• Title/Summary/Keyword: Angle Changes

Search Result 1,679, Processing Time 0.028 seconds

Single Incision Flexible Endoscopic Cholecystectomy in Dogs : Feasibility Study (개에서 단일 통로 유연 내시경 담낭 절제술 : 유용성 연구)

  • Lee, So-Yeon;Shin, Beom-Jun;Jeong, Seong-Mok
    • Journal of Veterinary Clinics
    • /
    • v.28 no.6
    • /
    • pp.555-561
    • /
    • 2011
  • Laparoscopic surgery is a well-established alternative to open surgery across disciplines. However, in veterinary medicine, laparoscopic surgery in dogs was rarely reported because of small abdominal size for multiple ports insertion. The concept of single-incision laparoscopic surgery (SILS) is to perform the entire laparoscopic operation through a single incision rather than conventional multiple small skin incisions. Indirect evidence of potential benefits of SILS, decreases operative morbidity related to reduction in port size, already exists. Therefore, this study was performed to evaluate the safety and feasibility of the modified form of SILS using flexible endoscope in Cholecystectomy before clinical adoption. A 2 cm single periumbilical incision was performed, and flexible endoscope was introduced into the abdominal cavity. A laparoscopic grasper was inserted into the abdominal cavity for the traction of gall bladder. Cystic duct and artery were ligated by 5 mm Hem-o-lok$^{(R)}$. Then, gall bladder was dissected and resected from the liver with 5 mm Autonomy Laparo-Angle Maryland dissector and endoscopic needle knife. Resected gall bladder was wrapped by using specimen pouch and was retrieved through abdominal incision from the cavity. All three gall bladders were successfully removed. Hematological changes were not observed during examination periods. No leakage sign was identified at necropsy. The flexible endoscope, as distinct from conventional rigid laparoscope, allows the visualization from various angles and the wide range of motion, result in less crowding.

Design of Discriminant Function for White and Yellow Coating with Multi-dimensional Color Vectors (다차원 컬러벡터 기반 백태 및 황태 분류 판별함수 설계)

  • Lee, Jeon;Choi, Eun-Ji;Ryu, Hyun-Hee;Lee, Hae-Jung;Lee, Yu-Jung;Park, Kyung-Mo;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.2 s.20
    • /
    • pp.47-52
    • /
    • 2007
  • In Oriental medicine, the status of tongue is the important indicator to diagnose one's health, because it represents physiological and clinicopathological changes of inner parts of the body. The method of tongue diagnosis is not only convenient but also non-invasive, therefore, tongue diagnosis is one of the most widely used in Oriental medicine. But tongue diagnosis is affected by examination circumstances a lot. It depends on a light source, degrees of an angle, doctor's condition and so on. So it is not easy to make an objective and standardized tongue diagnosis. As part of way to solve this problem, in this study, we tried to design a discriminant function for white and yellow coating with multi-dimensional color vectors. There were 62 subjects involved in this study, among them 48 subjects diagnosed as white-coated tongue and 14 subjects diagnosed as yellow-coated tongue by oriental doctors. And their tongue images were acquired by a well-made Digital Tongue Diagnosis System. From those acquired tongue images, each coating section were extracted by oriental doctors, and then mean values of multi -dimensional color vectors in each coating section were calculated. By statistical analysis, two significant vectors, R in RGB space and H in HSV space, were found that they were able to describe the difference between white coating section and yellow coating section very well. Using these two values, we designed the discriminant function for coating classification and examined how good it works. As a result, the overall accuracy of coating classification was 98.4%. We can expect that the discriminant function for other coatings can be obtained in a similar way. Furthermore, if an automated segmentation algorithm of tongue coating is combined with these discriminant functions, an automated tongue coating diagnosis can be accomplished.

