• Title/Summary/Keyword: Angle measurements

Search Result 1,321, Processing Time 0.03 seconds

Development of a Ground Speed Monitoring System for Aerial Application (항공방제용 지면속도 감시장치의 개발)

  • 구영모;알빈워맥
    • Journal of Biosystems Engineering
    • /
    • v.25 no.3
    • /
    • pp.233-240
    • /
    • 2000
  • A commercially available Doppler radar was modified and evaluated for on-board monitoring of ground speed. The radar output was corrected for pitch angle of aircraft based on the output of an electrolytic tilt sensor. The effects of aircraft speed, height and mounting angle on error in the ground speed were evaluated. The speed error decreased with an increase of the mounting angle since the radar contact angle with respect to the ground approached to the mounting angle. The error increased with an increase of the nominal aircraft speed. The altitude insignificantly affected the speed error. The Doppler radar provided acceptable percent errors within 5% in most measurements. The error can be reduced within ${\pm}$1.5% by increasing the mounting angle ($43^{\circ}$). The error of -3.8% at the mounting angle of $29^{\circ}$could be reduced by adjusting the mounting angle with respect to the radar contact angle.

  • PDF

Comparison of cone-beam computed tomography cephalometric measurements using a midsagittal projection and conventional two-dimensional cephalometric measurements

  • Jung, Pil-Kyo;Lee, Gung-Chol;Moon, Cheol-Hyun
    • The korean journal of orthodontics
    • /
    • v.45 no.6
    • /
    • pp.282-288
    • /
    • 2015
  • Objective: This study investigated whether it is possible to use a two-dimensional (2D) standard in three-dimensional (3D) analysis, by comparing the angles and lengths measured from a midsagittal projection in 3D cone-beam computed tomography (CBCT) with those measured by 2D lateral cephalometric radiography (LCR). Methods: Fifty patients who underwent both LCR and CBCT were selected as subjects. CBCT was reoriented in 3 different methods and the measuring-points were projected onto the midsagittal plane. Twelve angle values and 8 length values were measured on both LCR and CBCT and compared. Results: Repeated measures analysis of the variance revealed statistically significant differences in 7 angular and 5 linear measurements among LCR and 3 types of CBCT (p < 0.05). Of these 12 measurements, multiple comparisons showed that 6 measurements (ANB, AB to FH, IMPA, FMA, Co-Gn, Go-Me) were not significantly different in pairwise comparisons. LCR was significantly different from 3 types of CBCT in 3 angular (SN to FH, interincisal angle, FMIA) and 2 linear (S-Go, Co-ANS) measurements. The CBCT method was similar for all measurements, except for 1 linear measurement, i.e., S-N. However, the disparity between the mean values for all parameters was within the range of clinical measurement error. Conclusions: 3D-CBCT analysis, using midsagittal projection, is a useful method in which the 2D-LCR normative values can be used. Although the measurements changed with reorientation, these changes were not clinically significant.

Effect of Native Oxide Layer on the Water Contact Angle to Determine the Surface Polarity of SiC Single Crystals (접촉각 측정방법을 이용한 SiC 단결정의 극성표면 판별에 있어 자연산화막의 영향)

  • Park, Jin Yong;Kim, Jung Gon;Kim, Dae Sung;Yoo, Woo Sik;Lee, Won Jae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.3
    • /
    • pp.245-248
    • /
    • 2020
  • The wettability of silicon carbide (SiC) crystal, which has 6H-SiC and 4H-SiC regions prepared using the physical vapor transport (PVT) method, is quantitatively analyzed using dispensed deionized (DI) water droplets. Regardless of the polytypes in SiC, the average of five contact angle measurements showed a difference of about 6° between the Si-face and C-face. The contact angle on the Si-face (C-face) is measured after the removal of the native oxide using BOE (6:1), and revealed a significant decrease of the contact angle from 74.9° (68.4°) to 47.7° (49.3°) and from 75.8° (70.2°) to 51.6° (49.5°) for the 4H-SiC and 6H-SiC regions, respectively. The contact angle of the Si-face recovered over time during room temperature oxidation in air; in contrast, that of the C-face did not recover to the initial value. This study shows that the contact angle is very sensitive to SiC surface polarity, specific surface conditions, and process time. Contact angle measurements are expected to be a rapid way of determining the surface polarity and wettability of SiC crystals.

