The objective of this study was to investigate the effect of storage time on fresh boar semen in Androhep and Beltsville Thawing Solution (BTS). Boar semen samples extended in each extender were stored at $17^{\circ}C$ up to 4 days. Sperm motility kinematics was evaluated by computer assisted sperm analyzer (CASA) and capacitation status by chlortetracycline (CTC)/Hoechst 33258 staining. Sperm motility (%) was not decreased during storage in BTS and Androhep. No significant difference between extenders was observed. Only significant differences in kinematic parameters on linearity during storage were found. The percentage of dead sperm significantly decreased during storage (p<0.05). Also the percentage of noncapacitated, capacitated, and acrosome-reacted sperm significantly modified during storage (p<0.05). However, there was no significant difference between extenders except proportion of capacitated sperm. This finding supported that modification in these parameters was not significantly different between extenders during this short-term storage. Our finding strongly indicated that both Androhep and BIS maintained favorable conditions for motility, motility kinematics, and capacitation status during short-term storage. Despite modifications in some parameters were apparent during sperm storage in extenders, these may not affect the fertilizing capacity of boar semen.
돼지 인공수정센터에서 사육중인 인공수정용 종모돈을 이용하여 1995년부터 2000년까지 보존액 종류, 보존온도 및 보존기간에 따른 정액성상 변화와 번식성적을 조사하여 돼지 인공수정시 번식성적 향상과 실용화에 기여코자 본 연구를 실시하였다. 1. 돼지 액상정액의 보존액 종류에 따른 보존기간별 활력은 Androhep 보존액은 3일째부터, BTS 및 Modena는 5일째부터 현저하게 감소하는 경향을 보였고 (P<0.05), pH변화는 6.24~7.06 범위에서 변이가 심하게 관찰되었으며 Androhep 보존액이 산도가 낮은 경향을 보였으나 전반적으로 규칙 적 인 경향을 나타내었다. 보존액 종류별 보존기간에 따른 분만율은 BTS, Modena 및 Androhep 보존액 모두 5일 보존까지 차이가 없었다. 보존액별 분만율은 Androhep 보존액이 BTS 보존액과는 차이가 없었으나 1일 보존과 5일 보존에서 Modena보존액 보다 우수하였다 (P<0.05). 산자수는 보존 기간별 보존액간에 차이는 없었으나 Androhep 보존액은 3일 보존부터 산자수가 유의적으로 감소하였다 (P<0.05). 2. 보존온도에 따른 액상정액의 운동성과 정상첨체 비율에서 17$^{\circ}C$ 보존정액의 운동성은 3일째부터, 정상 첨체율은 4일째부터 감소하였으나 5$^{\circ}C$ 보존정액은 4일 보존까지 정액성상의 변화가 크지 않은 것으로 나타났다. 17$^{\circ}C$에 보존한 액상정액이 5$^{\circ}C$에 보존한 것보다 분만율은 현저히 높았으나 산자수는 비슷한 경향을 보였고, 분만율은 보존 2일째부터 산자수는 3일째부터 감소하였다. 5$^{\circ}C$ 보존정액은 4일까지 분만율에 큰 변화가 없었으나 산자수는 다소 감소하는 경향을 보였다.
