• Title/Summary/Keyword: Angular deviation

Search Result 95, Processing Time 0.022 seconds

Numerical Study on Fluid Flow Characteristics in Taylor Reactor using Computational Fluid Dynamics (CFD를 이용한 테일러 반응기의 유동 특성에 관한 수치적 연구)

  • Lee, Seung-Ho;Shim, Kyu Hwan;Jeon, Dong Hyup
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.1
    • /
    • pp.9-19
    • /
    • 2016
  • This study investigated the variations of Taylor flow and particle residence time in a Taylor reactor according to the changes of angular velocity and inlet velocity using computational fluid dynamics technique. The results showed that the fluid in a reactor became unstable with an increase of angular velocity. The flow moved to the regions of CCF, TVF, WVF and MWVF resulting in an increase of Reynolds number. Accordingly, the flow characteristics were different for each regions. We confirmed that the inlet velocity influences the Taylor flow. The particle residence time and standard deviation increased with an increase of angular velocity and a decrease of inlet velocity.

Implant Fixture Installation in the Anterior Mandible by Use of a Mucosa Supported Surgical Template Based on Computer Assisted Treatment Planning (컴퓨터보조 기반 점막지지 서지컬템프레이트를 이용한 하악전치부 임플란트 식립)

  • Lee, Jee-Ho;Kim, Soung-Min;Kim, Myung-Joo;Park, Jung-Min;Seo, Mi-Hyun;Myoung, Hoon;Lee, Jong-Ho;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.2
    • /
    • pp.158-165
    • /
    • 2011
  • A 73-year-old Korean female patient with a fully edentulous mandible was planned to have five implant fixtures installed in the anterior mandible for the fixed prosthesis. After 3-dimensional (3D) computed tomographic scanning was transferred to OnDemand3D$^{(R)}$ (Cybermed Co., Seoul, Korea) software program for the virtual planning, five fixtures of MK III Groovy RP implants of Branemark System$^{(R)}$ (Nobel Biocare AB Co., Goteborg, Sweden) were installed in the anterior mandible between both mental foramens using In2Guide$^{(R)}$ (CyberMed Co., Seoul, Korea) mucosa-supported surgical template with Quick Guide Kit$^{(R)}$ (Osstem Implant Co., Seoul, Korea) systems. Fixture installations were completed successfully without any complications, such as mental nerve injury, bony bleedings, fenestrations and other unexpected events. Postoperative computed tomographic scans were aligned and fused to the planned implant, then angular and linear deviations were compared with the planned virtual implants. The mean angular deviation between the planned and actual implant axes was $3.42{\pm}1.336^{\circ}$. The mean distance between the planned and actual implant at the neck area was $0.544{\pm}0.290$ mm horizontally and $0.118{\pm}0.079$ mm vertically. The average distance between the planned and actual implant at the apex area was $1.166{\pm}0.566$ mm horizontally and $0.14{\pm}0.091$ mm vertically. These results could be considered more precise and accurate than previous reports, and even our recent results. The entire procedures of this case are reported and reviewed.

Positional deviation between CBCT-based digital facebow transfer and analog facebow transfer: case series (CBCT 기반 디지털 안궁이전과 아날로그 안궁이전의 위치 편차: 증례보고)

  • Myung Hyun Park;Keunbada Son;Hwi-Gyun Ahn;Du-Hyeong Lee;So-Yeun Kim;Kyu-Bok Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.3
    • /
    • pp.176-185
    • /
    • 2023
  • Facebow transfer is essential for accurately mounting a dental cast onto a semi-adjustable articulator. The precision of traditional analog facebow transfer is influenced by both the accuracy of the equipment used and the skill level of the operator. Considering that substantial positional deviations can adversely affect the quality of a fabricated dental prosthesis; it is critical to assess the positional accuracy of casts mounted using analog facebow transfer. This case report evaluates the linear and angular deviations of the occlusal plane for maxillary casts mounted through both analog facebow transfer and cone-beam computed tomography-based methods. The findings indicate that analog facebow transfer produced a linear deviation ranging from 3 to 16 mm and an angular deviation of the occlusal plane between 5 to 7 degrees. This case report confirms that, across two patients, analog facebow transfer can result in varying degrees of positional deviation, thereby potentially leading to inaccuracies in the fabrication of dental prostheses. These results suggest that, in clinical practice, the use of analog facebow transfer may yield significant deviations during the process of mounting maxillary casts.

