• Title/Summary/Keyword: Amount of supply

Search Result 1,351, Processing Time 0.024 seconds

Optimal valve installation of water distribution network considering abnormal water supply scenarios (비정상 물공급 시나리오를 고려한 상수도관망 최적 밸브위치 결정)

  • Lee, Seungyub;Jung, Donghwi
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.10
    • /
    • pp.719-728
    • /
    • 2019
  • Valve in water distribution network (WDN), that controls the flow in pipes, is used to isolate a segment (a part of WDN) under abnormal water supply conditions (e.g., pipe breakage, water quality failure event). The segment isolation degrades pressure and water serviceability in neighboring area during the water service outage of the segment. Recent hydraulic and water quality failure events reported encouraging WDN valve installation based on various abnormal water supply scenarios. This study introduces a scenario-based optimal valve installation approach to optimize the number of valves, the amount of undelivered water, and a shortest water supply path indicator (i.e., Hydraulic Geodesic Index). The proposed approach is demonstrated in the valve installation of Pescara network, and the optimal valve sets are obtained under multiple scenarios and compared to the existing valve set. Pressure-driven analysis (PDA) scheme is used for a network hydraulic simulation. The optimal valve set derived from the proposed method has 19 fewer valves than the existing valve set in the network and the amount of undelivered water was also lower for the optimal valve set. Reducing the reservoir head requires a greater number of valves to achieve the similar functionality of the WDN with the optimal valve set of the original reservoir head. This study also compared the results of demand-driven analysis (DDA) and the PDA and confirmed that the latter is required for optimal valve installation.

Economic Impacts of Renewable Portfolio Standard on Domestic Industry (신재생에너지 의무할당제의 국내산업에 대한 파급효과)

  • Kim, Hyun Jae;Cho, Gyeong Lyeob
    • Environmental and Resource Economics Review
    • /
    • v.19 no.4
    • /
    • pp.805-828
    • /
    • 2010
  • Korea also plans to introduce Renewable Portfolio Standard (RPS) for strengthening market functions after 2012 as United States and several members of EU countries did. Through the introduction of RPS, it requires energy industry to supply new and renewable energy at fixed rate. Therefore, it will contribute to the distribution of new and renewable energy. This paper analyzed the economic effect of the introduction of RPS using CGE. The summary of the paper on the analysis of the economic effect based on endogenous growth theory under imperfect market competition by using CGE is as follows; Since RPS possibly regulates the amount of new and renewable energy, it can achieve the target amount of new and renewable energy without fail. As achieving the target amount accurately, the distribution of more advanced skills can be expected. However, GDP reduction can occur because investment cost increases due to the requirement of new and renewable energy supply. Therefore, in the long run, it is appropriate to introduce RPS because it contributes to the distribution of new and renewable energy and can be utilized as a new growth engine to encourage economic growth.

  • PDF

Evaluation of hydropower dam water supply capacity (II): estimation of water supply yield range of hydropower dams considering probabilistic inflow (발전용댐 이수능력 평가 연구(II): 확률론적 유입량을 고려한 발전용댐 용수공급능력 범위 산정)

  • Jeong, Gimoon;Kang, Doosun;Kim, Dong Hyun;Lee, Seung Oh;Kim, Taesoon
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.7
    • /
    • pp.515-529
    • /
    • 2022
  • Identifying the available water resources amount is an essential process in establishing a sustainable water resources management plan. Dam facility is a major infrastructure storing and supplying water during the dry season, and the water supply yield of the dam varies depending on dam inflow conditions or operation rule. In South Korea, water supply yield of dam is calculated by reservoir simulation based on observed historical dam inflow data. However, the water supply capacity of a dam can be underestimated or overestimated depending on the existence of historical drought events during the simulation period. In this study, probabilistic inflow data was generated and used to estimate the appropriate range of the water supply yield of hydropower dams. That is, a method for estimating the probabilistic dam inflow that fluctuates according to climatic and socio-economic conditions and the range of water supply yield for hydropower dams was presented, and applied to hydropower dams located in the Han river in South Korea. It is expected that the understanding water supply yield of the hydropower dams will become more important to respond to climate change in the future, and this study will contribute to national water resources management planning by providing potential range of water supply yield of hydropower dams.