  • PDF

DYNAMICAL SUBSTRUCTURES OF GALACTIC GLOBULAR CLUSTERS I. M5 (우리은하 구상성단들의 역학적 세부구조 I. M5)

  • Rhee, Jong-whan;Sohn, Young-Jong
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.3
    • /
    • pp.181-190
    • /
    • 2004
  • We use BV CCD images to study the dynamical substructure of the globular cluster M5. We investigate the radial variation of ellipticities and position angles using the stellar photometry and the IRAF ellipse task. We find that out to three times the half light radius $(r_h)$, the changes in ellipticities and position angles range in $0.05\~0.25$ and $75^{\circ}\~-75^{\circ}$, respectively. There are no significant discrepancy in the dynamical substructure beyond $r_h$ among the different giant populations. However, compared to the global dynamical substructure of M5, the inner $(<0.5r_h)$ substructure of the bright red giant and the horizontal branch populations show slightly different patterns. Especially, the discrepancy of the bright red giant population with respect to the global substructure, ranges up to 0.1 for the ellipticity and 1000 for the position angle.

Stability Analysis of Nonhomogeneous Slopes by Log -spiral Failure Surface (이질토층사면의 대수누선파양에 대한 안정해석)

  • Kim, Yeong-Su;Seo, In-Seok;Baek, Yeong-Sik
    • Geotechnical Engineering
    • /
    • v.9 no.2
    • /
    • pp.41-54
    • /
    • 1993
  • This paper presents the two and three -dimensional stability analysis of nonhom- ogeneous, c-o soil slopes. Potential failure surface is assumed as a logspiral curve refracted in boundaries of layers. In 3-D analysis, rotational soil mass is assumed with a cylindroid central part terminated with plane ends. Seismic force is considered by sesmic intensity. The program developed in this study is compared with the program PCSTABLS. The ratio of three-dimensional minimum factor of safety to two-dimensional case is examined and factor of safety changes are showed for the ratio of cylindroid length to slope height and numbers of slice. On such bases the following conclusions may by made : (1) The program developed in this program is less conservative than the program PCSTABLS. (2) The value of F2 of this study shows the larger differences than that of PCSTABLS with increasing friction angle (3) Factors of safety computed for 3-D geometry differ considerablely from ordinary 2-D factors of safety. Since Fb/F2 exceeds unity, three -dimensional effects tend to increase the factor of safety. (4) As the ratio of three - dimensional failure width of slope height, b/H increase, the value of Fb/Ff decreases and approaches 1.0 when bye is 14. (5) In calculating the factor of safety using the developed program the number of slices is suitable with the ranges of 30-40

  • PDF

Evaluation of Various Cardiae Indices and ROC Analysis in Coronary Artery Disease Employing Resting ECG Gated Blood Pool Scan (관상동맥질환에서 휴식기 심전도게이트혈액풀스캔을 이용한 각종 심기능 지표들의 평가 및 ROC 분석)

  • Choi, Chang-Woon;Lee, Dong-Soo;Kim, Sang-Eun;Chung, June-Key;Lee, Myung-Chul;Park, Young-Bae;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.40-48
    • /
    • 1992
  • Gated blood pool scan is frequently used for evaluating the change in cardiac function in various cardiac diseases. But resting gated blood pool scan using only LVEF as a cardiac index has been consitently shown to have a low sensitivity, which is about 50%, in detecting coronary artery disease. So it is recommended to compare exercise gated blood pool scan to resting gated blood pool scan. Exercise tests, however, are not always possible, especially in patients with musculoskeletal diseases, recent myocardial infarction and in elderly persons. We studied the usefulness of resting gated blood pool scan using multiple indices in evaluating the patients with coronary artery disease. Studied cases were 185 patients with coronary artery disease (angina pectoris 31, myocardial infarction 154) and 25 normals with low likelihood of coronary artery disease. We used $^{99m}Tc-labeled$ RBC, 740 MBq labeled by in vivo method. The data were evaluated by Micro DELTA computer program. The results were as following: 1) The ejection rates (PER, AER) and filling rates (PFR, AFR) were different in normls and patients with angina pectoris or myocardial infarction. 2) Mean phase angle, ejection rates and filling rates could separate normals from coronary artery disease patients with normal LVEF. 3) Regional ejection fraction was decreased at the site of the infarct in patients with myocardial infarction. 4) Peak filling rate was the the most detectable index in evaluation of cardiac function in patients with coronary artery disease. 5) The threshold at 1.5 standard deviation of normal range was considered as the most reliable cut-off value from ROC analysis. These data suggest that the resting gated blood pool scan has an important role in the evaluation of cardiac functional changes using various cardiac indices in patients with coronary artery disease.

