• Title/Summary/Keyword: Analysis of variance

Search Result 6,181, Processing Time 0.04 seconds

Optimization for the Physical Properties of Steamed Foam Cakes Prepared with Single-stage Method by Response Surface Methodology (반응표면 분석법에 의한 단단계법 거품형 찜 케이크의 물리적 특성의 최적화)

  • Kwhak, Sung-Ho;Jang, Myung-Sook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.4
    • /
    • pp.557-566
    • /
    • 2005
  • In preparation of steamed foam-cakes, effects of whipping time, amount of wheat flour, and amounts of emulsifier on physical properties of the steamed foam cakes were investigated using RSM (response surface methodology). The three independent variables selected for the RSM experiment were whipping time $(X_1)$, amount of wheat flour $(X_2)$, and amounts of wheat flour $(X_2)$, and concentration of emulsifier $(X_3)$ were set for single-stage mixing, respectively. A rotatable central composite design was used for treatment arrangement. The responses from the product for loaf volume, color values and textural properties were analysed. In the analysis of variance for the foam cakes prepared by single-stage method, significant interactions were observed between independent variables (experimental factors) and physical property like loaf volume (p<0.05); textural properties like hardness, gumminess, and chewiness (p<0.05). Among independent variables, concentration of emulsifier had the most effects on physical properties while whipping time. The ordinary points in surface response showed maximal points with physical property like colorimetric b value while other properties revealed saddle points. The 3-dimensional response surface graphs of the predicted regression models displayed decreasing loaf volumes with increasing whipping times and emulsifier concentrations beyond optimum levels. The optimum conditions for best loaf volume and textural property (hardness, gummimess and chewiness) of the products selected by extracting intersectional areas of the contour maps that commonly overlapped all characteristics were; $11\~13$ min whipping time, $470\~486\;g$ amount of wheat flour, and $19\~20\;g$ emulsifier concentration, in case of single-stage method. The median values extracted from the RSM experimental results for optimum manufacturing conditions for single-stage method, i.e., 12 min whipping time, 478 g amount of wheat flour, and 20 g emulsifier concentration were empirically proven to fit the predicted levels of physical properties from the final foam cakes.

Development of nutrition quotient for elementary school children to evaluate dietary quality and eating behaviors (학령기 아동 대상 영양지수 개발과 타당도 검증)

  • Lee, Jung-Sug;Hwang, Ji-Yun;Kwon, Sehyug;Chung, Hae-Rang;Kwak, Tong-Kyung;Kang, Myung-Hee;Choi, Young-Sun;Kim, Hye-Young
    • Journal of Nutrition and Health
    • /
    • v.53 no.6
    • /
    • pp.629-647
    • /
    • 2020
  • Purpose: This study was undertaken to develop a nutrition quotient for elementary school children (NQ-C) for evaluating the overall dietary quality and eating behaviors. Methods: The NQ-C was developed by implementing 3 stages: item generation, item reduction, and validation. Candidate food behavior checklist (FBC) items of the NQ-C were derived from systematic literature reviews, expert in-depth interviews, statistical analyses of the fifth Korean National Health and Nutrition Examination Survey data, and national nutrition policies and recommendations. For the pilot survey, 260 elementary school students (128 second graders and 132 fifth graders) completed self-administered questionnaires as well as 24-hour dietary intakes, with the help of their parents and survey team staff, if required. Based on the pilot survey results, expert reviews, and priorities of national nutrition policy and recommendations, checklist items were reduced from 41 to 24. A total of 20 items for NQ-C were finally selected from results generated from 1,144 nationwide samples surveyed. Construct validity of the NQ-C was assessed using the confirmatory factor analysis, LInear Structural RELations. Results: Analyses of the exploratory factors of NQ-C identified that 5 dimensions of diet (balance, diversity, moderation, practice and environment) accounted for 46.2% of the total variance. Standardized path coefficients were used as weights of the items. The NQ-C and 5-factor scores of the subjects were calculated using the obtained weights of the FBC items. Conclusion: Our data indicates that NQ-C is a useful and suitable instrument for assessing nutrition adequacy, dietary quality, and eating behaviors of Korean elementary school children.

