• 제목/요약/키워드: Anechoic Chamber

검색결과 248건 처리시간 0.03초

고 흡입저항을 가진 원심 송풍기 (Centrifugal Blower with High Inlet Resistance)

  • 김재원
    • 한국유체기계학회 논문집
    • /
    • 제6권2호
    • /
    • pp.15-22
    • /
    • 2003
  • Comprehensive study on a centrifugal blower for air-purifier involving a few physical filters for percolation process has been accomplished for an optimal design of the air handling system. The filtering media causes a flow resistance for induced flows by a rotating impeller. The present methodology is to adopt PIV system for velocity measurements and wind tunnel connected with an anechoic chamber for total performance test of the blower. Trial prototypes for the blades of a rotor and casing are presented for satisfaction of both flow rate and noise level set by design objectives. Tapered blades with a special casing for a fan show good performance data. The results of velocity fields also explain the reason of improvements of the blower performance.

Design of an Array Antenna Hood for Jamming Simulator

  • Kim, Mi-Suk;Ju, Jeong-Gab;Kim, Jong Seong;Son, Seok Bo;Yun, Sang Jun
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제3권2호
    • /
    • pp.63-69
    • /
    • 2014
  • In this study, due to the necessity of the equipment for inspecting an anti-jamming function depending on the expansion of the development of anti-jamming systems, an array antenna hood that can inspect the anti-jamming function of an anti-jamming system while being installed at the system was designed and manufactured. The manufactured array antenna hood plays a role in radiating GNSS signals and jamming signals. Based on an experiment, it was demonstrated that using a near-field radiation method, the manufactured array antenna hood could be used for examining the normal operation of an anti-jamming system function in outdoor or indoor environments rather than an anechoic chamber.

정압을 이용한 직교류팬 주변의 소음 예측 (Estimation of Noise Level near Cross Bow Fan by Measurements of Static Pressure.)

  • 김재원;조용;정윤영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.1156-1161
    • /
    • 2001
  • A significant trial has been performed for estimation of noise level of a cross flow fan for air conditioning system. In general, measurements of noise level of machinery require rigorous equipment involving an anechoic chamber with precision gauges. The apparatus is expensive to utilize and is not easy to construct. In this work, we adopt static pressure sensing from an ordinary pressure transducer for prediction of noise level of a rotating fan. The present procedure is finding sound pressure from the static pressure by manipulating Light-Curle equation depicts noisy energy in terms of pressure on surfaces of noise generators. Sound power level near core unit of the fan is evaluated with the present methodology in a normal laboratory room without any sound absorbers. The method is easy and shows good prediction results compared with precise measurements by using microphones.

  • PDF

철도소음 저감 향상을 위한 방음벽 상단의 능동제어장치 (Actively controlled sound field on the top edge of noise barriers for railway noise reduction)

  • 고효인;조준호;김재철;이찬우;한환수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.332-337
    • /
    • 2005
  • In this study the sound field on the surface of the top edge of noise barriers is actively minimized to enhance the shielding effect without increasing the hight of the barrier. First the results of a numerical study are shown; the sound field reduction in the far field due to a cylindrical active headpiece attached to a semi-infinite screen and the related control parameters are investigated. The results of a model experiment in an anechoic chamber and optimal control parameters for noise control on the railway side are shown and discussed.

  • PDF

경계요소법을 이용한 음원의 자유음장 복원에 대한 연구 (A study for the- reconstruction of free field sound source from the measured data in a closed wall by using Boundary Element Method)

  • 최한림;이덕주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1747-1751
    • /
    • 2000
  • It is well known that acoustic signals, even measured in an anechoic chamber, can be contaminated due to the wall interference. Therefore, it is necessary to reconstruct the original signal from the measured data, which is very critical for the case of measurement of source signal in a water tunnel. In this thesis, new methods for the reconstruction of sound sources are proposed and validated by using Boundary Element Method from measured data in a closed space. The inverse Helmholtz integral equation and its normal derivative are used for the reconstruction of sound sources in a closed space. An arbitrary Kirchhoff surface over the sources is proposed to solve the surface information instead of direct solution for the source. Although sound sources are not directly known by the inverse Helmholtz equation, the original sound source of pressure-field outside of the wall can be indirectly obtained by using this new method.

  • PDF

교통소음제어를 위한 간섭형 방음장치 형상개발에 관한 연구 (A study on the shape development of interference device for vehicle noise control)

  • 장강석;심상덕;김영찬;김두훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1778-1783
    • /
    • 2000
  • When visual intrusion is an important factor, it is desirable to find alternative methods of improving the insertion loss of a noise barrier without increasing the height. Therefore, the primary object of the work attenuates the noise due to transport vehicle by small interference device installed at noise barrier edge. In this paper the performance of noise barriers with attached interference device, in terms of shape, absorptive material and split panel, are examined using the boundary element approach. Also, the scale models are moanted in an anechoic chamber and the frequency of the sound sources are appropriately scaled to simulate full scale site conditions. Lastly, experimental measurements of the designs are executed for a range of frequencies and receiver positions, and are compared with the results of numerical modeling.

