• Title/Summary/Keyword: Analysis transient

Search Result 3,071, Processing Time 0.033 seconds

PREDICTING PARAMETERS OF TRANSIENT STORAGE ZONE MODEL FOR RIVER MIXING

  • Cheong, Tae-Sung;Seo, Il-Won
    • Water Engineering Research
    • /
    • v.4 no.2
    • /
    • pp.69-85
    • /
    • 2003
  • Previously developed empirical equations used to calculate the parameters of the transient storage model are analyzed in depth in order to evaluate their behavior in representing solute transport in the natural streams with storage zone. A comparative analysis of the existing theoretical and experimental equations used to predict parameters of the transient storage (TS) model is reported. New simplified equations for predicting 4 key parameters of the TS model using hydraulic data sets that are easily obtained in the natural streams are also developed. The weighted one-step Huber method, which is one of the nonlinear multi-regression methods, is applied to derive new parameters equation. These equations are proven to be superior in explaining mixing characteristics of natural streams with the transient storage zone more precisely than the other existing equations.

  • PDF

Evaluation of Transient Natural Circulation Behavior during Accident in Low Power /Shutdown Condition of YGN Units 3/4

  • Bang, Young-Seok;Kim, Kap;Seul, Kwang-Won;Kim, Hho-Jung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.458-463
    • /
    • 1997
  • A transient natural circulation behavior during a LOCA at hot-standby operation is evaluated for YGN Units 3/4. The plant initial condition is determined within the EOP limitation as suitable to hot-standby mode and the transient scenario is prepared as relevant to evaluation of transient natural circulation. A 0.4% cold leg break with loss of off-site power is calculated with RELAP5/MOD3.2, whose predictability has been verified for SBLOCA natural circulation test, S-NC-8B. Through one hour transient analysis, it is found that the plant has its own decay heat removal capability by natural circulation following a LOCA, at hot-standby mode. Additional calculation is performed to investigate an effect of HPSI flow on natural circulation.

  • PDF

A Study on the Electromagnetic Transients in A Power System (전력계통의 전자과도현상에 관한 연구)

  • 김경철;강창원;이일무
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.59-64
    • /
    • 2001
  • Transient in an electrical system are generated by lightning and switching. This paper presents analysis of switching and lightning surge, and means of limiting the voltage magnification transient for high voltage power systems by using EDSA's EMTAP software package. One means of limiting the voltage magnification transient is to convert the end-user power factor correction banks to harmonic filters. An inductance in series with the power factor correction bank was used to decrease the transient voltage at the customer bus to acceptable levees. The interception of the impulse from the phase wire is fairly straight forward by properly installed surge arresters. The simulation shows that the addition of the surge arrester at the customer location can achieve a substantial reduction of the transient magnitude.

  • PDF

A study on the Transient Torsional Vibrations of Four Stroke Marine Diesel Engines (선박용 4행정 디젤엔진의 과도 비틀림 진동에 관할 연구)

  • Lee, D.C.;Yu, J.D.;Jeon, H.J.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.44-50
    • /
    • 2002
  • Theoretical analysis on the transient torsional vibration was started from early 1960's for high power synchronous motor application. As for marine engineering, simulation and measuring techniques of transient torsional vibration have been steadily studied by manufacturer of flexible coupling and designer of four stroke marine diesel engine. In this paper, the simulation method of transient torsional vibration for four stroke marine diesel engine application using Newmark method is introduced.

  • PDF

Measurement and Analysis of Transient Overvoltages on Inverter-fed Induction Motors (인버터 구동 유도전동기에서 과도전압의 측정과 분석)

  • Park, Dae-Won;Kim, Il-Kwon;Choi, Su-Yeon;Park, Chan-Yong;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1445-1450
    • /
    • 2007
  • Induction motors are the main driving force of electric vehicles and operated by pulse width modulation (PWM) inverters in speed control. Contrary to full-voltage operation of induction motors, inverter-fed induction motors (IFM) generates transient overvoltages up to 10 kV/us and transient overvoltages accelerate the deterioration of winding insulation. We investigated transient overvoltages produced by the operation of IFM and analyzed its peak value and dv/dt depending on power cable length and operation frequency. The experimental results showed that transient overvoltages measured at the motor terminal increased with the cable length between inverter and motor.

