• Title/Summary/Keyword: Analysis field

Search Result 22,236, Processing Time 0.051 seconds

Analysis of 3-Dimensional Magnetic Field Distribution in CPM Considering Magnetization Vector Distribution and Design of CPM (자화 벡터 분포를 고려한 CPM의 3차원 자계 분포 해석 및 설계)

  • Lee, Cheol-Gyu;Gwon, Byeong-Il;Park, Seung-Chan;U, Gyeong-Il
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.10
    • /
    • pp.545-553
    • /
    • 2002
  • This paper is about the analysis of 3-dimensional magnetic field distribution in CPM(Convergence Purity Magnet) considering magnetization vector and the optimum design of CPM. The magnetization vector of CPM is obtained using 2-dimensional magnetization FEA(Finite Element Analysis) coupled with Priesach model. Using this magnetization vector of CPM, we analysed the 2-dimensional and 3-dimensional magnetostatic field of CPM and know that these analysis results are not equal. From experimental result, we know that the 3-dimensional analysis is accurate because the magnetic field distribution in CPM cannot be considered correctly by 2-dimensional analysis because of the shape of CPM. Finally, the optimum designing of CPM which control accurately the electron beam deflection in CRT(Cathode Ray Tube) was possible using 3-dimensional magnetic field analysis result.

A Review on the Qualification System of the Environmental field : Current Status and New Directions (환경분야 자격제도 운영현황과 발전 방안 연구)

  • 박종성;이무춘
    • Hwankyungkyoyuk
    • /
    • v.14 no.1
    • /
    • pp.43-55
    • /
    • 2001
  • The purpose of this study was to review the current status and problems of the national qualification system in the Environmental field focusing on deficiencies of the regulatory system and qualities of environmental professional including the Environmental control Professional Engineer, Environmental Engineer, Environmental Industrial Engineer and Environmental field. An overview of the environmental field, its current status, domestic qualification items and training conditions in environment-related areas, laws of environmental field, and data of the job analysis were reviewed. The concrete and extensive development plans for the qualification system of the Environmental field are as follows: First of all, a job analysis should be made of on the introduction of new systems or policy modification to reflect technical changes and national policies about the environmental field in the qualification exam. Second, it is essential to prepare policies that are suitable for the qualification system in the Environmental field and that improve its effectiveness. Third, the appropriate policy measures should be taken in order to elevate the social standing of Environmental field qualification holders.

  • PDF

Evaluation of Near-Fault Ground Motions by Inelastic Response Spectrum Analysis (비탄성 응답스펙트럼 분석을 통한 근거리 지진의 평가)

  • 김형규;최인길;전영선
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.69-76
    • /
    • 2003
  • Near-field ground motions exhibit special characteristics that are different from ordinary far-field ground motions. This paper first briefly examines the characteristics of near-field ground motions associated with fault directivity and fling-step effects. Then evaluation of near-field ground motions by inelatstic response spectrum analysis is performed and analyzed. As a result, ductility demand in near-field ground motions is larger in hanging wall than in foot wall in long period regions. Also in long period regions ductility demand in soil site is larger than that in rock site.

  • PDF

Development of a CDMA Field Engineering System (CDMA 필드 엔지니어링 시스템 개발)

  • Lee, Chan-Su;Im, Hui-Gyeong;Hong, Seong-Cheol;Im, Jae-Bong;Seong, Yeong-Rak;O, Ha-Ryeong
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.5
    • /
    • pp.1500-1510
    • /
    • 2000
  • In this paper, a CDMA (Code Division Multiple Access) field engineering system is designed and implemented for managing cellular telecommunication base stations. For high quality of CDMA service, optimized cell planning is crucial. For such cell planning, base stations must be managed based on analysis of CDMA field dta. The proposed system consists of two modules: a measurement module and au analysis of CDMA field dta. eh proposed system consists of tow modules; a measurement module and an analysis module. The measurement module collects various CDMA field dta and displays them on a vector map in a real-time manner. The analysis module associates measured data with various related information, e.g. base station information, and process them statistically. The proposed system can drastically reduce base station management cost.

