• Title/Summary/Keyword: Analysis Error

Search Result 9,236, Processing Time 0.045 seconds

Study on mechanical behaviors of large diameter shield tunnel during assembling

  • Feng, Kun;Peng, Zuzhao;Wang, Chuang;He, Chuan;Wang, Qianshen;Wang, Wei;Cao, Songyu;Wang, Shimin;Zhang, Haihua
    • Smart Structures and Systems
    • /
    • v.21 no.5
    • /
    • pp.623-635
    • /
    • 2018
  • In order to study the mechanical behavior of shield tunnel segments during assembly stage, the in-situ tests and FDM numerical simulation were conducted based on the Foguan Shiziyang Tunnel with large cross-section. Analysis for the load state of the assembling segments in different assembly steps as well as the investigation for the changing of inner forces and longitudinal stress of segments with assembling steps were carried out in this paper. By comparing the tested results with the simulated results, the conclusions and suggestions could be drawn as follows: (1) It is the most significant for the effects on axial force and bending moment caused by the assembly of adjacent segment, followed by the insertion of key segment while the effects in the other assembly steps are relative smaller. With the increasing value of axial force, the negative bending moment turns into positive and remains increasing in most monitored sections, while the bending moment of segment B1and B6 are negative and keeping increasing; (2) The closer the monitored section to the adjacent segments or the key segment, the more significant the internal forces response, and the monitored effects of key segment insertion are more obvious than that of calculation; (3) The axial forces are all in compression during assembling and the monitored values are about 1.5~1.75 times larger than the calculated values, and the monitored values of bending moment are about 2 times the numerical calculation. The bending moment is more sensitive to the segments assembly process compared with axial force, and it will result in the large bending moment of segments during assembling when the construction parameters are not suitable or the assembly error is too large. However, the internal forces in assembly stage are less than those in normal service stage; (4) The distribution of longitudinal stress has strong influence on the changing of the internal forces. The segment side surface and intrados in the middle of two adjacent jacks are the crack-sensitive positions in the early assembly stage, and subsequently segment corners far away from the jacks become the crack-sensitive parts either.

Constructed Mobile System for Management affair of Water & sewage Facilities (상하수도 유지관리업무를 위한 모바일 시스템 구축)

  • Lee, Hyun-Jik;Park, Ki-Suk;Ru, Ji-Ho
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.12 no.3 s.30
    • /
    • pp.69-78
    • /
    • 2004
  • Since 1995, One of the NGIS(National Geographic Information System) projects, the underground utilities project, has been finished in 2003. The 19 cities in korea for this project will use underground utilities management system using underground utilities database focusing on water and sewage system. However, special expert, technical and experience problem in computer environment has not been had in working department for water and sewage management and maintenance for each local government. The management and maintenance by underground utilities database by manual method is getting lowered a data qualify of underground utilities database because of the data omitting, error in writing and securing of the lasted database. Therefore, in this study, Application test for field workers using a mobile tool and environment analysis of wireless communication in Korea and application test of GPS receiver for mobile tools had been processed and made a mobile working environment. The efficient management and maintenance method for underground utilities database has been developed an off-line method for modification and update of database about general work which has a high working frequency because of the limitation of wireless communication environment. Also, the emergency working has been applied for on-line method.

  • PDF

Performance Analysis of MVDR and RLS Beamforming Using Systolic Array Structure (시스토릭 어레이 구조를 갖는 최소분산 비왜곡응답 및 최소자승 회귀 빔형성기법 성능 분석)

  • 이호중;서상우;이원철
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.1
    • /
    • pp.1-6
    • /
    • 2003
  • This paper analyses the performance of either the minimum variance distortionless response (MVDR) or the recursive least square (RLS) beamformer structured on the systolic array. Provided that the snapshot vector including the desired user's signal and the interferences with the noise is received at the array antenna. In order to improve the quality of received signal, MVDR or RLS algorithm can be utilized to update the beamformer weights recursively. Furthermore to increase the channel capacity, by the usage of the above schemes, the effect of the spatial filtering can be obtained which constructively combining multipath components corresponding to the desired user whereas the multiple access interferences (MAI) is nulled out on spatial domain. This paper introduces the MVDR and RLS beamformer structured on systolic array conducting the spatial filtering, and its performance under the multipath fading channel in the presence of multiple access interferences will be analyzed. To show the superior spatial filtering performances of the proposed scheme employing the systolic way structured beamformer, the computer simulations are carried out. And the validity of practical deployment of the proposed scheme will be confirmed throughout showing the BER behaviors and the beampatterns.

