• Title/Summary/Keyword: Anatomical practice

Search Result 62, Processing Time 0.023 seconds

Image Superimposition for the Individual Identification Using Computer Vision System (컴퓨터 시각 인식 기법을 이용한 영상 중첩법에 의한 개인식별)

  • Ha-Jin Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.1
    • /
    • pp.37-54
    • /
    • 1996
  • In this thesis, a new superimposition scheme using a computer vision system was proposed with 7 pairs of skull and ante-mortem photographs, which were already identified through other tests and DNA fingerprints at the Korea National Institute of Scientific Investigation. At this computer vision system, an unidentified skull was caught by video-camcoder with the MPEG and a ante-mortem photograph was scanned by scanner. These two images were processed and superimposed using pixel processing. Recognition of the individual identification by anatomical references was performed on the two superimposed images. These results were as followings. 1. For the enhancement of skull and ante-mortem photographs, various image processing schemes, such as SMOOTH, SHARPEN, EMBOSS, MOSAIC, ENGRAVE, INVERT, NEON and COLOR TO MONO, were applied using 3*5 window processing. As an image processing result of these methods, the optimal techniques were NEON, INVERT and ENGRAVE for the edge detection of skull and ante-mortem photograph. 2. Using various superimposition image processing techniques (SRCOR, SRCAND, SRCINVERT, SRCERASE, DSTINVERT, MERGEPAINT) were compared for the enhancement of image recognition. 3. By means of the video camera, the skull image was inputed directly to a computer system : superimposing it on the ante-mortem photograph made the identification more precise and time-saving. As mentioned above, this image processing techniques for the superimposition of skull and ante-mortem photographs simply used the previous approach, In other wrods, taking skull photographs and developing it to the same size as the ante-mortem photographs. This system using various image processing techniques on computer screen, a more precise and time-saving superimposition technique could be able to be applied in the area of individual identification in forensic practice.

  • PDF

The Dosimetric evaluation of the standard electron cone for the extended cone for the extended SSD and The Dosimetric characteristics of the custom-made electron cone (표준 전자선 cone의 확장된 SSD에서의 선량평가 및 자체제작한 전자선 cone의 특성)

  • Chung Se Young;Chung Hui Young;Kim Young Bum;Kwon Young Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.73-78
    • /
    • 1999
  • In general, the patients of the head and neck cancer are treated with 4MV photon beam up to prescribed dose, but spinal cord should be excluded in the treatment field. When its absorbed dose is limited at the tolerance dose. In case of the patients who has the positive posterior neck nodes need a boost electron beam treatment to the prescribed dose. In that case, the anatomical structure of the neck and the physical structure of the standard electron cone interrupt to allow proper access to the disease site. Therefore, we extended treatment SSD for the remove of the those hindrances. In this study, we evaluated the dosimetric variation of the standard electron cone for the extended SSD, from 100cm to 120cm, 5 cm increment, and compare to the custom-made electron cone. As a result, the $\%$ depth dose, the point of maximum dose and the range of maximum were changed within the $2\%$. The penumbra width was increased from 1.0cm to 2.0cm. However, the dosimetric characteristics of the custom-made electron cone was very similar to that of the 100cm SSD standard electron cone and due to its characteristic of physical structure, patients didn't need re-positioning after photon beam treatment, therefore accurate treatment was possible, we conclude that the custom-made electron cone was very useful for the clinical practice.

  • PDF

Therapeutic Duplication Criteria Development of Respiratory System Drugs (호흡기계 작용 약물의 치료군 중복처방 평가기준 개발)

  • Choi, Kyung-Eob;Sohn, Hyun-Soon;Kim, Nam-Hyo;Shin, Hyun-Taek;Lee, Young-Sook
    • YAKHAK HOEJI
    • /
    • v.56 no.2
    • /
    • pp.126-135
    • /
    • 2012
  • Purpose: To develop therapeutic duplication criteria for the drugs used for respiratory diseases. Method: Therapeutic duplication was defined as "more than 2 drug ingredient-usage in which each has the same therapeutic effect and combination therapy does not confer additional therapeutic benefit". Respiratory system drugs approved in Korea were examined for the study. The WHO's Anatomical Therapeutic Chemical Classification System was used for grouping of the corresponding drug ingredients. The principles and recommendations on combination usage or multiple drug regimens were reviewed by using the clinical practice guidelines, textbooks, product labelings, and clinical articles. Clinical expert group consultation was performed and expert opinions were incorporated into the final criteria. Results: Nine hundred sixty two drug products with Korean Food and Drug Administration classification codes of 141, 149, 222, and 229 were evaluated, of which 87 active ingredients were composed. The drug ingredients were classified into 12 groups (antihistamines, oral nasal decongestants, leukotriene receptor antagonists, inhaled anticholinergics, inhaled corticosteroids, oral ${\beta}2$-agonists, long-acting ${\beta}2$-agonists, short-acting ${\beta}2$-agonists, xanthines, antiallergics, mucolytics and cough suppressants). The use of more than 2 drug ingredients including the same group was therapeutic duplication, and thus combination should be recommended not to be used. Conclusion: Twelve drug groups were identified as therapeutic duplication criteria. Combination therapy within each group should not be used otherwise therapeutic benefits outweigh potential risks.

