• 제목/요약/키워드: Angulation

검색결과 295건 처리시간 0.02초

심미적 영역에서 즉시 임플란트 식립 및 임시 수복을 통한 단일치의 수복에 대한 증례 보고 (Immediate implant placement and provisionalization of single implant in the esthetic region : Cases report)

  • 이성배;박유선;김병헌;이보아;최성호;김영택
    • 대한치과의사협회지
    • /
    • 제58권2호
    • /
    • pp.83-92
    • /
    • 2020
  • In the anterior maxillary area, dental implants for tooth replacement are challenging due to the need to satisfy high esthetic level as well as functionality. Immediate implant placement and provisionalization can dramatically reduce the edentulous period, and then fulfill patient's demand for esthetics. The aim of present case report is to demonstrate two cases that successfully restored single tooth with immediate implant placement and provisionalization in the anterior maxillary area. A 47 years old female was scheduled to replace her maxillary right central incisor due to crown-root fracture by trauma. Another 54-year-old female was planned to place dental implant following tooth extraction of maxillary right lateral incisor owing to continuous pus discharge despite repetitive treatments including apicoectomy. In these two cases, surgical and prosthetic procedures progressed in a similar way. After minimal flap elevation, atraumatic tooth extraction was performed. Implant was placed in proper 3-dimensional position and angulation with primary stability. Bone graft or guided bone regeneration for peri-implant bone defect was conducted simultaneously. Provisionalization without occlusal loading was carried out at the same day. Each definitive crown was delivered at 7 and 5 months after the surgery. Two cases have been followed uneventfully for 2 to 5 years of loading time. In conclusion, Immediate implant placement and provisionalization could lead to esthetic outcome for single tooth replacement with dental implant under proper case selection.

  • PDF

Effects of bracket slot size during en-masse retraction of the six maxillary anterior teeth using an induction-heating typodont simulation system

  • Kim, Ji-Yong;Yu, Won-Jae;Koteswaracc, Prasad N.K.;Kyung, Hee-Moon
    • 대한치과교정학회지
    • /
    • 제47권3호
    • /
    • pp.158-166
    • /
    • 2017
  • Objective: To investigate how bracket slot size affects the direction of maxillary anterior tooth movement when en-masse retraction is performed in sliding mechanics using an induction-heating typodont simulation system. Methods: An induction-heating typodont simulation system was designed based on the Calorific Machine system. The typodont included metal anterior and resin posterior teeth embedded in a sticky wax arch. Three bracket slot groups (0.018, 0.020, and 0.022 inch [in]) were tested. A retraction force of 250 g was applied in the posterior-superior direction. Results: In the anteroposterior direction, the cusp tip of the canine in the 0.020-in slot group moved more distally than in the 0.018-in slot group. In the vertical direction, all six anterior teeth were intruded in the 0.018-in slot group and extruded in the 0.020- and 0.022-in slot groups. The lateral incisor was significantly extruded in the 0.020- and 0.022-in slot groups. Significant differences in the crown linguoversion were found between the 0.018- and 0.020-in slot groups and 0.018- and 0.022-in slot groups for the central incisor and between the 0.018- and 0.022-in slot groups and 0.020- and 0.022-in slot groups for the canine. In the 0.018-in slot group, all anterior teeth showed crown mesial angulation. Significant differences were found between the 0.018- and 0.022-in slot groups for the lateral incisor and between the 0.018- and 0.020-in slot groups and 0.018- and 0.022-in slot groups for the canine. Conclusions: Use of 0.018-in slot brackets was effective for preventing extrusion and crown linguoversion of anterior teeth in sliding mechanics.

족근 관절 관절염에서 족관절 유합술의 결과: 전방 도달법과 경비골 도달법 비교 (Ankle Arthrodesis Outcomes in Ankle Osteoarthritis: Comparison between Anterior Approach and Transfibular Approach)