Relationship between chin deviation and the position and morphology of the mandible in individuals with a unilateral cleft lip and palate

  • Kim, Kyung-Seon;Son, Woo-Sung;Park, Soo-Byung;Kim, Seong-Sik;Kim, Yong-Il
    • The korean journal of orthodontics
    • /
    • v.43 no.4
    • /
    • pp.168-177
    • /
    • 2013
  • Objective: In this study, we aimed to examine the relationship between chin deviation and the positional and morphological features of the mandible and to determine the factors that contributed to chin deviation in individuals with a unilateral cleft lip and palate (UCLP). Methods: Cone-beam computed tomography (CBCT) images of 28 adults with UCLP were analyzed in this study. Segmented three-dimensional temporomandibular fossa and mandible images were reconstructed, and angular, linear, and volumetric parameters were measured. Results: For all 28 individuals, the chin was found to deviate to the cleft side by 1.59 mm. Moreover, among these 28 individuals, only 7 showed distinct (more than 4 mm) chin deviation, which was toward the cleft side. Compared to the non-cleft side, the mandibular body length, frontal ramal inclination, and vertical position of the condyle were lower and inclination of the temporomandibular fossa was steeper on the cleft side. Furthermore, the differences in inclination of the temporomandibular fossa, mandibular body length, ramus length, and condylar volume ratio (non-deviated/deviated) were positively correlated with chin deviation. Conclusions: UCLP individuals show mild chin deviation to the cleft side. Statistical differences were noted in the parameters that represented positional and morphological asymmetries of the mandible and temporomandibular fossa; however, these differences were too small to indicate clinical significance.

Data Acquisition and Analysis of a Measuring Machine for Marine Engine′s Cams (선박 엔진용 캠 전용 측정기의 데이터 취득 및 해석)

  • 강재관;이경휘
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.11
    • /
    • pp.160-166
    • /
    • 2002
  • In this paper, data acquisition and analysis of a measuring machine for marine engine's cams is discussed. A rotary encoder and linear scale of the machine to measure angular and linear displacement respectively are interfaced to the PC via encoder board with 2 channels. The design and measuring data are interpolated by cubic spline curves to compute the precision error which is defined by the maximum and minimum distances between two curves. The minimum zone fit of ISO is employed to evaluate the geometric deviation. The developed system takes only 5 minutes to measure and analyze while the CMM takes over 1 hours even with a skilled operator.

Data acquisition and analysis of an exclusive measuring machine for marine engine′s cams

  • Dong-Woo;Jae-Gwan
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.5 no.4
    • /
    • pp.21-27
    • /
    • 2004
  • In this paper, data acquisition and analysis of a measuring machine for marine engine's cams are discussed. A rotary encoder and linear scale of the machine to measure angular and linear displacement, respectively, are interfaced to the PC via an encoder board with 2 channels. The design and measuring data are interpolated by cubic spline curves to compute the precision error which is defined by the maximum and minimum distances between two curves. The minimum zone fit of ISO is employed to evaluate the geometric deviation. The developed system takes only 5 minutes to measure and analyze the precision error while the CMM takes over I hours even with a skilled operator.

