• Title/Summary/Keyword: Analysis of Installation Status

Search Result 123, Processing Time 0.026 seconds

Analysis of Effect of Designated New Technology of Electric Power on the Electrical Construction Industries (전력신기술 제도가 전기공사업계에 미치는 영향 분석)

  • Hwang, Min-Soo;Jeon, Tae-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.2
    • /
    • pp.106-113
    • /
    • 2012
  • Recently laws have been enacted to build and promote the use of smart grid. There are also increasing demands for the compliance with international trade agreements and the related international standards. Due to these rapid changes in electric power industry and the market expansion, importances of new technologies and processes have been being increased. To reflect these international trends, the government have carried out the designation of new technology for electric power industry to promote domestic industries and national competitiveness by inspiring technology developments in individual or private industry sectors. In this paper analysis of the current status of the designation of the new technology of electric power has been presented including its problem and effect on the related industries. The analysis is expected to be utilized to enhance sound development and to vitalize the electrical new technology regulation.

A Study on the Current Status and Analysis on the Problem of Unfloored space and Floor Repair in Rural House (농촌주택의 봉당·마루 개보수 현황 및 문제점 분석)

  • Park, Gil-Beom;Park, Jun-Mo;Kim, Ok-Kyue
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.117-118
    • /
    • 2014
  • The unfloored space and floor is one of characteristic of traditional house in Korea. This space is used to connecting passage between room or entrance of house. Currently, according to decline of heat insulation property thereby becoming decrepit house, native is repairing it for block external environment such as rain, wind and so on. But, variety problem is happening from wrong repair. This object of this study is current status and analysis on problem of unfloored space and floor repair. As a result, current status of repair is classified repair type, installation position and using form. And position of problem is confirmed connection between original house and extend space.

  • PDF

The Supply Status Analysis of New Renewable Energy Based on Public Obligation System (공공의무화 제도에 따른 신재생에너지 보급 실태 분석)

  • Seo, Sang-Hyun;Lee, Yong-Ho;Kim, Hyung-Jin;Cho, Young-Hum;Hwang, Jung-Ha
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.220-225
    • /
    • 2011
  • Based on the supply status statistics of new renewable energy according to public obligation system, current status of overall application centered on solar heat, solar ray, and geothermal heat as energy sources that can be applied to buildings may be analyzed as follows. (1) After the public obligation system, the investment costs on the total construction costs by years were between 5.21% and 7.12%: they were 7.12% in 2004, where the system was initially implemented; and they were gradually declined from 2005 to 2011, 5.76% in average. The ratio of equipment investment per energy sources in the total construction costs was 5.9%, which was slightly more than the obliged ratio. The order of investment costs per energy source was solar ray, geothermal heat, and solar heat. (2) Among the 1,433 sites in the plan of new renewable energy installation based on the public obligation system, "for cultural & social use" was most in target institution, and facilities for education & research was most in use classification, followed by public working, culture & rally, and sports. The number of facilities applied according to the case for planning installation per use classification of the target institution was between 1.1 and 1.5, or 1.4 in average of energy source. Conclusively, the authors of this study investigated overall current status of new renewable energy supply from the analysis of statistic data, and it may be needed of further supplementation of various examinations by visiting investigation and interviews with practitioners based on classification of use of target institutions.

  • PDF

Status Analysis and Activating Plan of Home Network for the Elderly (고령자를 위한 홈네트워크 현황 분석 및 활성화방안 수립 연구)

  • Kee, Ho-Young;Cheong, So-Yi
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.10
    • /
    • pp.125-132
    • /
    • 2011
  • The home network, contributing to improve the quality of life in dwelling, has expanded its installation and use in past years, but the elderly care system supporting self-reliance is not fully prepared. Although the aging society in Korea is progressing rapidly, inducting and spreading home network system is still required supporting of 'Aging in Place' for the elderly. This research is based the survey of spatial characteristics of housing of the elderly. Also, the research studied the technical level and policy of home network in domestic and abroad and analyze the professional view of experts in the home network field, as a result, suggested methods of building and activating the home network system.

A Study on the Management Plan through Performance Maintenance Analysis of Explosion-proof Facilities (방폭설비 성능유지 실태분석을 통한 관리방안 연구)

  • Kwon, Yong Jun;Byeon, Junghwan
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.2
    • /
    • pp.8-16
    • /
    • 2020
  • In Article 311 of the Regulation on Occupational Safety and Health Standards requires the use of Korean Industrial Standards Act in accordance with the Industrial Standardization Act. However, the classification, inspection, maintenance, design, selection, and installation of explosion hazard locations for explosion and explosion prevention and internalization of 'safety' in the performance maintenance phase of electrical machinery and equipment There is no technical and institutional management plan for remodeling and alteration. Analysis of actual conditions and problems related to the installation, use, and maintenance of explosion-proof equipment, comparative analysis of domestic and international technical standards and systems, technical, institutional and administrative systems and systems related to installation, use, and maintenance of explosion-proof equipment, technical personnel and qualifications, etc. It is to propose legislation, system improvement, and technical standard establishment related to the maintenance of explosion-proof facility performance through improvement of the necessity and feasibility study for establishment of the legal status of the management site and management plan. As technical measures, KS standard revision (draft), KOSHA guide (draft) and explosion-proof facility performance maintenance manual were presented. In addition, the institutional management plan proposed the revised rule on occupational safety and health standards, the revised rule on the restriction of employment of hazardous work, and the manpower training program related to the maintenance of explosion-proof facilities and the qualification plan. Enhance safety at the installation, use, and maintenance stage of explosion-proof structured electrical machinery. It is expected to be used to classify explosion hazards, select related equipment, and to update and standardize standards related to installation, use and maintenance.

