• Title/Summary/Keyword: Analysis transient

Search Result 3,071, Processing Time 0.034 seconds

A Diesel Generator Model with Fluctuating Engine Torque Including Magnetic Saturation for Transient Analysis using XTAP

  • Sakamoto, Orie
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1298-1303
    • /
    • 2015
  • Diesel engine generators are widely used in the world, especially in remote site power systems as distributed generators. A weak distribution feeder with a small diesel engine may suffer from voltage and power fluctuations due to misfiring of the engine cylinder. In this study, new generator model with example engine torque was developed for the electromagnetic transient analysis program for power systems named XTAP. The configuration and verification results of the developed model are presented in the paper. The model is considered to be useful for analyses of small power systems with those diesel engines.

Evaluation of Twisting Deformation of the Door Frame of a Microwave Oven by Transient Response Analysis (과도응답 해석에 의한 전자레인지 도어 프레임의 비틀림 변형 평가)

  • Koo, Jin-Young;Lee, Boo-Youn
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.9 s.240
    • /
    • pp.1282-1288
    • /
    • 2005
  • This research has been motivated by the need to minimize possible leakage of microwave when one opens the door during operation of the microwave oven. An explicit finite element program is used to analyze the transient response the door of the oven under door-opening condition. Operation of the micro switch which plays an important role to hun off the power is simulated on the basis of the response of the latch. Using the results of the analysis, twisting deformation of the door frame is defined and evaluated.

Electric power system design and analysis for FLNG vessel

  • Lee, Geunbo;Jang, Jaehyeoung;Lyu, Sungkak;Yu, Jinyeol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.5
    • /
    • pp.573-580
    • /
    • 2014
  • The electrical reliability of the power generation and distribution system of Floating Liquefied Natural Gas vessels has been analyzed according to the operating modes using Electrical Transient Analysis Program in this paper. Electricity is used for the topside processes, cargo pumps for off-loading, thrusters for heading control and marine equipment. It is very important to improve the safety, efficiency, and stability of the electrical power system for successful operation. The voltage variation of the high and the low voltage bus shall be within the primitive limitation range at normal operation loads both in steady state and in the transient state. The power system was simulated and compared with class rule for design verification.

Transient Voltage Analysis of Low-Voltage Source Circuit inn Thermal Power Plant due to Grounding Potential Rise by Lightening (낙뢰침입에 의한 대지전위상승이 발전소 저압전원회로에 미치는 과전압 해석)

  • Yang, Byeong-Mo;Jeong, Jae-Kee;Min, Byeong-Wook;Lee, Jong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1644-1646
    • /
    • 1998
  • High-Smokestacks have been the symbol of the thermal power plant. Those cause the thermal power plant to be damaged by lightening for reaching several hundreds meter. In this paper, we investigated the accident of low-voltage source circuit due to grounding potential rise by lightening via high-smokestack in practically driving power plant, described examination into the cause and the impulse analysis. We analysed the transient voltage by EMTP(ElectroMagnetic Transient Program) via modeling the grounding system of power plant. This theoretical results coincided with practical accidental state. Therefore, it was verified that we could apply the grounding system of power plant and substation with the distribution-circuit analysis(EMTP).

  • PDF

Steady-State and Transient-State Electromagnetic Analysis of the 30 kVA Superconducting Generator (30 kVA 초전도 발전기의 정상상태 및 과도상태 전자계 해석)

  • Ha, Kyoung-Duck;Hwang, Don-Ha;Park, Doh-Young;Kim, Yong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.91-93
    • /
    • 1998
  • In this paper 30 kVA superconducting generator's transient-state electromagnetic analysis by FEM is described. The transient-state analysis by moving air gap technique was performed to analyze its 3 phase sudden short circuit characteristics. External circuit components were connected to generator model with end-winding resistance and inductance.