  • PDF

Surface Characteristics and Physical Properties of Cotton Fabric for Patient Clothing Material through a Chitosan/Nanosilver Colloidal Solution (환자복 소재용 면직물의 키토산/은나노 콜로이드용액 처리에 따른 표면 특성과 물리적 성질)

  • Jeong, Kyoung-Mi;Bae, Hyun-Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.12
    • /
    • pp.1873-1882
    • /
    • 2009
  • Hospital patient clothing material was treated with a mixture of chitosan in order to enhance functionality, such as the durability and dimensional stability of the cotton fabric used. Chitosan is a natural polymer with excellent biocompatibility, however there is a deteriorating adherence efficiency. The addition of a nanosilver colloidal solution in accordance with a prescribed ratio can further increase the performance of chitosan. Changes in the structural characteristics and physical properties of the chitosan/nanosilver treated fabric were observed in a comparison with fabric treated only with chitosan. The add-on ratio increased when the mixing ratio of nanosilver colloidal solution was higher; however, the crystalline structure of the treated fabric remains similar. In the case of CH3/NS1 treated fabric (where the mixing ratio of chitosan and nanosilver solution was 3:1) the K/S value, whiteness index, wet tensile strength, and wrinkle recovery angle were superior. The dimension stability, pilling resistance, and abrasion resistance of the fabric treated with a mixed solution increased in comparison to the fabric treated only with chitosan. The chitosan/nanosilver treated cotton fabric used for patient clothing material has excellent physical properties.

OPTIMAL DEELECTION OF EARTH-CROSSING OBJECT USING A THREE-DIMENSIONAL SINGLE IMPULSE (3차원에서의 순간적인 속도변화에 의한 ECO의 최적궤도변경)

  • Mihn, Byeong-Hee;Park, Sang-Young;Roh, Kyoung-Min;Choi, Kyu-Hong;Moon, Hong-Kyu
    • Journal of Astronomy and Space Sciences
    • /
    • v.22 no.3
    • /
    • pp.249-262
    • /
    • 2005
  • Optimization problems are formulated to calculate optimal impulses for deflecting Earth-Crossing Objects using a Nonlinear Programming. This formulation allows us to analyze the velocity changes in normal direction to the celestial body's orbital plane, which is neglected in many previous studies. The constrained optimization in the three-dimensional space is based on a patched conic method including the Earth's gravitational effects, and yields impulsive ${\Delta}V$ to deflect the target's orbit. The optimal solution is dependent on relative positions and velocities between the Earth and the Earth-crossing objects, and can be represented by optimal magnitude and angle of ${\Delta}V $ as a functions of a impulse time. The perpendicular component of ${\Delta}V $ to the orbit plane can sometimes play un-negligible role as the impulse time approaches the impact time. The optimal ${\Delta}V $ is increased when the original orbit of Earth-crossing object is more similar to the Earth's orbit, and is also exponentially increased as the impulse time reaches to the impact time. The analyses performed in present paper can be used to the deflection missions in the future.

A Study on the Development and Application of Perilla Oil Based Compound Wax Agent for Preserving Outdoor Metal Sculpture: A Case Study on Iron Sculptures (들기름 기반 야외 금속 조형물 보존용 혼합 Wax의 개발 및 적용성에 관한 연구: 철제 조형물 중심으로)

  • Oh, Seung-Jun;Wi, Koang-Chul
    • Journal of Conservation Science
    • /
    • v.33 no.2
    • /
    • pp.121-130
    • /
    • 2017
  • The currently used wax agents for preserving outdoor metal structures, despite their advantages, have disadvantages such as low endurance and reliability. These wax agents are easily damaged by acid rain, dust, moisture in the air, yellow dust, and air pollutants, resulting in corrosion within a short period after the initial conservation treatment. In addition, aged wax can also exhibit changes in the color or gloss, and also give a sense of difference in the surface. Given these existing problems, it is necessary to develop improved materials for metal preservation. Therefore, this study analyzed the characteristics and applications of the existing wax coating agents in order to identify their disadvantages and to develop a better material for metal preservation. In this regard, this study developed a perilla oil based compound wax and conducted experiments to test its endurance. The new compound wax agent was exposed to outdoor and acid rain conditions: it showed four times and 1.5 times the endurance of the existing wax agents in outdoor and acid rain conditions, respectively. In addition, the new agent seems to be more durable and protective as evidenced by the chromaticity, polish maintenance, and contact angle results. Further, although it is 1.3-1.8 times thicker than the existing agents, the new agent shows a more even surface. Based on these findings, it can be concluded that the new compound wax agent based on perilla oil is a better alternative to the existing was coating agents.