The objective of this study was to investigate the motility and kinematics of boar sperm that while stored at 4C. The samples of fresh boar semen were place into an extender, Androhep, and stored at $4^{\circ}C$. In three of these samples, cryoprotectants were added. The sperm's motilities and kinematics were evaluated by using microscope (${\times}400$) and the viability status was evaluated by using with eosin staining method. The 5 sample groups are; Goup A:Androhep (extender), stored at $17^{\circ}C$. Group B:Androhep (extender), stored at $4^{\circ}C$. Group C:Androhep (extender), + 3% glycerol (cryoprotectant), stored at $4^{\circ}C$. Group D:Androhep (extender), + 3% DMSO (cryoprotectant), stored at $4^{\circ}C$. Group E:Androhep (extender), + 3% ethylene glycol (cryoprotectant), stored at $4^{\circ}C$. In group A, the sperm's motility was reduced. On day one the sperm's motility was ($85.7{\pm}2.3$) and day 5 the motility was ($43.9{\pm}3.3$). In group B, C and D the sperm's motility were reduced to 0 on day 5. In group E the sperm's percentage of motility decreased. On day one the sperm's motility was ($42.0{\pm}0.5$) and day 5 the motility was ($2.3{\pm}0.3$). When comparing cryoprotectant in samples of boar sperm there is a slight improvement in the results when the use of Androhep Lite (extender), + 3% ethylene glycol (cryoprotectant), stored at $4^{\circ}C$ are used. Based on these results, ethylene glycol can protect sperm from heat shock at $4^{\circ}C$, but not satisfactory level. However, it showed the possibilities of liquid semen preservation at $4^{\circ}C$ by using cryoprotectant.
The aim of this study was to investigate the effect of sperm preservation according to the various kinds of commercially available semen extenders and to investigate the effect of sperm preservation according to the various temperature storages of fresh-extended porcine semen. To investigate the effect of sperm preservation according to the various kinds of commercially available semen extenders, porcine semens diluted in 3 semen extenders, Beltsville Thawing Solution(BTS), Androhep and Kiev, were cooled at $8^{\circ}C$ storage temperature with a controlled cooling rate of $2-4^{\circ}C$/h. Motility, progressive motility, normal sperm(%) and sperm morphology were assessed comparatively. In motility and progressive motility, Androhep extenders revealed better result than other extenders. In normal sperm(%) and sperm morphology, 3 semen extenders revealed similar results. To investigate the effect of sperm preservation according to the various temperature storages of fresh-extended porcine semen, porcine semens diluted in BTS extender, were cooled at 3 storage temperatures($8^{\circ}C$, $12^{\circ}C$ and $17^{\circ}C$) with a controlled cooling rate of $2-4^{\circ}C$/h. Motility, progressive motility, normal sperm(%) and sperm morphology were assessed comparatively. In motility and progressive motility, $8^{\circ}C$ treatment group revealed better result than $12^{\circ}C$ and $17^{\circ}C$ treatment groups. In normal sperm(%) and sperm morphology, 3 temperatures of treatment groups revealed similar results.
The purpose of this study was to assess sperm quality during in vitro storage of miniature-pig semen in order to determine which extender should be used and how extender can be diluted for in vitro storage of miniature-pig semen. Freshly ejaculated miniature-pig's semen was diluted with same volumes of Beltsville Thawing Solution (BTS), Androhep, Modena, Mulberry III and modified-Modena extenders. Sperm quality was evaluated by examining viability, motility, abnormality, acrosome intactness, intensity and capacitation status by chlorotetracycline (CTC) staining. Sperm motility decreased with storage period prolonged and differences among BTS, Androhep, Modena and Mulberry III were apparent On Day 1, approximately 80% of the sperm were motile, but motility decreased to $40\%$ at Day 7. During the 7 days of storage, sperm survival in modified-Modena B extender was higher than another extenders. However, it was not differ significantly among other extenders. The percentage of F and B patterns were not differ significantly among the extenders. However, F pattern in modified-Modena B extender was slightly higher until 3 days of storage than that of Modena extender, modified-Modena A extender and modified-Modena C extender. The percentage of AR patterns in modified-Modena B extender was slightly lower, but did not differ significantly among other extenders. The results of present study suggest that modified-Modena B was effective as new extender for in vitro storage of miniature-pig semen.