  • 박치형;이준영;정연주
    • 대한족부족관절학회지
    • /
    • 제18권4호
    • /
    • pp.189-194
    • /
    • 2014
  • Purpose: The purpose of this study was to compare the clinical and radiologic results of arthrodesis between anterior approach and transfibular approach arthrodesis in ankle arthritis. Materials and Methods: There were 61 cases of ankle arthritis treated by anterior or transfibular ankle arthrodesis in our hospital from April 2008 to March 2012. We investigated 29 cases (27 patients) who underwent ankle arthrodesis with an anterior approach (15 cases) and transfibular approach (14 cases), and were followed for over two years. Clinically, American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, pain visual analogue scale (VAS), and subjective satisfaction degrees were evaluated. In addition, ankle coronal and sagittal alignments were evaluated using plain radiographs at 6 and 24 months, postoperatively. Results: Clinically, preoperative mean AOFAS score and VAS was 41.3 and 6.4, and were changed to 58.9 and 3.3 postoperatively in the anterior approach group. In the transfibular approach group, preoperative mean AOFAS score was 36.6 and VAS was 7.1, and they were changed to 54.9 and 3.4 postoperatively. However, no significant differences in the clinical results were observed between the two groups (p=0.297). Duration of attaining union was 8.1 weeks in the anterior approach group and 10.4 weeks in the transfibular approach group. Complications were delayed union in one case, nonunion in three cases, cancellous screw breakage in three cases, and complex regional reflex syndrome in one case. Conclusion: After transfibular ankle arthrodesis as treatment of ankle osteoarthritis, the tendency for valgus angulation of the ankle at the final follow-up was observed and 6.5 mm cancellous screw breakage occurred frequently. Therefore, in order to achieve better stability, it is necessary to use 6.5 mm cannulated screws rather than 6.5 mm cancellous screws for ankle arthrodesis.

Morphometric Variations in the Volar Aspect of the Distal Radius

  • Kwon, Bong Cheol;Lee, Joon Kyu;Lee, Suk Yoon;Hwang, Jae Yeun;Seo, Jang-Hyeon
    • Clinics in Orthopedic Surgery
    • /
    • 제10권4호
    • /
    • pp.462-467
    • /
    • 2018
  • Background: Significant discrepancy exists between anatomical plate designs and the anatomy of the native distal radius, which may be attributable to considerable morphometric variations in the volar aspect of the distal radius. We aimed to evaluate the degree of variability in the morphometry of the distal radius and identify factors associated with this variability. Methods: We measured the volar surface angle (VSA) of the intermediate and lateral columns and the volar surface width (VSW) in the distal radius from three-dimensional computed tomography scans acquired from 81 cadaveric forearms. These morphometric parameters were compared between the lateral and intermediate columns, between males and females, and between Koreans and Caucasians. Caucasian morphometric data were obtained and pooled from the previous studies. The coefficient of variation was used to assess the variability of the parameters and Cohen's d to estimate the effect size of the difference between groups. Results: The average VSA of the lateral column was $22^{\circ}{\pm}6^{\circ}$, and that of the intermediate column was $29^{\circ}{\pm}8^{\circ}$ in Koreans (p < 0.001). The variability was high for both VSAs. The VSA of the intermediate column was significantly larger in males than in females (p < 0.001) and in Caucasians than in Koreans (p < 0.001). The average VSW of distal radius was $30{\pm}3mm$ at the watershed line, and it became narrower proximally. The VSW was significantly larger in males than in females (p < 0.001) and in Koreans than in Caucasians (p < 0.001). The effect sizes of the difference for the VSA and VSW between sexes, races and columns were medium to large. Conclusions: Considerable variability exists in the morphometry of the volar distal radius, with sex, race, and column as contributing factors. These results suggest that surgeons should carefully choose an anatomical volar locking plate with appropriate angulation characteristics for each patient to achieve patient-specific alignment of the distal radius.

상악전치부 결손부에서 골유도재생술식을 동반한 임플란트 수복의 증례보고 (Ridge augmentation and implant placement on maxillary anterior area with deficient alveolar ridge : case report)

  • 홍은진;고미선;정양훈;윤정호
    • 대한치과의사협회지
    • /
    • 제57권3호
    • /
    • pp.149-160
    • /
    • 2019
  • Atrophic alveolar ridge of maxillary anterior area is commonly observed after the extraction of teeth in patients with severely compromised periodontal disease, causing difficulties with implant placement. Successful esthetics and functional implant rehabilitation rely on sufficient bone volume, adequate bone contours, and ideal implant positioning and angulation. The present case report categorized the ridge augmentation techniques using guided bone regeneration (GBR) on the maxillary anterior site by Seibert classification. Case I patient presented for implant placement in the position of tooth #11. The alveolar ridge was considered a Seibert classification I ridge defect. Simultaneous implant placement and GBR were performed. Eight months after implantation, clinical and radiological examinations were performed. Case III patient presented with discomfort due to mobility of the upper maxillary anterior site. Due to severe destruction of alveolar bone, teeth #11 and #12 were extracted. After three months, the alveolar ridge was considered a Seibert classification III ridge defect. A GBR procedure was performed; implantation was performed 6 months later. Approximately 1-year after implantation, clinical and radiological examinations were performed. During the whole treatment period, healing was uneventful without membrane exposure, severe swelling, or infection in all cases. Radiographic and clinical examinations revealed that atrophic hard tissues and buccal bone contour were restored to the acceptable levels for implant placement and esthetic restoration. In conclusion, severely resorbed alveolar ridge of the maxillary anterior area can be reconstructed with ridge augmentation using the GBR procedure so that dental implants could be successfully placed.