Accuracy of linear measurement using cone-beam computed tomography at different reconstruction angles

  • Nikneshan, Sima;Aval, Shadi Hamidi;Bakhshalian, Neema;Shahab, Shahriyar;Mohammadpour, Mahdis;Sarikhani, Soodeh
    • Imaging Science in Dentistry
    • /
    • v.44 no.4
    • /
    • pp.257-262
    • /
    • 2014
  • Purpose: This study was performed to evaluate the effect of changing the orientation of a reconstructed image on the accuracy of linear measurements using cone-beam computed tomography (CBCT). Materials and Methods: Forty-two titanium pins were inserted in seven dry sheep mandibles. The length of these pins was measured using a digital caliper with readability of 0.01 mm. Mandibles were radiographed using a CBCT device. When the CBCT images were reconstructed, the orientation of slices was adjusted to parallel (i.e., $0^{\circ}$), $+10^{\circ}$, $+12^{\circ}$, $-12^{\circ}$, and $-10^{\circ}$ with respect to the occlusal plane. The length of the pins was measured by three radiologists, and the accuracy of these measurements was reported using descriptive statistics and one-way analysis of variance (ANOVA); p<0.05 was considered statistically significant. Results: The differences in radiographic measurements ranged from -0.64 to +0.06 at the orientation of $-12^{\circ}$, -0.66 to -0.11 at $-10^{\circ}$, -0.51 to +0.19 at $0^{\circ}$, -0.64 to +0.08 at $+10^{\circ}$, and -0.64 to +0.1 at $+12^{\circ}$. The mean absolute values of the errors were greater at negative orientations than at the parallel position or at positive orientations. The observers underestimated most of the variables by 0.5-0.1 mm (83.6%). In the second set of observations, the reproducibility at all orientations was greater than 0.9. Conclusion: Changing the slice orientation in the range of $-12^{\circ}$ to $+12^{\circ}$ reduced the accuracy of linear measurements obtained using CBCT. However, the error value was smaller than 0.5 mm and was, therefore, clinically acceptable.

Numerical Analysis of Differential Absorption Lidar for Measuring Atmospheric Pollutants (대기오염 측정용 DIAL시스템의 오차해석)

  • 박진화;이용우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.428-433
    • /
    • 2003
  • In this study, we composed algorithm of DIAL(Differential Absorption Lidar). we investigated the absorption spectrum of $O_3$, S $O_2$ and N $O_2$ dependent on wavelengths using data base UV-Bank and determine the optimized wavelength model. Here, the selected optimal wavelengths are 292.00(λ$_{on}$ ), 295.20(λ$_{off}$) for $O_3$, 299.38(λ$_{on}$ ), 300.05(λ$_{off}$) for S $O_2$ and 448.00(λ$_{on}$ ), 449.85(λ$_{off}$) for N $O_2$. In particular, we established the supposed model of DIAL and simulated the error of measuring distance using the selected optimal wavelength. In the model-I with telescope of 300 mm diameter, laser energy of 3 mJ and transmission of 10000 shots, maximum distances are 4 km for $O_3$ measurement and 5 km for S $O_2$ and N $O_2$ measurements. Also, in the model-II with telescope of 600 mm diameter, laser energy of 30 mJ and transmission of 10000 shots, maximum distances are 13 km for S $O_2$ and N $O_2$ measurements.ments.

  • PDF

A Study on the Performance Improvement of Turbo Coded OFDM Systems Considering Frequency Offset (주파수 오프셋을 고려한 Tued OFDM 시스템의 성능 개선에 관한 연구)

  • 이영춘;박기식
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.5
    • /
    • pp.908-915
    • /
    • 2001
  • In this paper, it is analyzed theoretically that the performance degradation, caused by carrier frequency offset, in an OFDM/M-ary PSK system. Then, when Turbo coding is adopted to an OFDM/M-ary PSK system, the degree of performance enhancement is evaluated. Finally, the maximum frequency offset is calculated to satisfy the BER performance required in a Turbo coded OFDM/M-ary PSK system. As results of analysis, it is shown that the more the number of M-ary is, the worse the BER performance is. Moreover, 7dB, 9dB, and 17dB of $E_b/N_o$ are required in QPSK, 8PSK and 16PSK systems, respectively in order to satisfy the error performance, $BER=10^{-3}$ for voice communication. If $E_b/N_o$ are 10㏈ and 15㏈, the frequency offset should be below 0.05 and 0.075, respectively, for voice communication. When Turbo coding is adopted to an OFDM/M-ary PSK system, the less the number of M-ary is, the greater the performance enhancement of Turbo coding is. If the number of a M-ary system of the system is below 16, it is found that required $E_b/N_o$ is about 8dB to satisfy $BER=10^{-5}$ Moreover, in the system the Turbo coding scheme, voice communication is available with greatly low$E_b/N_o$, and 8dB of $E_b/N_o$ is enough for data communication regardless of the permission range of frequency offset.

