• 제목/요약/키워드: Anechoic Chamber

검색결과 247건 처리시간 0.03초

첨단자동차의 전자파 내성 실험 환경에 관한 연구: 레이더 센서를 중심으로 (Electromagnetic Immunity Test Environments of Advanced Vehicles with Radar Sensor Systems)

  • 김성범;류지일;우현구;용부중
    • 자동차안전학회지
    • /
    • 제11권4호
    • /
    • pp.50-56
    • /
    • 2019
  • Recently, automobile industries have developed ADAS, smart cars, connected cars, automated driving systems, which use a variety of sensor systems - ultrasonics, cameras, lidars and radars - and communication systems. It is necessary to examine the electromagnetic immunity of vehicles equipped with those systems. The electromagnetic immunity tests are carried out in an electromagnetic semi anechoic chamber, which is cut off from the outside. It is difficult to create test environments in which the radar sensor systems of vehicles work properly in the test chamber. In this study, test jigs were designed and tested and as a result they are shown to be effective to create test environments for electromagnetic immunity tests of vehicles equipped with radar sensors. We also proposed additional safety standards for immunity tests of vehicles with radar systems that currently do not exist.

첨단자동차의 전자파 내성 실험 환경에 관한 연구: 카메라 센서를 중심으로 (Electromagnetic Immunity Test Environments of Advanced Vehicles with Camera Sensor Systems)

  • 우현구
    • 자동차안전학회지
    • /
    • 제12권4호
    • /
    • pp.7-12
    • /
    • 2020
  • Recently, automobile industries have developed ADAS, smart cars, connected cars, automated driving systems, which use a variety of sensor systems - ultrasonics, cameras, lidars and radars - and communication systems. It is necessary to examine the electromagnetic immunity of vehicles equipped with the sensor systems due to the fact that the normal operation of those systems is very important to the safety of the vehicles. The electromagnetic immunity tests are carried out in an electromagnetic semi anechoic chamber, which is cut off from the outside. It is difficult to create test environments in which the camera sensor systems of vehicles work properly in the test chamber. In this study, test jigs were designed and tested and as a result they are shown to be effective to create test environments for electromagnetic immunity tests of vehicles equipped with camera sensors. We also proposed additional safety standards for immunity tests of vehicles with camera systems that currently do not exist.

첨단자동차의 전자파 내성 실험 환경에 관한 연구: 외부통신 장치를 중심으로 (Electromagnetic Immunity Test Environments of Advanced Vehicles with Communication Systems)

  • 우현구
    • 자동차안전학회지
    • /
    • 제14권1호
    • /
    • pp.14-19
    • /
    • 2022
  • Recently, automobile industries have developed ADAS, smart cars, connected cars, automated driving systems, which communicate with outsides of a vehicle not only in uni-directional way but also in bi-directional way. It is necessary to examine the electromagnetic immunity of vehicles equipped with those communication systems. The electromagnetic immunity tests are carried out in an electromagnetic semi anechoic chamber, which is cut off from the outside electromagnetically. In this study, additional test environments were designed and tested and as a result they are shown to be effective to create test environments in an experimental chamber for electromagnetic immunity tests of vehicles equipped with communication systems.

Antenna의 Passive IMD 측정 (The Measurement of Passive Intermodulation Distortion in Anten)

  • 조인귀;정명영;최태구
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2000년도 종합학술발표회 논문집 Vol.10 No.1
    • /
    • pp.337-340
    • /
    • 2000
  • 본 논문에서는 안테나의 PIMD 측정에 있어 신뢰성과 재현성에 관한 문제점을 검토하였으며, 향후 새로운 구조의 Anechoic Chamber의 필요성에 관해 기술하였다. 패치 안테나를 일반적인 안테나용 Chamber에서 PIMD를 측정한 결과 재현성에 있어 문제점이 있음을 확인하였으며, 그 원인이 피라미드 구조의 흡수체에 있음을 실험을 통해 확인하였다.

  • PDF

Design and Fabrication of Wide-band Ferrite Absorber Used in Anechoic Chamber

  • Kim, Sung-Soo;Park, Ik-Kown
    • Journal of Magnetics
    • /
    • 제2권1호
    • /
    • pp.25-27
    • /
    • 1997
  • Ferrite tile absorber is of great concern for the application to anechoic chambers due to the growing demand of EMI or EMC measurements. This paper investigates the magnetic, dielectric and microwave absorbing properties of a Ni-An ferrite for the purpose. A design chart was constructed with the solutions of impedance-matching equation in the radio frequencies (30 MHz - 1 GHz). The material parameters for zero-reflection are predicted from the chart. The magnetic and dielectric properties of sintered Ni-Zn ferrite is found to be well suited for this requirements. A superior microwave absorbing properties (frequency band and absorber thickness) of the samples are demonstrated.

