jung Hwan Jeon
Journal of Animal Science and Technology
/
v.65
no.4
/
pp.748-758
/
2023
This study was conducted to investigate the change in activity and mounting behavior in Hanwoo (Korean Native Cattle) during the peri-estrus period and its application to estrus detection. A total of 20 Hanwoo cows were fitted with a neck-collar accelerometer device, which measured the location and acceleration of cow movements and recorded the number of instances of mounting behavior by the altitude data. The data were analyzed in three periods (24-, 6-, and 2-h periods). Blood samples were collected for 5 days after the prostaglandin F2α (PGF2α) injection, and the concentrations of estradiol, progesterone, follicle-stimulating hormone, and luteinizing hormone were determined by enzyme-linked immunosorbent assays. Activity and mounting behavior recorded over 2-h periods significantly increased as estrus approached and were more efficient at detecting estrus than over 24- and 6-h periods (p < 0.05). Endocrine patterns did not differ with the variation of individual cows during the peri-estrus period (p > 0.05). Activity was selected as the best predictor through stepwise discriminant analysis. However, activity alone is not enough to detect estrus. We suggest that a combination of activity and mounting behavior may improve estrus detection efficiency in Hanwoo. Further research is necessary to validate the findings on a larger sample size.
Porcine parvovirus 7 (PPV7) was first detected in Korean pig farms in 2017. The detection rate of PPV7 DNA was 24.0% (30/125) in aborted pig fetuses and 74.9% (262/350) in finishing pigs, suggesting that PPV7 has circulated among Korean domestic pig farms. Phylogenetic analysis based on capsid protein amino acid sequences demonstrated that the nine isolated Korean strains (PPV-KA1-3 and PPV-KF1-6) were closely related to the previously reported USA and Chinese PPV7 strains. In addition, the Korean strains exhibit genetic diversity with both insertion and deletion mutations. This study contributes to the understanding of the molecular epidemiology of PPV7 in Korea.
Kim, Hyoun-Wook;Han, Sang-Ha;Ham, Jun-Sang;Seol, Kuk-Hwan;Jang, Ae-Ra;Kim, Dong-Hun;Oh, Mi-Hwa
Journal of Dairy Science and Biotechnology
/
v.29
no.2
/
pp.51-57
/
2011
Milk and dairy products are nutritionally one of the most important food in human health and the quality of raw milk is significantly important to ensure safety of dairy products. However, milk and dairy products are commonly related with chemical and microbial contaminations. Therefore, rapid and reliable detection of hazardous (e.g. pathogenic bacteria, pesticides, antibiotics, microbial toxins) in milk and dairy products is essential to ensure human health and food safety. Conventional methods for detection of food hazardous are mostly time-consuming to yield a results. Recently, biosensors have been focused as its rapidity and high sensitivity to analyse chemical and microbial hazardous from a variety of foods and environments. This study reviewed the recent trends and applications of biosensors as rapid detection method of hazardous in milk and dairy products.
Kim, Ji-Hyun;Rhim, Seong-Ryul;Kim, Kee-Tae;Paik, Hyun-Dong;Lee, Joo-Yeon
Food Science of Animal Resources
/
v.34
no.5
/
pp.717-723
/
2014
A rapid and specific PCR assay for the simultaneous detection of Listeria monocytogenes, Escherichia coli O157:H7, Bacillus cereus, Salmonella spp., and Staphylococcus aureus in foods was developed to reduce the detection time and to increase sensitivity. Multiplex PCR developed in this study produced only actA, fliC, hbl, invA, ileS amplicons, but did not produce any non-specific amplicon. The primer sets successfully amplified the target genes in the multiplex PCR without any non-specific or additional bands on the other strains. The multiplex PCR assays also amplified some target genes from five pathogens, and multiplex amplification was obtained from as little as 1 pg of DNA. According to the results from the sensitivity evaluation, the multiplex PCR developed in this study detected 10 cells/mL of the pathogens inoculated in milk samples, respectively. The results suggested that multiplex PCR was an effective assay demonstrating high specificity for the simultaneous detection of five target pathogens in food system.
