• Title/Summary/Keyword: Angular deviation

Search Result 95, Processing Time 0.027 seconds

Analysis on the Cause of Abrasion according to Deformation Types of Seaside Armor Stones in Saemangeum Seadike (새만금방조제 해측피복석의 변형유형에 따른 마모원인분석)

  • Son, Jae Gwon;Goh, Nam Young;Choi, Jin Kyu;Kim, Hak Won
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.6
    • /
    • pp.187-196
    • /
    • 2013
  • This study is focused on analyzing the deformation types of seaside armor stones based of field survey in order to establish the cause of abrasion following the deformation of seaside armor stones. 1. The deformation of seaside armor stone in saemangeum sea dike was classified as three different types: floating, deviation, and abrasion. 2. It was discovered that the stones floated to the extent of maximum 50 m, as the result of inspecting floating stones which were situated on different ten places. 3. The average number of deviation in the high ocean wave section was four times more than that in the ordinary ocean wave section, as a result of comparing the deviation number of the ordinary ocean wave section and that of the high ocean wave section for the purpose of inspecting the relation between the deviation of armor stones and the effects of ocean wave. 4. The angular shape of armor stones seen in the initial construction period has been abraded smoothly, as result of comparing of the shape change of armor stones for the purpose of inspecting abrasion state of seaside armor stones. 5. It was discovered that the abrasion of armor stone was severe in the section of many floating stones, as a result of analyzing the levels of abrasion and the cumulative sections of floating stones for the purpose of investigating the cause of abrasion.

Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions

  • Ozcan Akkal;Ismail Hakki Korkmaz;Funda Bayindir
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.4
    • /
    • pp.179-188
    • /
    • 2023
  • PURPOSE. This in vitro study aimed to evaluate the performance of digital intraoral scanners in a completely edentulous patient with angled and parallel implants. MATERIALS AND METHODS. A total of 6 implants were placed at angulations of 0°, 5°, 0°, 0°, 15°, and 0° in regions #36, #34, #32, #42, #44, and #46, respectively, in a completely edentulous mandibular polyurethane model. Then, the study model created by connecting a scan body on the implants was scanned using a model scanner, and a 3D reference model was obtained. Three different intraoral scanners were used for digital impressions (PS group, TR group, and CS group, n = 10 in each group). The distances and angles between the scan bodies in these measurement groups were measured. RESULTS. While the Primescan (PS) impression group had the highest accuracy with 38 ㎛, the values of 104 ㎛ and 171 ㎛ were obtained with Trios 4 IOSs (TR) and Carestream 3600 (CS), respectively (P = .001). The CS scanner constituted the impression group with the highest deviation in terms of accuracy. In terms of dimensional differences in the angle parameter, a statistically significant difference was revealed among the mean deviation angle values according to the scanners (P < .001). While the lowest angular deviation was obtained with the PS impression group with 0.185°, the values of 0.499° and 1.250° were obtained with TR and CS, respectively. No statistically significant difference was detected among the impression groups in terms of precision values (P > .05). CONCLUSION. A statistically significant difference was found among the three digital impression groups upon comparing the impression accuracy. Implant angulation affected the impression accuracy of the digital impression groups. The most accurate impressions in terms of both distance and angle deviation were obtained with the PS impression group.

A Study on Won Bang(員方) Supplementation and Draining Method in the 『Huangdineijing』 (『황제내경(黃帝內經)』에 나타난 원방보사(員方補瀉)에 관한 고찰(考察))

  • Kim, Jong-hyun
    • Journal of Korean Medical classics
    • /
    • v.33 no.4
    • /
    • pp.57-66
    • /
    • 2020
  • Objectives : This study aims to grasp the principle of the Won Bang supplementation and draining method as mentioned in the 『Lingshu·Guanneng』 and the 『Suwen·Bazhengshenminlun』, which have contrasting properties. Methods : The texts in each chapter were analyzed to understand the supplementation and draining principle that matches the meanings of round[won,員] and angular[bang, 方]. Especially in the case of the chapter 「Bazhengshenminlun」, a hypothesis was drawn upon the relationship between the abstract explanation of the round[won,員] and angular[bang, 方] and the actual manipulation technique. This hypothesis was tested against other texts and annotations for further discussion. Results & Conclusions : The expressions 'bang[angular, 方]' and 'won[round,員]' refer to the same meanings in both chapters, as 'to be upright' and 'to be smooth,' respectively. The difference between the two chapters is that in the 『Lingshu·Guanneng』 the standard for Won Bang is the needler's movements, while in the 『Suwen·Bazhengshenminlun』, it is the patient's breathing. Moreover, while in the former the subjects of supplementation and draining are clearly divided into healthy qi and exterior pathogenic qi, in the latter the subject of manipulation is the deficiency and excessiveness caused by deviation of the healthy qi, thus making the subject of both supplementation and draining healthy qi. Based on these findings, we can conclude that the supplementation and draining of needling is divided into two methods; separating the healthy and pathogenic qi and manipulating the deficiency and excessiveness of healthy qi within the body.