Arthroscopic Findings of the Canine Stifle Joint (정상견 무릎의 관절경 검사소견)

  • 정순욱;정월순
    • Journal of Veterinary Clinics
    • /
    • v.16 no.2
    • /
    • pp.300-308
    • /
    • 1999
  • Arthroscopy is a valuable diagnostic and operative tool in equine and human orthopedics. The arthroscope is a difficult instrument to use and requires patience, practice, and persistence in order to obtain good results. This technique was found to be less traumatic than arthrotomy, invasiveness, rapid recovery and the feasibility of surgically correcting many arthropathies. The use of the arthroscope in the dog provides a new dimension in the study and diagnosis of joint derangements. The purpose of this report is to introduce the use of the arthroscope in the dog-more specifically, in the stifle of the dog. A diameter 2.7 mm fore-oblique viewing arthroscope, cold light source, video and video printer are used. With the fore-oblique viewing type it is possible to view directly as well as slightly to the side and the range of viewing can be increased by rotating the arthroscope around the object The scope is connected with a cold light source by means of a fiber-optic light guide. The stifle joint was flexed to 20~30$^{\circ}$. The joint were lavaged with lactated Ringer's solution during arthroscopic examination. Arthroscopy of the stifle was performed prior to arthrotomy in 1 dead dog and 4 healthy dogs, and other 3 dogs was performed only arthroscopic examination. In this study only the conventional approaches were used and in most cases it was possible to view all the intra-articular structures via the lateral infrapatellar approach. In the stifle joint, endoscopic observation was performed to find lateral femoral condyle, patella, medial femoral condyle, trochlear groove, tibia, fat, cranial cruciate ligament, caudal cruciate ligament lateral meniscus, tendon of long digital extensor muscle, medial meniscus, and medial collateral ligament Post-arthroscopic examination, the lameness had disappeared within 12~24 hours. Pain and swelling in the stifle joint had disappeared within 24~36 hours. Post-arthroscopic secondary infection was never encountered in the dogs. In conclusion, arthroscopic insertion technique in canine stifle joint using a diameter 2.7 mm 30$^{\circ}$ arthroscope was established and arthroscopical views of all anatomical structures in the normal stilfe joint were obtained through lateral infrapatellar portal.

  • PDF

Development of Drug Utilization Review Guidelines for Therapeutic Duplication of Antipyretics, Analgesics, and Anti-inflammatory Drugs Registered in Korea (국내 허가된 해열.진통.소염제의 치료중복 주의 가이드라인 개발)

  • Lee, Young-Sook;Kim, Nam-Hyo;Sohn, Hyun-Soon;Choi, Kyung-Eob;Shin, Hyun-Taek
    • Korean Journal of Clinical Pharmacy
    • /
    • v.20 no.3
    • /
    • pp.213-220
    • /
    • 2010
  • Therapeutic duplication (TD) is a serious problem that frequently occurring primarily in the ambulatory setting in Korea. Implementation of concurrent drug utilization review (DUR) is a promising way to reduce inappropriate prescription and dispensing, and improve patient safety. This study was aimed to develop the process of DUR module of TD. Sixty-five drug ingredients classified into the drug category of the antipyretic, analgesic, and anti-inflammatory drug approved in Korea (The KFDA-dess nated classification codes of 114 or 264) were reviewed for this purpose. The drug ingredients (and products) were reclassified based on WHO's Anatomical, Therapeutic and Chemical (ATC) classification system. The clinical practice guidelines, textbooks and product labels on therapeutic uses of these drugs in Korea and several fores n countries were reviewed. If the drugs were categorized into the same therapeutically duplicable class, they were defined not to be used concurrently because the concurrent use was "therapeutically duplicated (unnecessary or even harmful)". Among the studied drug products, the following 5 drug classes were considto beas "therapeutic duplication": (1), on-t tooid DURnti-inflammatory drugs (NSAIDs, including s Dicylates), (2),Anilidts, (3),Opioids, (4) Ergot Dk Doids and (5) 5-$HT_1$ receptor agonot s. Therefore, concurrent prescribing or dispensing of more than 2 drug ingredients any in the above same classes should be considered as TD and needed to be warrant for careful review by pharmacists before dispensing.