  • PDF

Quantitative evaluating method for diagnostic ultrasound probe using 3-dimensional acoustic field analysis (3차원 음장 분석법을 이용한 진단용 초음파 프로브의 정량적 성능평가)

  • Noh, Si-Cheol;Kim, Ju-Young;Park, Jae-Hyun;Kim, Jin-Su;Kang, Jung-Hoon;Choi, Heung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.490-496
    • /
    • 2010
  • In this study, in order to overcome the weakness of acoustic field analysis which is generally used for ultrasonic probe performance evaluation, automatic acoustic field measurement system and evaluation parameters were proposed. The comparisons between acoustic field simulation and measured acoustic distribution data of normal and abnormal channels were conducted to evaluate the availability of proposed system and evaluation parameters. First, the impulse response characteristic of sample probe was investigated to classify the normal elements and abnormal elements. And then, normal channels and abnormal channels with abnormal element were chosen. The suggested 12 evaluation parameters were calculated using the acoustic fields of these channels. The availability of proposed automatic acoustic field measurement system and evaluation parameters was confirmed. And the performance evaluation of ultrasonic probe using acoustic field analysis could be easier and faster.

A Study on Field Applicability Evaluation of the Hydrophobic - Low Viscosity Surface Treatment Material for Pavement Preventive Maintenance (소수성 특성을 이용한 저점도 AP 표면처리재의 현장 적용성 연구)

  • Choi, Jun Seong
    • International Journal of Highway Engineering
    • /
    • v.16 no.1
    • /
    • pp.31-39
    • /
    • 2014
  • PURPOSES : Surface treatment material for pavement preventive maintenance should be inspected field applicability. This study(Part II) aimed to checkup coating characteristics and performance analysis using lab and field tests. The hydrophobic - low viscosity filling material for pavement preventive maintenance is presented in Part I, which is a series of companion study. METHODS : Relative comparison between general asphalt mixtures and surface treatment asphalt mixtures are analyzed and measured for the field application such as indirect tensile strength ratio(TSR), abrasion resistance, crack propagation resistance, temperature resistance, coating thickness, permeability resistance and skid resistance in terms of british pendulum number(BPN). RESULTS : It is found that TSR, crack propagation resistance and permeability resistance is increased as against uncoated asphalt specimen. Abrasion resistance and temperature resistance is secured from the initial coating thickness point of view, which is about 0.2~0.3mm. Skid resistance on the surface treatment pavement is satisfied with the BPN criteria of national highway because of exposed aggregate and crack sill induced pavement deterioration and damage cracks. CONCLUSIONS : The hydrophobic - low viscosity surface treatment material for pavement preventive maintenance is validated on field applicability evaluation based on quantitative analysis of coating thickness and performance analysis using lab and field tests.

A Study of Testing Method for Diagnostic Ultrasonic Array Probe through Pattern Analysis of Acoustic-Fields with Probe Channel Division (채널별 음장분포 분석을 통한 진단용 초음파 어레이 프로브의 평가방법에 관한 연구)

  • Yoo, B.C.;Choi, H.H.;Noh, S.C.;Min, H.K.;Kwon, J.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.5
    • /
    • pp.229-236
    • /
    • 2006
  • The acoustic field analysis method is the superior calibration method for rectifying the ultrasonic probe sensitivity. This method also can be applied to evaluate the probe performance in clinical fields without numerical analysis and precise measurements. In this paper, we propose the method of acoustic field pattern analysis with probe channel division for the evaluation of diagnostic ultrasound probe characterization. In order to verify our purpose, we performed a set of experiments. We measured the acoustic-field pattern of the three inferiority probes by channel division to evaluate an acoustic field distribution and impulse response characteristics. By comparing the results of acoustic field measurement method with that of conventional method such as impulse response and live image test for linear array probes, it is demonstrated that the ultrasound field measurement method is more effective then conventional method in detection of defective elements.