Intra-Rater and Inter-Rater Reliability of Various Forward Head Posture Measurements

  • Yoo, Won-Gyu;Kim, Min-Hee;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.12 no.4
    • /
    • pp.41-47
    • /
    • 2005
  • The purpose of this study was to determine the intra-rater and inter-rater reliability of various forward head posture measurements. Ten healthy adults (age, $20.4{\pm}2.2$ yrs; height, $164.0{\pm}5.5$ cm; weight, $58.7{\pm}7.3$ kg) participated in the study. They were free of injury and neurologic deficits in the upper extremities and neck at the time of testing. The subjects were asked to perform head forward posture by under the guidance of physical therapists. Markers were placed on the C7 spinous process, mastoid process, tragus of the ear, outer canthus, and forehead. Measurement 1 for forward head posture assessment was measured as the angle between the horizontal line through C7 and the line connecting the C7 spinous process with the tragus of the ear. Measurement 2 was measured as the angle between the C7 spinous process, the mastoid process and the outer canthus. Measurement 3 was measured as two kinds of angles the HT (head tilt) angle is between the line from the midpoint of forehead to the tragus line and Y-axis at the tragus point. The NF (neck flexion) angle is between the line from the tragus to the C7 line and the Y-axis at the C7. Intra-rater, inter-rater reliability and coefficient of variation was assessed by comparing the measured values from three kinds of measurements of forward head posture. The intra-rater reliability was indicated by intraclass correlation coefficients [ICC(1,1)] and inter-rater reliability was shown by intraclass correlation coefficients [ICC(3,k)]. The results of study were as follows: ICC(1,1) values for intra-rater reliability of three measurements were in the 'excellent' category. ICC(3,k) values for inter-rater reliability of three measurements were also in the 'excellent' category. The coefficient of variation of method 2 had a lower value than method 1 and method 3. This data means that the measured value of method 2 was less scattered. Further research is needed to determine whether the validity of all measurements is revealed in the 'excellent' category.

  • PDF

STANDARDS FOR KOREAN ADULT FACIAL RELATIONSHIPS BY VARIOUS ROENTGENO - CEPHALOMETRIC ANALYSIS (두부(頭部)X선(線) 규격(規格) 측모사진계측(側貌寫眞計測)에 의한 한국인(韓國人) 성년남녀(成年男女)의 표준치(標準値)에 관(關)한 연구(硏究))

  • Lee, Chong Taik
    • The korean journal of orthodontics
    • /
    • v.18 no.2
    • /
    • pp.459-474
    • /
    • 1988
  • A study was made of a method of rational assessment on the roentgeno-cephalogram in orthodontic practice. Fifty eight measurements were analyzed on the roentgeno-cephalograms of 50 male and 50 female Korean adults with the acceptable profile and the normal occlusion. The means and standard deviations of measurements were studied in male and female groups by various analytic methods, and the sex difference was examined statistically. The obtained data were compared with those of the Japanese and American standards by useing a Japanese adults standard polygon chart reported by lizuka and Ishikawa. Amongs of 58 measurements, 14 have been selected as statistically significant and clinically useful, and used to make a Korean adult standard polygon chart. The results obtained were as follows: 1. Standards for cphalometric analysis in Korean adults were obtained, and the polygon chart and cephalometric profilogram were also made by using the standards in order to apply to a clinical diagnosis. 2. The sex difference was recognized in linear measurements, but not in angular measurments. 3. In comparison with the American standards from Downs and Graber, the Korean showed significant differences in angle of convexity, mandibular plane angle, Y-axis angle, interincisal angle and lower incisor to mandibular plane angle. Thus, the Korean showed a more retruded chin position, convex facial type, than white people. 4. In comparison with the Japanese standards from Iizuka and Ishikawa, the Korean showed a significant similarity with the Japanese, especially in females. 5. Upper incisor to Huxely line angle, established as a new measurement, proved to be paralell to X-Y axis angle.

  • PDF

Study on Sleeve Patterns of Men's Jackets from 17C to 19C (17세기$\sim$19세기 남성 재킷류의 소매패턴 연구)

  • Park, Sang-Hee;Choi, Jeong-Wook
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.10 no.2
    • /
    • pp.105-115
    • /
    • 2008
  • Men's outer wear, such as jackets and coats appeared since the 16th century. They have been changed from doublets, coats, justaucorps, tail-coats, frock coats and morning coats to contemporary men's suits. Since the early 17th century, sleeve patterns of men's outer jackets had been mostly two-pieces close fitted patterns. The purpose of this article is to compare sleeve patterns of various jackets, which appear in various historic costume books. Armhole measurements, sleeve head measurements, amounts of ease, armhole depths, armhole widths, crown heights, sleeve width and sleeve angle had been compared to find out the differences among patterns of different times and styles. Coming to the present, the difference between top sleeve and under sleeve became more obvious, and the sleeve angle became less curvy. Another interesting point is that there had been considerable amounts of ease, which is the difference between sleeve head measurements and corresponding armhole measurements. It is because the sleeve has been attached to the armhole not by seam but by string. It is believed that the present sleeves have more natural curve and shape compared to the past.

