• Title/Summary/Keyword: Ammonia gas removal

Search Result 121, Processing Time 0.03 seconds

An Experimental Study on the Fundamental Properties of Zeolite Concrete (제올라이트 콘크리트의 기초 물성에 관한 실험적 연구)

  • Jo, Byung Wan;Choi, Ji Sun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • Since the cement industry is expected to face serious setbacks in the near future associated with environmental concerns. With the advent of new technologies and increased public awareness about global environmental issues, the cement industry is actively seeking to adopt new technologies as part of an effort to diversity its resources. This study is designed to assess the fundamental properties of zeolite cement concrete which consists mainly of natural zeolite, which is known for removal of and harmful gas, ion exchange capacity removing cation contaminant including heavy metals and ammonia, absorptive capacity and molecular sieving effect together with excellent insulation capacity as a porous material, and recently draws much attention for its possibility as an alternative material to cement. The study was conducted to show the compressive strength of concrete, slump, bleeding and air volume according to the changes of natural zeolite and alkali activator(NaOH). As a result of measuring the compressive strength of natural zeolite concrete, it was almost 40MPa and displayed similar to general concrete in the tests of slump, bleeding and air volume, with which it was considered that it may be used as a future high performance, high performance construction material.

Analysis of the current status and implications of nitrogen recovery from livestock manure (가축분뇨로부터 질소 회수 연구 현황 및 시사점 분석)

  • Im, Seongwon;Kim, Sangmi;Kim, Jimin;Kim, Dong-Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.29 no.1
    • /
    • pp.37-46
    • /
    • 2021
  • Nitrogen and phosphorus in livestock manure are environmental pollutants, but also could be valuable industrial resources. In the present study, we (1) introduced various nitrogen removal technologies such as stripping, thermal method, membrane, and electrodialysis, (2) reviewed relevant studies reported in 2011-2020, in particular, full-scale experiences, and (3) assessed each technologies based on the above survey results. In addition, we provided the information on the appropriate range of the pH, temperature, gas and liquid ratio, and so on in ammonia stripping process, and expected mass balance when it is connected to biogasification process. We hope the content herein can be helpful for making policy and operating full-scale plant in Korea.

The Optimization of Ozone Solubility and Half Life Time in Ultra Pure Water and Alkaline Solution on Semiconductor Wet Cleaning Process (반도체 습식 세정 공정 중 상온의 초순수와 염기성 수용액 내에서 오존의 용해도 최적화)

  • Lee Sang-Ho;Lee Seung-Ho;Kim Kyu-Chae;Kwon Tae-Young;Park Jin-Goo;Bae So-Ik;Lee Gun-Ho;Kim In-Jung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.4 no.4 s.13
    • /
    • pp.19-26
    • /
    • 2005
  • The process optimization of ozone concentration and half life time was investigated in ultra pure water and alkaline solutions for the wet cleaning of silicon wafer surface at room temperature. In the ultra pure water,. the maximum concentration (35 ppm) of ozone was measured at oxygen flow rate of 3 liters/min and ozone generator power over 60%. The half life time of ozone increased at lower power of ozone generator. Additive gases such as $N_2$ and $CO_2$ were added to increase the concentration and half life time of ozone. Although the maximum ozone concentration was higher with the addition of $N_2$ gas, a longer half life time was observed with the addition of $CO_2$. When $NH_4OH$ of 0.05 or 0.10 vol% was added in DI water, the pH of the solution was around 10. The addition of ozone resulted in the half life time less than 1 min. In order to maintain high pH and ozone concentration, ozone was continuously supplied in 0.05 vol% ammonia solutions. 3 ppm of ozone was dissolved in ammonia solutions. The static contact angle of silicon wafer surface became hydrophilic. The particle removal was possible alkaline ozone solutions. The organic contamination can be removed by ozonated ultra pure water and then alkaline solution containing ozone can remove the particles on silicon surface at room temperature.