Analysis on Static Characteristics of Slotless Type Permanent Magnet Electrical Machines Using the Electromagnetic Transfer Relations (전자기 전달관계를 이용한 슬롯리스형 영구자석 전기기기의 정특성 해석)

  • Jang, Seok-Myeong;Choi, Jang-Young;Lee, Sung-Ho;Cho, Han-Wook
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.3
    • /
    • pp.138-145
    • /
    • 2006
  • It is well known that the accurate calculation of the field distribution is essential for the design of electrical machines. The analytical techniques for electromagnetic field can quickly and exactly determine airgap magnetic field distribution in electrical machines. Many analytical techniques have been investigated to predict the magnetic field distribution in PM machines equipped with permanent magnets. Using the analytical technique by transfer relations, D. L. Trumper and K. R. Davey already presented the design and analysis of linear permanent-magnet machines and induction machines, respectively. Using the transfer relations (Melcher's general methodology) to describe electromagnetic phenomena, this paper deals with the analysis on the magnetic field distribution due to PM and winding current, the induced voltage and the static torque characteristics in surface-mounted slotless type permanent magnet machine. The validity of the analysis results is confirmed by finite element (FE) analysis.

A Study on Room Acoustic Field Analysis using Radiosity Method (라디오시티법을 이용한 실내 음향장 해석 연구)

  • Kim, Kookhyun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.55 no.5
    • /
    • pp.394-400
    • /
    • 2018
  • Various numerical methods have been adopted for indoor noise assessments of ship plant. Acoustical radiosity method is one of the high frequency approaches for acoustic field analysis, which assumes diffuse reflections by boundaries so that it could be efficiently applied to the acoustically diffused indoor space noise analysis. In this study, an acoustic field analysis program has been developed based on radiosity method, which could apply for acoustically large enclosures such as ship's indoor space. For this purpose, the procedure of the acoustical radiosity method has been summarized and implemented to an acoustic field analysis program using MATLAB. Numerical example for a rectangular indoor space has investigated validity of the implemented program. Steady state sound pressure levels calculated for a continuous acoustic source signal have shown good agreement with those by other solutions such as an analytic solution and a ray tracing method. Instantaneous sound pressure levels calculated for an impulsive acoustic signal have provided the clues of direct/reflected acoustic field and reverberation time.

Analysis of Solar Microwave Burst Spectrum, I. Nonuniform Magnetic Field

  • Lee, Jeongwoo
    • Journal of Astronomy and Space Sciences
    • /
    • v.35 no.4
    • /
    • pp.211-218
    • /
    • 2018
  • Solar microwave bursts carry information about the magnetic field in the emitting region as well as about electrons accelerated during solar flares. While this sensitivity to the coronal magnetic field must be a unique advantage of solar microwave burst observations, it also adds a complexity to spectral analysis targeted to electron diagnostics. This paper introduces a new spectral analysis procedure in which the cross-section and thickness of a microwave source are expressed as power-law functions of the magnetic field so that the degree of magnetic inhomogeneity can systematically be derived. We applied this spectral analysis tool to two contrasting events observed by the Owens Valley Solar Array: the SOL2003-04-04T20:55 flare with a steep microwave spectrum and the SOL2003-10-19T16:50 flare with a broader spectrum. Our analysis shows that the strong flare with the broader microwave spectrum occurred in a region of highly inhomogeneous magnetic field and vice versa. We further demonstrate that such source properties are consistent with the magnetic field observations from the Michelson Doppler Imager instrument onboard the Solar and Heliospheric Observatory (SOHO) spacecraft and the extreme ultraviolet imaging observations from the SOHO extreme ultraviolet imaging telescope. This spectral inversion tool is particularly useful for analyzing microwave flux spectra of strong flares from magnetically complex systems.