  • PDF

저가의 EMI/EMS 측정 시스템 - 표준, 개량형 TEM Cell

  • 윤재훈;이애경
    • 한국전자파학회지:전자파기술
    • /
    • 제4권1호
    • /
    • pp.51-58
    • /
    • 1993
  • 일반적으로 EMI 측정시험장으로 활용되고 있는 시설로서는 야외 시험장(open site)과 전자파 무반사실 (anechoic chamber)이 있다. 전자의 경우는 전자파 간섭 영향이 없어야 하고 반사 또는 커플링의 영향을 줄 수 있 는 장애물이 없어야 하는 시험환경 조건이 요구되지만, 근래의 전자기기 사용증가, 방송, 무선 통신시스템의 다양화 및 산업의 복잡화에 따른 인공잡음의 증대로 그 선정이 극히 어려워 도시에서 멀리 떨어진 곳, 즉 연구 개발 및 제품 생산 소재지로 부터 멀리 떨어진 곳에서나 가능하게 되었으며, 그외에도 기상조건에 의한 영향 및 주변 개발에 의한 잡음 환경의 변화로 성능 보존이 어렵다. 후자의 경우는 야외 시험장의 전자파 환경 문제점을 피할 수 있어, 도시나 혹은 제품 생산지 가까이에 설치 운용이 가능하나 이들 모두 수억에서 십수억원에 이르는 설치 비용이 들어 중소 업체에서 보유하기가 어렵다. 또한 안테나 를 송수신원으로 사용하므로서 저주파수대 측정이 어려울 뿐만 아니라 피시험체주변 공간(반경 3, 10M)에서의 1점 측정 방식으로 인해 측정시간이 많이 소요되는 기술적인 문제점을 지니고 있다.

  • PDF

전파무향실을 위한 광대역 페라이트 전파흡수체

  • 김동일;손준영
    • 한국전자파학회지:전자파기술
    • /
    • 제14권1호
    • /
    • pp.43-50
    • /
    • 2003
  • 전자산업과 전파통신기술이 고도로 발전함에 따른 전파 이용의 증대로 인해 전자파환경 EMI/EMS이 사회적 문제를 야기하고 있다. 이에 따라, CISPR(Comite Internationale Special des Perturbations Radioelectrique), FCC (Federal Communications Commissions) ANSI (American National Standards Institute)등의 기구는 EMI/EMC 대책을 위해 전파환경의 규정을 제정하고 있다. 또한 EMI/EMC 측정을 위한 전파무향실(anechoic chamber)용 전파흡수체는 20 dB 이상의 전파흡수능이 요구된다. 종래의 EMI 측정 주파수 범위는 30 MHz~l,000 MHz 이었으나 1998년 11월, CISPR11은 1 GHz~18 GHz를 추가하는 안을 받아들였다. 본고는 새로운 형태의 다층형 페라이트 전파흡수체를 제안하고 등가재료정수법을 사용하여 광대역 설계를 시도한 것이다.

고출력 전자기 펄스에 따른 PC 시스템의 민감성 분석 (Susceptibility of PC-Systems to HPM(High-Power Microwave) Threats)

  • 황선묵;홍주일;한승문;김광용;허창수;이기택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1432-1433
    • /
    • 2008
  • Disruption and upset of computer system from intentional unintentional electromagnetic wave is not tenable, if the equipment is used in a security or safety critical application. This paper examines susceptibility of computer network to the HPM. The susceptibility level for PC-systems has been assessed using anechoic chamber. The some failure mode were observed in PC-system. Based on the results, susceptibility of computer network can be applied to database to elucidate the effects of microwaves on electronic equipment.

  • PDF

무향실의 설계 및 제작 (The Design and Construction of the Anechoic Chamber)

  • 이득웅
    • 기계저널
    • /
    • 제35권10호
    • /
    • pp.896-902
    • /
    • 1995
  • 소음의 저감 대책은 소음원의 소음 감쇠, 소음 전달 경로의 소음 저감 및 수음자에 대한 대책 으로 나눌 수 있다. 여기에서 소음원의 소음 저감 대책을 세우기 위해서는 소음원의 주파수 특 성을 정확하게 분속해야 하고 이를 위해서는 자유음장이라는 공간이 필요하게 된다. 음향학적 으로 자유음장이란 점음원으로부터 무지향적으로 방사되는 음의 음압레벨(sound pressure level )을 따르는 음장으로 정의된다. 이는 음원으로부터 거리가 두 배 증가함에 따라 음압레벨이 6dB 감소함을 의미한다. 즉, 주변 소음으로부터 발생한 음이 다른 물체나 벽으로부터 반사된 반사음 이나 회절음의 영향을 받지 않는 음장을 말한다. 자유음장은 자연계에서 극히 제한적으로 존재 하지만 인간이 측정장비 및 측정 대상물을 이동시켜 이용할 수 없으므로 인공적인 시설로서 무 항실을 만들어 자유음장 환경을 조성한다. 이 글에서는 무항실의 특성 및 국내에서 시공되는 무향실의 설계 및 제작 과정을 간단히 소개하고 현재의 국내 무항실의 수준과 앞으로 나아갈 방항을 제시하고자 한다.

  • PDF