  • PDF

A Study on Livestock Odor Reduction Using Water Washing System (수세탈취시스템을 이용한 축산악취저감에 관한 연구)

  • Jeon, Kyoung-Ho;Choi, Dong-Yoon;Song, Jun-Ik;Park, Kyu-Hyun;Kim, Jae-Hwan;Kwag, Jung-Hoon;Kang, Hee-Sul;Jeong, Jong-Won
    • Journal of Animal Environmental Science
    • /
    • v.16 no.1
    • /
    • pp.21-28
    • /
    • 2010
  • The odor problem in the livestock is increasing by 7% annually. Most importantly, the livestock odor problem in swinery accounts for the maximum ratio (54%). In this study, we reviewed the possibility of deodorizing swinery using an odor reduction device that can be used with the water washing system. First, the study confirmed that the solubility of odor gas, which was hydrogen sulfide, was very low regardless of the contact time with solvent, but the solubility of methyl mercaptan was found to increase along with the increase in time. The solubility of other odor gases, such as dimethyl sulfide, dimethyl disulfide and ammonia, was considerably high. Consequently, it is considered that if the odor reduction device for the water washing system deodorization is used in a swinery, the time during which the exhaust gas is in contact with usable water must be extended, or solvent quantity must be expanded. However, it is predicted that although hydrogen sulfide is easily generated in the anaerobic condition, it is difficult to expect high odor reduction efficiency because this gas has low solubility in water, especially in case it is used in the deodorization of the water washing system. The result of the solubility experiment using the bench-scale device practically manufactured represented the higher odor reduction ratio than expected. This result was possible because the removal efficiency of dust particles could be reached up to 93%. Therefore, it is judged that also the odor gas absorbed on dust particles could be removed by removal of dust. Consequently, it is expected that the higher order reduction ratio will be possible by structural improvement for increasing contact with water and odor gas.

Distribution and Characterization of Heterotrophic Bacteria Isolated from Deodorizing Biofilters of a Nightsoil Treatment Plant (분뇨처리장의 질소성 악취물질처리를 위한 생물탈취탑내 종속영양세균의 분포 및 특성)

  • Chung, H.M.;Kweon, O.Y.;Kim, D.B.;Ryu, J.K.
    • Korean Journal of Microbiology
    • /
    • v.34 no.4
    • /
    • pp.200-206
    • /
    • 1998
  • The distributions and characteristics of bacteria on the deodorizing biofilters were studied as a part of biofiltration research for odor gas removal. The odor gas originated from a currently operating nightsoil treatment plant were mainly nitrogenous compounds of ammonia and amines. The filter media were consisted various ratio of pine bark, nightsoil cast and compost, and were sampled before and after operation of 153 days. Before operation, the level of bacteria on nitrification agar medium, nutrient agar medium and thiosulfate agar medium were around $10^7{\sim}10^8cfu/g$ media. After operation, the level decreased but still high as $10^5{\sim}10^7cfu/g$ media. The bacteria from reactors before and after operations were either rod or coccus after growth on nitrification agar media. The 45 isolated heterotrophic bacteria were further characterized and Pseudomonas, Bacillus, Flavobacterium, Alcaligenes were dominant genera. Genus Alcaligenes was particularly dominant when the isolates were incubated on nitrification agar media first and then transfered to nutrient media. The portion of Alcaligenes in the biofilter increased after operation, and was higher in the media contained nightsoil cast, which showed better treatment than the media with pine bark only.