  • PDF

Defect Detection of Ship Engine using duplicated checking of vibration-data-distinction Method and Classification of fault-wave (이중화된 진동 정보 판별 기법과 고장 파형 분류를 이용한 선박 엔진의 고장 감지)

  • Lee, Yang-Min;Lee, Kwang-Young;Bae, Seung-Hyun;Shin, Il-Sik;Jang, Hwi;Lee, Jae-Kee
    • Journal of Navigation and Port Research
    • /
    • v.33 no.10
    • /
    • pp.671-678
    • /
    • 2009
  • Recently, there have been some researches in the equipment fault detection based on shock and vibration information. Most research of them is based on shock and vibration monitoring to determine the equipment fault or not. Different with engine fault detection based on shock and vibration information we focus on detection of engine for boat and system control. First, it use the duplicated-checking method for shock and vibration information to determine the engine fault or not. If there is a fault happened, we use the integral to determine the error engine shock wave width and detect the fault area. On the other hand, we use the engine trend analysis and standard of safety engine to implement the shock and vibration information database. Our simulation results show that the probability of engine fault determination is 98% and the probability of engine fault detection is 72%

Analysis of Uncertainties due to Digitally Reconstructed Radiographic (DRR) Image Quality in 2D-2D Matching between DRRs and kV X-ray Images from the On-Board Imager (OBI) (디지털 재구성 방사선영상과 온보드 영상장치를 이용한 2D-2D 정합 시 디지털 재구성 방사선영상의 질이 정합 정확도에 미치는 영향 분석)

  • Cheong Kwang-Ho;Cho Byung-Chul;Kaug Sei-Kwon;Kim Kyoung-Joo;Bae Hoon-Sik;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.67-76
    • /
    • 2006
  • We evaluated the accuracy of a patient setup error correction due to reference image quality for a 2D-2D matching process. Digitally reconstructed radiographs (DRRs) generated by use of the Pinnacle3 and the Eclipse for various regions of a humanoid phantom and a patient for different CT slice thickness were employed as a reference images and kV X-ray Images from the On-Board Imager were registered to the reference DRRs. In comparison of the DRRs and profiles, DRR image quality was getting worse with an increase of CT image slice thickness. However there were only slight differences of setup errors evaluation between matching results for good and poor reference DRRs. Although DRR image quality did not strongly affect to the 2D-2D matching accuracy, there are still potential errors for matching procedure, therefore we recommend that DRR images are needed to be generated with less than 3mm slice thickness for 2D-2D matching.

  • PDF

The Influence of Volume Effect in 2D-array Ion Chamber on the Measurement of IMRT Dose Distribution (2차원 배열형 이온함의 부피효과가 세기조절방사선치료의 선량분포 측정에 미치는 영향)

  • Kim, Sung Joon;Lee, Seoung Jun;Park, In Kyu;Lee, Jeong Eun;Park, Shin Hyung;Seol, Ki Ho;Kim, Jae Chul
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.41-47
    • /
    • 2013
  • We evaluated the influence of volume effect on the measurement of IMRT dose distribution by comparing a 2D-array ion chamber and other dosimeters. Matrix phantom which is a 2D-array ion chamber having volume effect was compared with beam image system and film for the measurement of dose distribution. Five intensity-modulated radiation therapy plans were created using five fields in thevirtual phantom. The measured dose distribution was compared with the calculated one by radiation treatment planning system and analysis program. We evaluated the conformity of dose distribution by calculating correlation coefficients and gamma values. The highest error rate of 1.3% was associated with matrix phantom in which volume effect in small field sizes was substantial.

Modification of the Fixed Coefficient Method for the Parameter Estimation of Storage Function Method (저류함수법의 매개변수 추정을 위한 상수고정법의 개선)

  • Chung, Gunhui;Park, Hee-Seong
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.1
    • /
    • pp.73-85
    • /
    • 2013
  • The researches on the parameter estimation for storage function method have been conducted for a long time using different methods. However, the determination of the optimal parameters takes a long time and there is a controversy that the proposed optimal parameters do not likely represent the physical characteristics of watershed. In this study, the characteristics of the continuity and storage function equation was analyzed and sensitivities were evaluated. As the result, the only optimal solution is suggested among several local optimums. It is also shown that the lag time is able to be determined using the direct runoff starting time of the watershed. From the sensitivity analysis, it is also proved that the determination of the lag time is very important and the only optimal solution could be found easily after selecting the lag time. Therefore, unlike the traditional optimization method, the proposed method does not take a long time to find the optimal solution which is depending on the characteristics of the rainfall events. The fixed coefficient method which is a method to estimate the optimal parameters of storage function method has been modified using the proposed method. Therefore, the practical efficiency to apply storage function method could be enhanced by applying the proposed method. While the traditional method takes care only the error of the runoff hydrograph, it is very important that the proposed method considers the characteristics of the watershed.