• Title/Summary/Keyword: Animal Imaging

Search Result 408, Processing Time 0.039 seconds

Intrahepatic Portosystemic Shunt Fixed By Transvenous Coil Embolization in a Samoyed Dog (샤모예드종 개에서 발생한 간내성 문맥-정맥 문합을 경정맥 코일장착으로 치료한 증례)

  • Lee, Moo-Hyun;Lee, Seoung-Jin;Lee, Seung-Gon;Moon, Hyeong-Sun;Lee, Joon-Seok;Choi, Ran;Park, In-Chul;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.24 no.3
    • /
    • pp.426-431
    • /
    • 2007
  • A 5-month-old female Samoyed dog was presented with primary complaints including exercise tolerance and neurological sign associated with hepatic encephalopathy. The major findings in clinical examination included an intermittent seizure, anemia, elevated pre- and post-prandial serum bile acid, hypoproteinemia and bilirubinuria. Diagnostic imaging studies revealed an intrahepatic portosystemic shunt (IPSS). The shunted vessel was successfully occluded by transvenous coil embolization. Clinical signs were gradually improved after shunt occlusion. This case is a rare case of IPSS in a large breed dog fixed by transvenous coil embolization.

Investigation of a Photothrombosis Inducing System for an Observation of Transient Variations in an in vivo Rat Brain

  • Oh, Sung Suk;Park, Hye Jin;Min, Han Sol;Kim, Sang Dong;Bae, Seung Kuk;Kim, Jun Sik;Ryu, Rae-Hyung;Kim, Jong Chul;Kim, Sang Hyun;Lee, Seong-jun;Kang, Bong Keun;Choi, Jong-ryul;Sohn, Jeong-woo
    • Current Optics and Photonics
    • /
    • v.2 no.6
    • /
    • pp.499-507
    • /
    • 2018
  • For the spatiotemporally aligned observation of photothrombosis induction and transient variations of in vivo brain stroke, we developed a novel photothrombosis inducing system compatible to a magnetic resonance imaging (MRI) system using nonmagnetic stereotaxic equipment. From the spatial point of view, the system provides a more reliable level of reproducibility of the photothrombosis in each brain. From the temporal point of view, from T1- and T2-weighted in vivo MR (magnetic resonance) images, the transient variations such as incidence, location, and size of the thrombosis are measured quantitatively. In addition, the final variation is observed in the ex vivo brain by TTC (Triphenyltetrazolium chloride) staining based on histological assay and utilized for the verification of the MR images. From the experimental result of the rat brain, the proposed system shows more reliable characteristics for transient variations of brain strokes.

Clinical Application of MRI in an Animal Bone Graft Model

  • Liu, Xiaochen;Jia, Wenxiao;Jin, Gele;Wang, Hong;Ma, Jingxu;Wang, Yunling;Yang, Yi;Deng, Wei
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.142-149
    • /
    • 2013
  • We aim to monitor vascularization of early bone perfusion following rabbit lumbar intertransverse bone graft fusion surgery using magnetic resonance imaging assessment. Correlation with graft survival status was evaluated by histological method. Experimental animals were randomly divided into three groups and the model was established by operating bilateral lumbar intertransverse bone graft with different types of bone graft substitute material. The lumbar intertransverse area of three groups of rabbits was scanned via MRI. In addition, histological examinations were performed at the $6^{th}$ week after surgery and the quantitative analysis of the osteogenesis in different grafted area was carried out by an image analysis system. The MRI technique can be used for early postoperative evaluation of vascularized bone graft perfusion after transplantation of different bone materials, whereas histological examination allows direct visualization of the osteogenesis process.

Development of a Real-time Medical Imaging System Combined with Laser Speckle Contrast Imaging and Fluorescence Imaging (형광과 레이저 스펙클 대조도 이미징을 결합한 실시간 의료영상 시스템 개발)

  • Shim, Min Jae;Kim, Yikeun;Ko, Taek Yong;Choi, Jin Hyuk;Ahn, Yeh-Chan
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.116-124
    • /
    • 2021
  • It is important to differentiate between the target tissue (or organ) and the rest of the tissue before incision during surgery. And when it is necessary to preserve the differentiated tissues, the blood vessels connected to the tissue must be preserved together. Various non-invasive medical imaging methods have been developed for this purpose. We aimed to develop a medical imaging system that can simultaneously apply fluorescence imaging using indocyanine green (ICG) and laser speckle contrast imaging (LSCI) using laser speckle patterns. We designed to collect images directed to the two cameras on a co-axial optical path and to compensate equal optical path length for two optical designs. The light source used for fluorescence and LSCI the same 785 nm wavelength. This system outputs real-time images and is designed to intuitively distinguish target tissues or blood vessels. This system outputs LSCI images up to 37 fps through parallel processing. Fluorescence for ICG and blood flow in animal models were observed throughout the experiment.