A study on the dither-stripping with dither motion sensor of a ring laser gyroscope (링레이저 자이로의 몸체진동 검출센서를 이용한 dither-stripping 연구)

  • Sim, Gyu Min;Im, Hu Jang
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.5
    • /
    • pp.63-71
    • /
    • 2003
  • In this paper we dicuss the dither-stripping methods by V-F(voltage to frequency) conversion of the output of angular velocity sensor which is for detecting the dither motion of the ring laser cavity. In this case, it is very important to evaluate the pulse-to-pulse scale factor between the ring lase output pulse and V-F output pulse, and also to compensate the zero offset of the V-F output pulse. In the case of the dither-stripping by the V-F conversion of angular velocity sensor output, there is a big angle uncertainty in the process of compensating the zero offset due to the dither noise for compensating the V-F output. By differential, the phase of the V-F output is changed. So, to compensate it, we change 90deg of the phase of angular velocity sensor output and delay half sampling time of the phase of ring laser output in advance. In this case the pulse-to-pulse scale factor can be evaluated by the standard deviation of each pulse. We can get the good result of the dither-stripping output by this angle differential method.

A Biomechanical Analysis of Lower Extremity Segment dur ing the Fouette en dehors Performed by Ballet Dancers (발레 무용수의 Fouette en dehors동작 시 하지분절에 대한 생체역학적 분석)

  • Lee, Jin;Oh, Cheong-Hwan
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.1
    • /
    • pp.43-53
    • /
    • 2012
  • The purpose of this study was to quantitatively examine the biomechanical variables of Fouette turns for expert and beginner ballet dancers and to determine the difference in the variables between the two groups. sixteen female ballet dancers participated in this study. They were divided into an expert group(age, $25.38{\pm}1.92$ years; height, $168.38{\pm}4.66$ cm; mass, $49.63{\pm}4.41$ kg) and a beginner group(age, $20.88{\pm}1.13$ years; height, $161.63{\pm}7.42$ cm; mass, $48.88{\pm}3.64$ kg) depending on their ballet experience. Descriptive data were expressed as mean ${\pm}$ standard deviation (SD) for all variables including the duration, displacement of the center of the body, velocity of the center of the body, angle of the body segments, angular velocity of the body segments, ground reaction force, lower extremity torque, muscle activity, body weight, age, and body mass. An independence t-test was conducted to determine how the following variables differed between the beginners and experts: duration, displacement of the center of the body, velocity of the center of the body, angle of the body segments, angular velocity of the body segments, ground reaction force, lower extremity torque, and muscle activity. All comparisons were made at the p<0.05 significance level. The results show that the experts scored high on the biomechanical variables, although all the variables were not significant. Significant differences were found in the angle of body segments, angular velocity of the body segments, lower extremity torque, and muscle activity(p<0.05). The findings of this study demonstrate that the experts have the required skill to make an improved Fouette turn. The findings may also help ballet dancers to learn and understand the Fouette turn.

Three-dimensional evaluation of the transfer accuracy of a bracket jig fabricated using computer-aided design and manufacturing to the anterior dentition: An in vitro study

  • Park, Jae-Hyun;Choi, Jin-Young;Kim, Seong-Hun;Kim, Su-Jung;Lee, Kee-Joon;Nelson, Gerald
    • The korean journal of orthodontics
    • /
    • v.51 no.6
    • /
    • pp.375-386
    • /
    • 2021
  • Objective: To evaluate the accuracy of a one-piece bracket jig system fabricated using computer-aided design and manufacturing (CAD/CAM) by employing three-dimensional (3D) digital superimposition. Methods: This in vitro study included 226 anterior teeth selected from 20 patients undergoing orthodontic treatment. Bracket position errors from each of the 40 arches were analyzed quantitatively via 3D digital superimposition (best-fit algorithm) of the virtual bracket and actual bracket after indirect bonding, after accounting for possible variables that may affect accuracy, such as crowding and presence of the resin base. Results: The device could transfer the bracket accurately to the desired position of the patient's dentition within a clinically acceptable range of ± 0.05 mm and 2.0° for linear and angular measurements, respectively. The average linear measurements ranged from 0.029 to 0.101 mm. Among the angular measurements, rotation values showed the least deviation and ranged from 0.396° to 0.623°. Directional bias was pronounced in the vertical direction, and many brackets were bonded toward the occlusal surface. However, no statistical difference was found for the three angular measurement values (torque, angulation, and rotation) in any of the groups classified according to crowding. When the teeth were moderately crowded, the mesio-distal, bucco-lingual, and rotation measurement values were affected by the presence of the resin base. Conclusions: The characteristics of the CAD/CAM one-piece jig system were demonstrated according to the influencing factors, and the transfer accuracy was verified to be within a clinically acceptable level for the indirect bracket bonding of anterior teeth.