MTT (3-(4, 5-dimethyl thiazol-2-yl)-2, 5-diphenyl tetrazolium bromide) reduction assay is a method that validates the viability of an active cell. Dehydrogenase in mitochondria converts yellow colored insoluble tetrazolium salt to purple colored water-soluble formazan. Sperm also have mitochondria in the midpiece, therefore sperm viability could be evaluated by MTT reduction assay. Several studies have already demonstrated the capability of application of the MTT reduction assay to sperm of several species in Hepes-BSA buffer. Because most liquid semen was diluted in extender like BTS (Beltsville Thawing Solution), Modena or Androhep when it is used or transferred, semen needed another dilution in Hepes-BSA buffer to assess sperm viability. In this study, we evaluated boar sperm viability especially in BTS extended semen and compared the efficiency of this test with eosin-nigrosin staining. We used the fresh BTS extended semen from a local A.I center. Semen sample was diluted to $3.0{\times}10^7$ sperms/ml in BTS. The rates of formazan production were measured in 96-well microtiter plates immediately and 1h after incubation at $17^{\circ}C$ using a spectrophotometer at wave length 560 nm. Simultaneously, split samples of the same semen were tested, using eosin-nigrosin staining to compare the efficiency of the MTT assay of sperm viability in BTS. The correlation between the results of these tests was calculated using Student-t test and ANOVA. The results revealed a strong correlation between the results of MTT reduction rate and the results that were simultaneously determined by eosin-nigrosin staining at 1 h. In conclusion, the MTT reduction test was an effective and simple method to validate sperm viability and it could be used as a simple tool to evaluate sperm viability in the local A.I center and laboratory.
The objective of this study was to determine the effect of semen extenders on the motility, viability and fertility in vitro of spermatozoa during storage of fresh boar semen diluted in different commercial extenders used for pig artificial insemination (AI). In this experiment, semen were diluted in Androhep plus, Beltsville Thawing Solution (BTS), Modena, Seminark and Vitasem LD. Five ejaculates were collected from three Duroc boars and sub-samples were diluted ($30{\times}10^6$ spermatozoa/ml) in different extenders. Semen was stored at $170^{\circ}C$ for 10 days. Sperm motility and viability was assessed using Computer-Assisted Semen Analysis (CASA) and flow-cytometry on 1, 3, 5 and 10 day post collection The motility of spermatozoa stored in different extenders was gradually decreased by increasing the duration of storage of semen. However, there was not significant1y different in the sperm motility and viability among other extenders. On the other hand, the in vitro-matured oocytes were fertilized and cultured in vitro to assess the fertility of boar spermatozoa stored for 3 and 10 days in different extenders. The percentage of morula and blastocyst were taken as indicators of fertility in vitro of spermatozoa. Therefore, there were no differences in the rate of embryos developed to the molular and blastocyst stage. There were no differences in the motility and fertility in vitro among 5 kinds of commercial boar semen extenders.
Sa, Soo-Jin;Kim, In-Cheul;Choi, Sun-Ho;Hong, Joon-Ki;Kim, Du-Wan;Cho, Kyu-Ho;Kim, Young-Hwa;Chung, Ki-Hwa;Park, Jun-Cheol
한국수정란이식학회지
/
제28권4호
/
pp.349-353
/
2013
The objective of this study was to compare the effect of semen extenders on the sperm motility, viability, acrosome integrity and functional integrity of plasma membrane (HOST: hypo-osmotic swelling test) during liquid preservation of Korean Native boar semen. In this experiment, semen was diluted in Androhep plus, Beltsville Thawing Solution (BTS), ModenaTM, Seminark and Vitasem LD. Sperm-rich fractions were collected from three Korean Native boars and sub-samples were diluted ($30{\times}10^6$ spermatozoa/ml) in different semen extenders. Semen samples were stored at $17^{\circ}C$ for 96 hours. On everyday (0, 24, 48, 72, 96 h) after storage, the sperm characteristics relevant for fertility, such as sperm motility, viability, acrosome integrity and HOST positive were evaluated. The motility of spermatozoa stored in different extenders was no significantly different among other extenders (P>0.05). Also, no difference was observed among samples processed with different extenders in the percentage of sperm viability, acrosome integrity and HOST positive. All extenders maintained a high percentage (70%) of sperm motility, viability and acrosome integrity through 96 h of storage. The result of this study show that there was no significant differences among extenders in their capacity to preserve motility, viability and membrane integrity of spermatozoa from normal, fertile Korean Native boars for 96 h of liquid preservation at $17^{\circ}C$.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.