Analysis of standby power for enhancing the energy efficiency of a hotel guestroom - Focusing on check-out status - (호텔 객실의 에너지 효율화를 위한 대기전력 분석 - 체크아웃 상태를 중심으로 -)

  • Lee, Junsoo;Koo, Choongwan
    • Journal of Urban Science
    • /
    • v.11 no.1
    • /
    • pp.15-20
    • /
    • 2022
  • The issue of hotel energy use is growing more significant as the hotel industry expands. It is important to take into account the electrical installation and space-specific features in a room unit in order to comprehend the energy consumption of a hotel guestroom. In light of this, this study aimed to analyze standby power for enhancing the energy efficiency of a hotel guestroom during check-out status. This study was conducted in three steps: (i) data collection; (ii) analysis of energy consumption patterns; and (iii) analysis of energy efficiency improvement plan. The main findings of this study can be summarized as follows. First, 32.24% of energy was used in fan coil unit) during check-out status. Second, a hotel guestroom had a 4.30% energy saving potential, based on energy consumption patterns during check-out status. This study can contribute to support hotel management to operate guestrooms differently by helping them identify patterns in energy use and realize potential savings.

An Analysis on the Causal Relation Between Electricity Consumption and GDP by industries in KOREA (한국의 산업별 전력소비와 경제성장간 인과관계 분석)

  • Park, Min Hyug;Roh, Geon Ki;Lee, Seung Eun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.39-45
    • /
    • 2016
  • In these days global energy policy is changed from "supply" to "demand". In this regards, there are needs to analysis on effect of policy such as energy efficiency strategy, electricity rates. This study examines the relationship between energy consumption reduced by new energy policy and GDP growth for each industrial sector for Korea from 1970 to 2013. With respect to the direction of causality, energy use of 1th industry like agriculture and mining leads to GDP growth. On the other hand, GDP growth of 2nd industry, manufacturing, leads to energy use. And there is bidirectional causality in 3rd industry, service sector. These findings imply that the government policies aimed at reducing electricity consumptions and increasing energy efficiency should be progressed cautiously depend on status of each industry condition.

Development of Multi Data Acquisition and Analysis Device for Tracked Vehicle Using SBC (SBC를 이용한 궤도차량의 다중데이터 획득 및 분석장치 개발)

  • Jeon, Ki-Hyun;Ha, Dong-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.10
    • /
    • pp.80-85
    • /
    • 2013
  • Recently it is becoming more common to apply vehicle electronics(Vetronics) based on information technology to improve the operability of the combat vehicles. Although the vehicle electronics system has been gradually developed, it is hard not only to design the reliable system which is a built-in multi-function but also to analyze the fault failure in the state of on-vehicle when failures occur. Therefore, It is required the data logging system like a aircraft's black box for the combat vehicles to enhance the reliability. In this paper, we developed the multi data acquisition and analysis device which is acquiring real-time data such as communication data, video data and voice data available for checking operational status of system and managing history. The performance of device has been proved on the vehicle.

Power System Stability Analysis Using a Hybrid Approach (하이브리드 방법을 이용한 전력계통 안정도 해석)

  • Seo, Gyu-Seok;Park, Ji-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.21-25
    • /
    • 2010
  • This paper explains hybrid method that combines Time domain simulation technique with the direct method of Transient stability analysis. First, it calculate trajectory of real system by Time domain Simulation using OOP(Object Oriented Programming method) and evaluate Transient Energy Function to induce stability index to calculate Transient stability margin. Once the status of system(stable or unstable) has been identified, proper criteria are proposed to stop time-domain simulation to reduce CPU time.

Analysis of Installation Environment and Fire Risk of Induction Motors Installed in the Curing Process of a Rubber Product Manufacturing Plant (고무제품제조공장의 가류공정에 설치된 유도전동기의 설치환경 및 화재위험성 분석)

  • Jong-Chan Lee;Doo-Hyun Kim;Sung-Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.2
    • /
    • pp.23-29
    • /
    • 2023
  • This study analyzed the fire status of a rubber product manufacturing factory based on 19 years of fire data. Through the analysis of the current state of fire, electrical fires accounted for 58.19%, and among electrical fires, motor fires were the highest at 26.21%. For the motor fire occurrence process, the curing process accounted for the highest rate of 51.9%. Therefore, the installation environment was investigated for the motor in the curing process, and it was confirmed that the motor's maximum ambient temperature exceeded 40℃. In particular, in the case of the motor for curing operation, the motor was installed in a separate motor room, so the average indoor temperature was 48.10℃ and the motor frame's maximum temperature was 72.80℃. In this study, the risk of motor fire was confirmed through a field survey, and a safety management plan was derived by finding a process with high fire risk and conducting an experiment on the motor's installation environment and electrical characteristics in that process.