Evaluation of the correlation between the muscle fat ratio of pork belly and pork shoulder butt using computed tomography scan

  • Sheena Kim;Jeongin Choi;Eun Sol Kim;Gi Beom Keum;Hyunok Doo;Jinok Kwak;Sumin Ryu;Yejin Choi;Sriniwas Pandey;Na Rae Lee;Juyoun Kang;Yujung Lee;Dongjun Kim;Kuk-Hwan Seol;Sun Moon Kang;In-Seon Bae;Soo-Hyun Cho;Hyo Jung Kwon;Samooel Jung;Youngwon Lee;Hyeun Bum Kim
    • Korean Journal of Agricultural Science
    • /
    • v.50 no.4
    • /
    • pp.809-815
    • /
    • 2023
  • This study was conducted to find out the correlation between meat quality and muscle fat ratio in pork part meat (pork belly and shoulder butt) using CT (computed tomography) imaging technique. After 24 hours from slaughter, pork loin and belly were individually prepared from the left semiconductors of 26 pigs for CT measurement. The image obtained from CT scans was checked through the picture archiving and communications system (PACS). The volume of muscle and fat in the pork belly and shoulder butt of cross-sectional images taken by CT was estimated using Vitrea workstation version 7. This assemblage was further processed through Vitrea post-processing software to automatically calculate the volumes (Fig. 1). The volumes were measured in milliliters (mL). In addition to volume calculation, a three-dimensional reconstruction of the organ under consideration was generated. Pearson's correlation coefficient was analyzed to evaluate the relationship by region (pork belly, pork shoulder butt), and statistical processing was performed using GraphPad Prism 8. The muscle-fat ratios of pork belly taken by CT was 1 : 0.86, while that of pork shoulder butt was 1 : 0.37. As a result of CT analysis of the correlation coefficient between pork belly and shoulder butt compared to the muscle-fat ratio, the correlation coefficient was 0.5679 (R2 = 0.3295, p < 0.01). CT imaging provided very good estimates of muscle contents in cuts and in the whole carcass.

Diagnostic Imaging Features of Asymptomatic Extrahepatic Portosystemic Shunt Detected by CT in Dogs (개에서 컴퓨터단층촬영술을 이용하여 진단한 임상증상이 없는 간외성 전신문맥단락의 영상학적 평가)

  • Choi, Soo-Young;Lee, In;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.30 no.4
    • /
    • pp.273-277
    • /
    • 2013
  • This study was performed to compare clinical and diagnostic imaging features between asymptomatic and symptomatic extrahepatic portosystemic shunts in dogs. The data of thirty patients diagnosed with extrahepatic PSS by multi-detector CT were reviewed, and the dogs were divided into asymptomatic (9/30) and symptomatic (21/30) groups. Signalments, hematologic results, liver size, morphologic classifications and main portal vein to abdominal aortic ratio (PV/AO) at the porta hepatis level from CT images were evaluated in two groups. Shih-tzu (5/9) was the most frequent breed in asymptomatic group, and various breeds were presented in symptomatic group. Mean age of asymptomatic group ($9.2{\pm}3.2$ years) was significantly higher than that of symptomatic group ($4.5{\pm}3.2$ years). The most morphologic form of shunt vessel was the splenophrenic shunt (16/30). PV/AO of asymptomatic group ($1.1{\pm}0.19$) was significantly higher than the values of symptomatic group ($0.55{\pm}0.19$). Clinical signs, hematologic results and diagnostic imaging findings of asymptomatic PSS are too nonspecific to suspect PSS. Therefore, considering of patient's age and CT examination with application of PV/AO ratio could be useful for the diagnosis of asymptomatic PSS.

Pulmonary Candidiasis in a Dog Receiving Long-term Management for Atopic Dermatitis (아토피성 피부염의 장기 치료중인 개에서 발생한 폐 칸디다증)

  • Han, Jae-Ik;Lee, Chang-Min;Kim, Taewoo;Lee, In;Choi, Soo-Young;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.32 no.3
    • /
    • pp.259-262
    • /
    • 2015
  • A canine patient exhibited partial anorexia and sudden respiratory distress. Diagnostic imaging and cytology of tracheal-lavage fluids revealed fungal pneumonia. Molecular identification and phylogenetic analysis detected Candida catenulata. Treatment with oral itraconazole for 3 weeks was effective. This is the first report of C. catenulata infection in a dog.