Breast augmentation surgery using an inframammary fold incision in Southeast Asian women: Patient-reported outcomes

  • Randquist, Charles;Por, Yong Chen;Yeow, Vincent;Maglambayan, Joy;Simonyi, Susan
    • Archives of Plastic Surgery
    • /
    • v.45 no.4
    • /
    • pp.367-374
    • /
    • 2018
  • Background This analysis presents patient-reported outcomes of breast augmentation procedures performed in Singapore using an inframammary fold incision and the "5 Ps" best practice principles for breast augmentation. These data are the first of their kind in Southeast Asian patients. Methods Through a retrospective chart review, patients who underwent primary breast augmentation with anatomical form-stable silicone gel breast implants using an inframammary fold incision were followed for ${\geq}6$ months postoperatively. The BREAST-Q Augmentation Module (scores standardized to 0 [worst] - 100 [best]) and Patient and Observer Scar Assessment Scale (POSAS; 1 [normal skin] to 10 [worst scar imaginable]) were administered. Responses were summarized using descriptive statistics. Patient-reported events were collected. Results Twenty-two Southeast Asian patients (mean age, 35.1 years) completed ${\geq}1$ postoperative BREAST-Q and POSAS assessment and were assessed 11 months to 5.5 years postoperatively. The mean postoperative BREAST-Q satisfaction with breasts and psychosocial well-being scores were 69.2 and 84.0, respectively. The mean POSAS score for their overall opinion of the scar was 4.2; the mean scores for all scar characteristics ranged from 1.2 to 4.2. Over 90% of patients (20/22) said that they would recommend the procedure. Patient complaints following surgery included anisomastia (possibly pre-existing; n=2), sensory loss at the nipple (n=2) or around the nipple (n=3), scarring (n=4), and slight capsular contracture (n=1). No patients required reoperation. Conclusions Southeast Asian patients reported high long-term satisfaction scores on the BREAST-Q scale and with their scar characteristics following breast augmentation using an inframammary fold incision, and nearly all said they would recommend this procedure. No reoperations were necessary in patients assessed for up to 5.5 years postoperatively.

A Study on Shu Points Selection of the Four Seas in Lingshu Hailun (『영추(靈樞)·해론(海論)』의 사해(四海) 수혈(輸穴) 선정에 대한 고찰)

  • Ahn, Jinhee
    • Journal of Korean Medical classics
    • /
    • v.33 no.2
    • /
    • pp.91-108
    • /
    • 2020
  • Objectives : To study the shu points selection of the Four Seas in the 「Hailun」 chapter of 『Lingshu』. Methods : The effects and main indications of each shu point, their anatomical position, characteristics along with similarities of disease patterns according to excessiveness and deficiency of the Four Seas were examined. Results : The selection of shu points of the Four Seas were deeply related to the effects and main indications, and the common similarity among conditions due to excessiveness and deficiency was the presence of psychological aspects. Also, when the Four Seas are connected to the Jing-Qi-Shen and Blood, marrow sea[髓海] is connected to Jing & Shen, qi sea[氣海] is connected to Qi, blood sea[血海] is connected to Blood, and sea of water and grain[水穀之海] replenishes Jing-Qi-Shen and Blood. When connected to the Four Qi Intersections, the marrow sea is connected to 'head qi with intersection', qi sea is connected to 'chest qi with intersection', sea of water and grain or blood sea is connected to 'stomach qi with intersection', otherwise sea of water and grain is connected to 'shin qi with intersection'. Conclusions : The Four Seas are designated to the shu points due to their accumulation of Qi when the main elements of Jing-Qi-Shen and Blood are deficient or excessive, allowing for the most convenient management and manipulation of the condition of these main elements. In clinical practice, the shu points of the Four Seas will likely increase treatment efficacy for conditions that include psychological aspects.

