• Title/Summary/Keyword: Analysis of Installation Status

Search Result 123, Processing Time 0.024 seconds

Automated Analysis of Scaffold Joint Installation Status of UAV-Acquired Images

  • Paik, Sunwoong;Kim, Yohan;Kim, Juhyeon;Kim, Hyoungkwan
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.871-876
    • /
    • 2022
  • In the construction industry, fatal accidents related to scaffolds frequently occur. To prevent such accidents, scaffolds should be carefully monitored for their safety status. However, manual observation of scaffolds is time-consuming and labor-intensive. This paper proposes a method that automatically analyzes the installation status of scaffold joints based on images acquired from a Unmanned Aerial Vehicle (UAV). Using a deep learning-based object detection algorithm (YOLOv5), scaffold joints and joint components are detected. Based on the detection result, a two-stage rule-based classifier is used to analyze the joint installation status. Experimental results show that joints can be classified as safe or unsafe with 98.2 % and 85.7 % F1-scores, respectively. These results indicate that the proposed method can effectively analyze the joint installation status in UAV-acquired scaffold images.

  • PDF

The Current Status and Cause Analysis of lightning Damages in Apartments (아파트에서의 낙뢰피해 현황과 원인 분석)

  • 이기홍;추성두
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.73-76
    • /
    • 2001
  • This paper dives the current status of lightning damages in apartments obtained by questionnaire and analysis the cause of ligntning damages. As a result, the apartments experienced lightning damages are assumed about 5[%] lot total apartments and the lightning surges invaded on power line are identified as the main cause of lightning damages in apartments.

  • PDF

A Study on the Status Monitoring and Fault Analysis of the Switching Rectifier for Power Factor Correction (역률개선용 스위칭 정류기의 데이터 수집과 저장에 관한 연구)

  • Ahn, Tae-Young;Im, Bum-Sun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.2
    • /
    • pp.49-56
    • /
    • 2016
  • In this paper, a prototype of power supply with a power factor correction is proposed. As a unique feature the proposed power supply, a status monitoring circuit is embedded on the switching power supply. The status monitoring circuit analyzes the functionality of the system and saves the key components of the power supply in the case of malfunctions. The results of various fault tests are reported to verify the operation and performance of the proposed method. This paper discusses the experimental results of the monitoring module and provides the technical information to monitor, predict, and troubleshoot the system against the potential failure of power supplies for real applications.

A Study on Status and Analysis of Local Governments Light Pollution Control Ordinance (지방자치단체 빛공해 방지 조례의 현황 및 분석)

  • Ryu, Ji-Seon;Lee, Jin-Sook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.10
    • /
    • pp.7-16
    • /
    • 2015
  • This study is intending to look into the status of the hitherto established local governments light pollution control ordinance, and to use the ordinance status as basic data of ordinance enactment related to light pollution in time of its establishment and revision in accordance with regional characteristics of each local government for the time to come. This study conducted this research in a total of 3-phase research methods. 1) This study inquired into the direction of the research plan through the theoretical consideration and analysis of the preceding researches after setting up research objectives according to research background and purpose. 2) Targeting 11 local governments which are enforcing the hitherto established ordinance, this study surveyed the status of the light pollution control ordinance. 3) This study carried out the contents analysis of the ordinance in the method of doing a comparative analysis of each provision of the ordinance according to local governments. It's hoped that on the basis of this research, local governments across the nation, which have not yet established the same ordinance, could minimize the damage to natural eco-system due to artificial lighting by promoting the urgent ordinance establishment suited for each region, and create human-oriented light environment by modifying various disorderly lighting environment.

Analysis of Installation Status and Application of GIS for Preliminary Risk Assessment of Underground Storage Tanks in Chuncheon City (춘천시의 지하 저장 탱크의 예비적 위해성 평가를 위한 설치 현황 분석 및 지리정보시스템의 적용)

  • Kim, Joon-Hyun;Han, Young-Han;Lee, Jong-Chun;Kwon, Young-Sung;Lee, Kwang-Yeon
    • Journal of Industrial Technology
    • /
    • v.22 no.A
    • /
    • pp.127-135
    • /
    • 2002
  • In this study, the preliminary risk assessment for the underground storage tanks(UST) in Chunchon city was implemented using the geographical information system(GIS). The estimation variables, such as the installation year, storage capacity, the distances from streams, and from groundwater pumping wells, were selected to estimate the relative risk levels. The weighting factors were given to all the estimation variables. Cumulative scores were induced by the combination of all the scores of the corresponding variables using the buffering technique and the overlay analysis in ArcView. Using the these process, the relative risk level of each UST was estimated. Some sites in this study are simplified and reduced because the number of useable data are limited or too enormous. Thus the selection of the comprehensive estimation variables and the proper weighting values are required for the future study. The methodology in this study could be served not only for the preliminary risk assessment of UST but also for the selection of the proper location of new and old UST. And, it can be used for the effective management system of UST.