Analysis of Anatomical Conformity of Straight Antegrade Humeral Intramedullary Nail in Korean (한국인에서의 직선형 전향적 상완골 골수 내 금속정의 해부학적 적합성 분석)

  • Choi, Sung;Jee, Seungmin;Hwang, Seongmun;Shin, Dongju
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.498-503
    • /
    • 2021
  • Purpose: The aim of this study were to find ideal entry point of straight antegrade humeral intramedullary nail (SAHN) for the treatment of proximal humerus fracture in Korean and to analyze anatomical conformity using computed tomography. Materials and Methods: From May 2014 to October 2016, the study was conducted retrospectively on 74 Korean patients who had taken computed tomography on both normal and affected shoulder joint as result of shoulder injury. The mean age of the patients was 64.5 years (range, 22-95 years). Radiologic evaluation was done using multiplanar reconstruction technique of the computer tomography on normal proximal humerus. We located ideal entry point of SAHN as the point where humerus intramedullary center axis and humeral head meet. Distance between the entry point and local anatomical landmark was measured. We defined the critical distance as the distance between entry point and the most medial point of the supraspinatus attachment site. For adequate fixation and avoidance of injury to rotator cuff, critical distance should be over 8 mm according to Euler, and we defined the critical type when it is less than 8 mm. Critical distance, sex, age, height, body weight, body mass index was evaluated for the statistical significance. Results: The ideal entry point was as follows: the mean anteroposterior distance, the sagittal distance to the lateral margin of bicipital groove, was 11.5 mm and the mean mediolateral distance, the coronal distance to the lateral margin of grater tuberosity, was 20.5 mm. The mean critical distance, distance from the entry point to the just medial to insertion of the supraspinatus tendon, was 8.0 mm. Critical type with critical distance less than 8 mm was found in 41 in 74 patients (55.4%). Conclusion: The ideal entry point of SAHN in Korean was located on 11.5 mm posteriorly from the lateral margin of bicipital groove and 20.5 mm medially from lateral margin of greater tuberosity. More than half of the cases were critical type. Since critical type can possibly cause rotate cuff injury during nail insertion on entry point, surgeon should consider anatomical variance before choosing surgical option.

A Study of the Relationship of Nurses' Personality Type and Job Satisfaction Level, according to the Career (근무경력별 간호사의 성격유형과 직무만족도와의 관련성(MBTI이용))

  • Park Young Sook;Park Kyung Min;Park Jeong Sook;Koh Hyo Jung;Kwon Young Sook;Kim Myung Ae;Kim Chung Nam;Park Cheong Ja;Shin Yeong Hee;Lee Kyung Hee;Lee Byung Sook
    • Journal of Korean Public Health Nursing
    • /
    • v.15 no.2
    • /
    • pp.301-313
    • /
    • 2001
  • This study was to explore the relationship between nurses' personality type and their job satisfaction level. The subjects of the study were the 364 nurses who were serving at the general surgical department, psychiatric department, pediatric department and emergency room. The hospitals for which they were working were four university hospitals in Daegu and Busan, and six other university hospitals in Seoul were selected as sample hospitals. For data collection, questionnaires were self-reported to the subjects, under their agreement, from May to June, 2000. The following two instruments were used in the study: One was MBTI Test whose Korean version designed and verified to reliability and validity by Kim Jung Taek and Shim Hae Sook(1990): the other was the Nursing Job Satisfaction Instrument, 'The Index of Work Satisfaction' developed by Slavitt, et al.., (1978). The data were analyzed by frequency, t-test, one-way variance analysis, scheffe's post hoc contrast, and Pearson correlation coefficient with SPSS Win 10.0 program. The results this study were as follows ; 1. As a result of testing nurse's personality type by function at each career, it's found that the most personality type was expressed by the ST-type$(37.3\%)$ at 1-5 years, the SF-type$(29.4\%)$ at 6-10 years, the ST-type$(43.3\%)$ at more than 11 years. 2. As a result of testing the disparity in job satisfaction according to career, it appeared that the 6-10 years group showed higher job satisfaction, followed by the 6-10 years$(119.6\%),\;1-5 years(118.6\%)\;and\;more\;than\; 11 years(117.7\%)$ groups. 3. As a result of testing job satisfaction level according to nurse's personality type by function at each career, it's found that the most job satisfaction was expressed by the SF-type(F=8.50, p=0.00l) at 1-5 years. the ST-type(F=30.61, p=0.001) at 6-10 years. the SF-type(F=4.98, p=0.003) at more than 11 years groups. 4. As a result of testing a significant correlation between nurse's personality type by function and job satisfaction level. the SF(r=0.279, p=0.001) and ST(r=0.222, p=0.001) types showed significant positive correlation. and the NF(r=-0.201, p=0.001) and NT(r=-0.402, p=0.001) types revealed significant negative correlation. The nursing management is likely to be done more effectively, if managers in charge of nursing administration carefully reflect nurses' personal opinions in posting and personnel management, keeping in mind that there is a specific personality type that serves to raise job satisfaction at a specific career.