  • PDF

An Air Cleaning Efficiencies of Wet Air Cleaner in the Swine Finishing Winch Curtain Stall (윈치커튼식 비육돈사에서 습식공기정화기의 공기정화 효율 분석)

  • Oh, I.H.;Kim, W.G.;Lee, H.S.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.2
    • /
    • pp.75-80
    • /
    • 2008
  • High concentration of $NH_3$, $CO_2$, and lots of dust are found in modern densely raising stall system, as results, they provide a negative influence on animal and lamer health, and production ability. Therefore, it is necessary to keep clean the inside of stall air to increase the productivity. A wet type air cleaner has been developed to clean the stall air. The work principle is that the inside air are sucked through the fan, and the rotating discs make a water into a fineness spray and blows into the stall. The spray can take the dust, $NH_3$, and odor from the stall inside air and give back to the circulating water, which can be refreshed in 2 hours interval. In the Present study, we measured the $NH_3$, dust, odor, temperature and humidity in a swine stall that were installed two wet air cleaners with 700 fattening swine with on-mode and off-mode of wet air cleaners. In fall, the concentrations of $NH_3$ in off-mode stall were maximum 24 ppm and minimum 16 prm, and the average was 18.2 ppm. However in on-mode stall the $NH_3$ concentrations were maximum 7ppm and minimum 1ppm, and the average was 2.7ppm. The concentration of $NH_3$ in on-mode was 74% lower than off-mode stall. Odor was measured by olfactometer. In the off-mode stall, the odor unit was 3,800 OU/$m^3$, but in the on-mode stall the odor unit was 2,100 OU/$m^3$ Odor removal efficiency was about 45% in on-mode stall. The dust measure was divided into 3 categories, $PM_{10}$, $PM_{2.5}$ and $PM_{1.0}$. Whereas the $PM_{10}$ showed no significant differences between the tests, $PM_{2.5}$ and $PM_{1.0}$ in the fine particle range reduced remarkably in the on-mode.

  • PDF

Studies on the Isolation and Identification of Bacillus sp. for the Composting of Swine Manure and the Removal of Malodorous Gases from its Liquid Compost (돈분의 퇴비화를 위한 Bacillus sp.의 분리 동정 및 그 액체 비료의 악취 제거 연구)

  • 김규동;김기연;함영태
    • Korean Journal of Microbiology
    • /
    • v.40 no.2
    • /
    • pp.154-159
    • /
    • 2004
  • Bacillus species were isolated from swine manure to develope the microbial additive suitable for the rapid com-posting. The 3 of 4 isolated strains were identified as Bacillus cereus KD-2, B. pumilus KD-3, and B. licheni-formis KD-4. Bacillus sp. KD-1 was, however, not highly identical with any Bacillus sp. The isolated strains were analyzed their growth rates, enzyme activities, and antibacterial activities. The maximum growth tem-peratures of KD-1, KD-2, KD-3 and KD-4 were $45^{\circ}C$, $50^{\circ}C$, $53^{\circ}C$, and $55^{\circ}C$, respectively. The activities of pro-tease or amylase in mixed culture of 4 strains were similar in the range of $37^{\circ}C$ to $53^{\circ}C$ and activities of lipase in the range of $37^{\circ}C$ to $42^{\circ}C$ were twice higher than those of lipase in the range of $47^{\circ}C$ to $53^{\circ}C$. The antibacterial activity of KD-l, KD-2, or KD-3 against each other was not detected. That of KD-4 against KD-1, KD-2, or KD-3 was, however, detected. The organic compound and C/N ratio of compost fermented by the mixed culture were determined as 61.9% and 22.4%, respectively. The concentration of the ammonia gas was 12.35 mg/l in the liquid compost.

Evaluation of Odors and Odorous Compounds from Liquid Animal Manure Treated with Different Methods and Their Application to Soils (액상 가축분뇨의 처리 및 토양환원에 따른 악취 및 악취물질의 평가)