  • PDF

Effect of Spray Angle of Water Mist Nozzle on Temperature Field of Compartment Fire (물분무노즐의 분사각이 화재실 내부의 온도장에 미치는 영향)

  • Kim, Sung-Chan;Ryou, Hong-Sun;Park, Hyun-Tae;Bang, Ki-Young
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1703-1708
    • /
    • 2003
  • The present study investigates the effect of injection angle of water mist on fire suppression characteristics by numerical simulation. In order to validate the temperature field by numerical simulation, the predicted results are compared with experimental data. It shows that the temperature difference between measurements and predictions are within $10^{\circ}C$ Numerical simulations of fire suppression are performed for 4 different injection angle($60^{\circ}$, $90^{\circ}$, $120^{\circ}$, and $180^{\circ}$). The grobal mean temperature over the fire compartment decrease with increasing of spray angle. The result shows that the heat transfer between droplets and gas phase are enhaced with the increasing of spray angle. Near the fire source, temperature field by the wide spray angle is slightly higher than that of narrow injection angle because of direct cooling of fire source.

  • PDF

Effect of Spray Angle of Water Mist Nozzle on Temperature Field of Compartment Fire (물분무노즐의 분사각이 화재실 내부의 온도장에 미치는 영향)

  • 김성찬;유홍선;박현태;방기영
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.2
    • /
    • pp.28-33
    • /
    • 2003
  • The present study investigates the effect of injection angle of water mist on fire suppression characteristics by numerical simulation. In order to validate the temperature field by numerical simulation, the predicted results are compared with experimental data. It shows that the temperature difference between measurements and predictions are within $10^{\circ}C$. Numerical simulations of fire suppression are performed for 4 different injection angle($60^{\circ}$, $90^{\circ}$, $^120{\circ}$, and $180^{\circ}$). The global mean temperature over the fire compartment decrease with increasing of spray angle. The result shows that the heat transfer between droplets and gas phase are enhanced with the increasing of spray angle. Near the fire source, temperature field by the wide spray angle is slightly higher than that of narrow injection angle because of direct cooling of fire source.

The study of correlations between clinical balance scales and balance performance monitor parameters in patients with adolescent idiopathic scoliosis (청소년기 특발성 척추측만증 환자의 임상적 균형 평가지수와 균형 수행 모니터 측정값의 상관성 연구)

  • Shin, Seung-Sub
    • PNF and Movement
    • /
    • v.8 no.3
    • /
    • pp.39-47
    • /
    • 2010
  • Purpose : The purpose of this study was to investigate the correlations between clinical balance scales and Balance Performance Monitor parameters in patient with adolescent idiopathic scoliosis (AIS). Methods : Twenty AIS subjects (age, $14.26{\pm}1.93yrs$; height, $160.56{\pm}7.98cm$; weight, $47.54{\pm}6.94kg$)were participated in this study. Postural sway(mean balance, sway angle, sway area, sway path, maximal sway velocity) were were evaluated by balance performance monitor. Measurements for clinical balance scales were Functional reach test (both side), the Lateral reach test (both side) and One leg standing test (both legs). Results : The results were as follows. There were positive strong correlation between major curve direction and left-right sway angle, sway path, maximal sway velocity. There were negative strong correlation between the functional reach and left-right sway angle, sway area, sway path, maximal sway velocity. And the lateral reach were also showed negative strong correlation parameters of balance performance monitor. One leg standing were negatively correlated with left-right sway angle, sway path, maximal sway velocity. Conclusion : The clinical balance scales will be useful tools for balance measurements, and basic tools for clinical setting for patient with AIS.

  • PDF

Cone-Beam Computed Tomographic Assessment of Temporomandibular Joint Morphology in Patients with Temporomandibular Joint Disc Displacement and in Healthy Subjects: A Pilot Study

  • Choi, Hang-Moon;Park, Moon-Soo
    • Journal of Oral Medicine and Pain
    • /
    • v.41 no.2
    • /
    • pp.41-47
    • /
    • 2016
  • Purpose: The purpose of this study was to analyze the size and morphology of mandibular condyle and mandibular fossa between temporomandibular joint (TMJ) disc displacement (DD) patients and healthy subjects using cone-beam computed tomography (CBCT). Methods: Twenty healthy subjects and twenty TMJ DD patients participated in this study respectively. We made five measurements in mandibular condyle (medio-lateral dimension, antero-posterior dimension, condyle height, intercondylar distance and intercondylar angle) and two measurements in mandibular fossa (mandibular fossa depth and articular eminence angle) using CBCT image. Results: There was no difference between two groups in medio-lateral dimension. In case of antero-posterior dimension, average of healthy controls was larger than that of TMJ DD patients, but that was not significant statistically. There were no significant differences between two groups in condyle height. Comparing intercondylar distance and intercondylar angle between two groups, there was no significant difference between two groups. In comparison of mandibular fossa depth and articular eminence angle, there was no significant difference between two groups. Conclusions: We couldn't find any definite relationship between TMJ morphology and TMJ DD.