  • PDF

The marginal fidelity of $Procera^{(R)}$ AllCeram alumina copings and crowns of patients ($Procera^{(R)}$ AllCeram 을 이용한 도재관의 임상적 변연적합도에 관한 연구)

  • Song, Young-Gyun;Cho, In-Ho;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.470-478
    • /
    • 2008
  • Statement of problem: Use of all-ceramic prostheses fabricated with CAD/CAM systems is increasing in the dentistry. Marginal fidelity in production of all-ceramic restoration has important clinical implications and is a key consideration issue in CAD/CAM production as well. Purpose: The objective of this study was to analyse marginal fidelities of $Procera^{(R)}$ Allceram Crown. Material and methods: On 56 patients treated with $Procera^{(R)}$ system Allceram Crown at Dankook Dental Hospital, marginal discrepancies of 101 abutments were measured by stereomicroscope at coping and final restoration stages. Paired t-test and one-way analysis of variance on marginal discrepancy data were conducted to determine the presence of significant differences between measurement and measuring point stages. Results: Marginal discrepancies of final restoration ($45.82{\pm}30.84\;{\mu}m$) were lower than alumina coping ($53.84{\pm}38.83\;{\mu}m$). Furthermore, the differences were found to be statistically significant at 95% confidence level. Anterior marginal discrepancies were lower than posterior marginal discrepancies, but they were not statistically significant. Lingual marginal discrepancies were higher than other measurement sites, and the differences were found to be statistically significant at 95% confidence level. Conclusion: Within the conditions of this study, marginal fidelities of $Procera^{(R)}$ Allceram Crown were acceptable, and after porcelain build-up, marginal fitness improved over alumina coping. More careful scanning is needed for better results.

Functional Brain Mapping Using $H_2^{15}O$ Positron Emission Tomography ( I ): Statistical Parametric Mapping Method ($H_2^{15}O$ 양전자단층촬영술을 이용한 뇌기능 지도 작성(I): 통계적 파라메터 지도작성법)

  • Lee, Dong-Soo;Lee, Jae-Sung;Kim, Kyeong-Min;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.225-237
    • /
    • 1998
  • Purpose: We investigated the statistical methods to compose the functional brain map of human working memory and the principal factors that have an effect on the methods for localization. Materials and Methods: Repeated PET scans with successive four tasks, which consist of one control and three different activation tasks, were performed on six right-handed normal volunteers for 2 minutes after bolus injections of 925 MBq $H_2^{15}O$ at the intervals of 30 minutes. Image data were analyzed using SPM96 (Statistical Parametric Mapping) implemented with Matlab (Mathworks Inc., U.S.A.). Images from the same subject were spatially registered and were normalized using linear and nonlinear transformation methods. Significant difference between control and each activation state was estimated at every voxel based on the general linear model. Differences of global counts were removed using analysis of covariance (ANCOVA) with global activity as covariate. Using the mean and variance for each condition which was adjusted using ANCOVA, t-statistics was performed on every voxel To interpret the results more easily, t-values were transformed to the standard Gaussian distribution (Z-score). Results: All the subjects carried out the activation and control tests successfully. Average rate of correct answers was 95%. The numbers of activated blobs were 4 for verbal memory I, 9 for verbal memory II, 9 for visual memory, and 6 for conjunctive activation of these three tasks. The verbal working memory activates predominantly left-sided structures, and the visual memory activates the right hemisphere. Conclusion: We conclude that rCBF PET imaging and statistical parametric mapping method were useful in the localization of the brain regions for verbal and visual working memory.