  • PDF

Construction form and status analysis of intelligent type switching board of educational institution (교육기관 지능형 수배전반의 구성방식과 현황분석)

  • Choi, In-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.393-396
    • /
    • 2007
  • Recently one level higher intelligent switching board than established one by the application of intelligent building and digital system are being constructed. Therefore facility's high efficiency, high degree satisfaction, miniaturaization, standardization through application of communication technology and monitoring and controlling by computer system utilized by web-basis power control system and electric IT are practiced. Especially network must be constructed through unified IBS server that monitors every educational institute's switching boards in real time control system. And I intend to create methods to save energy and raise electricity quality by power demand prediction and remote-controled management and operation. In this thesis I intend to suggest measures of forming unified system through researching educational institute's ways of constructing switching board and status analysis and overcoming technical difficulties in user's side and saving and maintenance expense.

  • PDF

Analysis of the Status of Safety Management of Photovoltaic Power Generation Facilities (태양광발전설비 안전관리 현황 분석)

  • Kim, Wan-su;Park, Sang-June;An, Seong-ryeol
    • Current Photovoltaic Research
    • /
    • v.7 no.2
    • /
    • pp.38-45
    • /
    • 2019
  • In this paper, we analyzed the present status of the safety manager and safety assurance aspects through a complex analysis on the operational aspects, marketability and electrical safety aspects of photovoltaic power generation facilities. In the analysis of the equipment status, we analyzed the status and operated status of the installed PV system in Korea and the correlation between the safety manager and the accident. In addition, we analyzed the direction of the ESS through the analysis of the installation status of the ESS, and applied it to the interpretation part of the ESS associated with the solar power generation. The status of the electric safety manager can be used to analyze the data for selecting the electric safety manager by capacity by analyzing the accident status, the electric safety manager operation status, the safety management time by capacity, and the electric safety manager market.

Analysis of Insulator Failures Altar Installation of Arcing Horns in 154kV Transmission Lines (154kV 송전선로 Arcing Horn 적용에 따른 애자련 사고분석)

  • Cho, S.B.;Lee, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1743-1745
    • /
    • 1998
  • Insulators of 154kV T/L have been frequently damaged by fault currents. Arcing horn is a very effective and economic method for protection of insulators from the flashover. We developed arcing horns for 154kV T/L in order to protect insulators from the arc[1]. This paper analyzes the status of insulator failures in 154kV T/L after installation of the arcing horns.

  • PDF

Big Data Analytic System based on Public Data (공공 데이터 기반 빅데이터 분석 시스템)

  • Noh, Hyun-Kyung;Park, Seong-Yeon;Hwang, Seung-Yeon;Shin, Dong-Jin;Lee, Yong-Soo;Kim, Jeong-Joon;Park, Kyung-won
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.5
    • /
    • pp.195-205
    • /
    • 2020
  • Recently, after the 4th industrial revolution era has arrived, technological advances started to develop and these changes have led to widespread use of data. Big data is often used for the safety of citizens, including the administration, safety and security of the country. In order to enhance the efficiency of maintaining such security, it is necessary to understand the installation status of CCTVs. By comparing the installation rate of CCTVs and crime rate in the area, we should analyze and improve the status of CCTV installation status, and crime rate in each area in order to increase the efficiency of security. Therefore, in this paper, big data analytic system based on public data is developed to collect data related to crime rate such as CCTV, female population, entertainment center, etc. and to reduce crime rate through efficient management and installation of CCTV.

A Study on The Improvement of Related Regulation System for The Utility Tunnel Activation (지하공동구 활성화를 위한 관련규정 체계 개선에 관한 연구)

  • Oh, Won-Joon;Cho, Choong-Yeun;Lee, Min-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.563-571
    • /
    • 2020
  • The purpose of a utility tunnel is to prevent repeated excavation as well as disasters and calamity. Domestic utility tunnels have been built in new town development plans. Currently, it is difficult to establish a utility tunnel due to a conflict of opinions by organization and financing. In this paper, research was conducted based on systematic procedures to suggest ways of improving the activation of utility tunnels in new cities and existing cities. First, a survey was conducted on the laws and status of utility tunnels, and problems were derived based on the review and analysis of the status. Finally, a method suggesting improvement measures to solve problems was applied. Based on the related laws and problems, the status of the development project was analyzed to select the installation scale in the utility tunnel, and the appropriate scale was reviewed through economic feasibility analysis of the installation scale under 2 million square meters. Considering the new city and the existing city, it was proposed to support administrative expenses to reduce the burden on additional installation areas and occupied institutions in a utility tunnel. In addition, improvement plans were presented for the details of the master plan for reviewing the installation regional of the utility tunnel. This paper will help officials to work smoothly when planning and installing utility tunnels in the future.