A Study on the Design of a Gear Transmission Error Test Rig (기어 전달오차 측정 장비의 설계에 관한 연구)

  • Zhang, Qi;Zhang, Jing;Yan, Hou-Ling;Zhu, Qing-Wang;Xu, Zhe-zhu;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.1
    • /
    • pp.14-19
    • /
    • 2016
  • Transmission error (TE) is the most important cause of gear noise and vibration because TEs affect the changes of the force and the speed of gears. TE is usually expressed as an angular deviation, or a linear deviation measured at the pitch point and calculated at successive positions of the pinion as it goes through the meshing cycle. Accurate measurement of TE for gear transmission will provide a reasonable basis for gear design, manufacturing processes and quality control. Therefore, in order to study the accuracy of the gear transmission, stability, TE, vibration and noise after gear micro-geometry modification, a gear transmission test rig is proposed in this paper, which is based on the existing technical conditions, by using reasonable testing methods, hardware and a signal processing method. All of the details and the experience can be taken into consideration in the next upgraded test rig.

Error-immune Algorithm for Absolute Testing of Rotationally Asymmetric Surface Deviation

  • Zhang, Yanwei;Su, Dongqi;Li, Le;Sui, Yongxin;Yang, Huaijiang
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.335-340
    • /
    • 2014
  • Based on Zernike polynomial fitting, we propose an algorithm believed to be new for interferometric measurements of rotationally asymmetric surface deviation of optics. This method tests and calculates each angular surface by choosing specified rotation angles with lowest error. The entire figure can be obtained by superimposing these sub-surfaces. Simulation and experiment studies for verifying the proposed algorithm are presented. The results show that the accuracy of the proposed method is higher than single-rotation algorithm and almost comparable to the rotation-averaging algorithm with fewer rotation measurements. The new algorithm can achieve a balance between the efficiency and accuracy.

Effect of Wrist Resistance Training on Motor Control and Strength in Young Males

  • Kim, You-Sin;Kim, Dae-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.3
    • /
    • pp.309-315
    • /
    • 2014
  • The aim of the present study was to investigate the effects of 6-week wrist resistance training on wrist torque control. Nineteen subjects were randomly assigned to either the wrist training group (n=9) or the control group (n=10). The training group performed wrist exercises for six directions (flexion, extension, pronation, supination, radial deviation, and ulnar deviation) while the control group did not. Testing for the isometric torque control error, one-repetition maximum (1-RM) strength, and isokinetic maximum torque (angular velocity of $60^{\circ}/s$ wrist movements) were conducted before and after six weeks of resistance training and after every two-week interval of training. The wrist training group showed significant decreases in isometric torque control error in all six directions after the 2-week resistance training, while the control group did not show significant increase or decrease. The training group showed significant increases in the maximum strength in all six directions assessed by 1-RM strength and isokinetic strength tests after the 4-week resistance training, while the control group did not show any statistically significant changes. This study shows that motor control ability significantly improves within the first two weeks of resistance training, while the wrist strength significantly improves within the first four weeks of resistance training in wrist training group compared to the control.

Tutorial on the Principle of Borehole Deviation Survey - An Application of the Coordinate Transforms (시추공 공곡 측정의 원리 - 좌표계 변환의 응용)

  • Song, Yoonho
    • Geophysics and Geophysical Exploration
    • /
    • v.23 no.4
    • /
    • pp.243-252
    • /
    • 2020
  • To share an understanding of trajectory measurement in surveys using borehole, this tutorial summarizes the relevant mathematical principles of the borehole deviation survey based on coordinate transform. For uncased or open holes, calculations of the azimuth-deviation-tool face rotation using three-component accelerometer and magnetometer measurements are summarized. For the steel-cased holes, calculations are based on the time-derivative formula of the coordinate transform matrix; yaw-pitch-roll angles through time are mathematically determined by integrating the threecomponent angular velocity measurements from the gyroscope while also removing the Earth's rotation effect. Sensor and data fusion to increase the accuracy of borehole deviation survey is explained with an example of the method. These principles of borehole deviation surveys can be adapted for attitude estimation in air-borne surveys or for positioning in tunnels where global positioning system (GPS) signals cannot be accessed. Information on the optimization filter that must be incorporated in sensor fusion is introduced to help future research.