  • PDF

A Study on the Influence of Finishing and Polishing Methods on the Gap between Denture Base Resin and Soft Liner (의치의 마무리와 연마법이 의치상 레진과 연성 이장재 간의 공극에 미치는 영향에 관한 연구)

  • Jung, Seung-Hwan;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.325-335
    • /
    • 2008
  • The junction between resilient denture liner and the denture base is difficult to finish and polish due to difference of the physical property of the materials. Gaps tend to be formed during finishing and polishing procedures. The purpose of this study was measuring the width of junctional gap between $Molloplast-B^{(R)}$ and denture base material after finishing and polishing procedure, and evaluating the effect of method and direction on gap width. $Molloplast-B^{(R)}$ was processed (according to the manufacturer's instruction) against Lucitone $199^{(R)}$ acrylic resin. 50 specimens were fabricated with a raised center section. All of specimens were examined and photographed with a stereoscopic microscope(x120), and the largest gap along the junction of $Molloplast-B^{(R)}$ and acrylic resin on each specimen was measured. One-way analysis of variance(ANOVA) and independent t-test at 95% confidence level were used to analyze the data and to compare groups. The results of this study were as follows. In comparison with finishing tools, the gap width was the largest in $Molloplast^{(R)}$-Cutter and the smallest in FSQ-cross cut bur. There was statistically significant difference between FSQ-cross cut bur and $Molloplast^{(R)}$-Cutter(p<0.05). There was no significant difference in gap width between the direction of polishing. The mean value of gap width was the smallest in case of no polishing, and the largest in case of polishing with pumice & tin oxide. There was statistically significant difference between pumice and pumice & tin oxide. From the results, it is concluded that the use of $Molloplast^{(R)}$-Cutter in clinic need serious consideration even though it has good cutting ability. Further careful study is needed for finishing and polishing methods for decreasing gap width in junction of two materials.

Performance Characteristics of PM10 and PM2.5 Samplers with an Advanced Chamber System (챔버 기술 개발을 통한 PM10과 PM2.5 시료채취기의 수행 특성)

  • Kim, Do-Hyeon;Kim, Seon-Hong;Kim, Ji-Hoon;Cho, Seung-Yeon;Park, Ju-Myon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.8
    • /
    • pp.739-746
    • /
    • 2010
  • The purposes of this study are 1) to develop an advanced chamber system within ${\pm}10%$ of air velocity at the particulate matter (PM) collection area, 2) to research theoretical characteristics of PM10 and PM2.5 samplers, 3) to assess the performance characteristics of PM10 and PM2.5 samplers through chamber experiments. The total six one-hour experiments were conducted using the cornstarch with an mass median aerodynamic diameter (MMAD) of $20\;{\mu}m$ and an geometric standard deviation of 2.0 at the two different air velocity conditions of 0.67 m/s and 2.15 m/s in the chamber. The aerosol samplers used in the present study are one APM PM10 and one PM2.5 samplers accordance with the US federal reference methods and specially designed three mini-volume aerosol samplers (two for PM10 and one for PM2.5). The overall results indicate that PM10 and PM2.5 mini-volume samplers need correction factors of 0.25 and 0.39 respectively when APM PM samplers considered as reference samplers and there is significant difference between two mini-volume aerosol samplers when a two-way analysis of variance is tested using the measured PM10 mass concentrations. The PM10 and PM2.5 samplers with the cutpoints and slopes (PM10: $10{\pm}0.5\;{\mu}m$ and $1.5{\pm}0.1$, PM2.5: $2.5{\pm}0.2\;{\mu}m$ and $1.3{\pm}0.03$) theoretically collect the ranges of 86~114% and 64~152% considering the cornstarch characteristics used in this research. Furthermore, the calculated mass concentrations of PM samplers are higher than the ideal mass concentrations when the airborne MMADs for the cornstarch used are smaller than the cutpoints of PM samplers and the PM samplers collected less PM in another case. The chamber experiment also showed that PM10 and PM2.5 samplers had the bigger collection ranges of 37~158% and 55~149% than the theocratical calculated mass concentration ranges and the relatively similar mass concentration ranges were measured at the air velocity of 2.15 m/s comparing with the 0.67 m/s.

Comparative evaluation of marginal and internal fit of metal copings fabricated by various CAD/CAM methods (다양한 CAD/CAM 방식으로 제작한 금속하부구조물 간의 변연 및 내면 적합도 비교 연구)