  • PDF

소리의 지향성 측정을 위한 전기음향실험기기의 자동화 (Automation of electrical acoustic experimental apparatus for the directivity measurement of sound)

  • 장순석;고재하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.574-576
    • /
    • 2004
  • The directivity of the sound pressure increases the sensitivity of the incoming sound from specific directions. The directivity measurement of the sound pressure is usually done in an anechoic room using a sloping motor. In this paper a replaceable anechoic chamber was designed for the acoustic directivity pattern measurement. Electrical equipments were interfaced with a PC for experiment automatic control. Some comparative results are shown in the result.

  • PDF

소리의 방향성 측정을 위한 실험기기의 자동제어 (Automatic control of experimental apparatus for sound's directivity measurement direction acoustic wave)

  • 장순석;고재하;이제형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.591-594
    • /
    • 2004
  • The directivity of the sound pressure increases the sensitivity of the incoming sound from specific directions. The directivity measurement of the sound pressure is usually done in an anechoic room using a steping motor. In this paper a replaceable anechoic chamber was designed for the acoustic directivity pattern measurement. Electrical equipments were interfaced with a PC for experiment automatic control. Some comparative results are shown in the result.

  • PDF

무향실.반무향실의 음향설계 (Acoustic Designing of Anechoic & Semi-Anechoic Chamber)

  • 김종철;최순근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1990년도 추계학술대회논문집; 한양대학교, 서울; 24 Nov. 1990
    • /
    • pp.59-64
    • /
    • 1990
  • 음향측정에 사용되는 무향실은 각종 정밀측정을 하는데 기본적인 중요설비 로 소리의 환경을 인위적으로 만든 설비이다. 무향실은 자유음장을 형성하는 실로 실내 모든면에서 음을 완전히 흡수하여 "음의 반사가 없는 실"을 말하 며, 실제 주변환경에서는 찾아보기 힘든 일이다. 이전에는 주로 Speaker나 Microphone등의 지향특성 및 교정에만 국한되어 사용했지만 현재 각종 기계 류의 방사 Power측정, 측정실내의 객관적인 교정검사, 기자재의 객관적인 음 향측정 데이터 비교평가등 무향실을 이용한 음향분석연구가 각 분야에서 광 범위하게 이용되어지고 있다.이용되어지고 있다.

  • PDF

철도소음 저감을 위한 간섭형 방음장치 음향 설계 및 성능시험에 관한 연구 (A study on the performance test and acoustic design of interference type noise reduction device for railway noise)

  • 조준호;고효인
    • 환경영향평가
    • /
    • 제20권6호
    • /
    • pp.787-795
    • /
    • 2011
  • Noise barrier is generally used with welding of joint rail for railway noise reduction in our country. But the noise barrier for high speed railway has weak point in low frequencies about 315Hz band. In this study, For developing of Interference-type Noise Reduction Device(INRD), acoustic analysis were performed using commercial software. For verifying the improvement in the noise reduction, noise measurement before and after installing of INRD were performed in Anechoic Chamber. From these acoustic analysis and noise measurement, it was known that developed INRD has a good noise reduction performance and can be used efficiently with conventional noise barrier.

Effects of External PIM Sources on Antenna PIM Measurements

  • Kim, Jin-Tae;Cho, In-Kui;Jeong, Myung-Yung;Choy, Tae-Goo
    • ETRI Journal
    • /
    • 제24권6호
    • /
    • pp.435-442
    • /
    • 2002
  • Antenna Passive Intermodulation (PIM) level measurement results are rarely credited to be due to external signal receiving characteristics of the antennas or serious effects from external PIM sources, such as the anechoic chamber absorber and antenna tower. This paper presents an antenna PIM model for a reflected PIM measurement method. Based on the findings of null point generation and the behavior of the third order PIM values obtained by theoretical predictions and experimental results, we concluded that the results of the antenna PIM level test were influenced by the external PIM sources generated by the anechoic chamber absorber and the path differences of PIM signals coming into the antenna.

  • PDF