Assessment of Additional Water Supply Capacity Using a Reservoir Optimal Operation Model (저수지 최적 운영 모형을 이용한 추가 용수 공급 능력 평가)

  • Kang, Min-Goo;Park, Seung-Woo
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.11
    • /
    • pp.937-946
    • /
    • 2005
  • The objective of the study is to develop a reservoir optimal operation model and to suggest the appropriate amount of additional water supply and optimal operation rule. The model uses multiple objective function and a global search method, SCE-UA method. The objective function is set up to maintain the storage at target level, to satisfy the water demand, and to maximize the hydropower product. To evaluate the model's applicability, the model was applied for allocating the optimal water depending on storage level changes of Seomjin dam. The results comparing optimal operation and historical data showed that hydropower product increased from $-2.29\%$ to $14.51\%$, $-5.94\%$ to $3.98\%$, and $-0.43\%$ to $6.35\%$ with varying target levels in wet, dry, and normal period, respectively. Also, The model was applied for assessing water supply capacity of Seomjin dam to satisfy increasing water demand. The dam was operated by the model on consideration of downstream flow as 0.17, 0.50, 0.70, 1.0, 1.5, and $3.0\;m^3/sec$. The results showed that in case of operating the dam with downstream flow less than $0.70\;m^3/sec$ and with target water level lower than 194.0 m, hydropower product was more than the historical operation data and existing amount of water supply was less influenced.

Comparison of Food Supply Status of Korean(Chosun) and Taiwan Prisoners under the Period of Japanese Rule with That of French and German Prisoners in 1920~1930′s (일제하(1920~30연대) 조선과 대만 그리고 프랑스와 독일 수형인의 식품공급상황 비교)

  • 허채옥
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.13 no.4
    • /
    • pp.267-283
    • /
    • 2003
  • This study reviewed the prisoners' dietary lift status under the world panics and Japanese food shortage based on the data of the 1920~1930's prisons' main dish supplies in Chosun, Shinchu boys' prison in Taiwan, Franue correction center in France and Moabit detention house in Germany. 1. The status of main dish food supply of Chosun prisons in 1920~1930's was as follows: 1) Meals were provided with 12 rates depending on the working activities. There were big differences in energy supply between 1$^{st}$ rate of 6045.0 ㎉ in the Mockpo prison and 12$^{th}$ rate of 1855.8 ㎉ in the Masan prison in accordance with the grain supply ratio and the diet rates. 2) The average ratio of energy provided with protein, fat and carbohydrate(PFC ratio) was 20.0: 20.2: 59.8. The supplies of protein and fat were relatively high because main dish was mostly composed of soybean. The soybean was used in 20 ~60% of main dish in prisons except Gaesung. 3) It was estimated that PFC ratio(8.3: 8.1 : 83.6) in Gaesung boys' prison was not appropriate for growing boys because the soybean supply was low. 2. The overall comparison of nutrition supply of prisons in Chosun, Taiwan, France and Germany was as follows: 1) The daily supplies of energy in Keongsung prison was 3966.5 ㎉, of which the PFC ratio was 18.9: 16.6: 64.5. This showed that the PFC ratio seemed to be balanced, even though the total amount of energy is too high and the ratios of protein and fat were somewhat high and somewhat low, respectively. 2) The main dish of the Taiwan boys' prison was provided with 6 rates and the side dish in the from of weekly cycle menu. The energy intakes from 1$^{st}$ rate of 2862.9 ㎉ to 6$^{th}$ rate of 1388.9 ㎉ were not quite enough for growing boys. It was estimated that the amounts of protein and fat taken were small but the quality was not that bad because animal protein such as protein small fish and fried tofu were supplied. 3) In the French Frenue correction center and the German Moabit detention house, the daily total amounts of energy were 2771.3 ㎉ and 2678.7 ㎉, respectively, which was estimated as appropriate compared with standard energy amount of 3000 ㎉ at that time and the current energy RDA of 2500 ㎉ for adult. The ratio of PFC was 16.2: 12.0: 71.8 in Frenue correction center and 12.4: 14.3: 73.3 in Moabit detention house, which showed that the amount of fat was slightly lacked. From this study, it was suggested that the prisons in Chosun and Taiwan under the Japanese rule and European prisons after the world panic were making an efforts to supply prisoners the appropriate amount of energy. The only question remains is that this data may be from only the food supply plan not from the data the prisoners took in real.eal.