  • PDF

Three-dimensional evaluation of the transfer accuracy of a bracket jig fabricated using computer-aided design and manufacturing to the anterior dentition: An in vitro study

  • Park, Jae-Hyun;Choi, Jin-Young;Kim, Seong-Hun;Kim, Su-Jung;Lee, Kee-Joon;Nelson, Gerald
    • 대한치과교정학회지
    • /
    • 제51권6호
    • /
    • pp.375-386
    • /
    • 2021
  • Objective: To evaluate the accuracy of a one-piece bracket jig system fabricated using computer-aided design and manufacturing (CAD/CAM) by employing three-dimensional (3D) digital superimposition. Methods: This in vitro study included 226 anterior teeth selected from 20 patients undergoing orthodontic treatment. Bracket position errors from each of the 40 arches were analyzed quantitatively via 3D digital superimposition (best-fit algorithm) of the virtual bracket and actual bracket after indirect bonding, after accounting for possible variables that may affect accuracy, such as crowding and presence of the resin base. Results: The device could transfer the bracket accurately to the desired position of the patient's dentition within a clinically acceptable range of ± 0.05 mm and 2.0° for linear and angular measurements, respectively. The average linear measurements ranged from 0.029 to 0.101 mm. Among the angular measurements, rotation values showed the least deviation and ranged from 0.396° to 0.623°. Directional bias was pronounced in the vertical direction, and many brackets were bonded toward the occlusal surface. However, no statistical difference was found for the three angular measurement values (torque, angulation, and rotation) in any of the groups classified according to crowding. When the teeth were moderately crowded, the mesio-distal, bucco-lingual, and rotation measurement values were affected by the presence of the resin base. Conclusions: The characteristics of the CAD/CAM one-piece jig system were demonstrated according to the influencing factors, and the transfer accuracy was verified to be within a clinically acceptable level for the indirect bracket bonding of anterior teeth.

Rotational tolerances of a titanium abutment in the as-received condition and after screw tightening in a conical implant connection

  • Prisco, Rosario;Troiano, Giuseppe;Laino, Luigi;Zhurakivska, Khrystyna
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권6호
    • /
    • pp.343-350
    • /
    • 2021
  • PURPOSE. The success of an implant-prosthetic rehabilitation is influenced by good implant health and an excellent implant-prosthetic coupling. The stability of implant-prosthetic connection is influenced by the rotational tolerance between anti-rotational features on the implant and those on the prosthetic component. The aim of this study is to investigate the rotational tolerance of a conical connection implant system and its titanium abutment counterpart, in various conditions. MATERIAL AND METHODS. 10 preparable titanium abutments, having zero-degree angulation (MegaGen, Daegu, Korea) with an internal 5-degree conical connection, and 10 implants (MegaGen, Daegu, Korea) were used. Rotational tolerance between the connection of implant and titanium abutments was measured through the use of a tridimensional optics measuring system (Quick Scope QS250Z, Mitutoyo, Kawasaki, Japan) in the as-received condition (Time 0), after securing with a titanium screw tightening at 35 Ncm (Time 1), after tightening 4 times at 35 Ncm (Time 2), after tightening one more time at 45 Ncm (Time 3), and after tightening another 4 times at 45 Ncm (Time 4). RESULTS. The group "Time 0" had the lowest values of rotational freedom (0.22 ± 0.76 degrees), followed by the group Time 1 (0.46 ± 0.83 degrees), the group Time 2 (1.01 ± 0.20 degrees), the group Time 3 (1.30 ± 0.85 degrees), and the group Time 4 (1.49 ± 0.17 degrees). CONCLUSION. The rotational tolerance of a conical connection is low in the "as received" condition but increases with repetitive tightening and with application of a torque greater than 35 Ncm.