  • PDF

Transient Conjugate Heat Transfer of Turbine Rotor-Stator System

  • Okita, Yoji
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.831-838
    • /
    • 2004
  • A fluid-solid conjugate solver has been newly developed and applied to an actual engine disk system. Most of the currently available conjugate solvers lack the special thermal modeling for turbomachinery disk system applications. In the present new code, these special models are implemented to expand the applicability of the conjugate method and to reduce the required computational resources. Most of the conjugate analysis work so far are limited to the axisymmetric framework. However, the actual disk system includes several non-axisymmetric components which inevitably affect the local heat transfer phenomena. Also the previous work devoted to this area usually concentrate their efforts on the steady-state thermal field, although the one in the transient condition is more critical to the engine components. This paper presents full 3D conjugate analysis of a single stage high pressure turbine rotor-stator disk system to assess the three-dimensional effects (Fig. 1). The analysis is carried out not only in the steady-state but also in the engine accelerating transient condition. The predicted temperatures shows good agreement with measured data.

  • PDF

Interaction and Transient Analysis to FACTS Devices in Seoul Area (수도권 FACTS 상호영향 및 과도특성 분석)

  • Yoon, Jong-Su;Kim, Jae-Han;Lee, Seong-Doo;Choi, Jang-Hum;Seo, Bo-Hyeok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.11
    • /
    • pp.1929-1935
    • /
    • 2010
  • This paper describes the operation effect of FACTS devices in the Korean power system. At the year of 2010, three FACTS devices is under commercial operation in the Seoul area. Among them, 345kV ${\pm}100MVA$ STATCOM at Mi-Geum substation and 345kV ${\pm}200MVA$ SVC at Dong-Seoul substation are very close at their electrical and geographical distance. Therefore, the additional analysis including interaction and mutual transient is necessary. Therefore, a detailed EMTDC/PSCAD simulation model was developed and steady-state/transient analysis was implemented.

A Study on the Analysis of Lightning Damage Impact in Domestic Offshore Wind Farm (국내 해상풍력발전단지 낙뢰피해 영향 분석에 관한 연구)

  • Seo, Jin-Gyu;Kim, Kyu-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.2
    • /
    • pp.247-252
    • /
    • 2016
  • The latest offshore wind turbines are easily exposed to lightning strikes because they are designed with longer blades and taller height to satisfy the growing capacity demands. The generation facilities and elements of the offshore wind farm are more vulnerable to lightning damage because of more severe, unpredictable weather conditions. Therefore, this paper presents the analysis of measure for lightning overvoltage mitigation in offshore wind farm planned in South Korea southwest seashore. The sensitivity analysis includes the steady state and transient state characteristics of offshore wind farm and proposes the countermeasure for mitigation of transient overvoltage by considering earth resistivity of the offshore environment.

Transient Magnetic Analysis of AC Servo Motor Using FEM coupled with External Circuit Equation (외부회로 방정식과 유한요소법을 이용한 AC 서보전동기의 과도자계 해석)

  • Yeon, Jae-Wook;Kim, Young-Bong;Hwang, Eun-Sik;Shin, Pan-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.36-38
    • /
    • 1995
  • AC servo motors are widely used for various mechatronic devices such as FA, OA and robot machines. To obtain more accurate simulation results, a method of analysis for AC servo motor is described using transient magnetic formulation coupled with external circuit equation of the motor. The external circuit of the motor to be analyzed is described using FLUX2D program and linked to multiple finite element regions. The simulation results show that transient magnetic analysis coupled with extenal circuit has more accurate than those results from magnetostatic.

  • PDF

Analysis of Particle Collision on a Rotating Cantilever Beam Having a Concentrated Mass (집중 질량을 가진 회전하는 외팔 보의 질점 충돌 해석)

  • Lim, Hong-Seok;Yoo, Hong-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.714-714
    • /
    • 2005
  • This paper presents the modeling and impact analysis for a rotating cantilever beam having a concentrated mass. The concentrated mass takes an impact force during the rotating motion and the transient response of the beam induced by the impact is calculated by applying the Rayleigh-Ritz assumed mode method. The stiffness variation effect caused by the rotating motion is considered in this modeling. The effects of the concentrated mass size, impact position and the angular velocity of the beam on the transient responses are investigated through numerical studies.

  • PDF