Biomechanical Effects of Facet Capsule Injuries in Posterior Lumbar Fusion Operations (후방경유 요추 융합수술시 척추후관절낭 손상의 운동역학적 영향)

  • Park, Seung Won;Kim, Young Baeg;Hwang, Sung Nam;Choi, Duck Young;Kwon, Jeong Taik;Min, Byung Kook;Suk, Jong Sik
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.3
    • /
    • pp.358-365
    • /
    • 2001
  • Objectives : Although posterior lumbar fusion operations had been reported to accelerate spinal degeneration, there have been only a few studies for their biomechanical effects. We have studied the change of motion range at the vertebral joint one level above the fusion(UVJ) in pedicle screw fixation group(PSF)(n=13) where facet capsule was destroyed and in posterior lumbar interbody fusion group(PLIF)(n=8) where it was spared. Patients and Methods : The patients were divided into early(3 to 6 months) and late(over 12 months) according to postoperative follow-up period. The flexion, extension and flexion-extension angles(FA, EA, FEA) were measured at the UVJ with pre-operative, early and late post-operative films. Results : Mean age and male to female ratio were $52.7{\pm}9.3$ and 1 : 3.2. Mean follow-up periods were $144.1{\pm}30.0$ and $528.8{\pm}160.3$ days in early and late groups, respectively. The FEA and FA in the late PSF($11.8{\pm}3.1$, $8.5{\pm}2.9$) were significantly greater than pre-operative angles($7.8{\pm}3.9$, $5.1{\pm}3.7$)(p<0.01, p<0.05). All angles in the PLIF showed no significant changes with time. The FEA and FA in the late PSF($11.8{\pm}3.1$, $8.5{\pm}2.9$) were significantly greater than those of the late PLIF($7.6{\pm}2.3$, $3.4{\pm}2.0$)(p<0.01, p<0.001). All angles at early follow-up period were similar between PSF and PLIF. The EA showed no significant change in relation with follow-up period or fusion method. Conclusion : As a result, the facet capsule injury in pedicle screw fixation seems to be related with increased flexion angle or degeneration of the adjacent joint above the fused vertebra in the late phase.

  • PDF

Evaluation of the Shape Accuracy of Turning Operations (선삭가공에서의 형상 정밀도에 대한 평가)

  • Park, Dong-Keun;Lee, Joon-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.1645-1651
    • /
    • 2015
  • This paper describes the changes of shape accuracy in workpiece materials depending on the turning clearance angle. The experiments started from choosing three workpiece materials, SM45C(machine structural carbon steel), STS303(stainless steel) and SCM415 (chrome-molybdenum steel). The experiments showed specifically how features of selected materials changed when they were processed with diverse machining depths, 0.1 mm, 0.2 mm and 0.3 mm, with various negative angles, $0.0^{\circ}(-6.0^{\circ})$, $0.3^{\circ}(-6.3^{\circ})$ and $0.9^{\circ}(-6.9^{\circ})$, and called cutting edge inclination starting from a fixed rotational speed, 2,500 rpm, focusing on the feed rate, 0.07 mm/rev and 0.10 mm/rev. The results of the accuracy of processing, cylindricity, deviation from coaxiality, etc. were compared using the graph and table. The accuracy of cylindricity in the order of degree $0.0^{\circ}{\rightarrow}0.3^{\circ}{\rightarrow}0.9^{\circ}$ depending on the workpiece materials showed the best cylindricity when it was $0.9^{\circ}$. In conclusion, the accuracy improved in specific degrees irrespective of the quality of the materials when the bite negative angles increased. This means that workability improved in these experiments. In addition, the processing shape changed depending on depth of the cut and feed rate.