A Case Study of Angular Momentum of Trunk and Lower extremity when Performing Uchimata by Posture and Voluntary Resistance Levels of Uke in Korean Judo Olympian[III] (유도 올림피언 허벅다리걸기 기술발휘 시 받기의 자세와 저항수준에 따른 몸통과 하지의 각운동량 분석 사례연구[III])

  • Kim, Eui-hwan;Kim, Sung-sup;Chung, Chae-Wook
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.4
    • /
    • pp.191-203
    • /
    • 2005
  • It was to study a following research of "A Kinematical Traits Analysis when Performing Uchimata(inner thigh reaping throw) by Posture and Voluntary Resistance Levels(VRL) of Uke in Judo[1]" and. "A Case Study of Center of Gravity(COG) when Performing Uchimata(inner thigh reaping throw) by Posture and Voluntary Resistance Levels(VRL) of Uke in Judo[II]". The purpose of this study was to analyze an angular momentum of trunk and lower extremity when performing uchimata by two postures and voluntary resistance levels(VRL) of uke(reciver) in Judo. The subjects, who were one male judoka(YH) for 1992 Barcelona Olympic Games Olympian(silver medalist), was filmed on two S-VHS 16mm video cameras(60fields/sec.) through 3-dimensional motion analysis methods, that postures of uke were shizenhontai (straight natural posture:NP) and jigohontai (straight defensive posture:DP), VRL of uke were 0% and 100%, respectively. The variables were angular momentum of trunk, lower extremity of attacking leg and supporting leg of tori(the thrower). The data of this study collection were digitized by SIMI Motion Program computed the mean values and the standard deviation calculated for each variables. When performing uchimata according to each posture and VRL of uke and classifying. From the data analysis and discussion, the conclusions were as follows : Angular momentum of trunk when performing uchimata was showed the largest among another angular momenta, and the posture displayed more different than resistant of uke(reciver), but the pattern similar in judo. Angular momentum of trunk of X axis was the largest and Y, Z axis order. Angular momentum of attacking the thigh-leg when performing uchimata was showed the largest among another angular momenta, and the posture displayed more different than resistant of uke(reciver), X axis and Y axis similar, but angular momentum of Z axis of thigh-leg the largest, in kake(application) event in 0% resistance of DP than other variables. Angular momentum in X,Y axis of attacking the lower-leg when performing uchimata was showed that the resistance level displayed more different than posture, but Z axis the largest, in kake(E3) phase in 0% resistance of DP than other variables as same thigh-leg, and the largest from tsukuri(set-up:E2) to kake(E3) phase. X and Z axis Angular momentum of supporting the thigh-leg were similar, regardless of posture and resistance of uke, but Y axis was resistance level. Angular momentum of supporting the thigh-leg was showed the largest in X axis, increased from EO event to E2, and decreased in E3, and angular momenta of Y, X axis were showed the largest in kuzushi(balance breaking) phase when performing uchimata. Angular momentum of supporting the lower leg were similar pattern, regardless of posture and resistance of uke, in Y axis, resistance displayed more difficult the position in NP, and showed opposite angular momentum in tsukuri phase. In conclusion, angular momentum of trunk when performing uchimata was showed the largest, and pattern was similar, regardless of posture than resistant of uke(reciver), magnitude and direction were different each other, and uchimata was Ashi -waza(foot and leg techniques) division but important of trunk action.

Effect of internal angles between limbs of cross plan shaped tall building under wind load

  • Kumar, Debasish;Dalui, Sujit Kumar
    • Wind and Structures
    • /
    • v.24 no.2
    • /
    • pp.95-118
    • /
    • 2017
  • The present study revealed comparison the pressure distribution on the surfaces of regular cross plan shaped building with angular cross plan shaped building which is being transformed from basic cross plan shaped building through the variation of internal angles between limbs by $15^{\circ}$ for various wind incidence angle from $0^{\circ}$ to $180^{\circ}$ at an interval of $30^{\circ}$. In order to maintain the area same the limbs sizes are slightly increased accordingly. Numerical analysis has been carried out to generate similar nature of flow condition as per IS: 875 (Part -III):1987 (a mean wind velocity of 10 m/s) by using computational fluid dynamics (CFD) with help of ANSYS CFX ($k-{\varepsilon}$ model). The variation of mean pressure coefficients, pressure distribution over the surface, flow pattern and force coefficient are evaluated for each cases and represented graphically to understand extent of nonconformities due to such angular modifications in plan. Finally regular cross shaped building results are compared with wind tunnel results obtained from similar '+' shaped building study with similar flow condition. Reduction in along wind force coefficients for angular crossed shaped building, observed for various skew angles leads to develop lesser along wind force on building compared to regular crossed shaped building and square plan shaped building. Interference effect within the internal faces are observed in particular faces of building for both cases, considerably. Significant deviation is noticed in wind induced responses for angular cross building compared to regular cross shaped building for different direction wind flow.