  • Jeong, Seung-Jin;Cho, Hye-Won;Jung, Ji-Hye;Kim, Jeong-Mi;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.211-218
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the accuracy of four different metal copings fabricated by CAD/CAM technology and to evaluate clinical effectiveness. Materials and methods: Composite resin tooth of the maxillary central incisor was prepared for a metal ceramic crown and duplicated metal die was fabricated. Then scan the metal die for 12 times to obtain STL files using a confocal microscopy type oral scanner. Metal copings with a thickness of 0.5 mm and a cement space of $50{\mu}m$ were designed on a CAD program. The Co-Cr metal copings were fabricated by the following four methods: Wax pattern milling & Casting (WM), Resin pattern 3D Printing & casting (RP), Milling & Sintering (MS), Selective laser melting (SLM). Silicone replica technique was used to measure marginal and internal discrepancies. The data was statistically analyzed with One-way analysis of variance and appropriate post hoc test (Scheffe test) (${\alpha}=.05$). Results: Mean marginal discrepancy was significantly smaller in the Group WM ($27.66{\pm}9.85{\mu}m$) and Group MS ($28.88{\pm}10.13{\mu}m$) than in the Group RP ($38.09{\pm}11.14{\mu}m$). Mean cervical discrepancy was significantly smaller in the Group MS than in the Group RP. Mean axial discrepancy was significantly smaller in the Group WM and Group MS then in the Group RP and Group SLM. Mean incisal discrepancies was significantly smaller in the Group RP than in all other groups. Conclusion: The marginal and axial discrepancies of the Co-Cr coping fabricated by the Wax pattern milling and Milling/Sintering method were better than those of the other groups. The marginal, cervical and axial fit of Co-Cr copings in all groups are within a clinically acceptable range.

The Effects of Monoamine Oxidase A CA Repeat Polymorphism on Behavioral Trait and Clinical Characteristics in Korean Male Alcoholics (단가아민 산화제 A CA 반복 유전자 다형성이 한국 알코올의존 남자환자의 행동특성과 임상양상에 미치는 영향)

  • Lee, Jung-Sik;Yang, Byung-Hwan;Lee, Kyung-Mee;Kim, Hong-Kwan;Kim, Yong-In;Chai, Young-Gyu
    • Korean Journal of Biological Psychiatry
    • /
    • v.7 no.1
    • /
    • pp.64-73
    • /
    • 2000
  • There are several candidate genes in genetic study of alcoholism. Among them, allelic associations have been reported between MAOA CA repeat polymorphism and alcohol dependence, recently. And also, several studies have been investigated genotype-phenotype relationships between MAOA CA repeat polymorphism and clinical manifestations. The authors tried to identify differences in allelic frequency of MAOA CA repeat polymorphism between alcohol dependence and controls, and in behavioral trait and clinical characteristics according to MAOA CA repeat polymorphism. We also tried to investigate genotype-phenotype relationships between MAOA CA repeat polymorphism and behavioral trait such as aggression. We examined 49 male patients with alcohol dependence(DSM-IV) who had been admitted in Yong-In Mental Hospital from June 1st 1998 to October 31th 1998. We performed semistructured interview for demographic and clinical characteristics. Self-report questionnaire for BDHI(Buss-Durkey Hostility Inventory) was given to all subject at least 4weeks later after admission. Using polymerase chain reaction and polyacrylamide gel electrophoresis, MAOA CA repeat polymorphism were observed in 52 male controls and 49 male patients with alcohol dependence. We devided alcoholic patients into two groups according to allelic length of MAOA CA repeat polymorphism ; alcoholics with short alleles(${\leq}$119bp, N=20) and alcoholics with long alleles(${\geq}$123bp, N=29). T-test, ${\chi}^2$-test and Fisher exact probability test were used for statistical analysis. There were no significant differences in frequency of each allele and short and long alleles of MAOA CA repeat polymorphism between alcoholics and controls. But there were significant differences in clinical symptoms and behavioral trait between alcoholics with short and long alleles. In clinical symptoms, alcoholics with long alleles used alcohol more frequently during one month before admission, had much more maximum amount of beer drinking and reported withdrawal seizure more frequently than with short alleles. In contrary, alcoholics with short alleles expressed depressed mood and guilty feeling more frequently and wanted complete abstinence as a treatment goal more frequently than with long alleles. In behavioral trait, alcoholics with long alleles had higher total aggression score and showed much more self-assertive attitude(subscale of expression of aggression) than with short alleles. Allelic length of MAOA CA repeat polymorphism was correlated with self-assertive attitude and accounted for 9% of the variance of self-assertive attitude. And also, predictable variables of allelic length of MAOA CA repeat polymorphism were drinking frequency and self-assertive attitude. Our findings suggest that MAOA CA repeat polymorphism may provide some behavior modifying role especially in self-assertive attitude and indirect symptom modifying role in Korean male alcoholics.

  • PDF