  • PDF

Analysis of Common Grounding Effect during the Transient State in Underground Transmission and Distribution Systems (지중송배전계통에서 과도상태시 공통접지의 영향 분석)

  • Lim, Kwang-Sik;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.191-197
    • /
    • 2008
  • This paper describes the effect of transient state in underground transmission and distribution lines installed together in the same tunnel. Two systems installed in the same tunnel are operated by the common grounding. This paper analyzed that how much one of the two kinds of systems influences the other systems during the transient state by EMTP/ATPDraw. Single line-to-ground fault and lightning surge were selected in transient state condition. These cases were simulated variously according to the variation of common grounding magnitude, fault location and lightning surge magnitude. It is evaluated that the analyzed results will be used for establishment and operating materials of common grounding in the same tunnel.

Analysis of Transient Features in Speech Signal by Estimating the Short-term Energy and Inflection points (변곡점 및 단구간 에너지평가에 의한 음성의 천이구간 특징분석)

  • Choi, I.H.;Jang, S.K.;Cha, T.H.;Choi, U.S.;Kim, C.S.
    • Speech Sciences
    • /
    • v.3
    • /
    • pp.156-166
    • /
    • 1998
  • In this paper, I would like to propose a dividing method by estimating the inflection points and the average magnitude energy in speech signals. The method proposed in this paper gave not only a satisfactory solution for the problems on dividing method by zero-crossing rate, but could estimate the feature of the transient period after dividing the starting point and transient period in speech signals before steady state. In the results of the experiment carried out with monosyllabic speech, it was found that even through speech samples indicated in D.C. level, the staring and ending point of the speech signals were exactly divided by the method. In addition to the results, I could compare with the features, such as the length of transient period, the short term energy, the frequency characteristics, in each speech signal.

  • PDF

Numerical Analysis on the Transient Cooling Characteristics of an Infrared Detector Cryochamber (적외선 센서 냉각용 극저온 용기의 과도 냉각 특성에 관한 수치해석)

  • 이정훈;김호영;강병하
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.2
    • /
    • pp.68-72
    • /
    • 2002
  • This work investigates the transient cooling characteristics of an Infrared (IR) detector cryochamber, which has a critical effect on the cooling load. The current thermal modeling considers the conduction heat transfer through a cold well. the gaseous conduction due to outgassing. and the radiation heat transfer. The transient cooling Performance. i.e. the penetration depth and cooling load, is determined using a finite difference method. It is found that the penetration depth increases as the bore conductivity increases. Gaseous conduction and radiation hardly affect the penetration depth. The transient cooling load increases as the bore conductivity increases. The effects of gaseous conduction and radiation on transient heat transfer are weak at initial stages of cooling. However, their effects become significant as the cooling Process Proceeds.

A Study of the Transient Effect at the Thulium-doped Optical Fiber Amplifier (Thulium이 도핑된 광섬유 증폭기의 과도현상에 관한 연구)

  • 이재명;이영우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.349-352
    • /
    • 2001
  • The transient response in TDFA(Thulium-Doped Fiber Amplifier) is theoretically investigated. The TDFA has the spectral gain band in 1.47 ${\mu}{\textrm}{m}$. The transient model includes the transient buildup of the population inversion, the pump power, the signal power and their transient variation along the fiber amplifier. The results of numerical analysis can predict the gain saturation and recovery time at the fiber amplifier. It also shows the gain saturation and recovery effect depending on the pumping and saturation rate.

  • PDF

PZTN Sintered at the Low Temperature by the Glass Phase Transient Processing (글래스 천이 공정에 의해 저온소결된 PZTN)

  • Kim Chan Young
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.3
    • /
    • pp.97-102
    • /
    • 2005
  • This research was a fundamental study for the low temperature sintering of PZTN by glass phase transient processing. To lower the sintering temperature, the glass phase Processing was used. Also to improve the electrical properties, the transient processing was utilized. After characterization, the various analytic techniques, such as Archimedes method for the measuring densification, x-ray diffraction patterns for the quantitative analysis of crystalline phases were utilized. Also the dielectric constant, dissipation factor, and piezoelectric coefficients were measured to evaluate the PZTN sintered at the $950^{\circ}C$ and $1050^{\circ}C$. This was confirmed that the sintering temperature of PZTN was reduced by $950^{\circ}C$ and the electrical properties were improved by the transition processing. Therefore, the glass phase transient processing can be applicable to low the sintering temperature with the dielectric and piezoelectric properties.