• 제목/요약/키워드: Angle beam method

검색결과 466건 처리시간 0.03초

Evaluation of Articular Eminence Morphology in Patients with Spontaneous Temporomandibular Joint Dislocation Using Cone Beam Computed Tomography

  • Kim, Ji Hoo;Park, Hyun-Jeong;Seo, Yo-Seob;Ryu, Ji-Won;Ahn, Jong-Mo
    • Journal of Oral Medicine and Pain
    • /
    • 제47권1호
    • /
    • pp.27-37
    • /
    • 2022
  • Purpose: This study aimed to broaden our understanding of the predisposing factor and treatment of dislocation by analyzing and evaluating the morphology of the articular eminence (AE) in subjects with temporomandibular joint (TMJ) dislocation using cone beam computed tomography (CBCT). Methods: The subjects were divided into two groups: dislocation (31 subjects) and control (32 subjects). CBCT was used to examine 126 TMJs in 63 subjects (26 males, 37 females). The height, width, and posterior slope of the AE were measured in the parasagittal plane. The posterior slope was measured using the "top-roof line angle (TR angle)" method and the "best-fit line angle (BF angle)" method. The AE on the left side (AEL) and the AE on the right side (AER) of the subjects in the dislocation group were separately analyzed and compared with the control group after taking measurements. The average value of both sides was used when comparing with subjects with bilateral dislocation. Results: Dislocations were more frequent in females (67.7%) than in males (32.3%). The dislocation group showed a gentler TR angle than the control group in the AER and in the average of AE on the both sides (AEB). The same group also showed a wider AE in the AEL and the AER (p<0.05). In subjects with unilateral dislocation, the width of the AE with dislocation was narrower and the TR angle and BF angle was steeper than the other side without dislocation (p<0.05). Conclusions: In subjects with unilateral TMJ dislocation, the posterior slope of the AE is steeper, and the width is narrower at the site of dislocation compared to the site without dislocation. However, in subjects with bilateral TMJ dislocation, AEB were wider, and the mean value of the posterior slope of AEB was gentler than that of the control group.

Homeotropic Alignment Effect of a Nematic Liquid Crystal on Oblique Deposited SiOx Thin-film with e-beam Evaporation

  • Choi, Dai-Seub
    • Transactions on Electrical and Electronic Materials
    • /
    • 제8권6호
    • /
    • pp.274-277
    • /
    • 2007
  • In this study, liquid crystal(LC) aligning capabilities for homeotropic alignment on the $SiO_x$ thin film by electron beam evaporation method were investigated. Also, the control of pretilt angles and thermal stabilities of the nematic liquid crystal(NLC) treated on $SiO_x$ thin film were investigated. A high pretilt angle of about $86.5^{\circ}$ was obtained, and also the suitable pretilt angle of the NLC on the $SiO_x$ thin film at $10{\sim}50nm$ thickness with e-beam evaporation can be achieved. The uniform LC alignment and good thermal stabilities on the $SiO_x$ thin film surfaces with electron beam evaporation can be achieved. It is considered that the LC alignment on the $SiO_x$ thin film by electron beam evaporation is attributed to elastic interaction between LC molecules and micro-grooves at the $SiO_x$ thin film surface created by evaporation.

LC Aligning Capabilities of a Nematic Liquid Crystal on Homeotropic Polyimide Surface by New Ion-beam Irradiation

  • Ok, Chul-Ho;Kang, Dong-Hun;Lee, Kang-Min;Han, Jin-Woo;Kim, Byoung-Yong;Oh, Byeong-Yun;Kim, Young-Hwan;Hwang, Jeong-Yeon;Lee, Sang-Keuk;Han, Jeong-Min;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제8권6호
    • /
    • pp.265-267
    • /
    • 2007
  • The liquid crystal(LC) aligning capabilities of a nematic liquid crystal(NLC) on a homeotropic polyimide(PI) surface using a new ion-beam method were studied. Exposure ion-beam of $45^{\circ}$ incidence angle shows a good LC alignment of the NLC on the homeotropic PI surface. Also, on the homeotropic PI surface, the tilt angle of the NLC by exposure ion-beam of $45^{\circ}$ incidence angle had a tendency to decrease as increased ion-beam energy density. And, on the homeotropic PI surface, the alignment character of the NLC with respect to ion-beam energy was good at 1500 eV. And we achieved satisfactory result for EO character.