Evaluation of strategic uprighting of the mandibular molars using an orthodontic miniplate and a nickel-titanium reverse curve arch wire: Preliminary cephalometric study

  • Park, Jae-Hyun;Choo, HyeRan;Choi, Jin-Young;Chung, Kyu-Rhim;Kim, Seong-Hun
    • 대한치과교정학회지
    • /
    • 제51권3호
    • /
    • pp.179-188
    • /
    • 2021
  • Objective: To evaluate the overall treatment effects in terms of the amount of uprighting with changes in the sagittal and vertical positions of mandibular molars after applying an orthodontic miniplate with a nickel-titanium (NiTi) reverse curve arch wire (biocreative reverse curve [BRC] system). Methods: A total of 30 female patients (mean age, 25.99 ± 8.96 years) were treated with the BRC system (mean BRC time, 10.3 ± 4.07 months). An I-shaped C-tube miniplate (Jin Biomed) was placed at the labial aspect for the alveolar bone of the mandibular incisors. A 0.017 × 0.025-inch NiTi reverse curve arch wire was engaged at the C-tube mini-plate anteriorly and the first and second premolars and molars posteriorly in the mandibular arch. Pre- and post-BRC lateral cephalograms were analyzed. A paired t-test was used to analyze the treatment effects of BRC. Results: The mandibular second molars were intrusively uprighted successfully by the BRC system. Distal uprighting with a controlled vertical dimension was noted on the first molars when they remained engaged in the BRC and the distal ends of the arch wire were laid on the second molars. The mandibular first and second premolars showed a slight extrusion. The changes in the mandibular incisors were unremarkable, while the mandibular molar angulation improved significantly. The lower occlusal plane rotated counterclockwise (MP-LOP: 1.13° ± 2.60°). Conclusions: The BRC system can provide very effective molar uprighting without compromising the position of the mandibular anterior teeth.

요골 간부 골절 치료 후 지연 발견된 원위 척골의 전방 탈구 (Delayed Diagnosis of Volar Dislocation of the Distal Ulna after Treatment of the Radial Shaft Fracture)

  • 전숙하;이상림
    • 대한정형외과학회지
    • /
    • 제56권5호
    • /
    • pp.427-432
    • /
    • 2021
  • 원위 요척 관절의 전방 탈구 치료가 지연된 경우에는 수근부 통증과 전완의 회전 운동의 제한이 동반되어 결국 구제술이 필요한 퇴행성 관절염이 발생할 수 있다. 24세 남자가 요골 간부 골절 수술 후 통증과 회전 운동 제한으로 내원하였다. 금속판으로 고정된 요골의 간부에서 7도의 전방 각형성이 관찰되었으며 척골 두가 전방으로 탈구되어 회외전에서 결손부가 요골의 S자 절흔 전방 경계에 걸려 탈구가 지속되는 소견이 관찰되었다. 부정 유합된 요골의 교정의 절골술과 척골 두 골결손 근위부의 골을 원위 결손 부위로 이동시키는 절골술을 시행하여 원위 요척 관절이 전완의 회전에 안정적으로 정복이 유지되도록 하였다. 수술 후 19개월에 전완 회전 운동 범위와 통증이 개선된 것을 확인하였다.

흉골 골절과 동반된 외상성 흉쇄관절 전방 탈구의 치료 (Treatment of Traumatic Sternoclavicular Joint Anterior Dislocation with a Sternal Fracture)

  • 최성;신동주;황성문
    • 대한정형외과학회지
    • /
    • 제56권1호
    • /
    • pp.76-81
    • /
    • 2021
  • 흉쇄관절의 외상성 탈구는 드문 손상으로 전방 탈구가 후방 탈구에 비하여 흔하다. 후방 탈구는 종격동 구조물을 압박하여 잠재적 위험성이 있다고 잘 알려져 있지만 전방 탈구는 그러한 위험성에 대한 고려가 없었다. 전방 탈구라도 흉골 골절의 전방 각형성과 동반된 경우에 후방 탈구와 마찬가지로 종격동 압박이 발생 가능하며 그로인한 위험성이 있다. 본 저자들은 종격동 압박 증상이 있는 흉골 골절과 동반된 외상성 흉쇄관절 전방 탈구에 대하여 금속판을 이용해 수술적 치료를 시행하였고 비교적 양호한 결과를 얻었다. 이는 국내외에서 매우 드물게 보고되는 사례로 이를 문헌고찰과 함께 보고하고자 한다.