Estimation of Internal Motion for Quantitative Improvement of Lung Tumor in Small Animal (소동물 폐종양의 정량적 개선을 위한 내부 움직임 평가)

  • Yu, Jung-Woo;Woo, Sang-Keun;Lee, Yong-Jin;Kim, Kyeong-Min;Kim, Jin-Su;Lee, Kyo-Chul;Park, Sang-Jun;Yu, Ran-Ji;Kang, Joo-Hyun;Ji, Young-Hoon;Chung, Yong-Hyun;Kim, Byung-Il;Lim, Sang-Moo
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.140-147
    • /
    • 2011
  • The purpose of this study was to estimate internal motion using molecular sieve for quantitative improvement of lung tumor and to localize lung tumor in the small animal PET image by evaluated data. Internal motion has been demonstrated in small animal lung region by molecular sieve contained radioactive substance. Molecular sieve for internal lung motion target was contained approximately 37 kBq Cu-64. The small animal PET images were obtained from Siemens Inveon scanner using external trigger system (BioVet). SD-Rat PET images were obtained at 60 min post injection of FDG 37 MBq/0.2 mL via tail vein for 20 min. Each line of response in the list-mode data was converted to sinogram gated frames (2~16 bin) by trigger signal obtained from BioVet. The sinogram data was reconstructed using OSEM 2D with 4 iterations. PET images were evaluated with count, SNR, FWHM from ROI drawn in the target region for quantitative tumor analysis. The size of molecular sieve motion target was $1.59{\times}2.50mm$. The reference motion target FWHM of vertical and horizontal was 2.91 mm and 1.43 mm, respectively. The vertical FWHM of static, 4 bin and 8 bin was 3.90 mm, 3.74 mm, and 3.16 mm, respectively. The horizontal FWHM of static, 4 bin and 8 bin was 2.21 mm, 2.06 mm, and 1.60 mm, respectively. Count of static, 4 bin, 8 bin, 12 bin and 16 bin was 4.10, 4.83, 5.59, 5.38, and 5.31, respectively. The SNR of static, 4 bin, 8 bin, 12 bin and 16 bin was 4.18, 4.05, 4.22, 3.89, and 3.58, respectively. The FWHM were improved in accordance with gate number increase. The count and SNR were not proportionately improve with gate number, but shown the highest value in specific bin number. We measured the optimal gate number what minimize the SNR loss and gain improved count when imaging lung tumor in small animal. The internal motion estimation provide localized tumor image and will be a useful method for organ motion prediction modeling without external motion monitoring system.

Research about Hyperspectral Imaging System for Pre-Clinical testing of Small Animal (소형동물 전임상실험을 위한 하이퍼스펙트럼 영상장비 연구)

  • Lee, kyeong-Hee;Choi, Young-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2208-2213
    • /
    • 2007
  • In this study we have developed a hyperspectrum imaging system for highly sensitive and effective imaging analysis. An optical setup was designed using acoustic optical tunable filter (AOTF) for high sensitive hyperspectrum imaging. Light emitted by mercury lamp gets split in to diffracted and undiffracted beams while passing though AOTF. GFP transfected HEK-293 cell line was used as a model for in vitro imaging analysis. Cells were first, analyzed by fluorescence microscope followed by flow cytometric analysis. Flow cytometric analysis showed 66.31% transfection yield in GFP transfected HEK-293 cells. Various images of GFP transfected HEK-293 cell were grabbed by collecting the diffracted light using a CCD over a dynamic range of frequency of 129-171 MHz with an interval of 3 MHz. Subsequently, for in vivo image analysis of GFP transfected cells in mouse, a whole-body-imaging system was constructed. The blue light of 488 nm wavelength was obtained from a Xenon arc lamp using an appropriate filter and transmitted through an optical cable to a ring illuminator. To check the efficacy of the newly developed whole-body-imaging system, a comparative imaging analysis was performed on a normal mouse in presence and absence of Xenon arc irradiation. The developed hyperspectrum imaging analysis with AOTF showed the highest intensity of green fluorescent protein at 153 MHz of frequency and 494 nm of wavelength. However, the fluorescence intensity remained same as that of the background below 138 MHz (475 nm) and above 162 MHz (532 nm). The mouse images captured using the constructed whole-body-imaging system appeared monochromatic in absence of Xenon arc irradiation and blue when irradiated with Xenon arc lamp. Nevertheless, in either case mouse images appeared clearly.