How to Use EVT Figures for Actor Voice Training I (배우 음성 훈련을 위한 EVT 구조연습 활용방안 I)

  • Lee, Young-Su
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.9
    • /
    • pp.136-148
    • /
    • 2021
  • In this study, the theoretical principle and structural practice of Estill Voice Training model that enables independent control of voice organs in the actor's acting art using voice as a medium of artistic expression. Its purpose is to explore the positive utility that can be applied to operation. The research on the speech science methodology that controls the differences in speech output due to the principle of the generation organ is a reality that has not been actively introduced in Korea compared to the existing actor's speech training that encompasses both the mind and the body. Voice can guarantee the accuracy and stability of operation when an understanding of our body is preceded based on anatomical physiology as well as contribute to the characterization of the character's phonetic character an element of character creation. Considering the training model through proprioception in actor voice training has practical value and alternative significance that the actor can be sought as a principle and practical methodology in the process of generating a series of target sounds.

Going Wilde: Prendick, Montgomery and Late-Victorian Homosexuality in The Island of Doctor Moreau

  • Canadas, Ivan
    • Journal of English Language & Literature
    • /
    • v.56 no.3
    • /
    • pp.461-485
    • /
    • 2010
  • The present paper focuses on a specific aspect of H. G. Wells' The Island of Doctor Moreau (1896), namely the issue of homosexuality, particularly as it concerns Prendick, the novel's primary narrator, and Montgomery, Moreau's assistant on the island, both of whom are implicitly associated with homosexual identity-and suggested to represent various forms of repression or acceptance-their personalities, or psyche, explored in relation to other characters on Moreau's island, particularly the Beast Folk, as well as Doctor Moreau and his treatment of the creatures as an allegory of Victorian anti-sodomy legislation and its most celebrated victim, Oscar Wilde, who had been convicted for male sodomy in 1895, only months prior to the original publication of The Island of Doctor Moreau. In addition, this paper examines an extensive series of allusions to Oscar Wilde and to late-Victorian homosexual scandals, including that author's own conviction, allusions to others involved in the affair-some of which involve situational/plot analogies, while others involve echoes or semantic associations between the names of characters in Moreau and historical figures-as well as allusions and parallels involving the most recognizably biographical of Wilde's works, The Picture of Dorian Gray (1890). The deliberate, complex web of allusions and ironic implications of homosexuality, presented in this essay, thus, expands considerably upon existing scholarly work on a range of matters concerning homosexual identity and conduct within the context of social conventions and legislation in the late-Victorian period, as well as more broadly, in scientific and humanistic terms. In this respect, one key aspect of this essay is the exploration of the novel's setting of Noble's Island, which, among other things, includes topographical allusions to nineteenth-century scientific theories of anatomical anomalies in pederasts-namely those of the eminent French forensic medical scientist, Ambroise Tardieu (1818-1879), whose underlying framework of physiological adaptation, moreover, intersected with the scientific interests of Wells and of his protagonist. Beyond this, it is shown that, in Moreau, there is as a web of allusions to homosexual practice and those same anomalies, involving the character of Montgomery and his name.

Magnetic Resonance Imaging and Ultrasonographic Evaluation of Canine Tarsus

  • Soomin Park;Sang-hwa Ryu;Jae-gwan Heo;Eun-jee Kim;Jihye Choi;Junghee Yoon
    • Journal of Veterinary Clinics
    • /
    • v.41 no.2
    • /
    • pp.79-87
    • /
    • 2024
  • The tarsus in dogs has a complex structure that makes its evaluation relatively challenging. Because an accurate diagnosis of the tarsus is difficult through basic examinations alone, imaging tests are essential. Previous studies have explored the anatomical and radiological features of the canine tarsus using several imaging modalities. However, the imaging utility of the tarsus across different modalities has not been thoroughly evaluated. This study aimed to visualize the tarsal structures using magnetic resonance imaging (MRI) and ultrasonography, compare their utility, and propose suitable imaging modalities and conditions for evaluating specific tarsal structures. Magnetic resonance imaging and ultrasound scans of the tarsus of four healthy dogs were performed, and two observers rated the utility of each image on a five-point scale. Although MRI is more beneficial for assessing the tarsal structures than ultrasound, ultrasound also appears clinically useful for evaluating the cranial tibialis muscle, deep digital flexor tendon, subcutaneous fat, joint space, and superficial digital flexor tendon. In addition, each structure of interest can be evaluated for optimal visibility using specific ultrasound sections, MRI sequences, and planes. In veterinary clinical practice, an initial assessment using ultrasound imaging with optimal visibility is required and if further evaluation is necessary, MRI examinations with optimal MRI sequences and planes can be performed.