Kim, Hyoun Wook;Kim, Ki-Hwan;Seol, Kuk-Hwan;Oh, Mi-Hwa;Park, Beam Young
Journal of Dairy Science and Biotechnology
/
v.31
no.1
/
pp.59-65
/
2013
Antibiotic residues are undesirable in milk and milk products for a number of reasons. In particular, they can have harmful effects on public health and harm to the manufacturer of the cultured milk products, e.g. MRSA etc. Although government regulatory agencies and the dairy industry have been successful in decreasing the presence of high concentrations of antibiotic residues, violations still occur and lead to contaminated products. As a result, several rapid and reliable methods for the detection of antibiotic residues have been developed, including microbiological and instrumental analysis methods. The conventional methods are time consuming, but recent improvements have allowed for better detection time, sensitivity, and accuracy. An example of an advanced detection instrument is the biosensor, which has several applications in food and environmental science, e.g. food-born pathogen detection, antimicrobial residues etc. In the present review, the recent trends in the methods used to test for antibiotic residues in milk and dairy products, as well as their specific applications, have been discussed.
Kim, Yesol;Shukla, Shruti;Ahmed, Maruf;Son, Seokmin;Kim, Myunghee;Oh, Sejong
Food Science of Animal Resources
/
v.32
no.6
/
pp.706-712
/
2012
The present study was aimed to produce a chicken polyclonal antibody against Cronobacter muytjensii and to develop an immunoassay for its detection. Purification of anti-C. muytjensii IgY from egg yolk was accomplished using various methods such as water dilution and salt precipitation. As a result, sodium dodecyl sulfate-polyacrylamide gel electrophoresis produced two bands around 30 and 66 kDa, corresponding to a light and a heavy chain, respectively. Indirect competitive enzyme-linked immunosorbent assay (IC-ELISA) was performed to determine the effectiveness of the chicken IgY against C. muytjensii. The optimum conditions for detecting C. muytjensii by indirect ELISA and checkerboard titration of the antigen revealed an optimum average absorbance at the concentration of 18 ${\mu}g/mL$, having ca. $10^8$ coated cells per well. The anti-C. muytjensii IgY antibody had high specificity for C. muytjensii and low cross-reactivity with other tested pathogens. In this assay, no cross-reactivity was observed with the other genera of pathogenic bacteria including Escherichia coli O157:H7, Salmonella Typhimurium, Staphylococcus aureus, Bacillus cereus, Enterobacter aerogenes, Salmonella Enteritidis and Listeria monocytogenes. In addition, detection of C. muytjensii in infant formula powder showed a low matrix effect on the detection curve of IC-ELISA for C. muytjensii, with similar detection limit of $10^5$ CFU/mL as shown in standard curve. These findings demonstrate that the developed method is able to detect C. muytjensii in infant formula powder. Due to the stable antibody supply without sacrificing animals, this IgY can have wide applications for the rapid and accurate detection of C. muytjensii in dairy foods samples.
Park, Ji-Hoon;Kim, Hye-Ryung;Chae, Ha-Kyung;Park, Jonghyun;Jeon, Bo-Young;Lyoo, Young S.;Park, Choi-Kyu
Korean Journal of Veterinary Service
/
v.45
no.1
/
pp.19-30
/
2022
In this study, a simple loop-mediated isothermal amplification (LAMP) combined with visual detection method (vLAMP) assay was developed for the rapid and specific detection of African swine fever virus (ASFV), overcoming the shortcomings of previously described LAMP assays that require additional detection steps or pose a cross-contamination risk. The assay results can be directly detected by the naked eye using hydroxynaphthol blue after incubation for 40 min at 62℃. The assay specifically amplified ASFV DNA and no other viral nucleic acids. The limit of detection of the assay was <50 DNA copies/reaction, which was ten times more sensitive than conventional polymerase chain reaction (cPCR) and comparable to real-time PCR (qPCR). For clinical evaluation, the ASFV detection rate of vLAMP was higher than cPCR and comparable to OIE-recommended qPCR, showing 100% concordance, with a κ value (95% confidence interval) of 1 (1.00~1.00). Considering the advantages of high sensitivity and specificity, no possibility for cross-contamination, and being able to be used as low-cost equipment, the developed vLAMP assay will be a valuable tool for detecting ASFV from clinical samples, even in resource-limited laboratories.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.