  • PDF

A Study on the Supply System of Iron Materials and the Tools in Government Constructions in the Late of Joseon Dynasty (조선후기 관영건축공사에 있어서 철물과 철제 연장의 공급체계에 관한 연구 -영건의궤(營建儀軌) 기록을 중심으로-)

  • Lee, Kweon-Yeong;Kim, Wang-Jik
    • Journal of architectural history
    • /
    • v.16 no.3
    • /
    • pp.95-114
    • /
    • 2007
  • Since the 17th century, the society of Joseon dynasty belongs to a period of rapid transition in many fields. As the building is a result to be produced on the basis of a society and economy, the general transition in a society is to be reflected into a process of building construction. Especially, a study on the material supply system of economic base in a process of building construction is one of vely important factors in an understanding or estimate of a building. On the premise, this paper is to examine the supply system of iron materials and the tools in the construction of the government managed buildings in the late of Joseon dynasty on a viewpoint of productivity. Construction reports and other documents in those days are examined for the study. Following conclusions have been reached through the study. 1) The general supply method of iron materials for a large-scale government construction was based on 'byulgong', that is, a kind of tribute. 2) Various methods were selected in the supply method of iron materials for government use in the late of Joseon dynasty. The priority order of choice in its government policy was put on an easiness of amount security, on a minimum of expenditure, and on an efficiency of construction execution. 3) The manufacturing technique of weaponry was used in the production method of iron materials and the tools for government use. The cooperation of the official, the army, and the merchant had improved the manufacturing technique of building construction.

  • PDF

Prediction of Daily Water Supply Using Neuro Genetic Hybrid Model (뉴로 유전자 결합모형을 이용한 상수도 1일 급수량 예측)

  • Rhee, Kyoung-Hoon;Kang, Il-Hwan;Moon, Byoung-Seok;Park, Jin-Geum
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.4
    • /
    • pp.157-164
    • /
    • 2005
  • Existing models that predict of Daily water supply include statistical models and neural network model. The neural network model was more effective than the statistical models. Only neural network model, which predict of Daily water supply, is focused on estimation of the operational control. Neural network model takes long learning time and gets into local minimum. This study proposes Neuro Genetic hybrid model which a combination of genetic algorithm and neural network. Hybrid model makes up for neural network's shortcomings. In this study, the amount of supply, the mean temperature and the population of the area supplied with water are use for neural network's learning patterns for prediction. RMSE(Root Mean Square Error) is used for a MOE(Measure Of Effectiveness). The comparison of the two models showed that the predicting capability of Hybrid model is more effective than that of neural network model. The proposed hybrid model is able to predict of Daily water, thus it can apply real time estimation of operational control of water works and water drain pipes. Proposed models include accidental cases such as a suspension of water supply. The maximum error rate between the estimation of the model and the actual measurement was 11.81% and the average error was lower than 1.76%. The model is expected to be a real-time estimation of the operational control of water works and water/drain pipes.

A Study on the Simple Piped Water Supply System in a Rural Area (일부 농촌지역의 간이 상수도 운영실태와 개선 방안에 관한 조사연구)