GafChromic RTQA Film을 이용한 광역학적 치료용 레이저의 선질 측정 (GafChromic RTQA Film Dosimetry for Laser Beam with Photodynamic Therapy)

  • 이병구;임현수;네클라 커나르
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권2호
    • /
    • pp.73-79
    • /
    • 2013
  • Purpose: The purposes of this study were to measure the dose distribution of Photodynamic therapy(PDT) laser with 635 nm wavelength using GafChromic film. Method & Result: We made each output 300 J by changing mW and sec using the laser beam radiation mode such as C.W(Continuous Wave) mode, Pulse mode and Burst Pulse mode and measured the does at 0 mm and 5 mm of distance from optic fiber catheter end to the film, and at 5 mm distance by changing the angle of the end of the optic fiber catheter as $0^{\circ}$ and $0.5^{\circ}$. The radiated film was scanned and OD(Optical Density) was compared. And two-dimensional isodose curves were obtained and the consistency of shapes was compared. It was confirmed that there was consistency between optic density and the dose radiated on the film when we radiated GafChromic film by changing distance and angle of 300 J output in each radiation mode coordinating mW and sec. Conclusion: In this study, we could identify the stability according to changes in laser beam modes, changes in output according to distance, changes in uniformity according to angle, and beam profiles using GafChromic film, and we could also get two-dimensional isodose curve. It was found that small change in the distance and angle that is made when optic fiber catheter was contacted on the treatment area did not make big effects on the output of beam and the uniformity of dose, and it was also found that GafChromic film could be utilized for the purpose of QA of PDT laser beam.

이온빔 조사 각도에 따른 액정 배향 특성 연구 (Investigation of LC Alignment characteristic by Controlling Ion-beam Irradiation angles)

  • 박홍규;오병윤;김영환;김병용;한진우;전지연;한정민;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 및 기술 세미나 논문집 디스플레이 광소자
    • /
    • pp.43-43
    • /
    • 2008
  • Recently, it is widely studied to liquid crystal (LC) alignment using ion-beam exposure. Because conventional rubbing method has some problems such as defects from dust and electrostatic charges and rubbing scratch during rubbing process. Moreover rubbing method needs cleaning process to remove these defects. Therefore rubbing-free techniques like ion-beam method are strongly required. We studied LC alignment by controlling ion-beam irradiation angles and electro-optical (EO) characteristics of twisted nematic LC on the polyimide surface. In this experiment, a good uniform alignment of the nematic liquid crystal (NLC) with the ion-beam exposure on the polyimide (PI) surface was observed. We also achieved low pretilt angle as function of ion-beam irradiation angles. X-ray photoelectron spectroscopic (XPS) analysis provided chemical evidence for LC alignment by controlling ion-beam irradiation angles. In addition, it can be achieved the good EO properties of the ion-beam-aligned twisted nematic liquid crystal display (TN-LCD) on PI surface. Some other experiments results and discussion will be included in the presentation.

  • PDF

이온빔처리된 고분자막을 이용한 TN 셀의 전기광학특성 (Electro-optical property of twisted nematic liquid crystal cells with ion-beam irradiated polymer surface)