A Case of New Surgical Correction of Angular Limb Deformities Using One Screw Implant & Periosteal Transection in a Thoroughbred Foal (Thoroughbred 망아지에서 단일나사못 장착 및 골막박리를 이용한 지세교정술)

  • Yang, Jae-Hyuk;Lim, Yoon-Kyu
    • Journal of Veterinary Clinics
    • /
    • v.29 no.2
    • /
    • pp.177-180
    • /
    • 2012
  • Angular limb deformities (ALD) are common in foals. A 30-days-old Thoroughbred foal was presented for the evaluation of severe ALD of the both forelimbs. On radiographic examination, both distal radiuses were diagnosed as valgus angular limb deformities. But the degree of deviation of right forelimb was so severe that we tried to correct one after the other. We tried new surgical correction method combination of one screw implant on medial aspect for growth retardation and periosteal transection on lateral aspect of the right forelimb. 40 days later, successfully corrected and then removed the screw. After the right forelimb correction, the periosteal transection on left forelimb was performed. We did the inhalation anesthesia using isoflurane. There were no complications such as fibrosis over the screw heads, and overcorrection that produces an opposing deformity identified. These results suggest that combination of one screw implant and periosteal transection technique is able to be a safe and effective method to correct severe ALD in the foal.

A LATERAL CEPHALOMETRIC ANALYSIS OF MIDFACE FOCUSING ON ZYGOMATIC BONE IN KOREAN ADULTS (정상 한국인 성인 남녀에서 협골을 중심으로 한 중안모의 측모 두부방사선 규격사진 분석법)

  • Lee, Eui-Hoon;Chung, In-Kyo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.4
    • /
    • pp.353-359
    • /
    • 1999
  • Purpose : A new method of lateral cephalometric analysis for midface, focusing on zygomatic bone, was created in this study, and measured in Korean adults. The purposes of this study are understanding about new approach for midfacial depression, especially zygomatic bone, and using to make adequate diagnosis and treatment plan. Materials and methods : In this study, esthetic Korean adults, 25 males and 25 females who were between $0^{\circ}$ and $4^{\circ}$ in ${\angle}ANB$, and between 62% and 70% in P/A facial height ratio, and had normal overbite and overjet, were used. Orbitale(Or) and Soft tissue orbitale(Or') were used for indicators of anteroposterior position of zygomatic area. And, mean value and standard deviation of linear and angular measurements, and ratio about each linear measurements, were obtained. then, standard deviation diagram - wiggle diagram - was made for visualization of results. Results : Mean values, standard deviations and ranges of 19 measurements were obtained, and among them, 5 linear measurements that had large standard deviation were excluded and the others were used for making standard deviation diagram. In standard deviation diagram, the following results were obtained. 1. If the measurements are located on more left side of mean-value-vertical -line, the potential of midfacial hypoplasia are stronger, especially zygomatic area. 2. If the measurements are located on more right side of mean-value-vertical-line, the potential of midfacial hypoplasia are decreased. Conclusion : This study presented a new method of lateral cephalometric analysis focusing on zygomatic bone in Korean adults. We expect that the results of this study can be used as parameter when clinicians make decisions about diagnosis and treatment plan for rehabilitation of esthetics and function. But, it is necessary to prove its usefulness, and to further evaluate the results.

  • PDF