  • 정문호
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.1
    • /
    • pp.57-66
    • /
    • 1991
  • This study was carried out for 5 years between 1984 and 1986 and 1989 and 1990. This interviewers visited 292 households to evaluate the perception of the residents using .the. Simple Piped Water Supply (SPWS), and examined the pollution source surrounding 42 SPWS facilities and water quality by the chemical and microbiological method. The purpose of this study was to find out problems linked with SPWS and to investigate more efficient way of improvement in rural water supply. The results of the study are surmnarized as follows: 1) Approximately 55% of the sampled population have been served by simple piped water supply. 2) The drinking water was mostly taken from the springs in 16 sites and valley water in 26 sites. 3) Considering the type of distribution of the SPWS, there are 28 natural gravity systems and 14 pumping systems. 4) Out of the 180 SPWS in Chun Sung Area, 74% of the SPWS facilities were used more than ten years. In addition, 40% of residents expressed the need for repairs of old facilities. 5) 48% of the SPWS facilities are neighbored with pollution source. 6) 50% of the maintenance crews were not committed totheir job but instead, the facilities were operated by some residents or community leaders who were personally concerned about quality of the facilities. 7) About 85% of the residents answered that SPWS was convenient and helpful. 8) About 57% of the residents complaind that the amount of daily water supply is not adequate. 9) About 74% of the residents felt that the water quality is high for dringking water and therefore, 52% of the facilities were not properly chlorinated. But in contrast, the biochemical tests indicated that only 28% of the SPWS met the dringking water quality standards. 10) Maintenance cost per a household ranges form 500 to 2, 000Won (1 $ = 700 Won) a month. Most of the cost was to cover the power electric charge. For the effective maintenance and arrangement of the facilities, gorvermental financial support for the maintenance is strongly recommended.

  • PDF

Appropriate Adjustment according to the Supply and Demand Status and Trend of Doctors (의사 인력의 수급 현황과 추세에 따른 적정 조정)

  • Yun Hwa Jung;Ye-Seul Jang;Hyunkyu Kim;Eun-Cheol Park;Sung-In Jang
    • Health Policy and Management
    • /
    • v.33 no.4
    • /
    • pp.457-478
    • /
    • 2023
  • Background: This study aims to contribute to the adjustment of the appropriate doctor manpower by analyzing the distribution, supply and demand, and estimation of the doctor manpower. Methods: This study utilized the medical personnel data of the Ministry of Health and Welfare, population trend data of the National Statistical Office, and health insurance benefit performance data of the National Health Insurance Service. Based on 2021, we compared the number of doctors in actual supply and the number of doctors in demand according to the amount of medical use by gender and age for 250 regions. Logistic regression analysis and scenario analysis were performed to estimate the future medical workforce by considering the demand for doctors according to the future demographic structure, the size of the quota in medical schools, and the retirement rate. Results: There were 186 regions in which the supply of doctors was below average, and the average ratio of the number of doctors in supply to demand in the region was 62.1%. Conclusion: In order to increase the number of active doctors nationwide to at least 80%, 7,756 people must be allocated. The number of doctors in demand is estimated to decrease after increasing to 1.492 times in 2059. The future projected number of doctors is expected to increase to 1.349 times in 2050 and then decrease taking into account the doctor quota and the retirement rate.

A Study on the Drinking Water Quality and Problem of Simple Piped Water Supply System in a Rural Area (일부 농촌지역 간이상수도의 운영실태와 수질에 관한 조사연구)

  • 김영규
    • Journal of Environmental Health Sciences
    • /
    • v.18 no.2
    • /
    • pp.39-51
    • /
    • 1992
  • This study was carried out for 1 year between 1990 and 1991. The interviewers visited 513 households to evaluate the perception of the residents using the Simple Piped Water Supply (SPWS), and examined the pollution source surrounding 48 SPWS facilities and water quality by the chemical and microbiological method. The purpose of this study was to find out problems linked with SPWS and to investigate more efficient way of improvement in rural water supply. The results of the study are summarized as follows: 1) Approximately 44.0% of the sampled population have been served by simple piped water supply. 2) The drinking water was mostly taken from the springs in 8 sites and valley water in 40 sites. 3) Considering the type of distribution of the SPWS, there are 40 natural gravity systems and 8 pumping systems. 4) Out of the 180 SPWS in Chun Sung Area, 73.9% of the SPWS facilities %'ere used more than ten years. 5) 47.4% of the SPWS facilities are neighbored with pollution source. 6) 42.4% of the maintenance crews were not committed to their job but instead, the facilities were operated by some residents or community leaders who were personally concerned about quality of the facilities. 7) About 36.9% of the residents complaind that the amount of daily water supply is not adequate. 8) About 55.6% of the residents felt that the water quality is good for drinking water and therefore, But in contrast, the biochemical tests indicated that most of the SPWS met the drinking water quality standards. 9) Under the present water analysis system, The method of sampling and analysis are not effective, so that analysis system shoud be done by local health center.

  • PDF