  • 김대현;옥철호;박홍규;김병용;황정연;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.338-338
    • /
    • 2009
  • To date, rubbing has been widely used to align LC molecules uniformly. Although rubbing can be simple, it has fundamental problems such as the generation of defects by dust and static electricity, and difficulty in achieving a uniform LC alignment on a large substrate. Therefore, noncontact alignment has been investigated. Ion beam induced alignment method, which provides controllability, nonstop process, and high resolution display. We investigated the high pretilt angle effects on electro-optical properties of ion beam (IB)-irradiated liquid crystal cells. on a blended polymer surface. High pretilt angle of liquid crystals IB-irradiated on a blended polymer surface including such as 5% and 10% of homeotropic polymer contents can' be achieved. The threshold voltages of IB-irradiated twisted nematic (TN) cells on a blended polymer surface decrease with increasing the pretilt angle. Also, the rising time of IB-irradiated TN cells decreases with increasing the pretilt angle. However the decay time of IB-irradiated TN cells increases with increasing the pretilt angle. Consequently, the electro-optical properties of IB-irradiated TN cells depend strongly on the pretilt angle in a blended polymer surface.

  • PDF

복합재 회전 외팔보의 면외방향 굽힘진동 해석 (Flapwise Bending Vibration Analysis of Rotating Composite Cantilever Beams)

  • 이승현;신상하;유홍희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.887-892
    • /
    • 2003
  • A modeling method for the modal analysis of a rotating composite beam is presented in this paper. Linear differential equations of motion are derived by using the assumed mode method. For the modeling, hybrid deformation variables are employed and approximated to derive the equations of motion Symmetrical laminated layers are considered for the composite beam. The effects of the dimensionless angular velocity, the hub radius and the fiber orientation angle parameter on the variations of modal characteristics are investigated.

  • PDF

산업체 적용을 위한 초음파 검사 기술 개발에 관한 연구 (A Study on Technical Development of Ultrasonic Test for Application of Industrial Fields)

  • 이원;윤인식
    • 한국정밀공학회지
    • /
    • 제14권8호
    • /
    • pp.49-56
    • /
    • 1997
  • In recent years, ultrasonic technics has been widely applied to industrial fields and its application range has been expanded as a result of continuous research and development. This paper is concerned with development of post-processor program for ultrasonic test and two-axis automatic ultrasonic system for application of industrial fields. Test results of ultrasonic test post-processor program and two-axis auto- matic ultrasonic system have a good agreement with results of ultrasonic evaluation for defect detection in industrial fields. Therefore we think that the developed ultrasonic test post-processor program and two- axis automatic ultrasonic system in this work is very useful for application of industrial fields.

  • PDF

DLC 박막을 이용한 액정 배향 효과 (Liquid Crystal Alignment Effects using a DLC Thin Film)

  • 조용민;황정연;서대식;노순준;이대규;백홍구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.346-349
    • /
    • 2001
  • We studied the nematic liquid crystal (NLC) aligning capabilities using the new alignment material of diamond like carbon (DLC) thin film. A high pretilt angle of about $4^{\circ}$ was measured by ion beam(IB) exposure on the DLC thin film surface. A good LC alignment was observed by the IB alignment method on the DLC thin film surface at annealing temperature of $200^{\circ}C$, and the alignment defect of the NLC was observed above annealing temperature of $220^{\circ}C$. Consequently, the high NLC pretilt angle and the good thermal stability of LC alignment can be achieved by the IB alignment method on the DLC thin film surface.

  • PDF

바이어스 조건하에서 증착한 a-C:H 박막을 이용한 액정배향 효과 (LC Alignment Effects using a-C:H Thin Film as Working Gas at Bias Condition)

  • 황정연;조용민;서대식;노순준;백홍구
    • 한국전기전자재료학회논문지
    • /
    • 제16권11호
    • /
    • pp.1019-1022
    • /
    • 2003
  • We studied the nematic liquid crystal (NLC) aligning capabilities using the new alignment material of a-C:H thin film as working gas at 30W rf bias condition. A high pretilt angle of about 5$^{\circ}$ by ion beam(IB) exposure on the a-C:H thin film surface was measured. A good LC alignment by the IB alignment method on the a-C:H thin film surface was observed at annealing temperature of 250$^{\circ}C$, and the alignment defect of the NLC was observed above annealing temperature of 300$^{\circ}C$. Consequently, the high LC pretilt angle and the good thermal stability of LC alignment by the IB alignment method on the a-C:H thin film surface as working gas at 30W rf bias condition can be achieved.