  • 고한종;최홍림;김기연;이용기;김치년
    • Journal of Animal Science and Technology
    • /
    • v.48 no.3
    • /
    • pp.453-466
    • /
    • 2006
  • To comply with stricter regulations provoked by increasing odor nuisance, it is imperative to practice effective odor control for sustainable livestock production. This study was conducted to assess odor and odorous compounds emitted from liquid animal manure with different treatment methods such as Fresh Manure(without treatment, FM), Anaerobic Digestion(AD) and Thermophilic Aerobic Digestion(TAD) and their application to soil. Air samples were collected at the headspace of liquid manure, upland and paddy soil, and analyzed for odor intensity and offensiveness using an olfactometry; odor concentration index using odor analyser; nitrogen-containing compound such as ammonia(NH3) using fluorescence method; and sulfur containing compounds such as hydrogen sulfide(H2S), methyl mercaptan(MeSH), dimethyl sulfide(DMS) and dimethyl disulfide(DMDS) using gas chromatography-pulsed flame photometric detector, respectively. Odor intensity, offensiveness and concentration index from TAD liquid manure was statistically lower than those from FM and AD(p<0.01). Mean concentrations of H2S, MeSH, DMS, DMDS and NH3 were 65.93ppb, 18.55ppb, 5.26ppb, 0.33ppb and 10.57ppm for liquid manure with AD; and 5.15ppb, 0.97ppb, 0.80ppb, 0.56ppb and 1.34ppm for liquid manure with TAD, respectively. More than 60% of malodorous compounds related to nitrogen and sulfur were removed by heterotrophic microorganisms during TAD treatment. When liquid manure was applied onto upland and paddy soil, NH3 removal efficiencies ranged from 51 to 94% and 22 to 91% for AD and TAD liquid manure, respectively. The above results show that liquid manure with TAD is superior to AD and FM with respect to the odor reduction and odor problem caused by land applied liquid manure is directly related to the degree of odor generated by the manure treatment method.

The Effect of SO2 and H2O on the NO Reduction of V2O5-WO3/TiO2/SiC Catalytic Filter (V2O5-WO3/TiO2/SiC 촉매필터의 NO 환원에 SO2와 H2O가 미치는 영향)

  • Ha, Ji-Won;Choi, Joo-Hong
    • Korean Chemical Engineering Research
    • /
    • v.52 no.5
    • /
    • pp.688-693
    • /
    • 2014
  • For investigating NO reduction activity of an catalytic filter, the catalytic performance was measured under the presence of $SO_2$ and $H_2O$, respectively or simultaneously in the simulation gas composed of NO, $NH_3$, and air. The catalytic filter was prepared by coating $V_2O_5-WO_3/TiO_2$ catalyst on the pore surface of SiC filter element of which the superior performance for the particulate removal was well known. At the temperature below $260^{\circ}C$, the catalytic activities were enormously decreased under the presence of $SO_2$ and $H_2O$, respectively or simultaneously, compared with those under the cases of the absence of $SO_2$ and $H_2O$. However, the presence of $SO_2$ promoted the performance of the catalytic filter above $320^{\circ}C$ with showing the NO conversion better than 99.8% for the NO inlet concentration of 500 ppm and at the face velocity of 2 cm/s. In particular, the presence of water showed high NO conversion higher than 99% up to high temperature of $380^{\circ}C$. This effect of water was explained by the reason that it retarded the ammonia oxidation which is the main step into the formation of $N_2O$. The initial NO reduction activity of the catalytic filter maintained for the duration of 100 hours in the presence of $SO_2$ and $H_2O$. Therefore, it was concluded that the catalytic filter was promisingly useful for the industrial NOx reduction catalyst in order to treat the particulate and NO simultaneously.

Decomposition of odor using atmospheric-pressure plasma (플라즈마를 이용한 악취물질 분해 특성)

  • Kang, Seok-Won;Lee, Jae-Sik;Lee, Kang-San;Lim, Hee-Ah;Kim, Ji-Seong;Lee, Jeong-Dae;Park, Wol-Su;Park, Young-Koo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.708-718
    • /
    • 2020
  • Offensive odor is recognized as a social environmental problem due to its olfactory effects. Ammonia(NH3), hydrogen sulfide(H2S) and benzene(C6H6) are produced from various petrochemical plants, public sewage treatment plants, public livestock wastes, and food waste disposal facilities in large quantities. Therefore efficient decomposition of offensive odor is needed. In this study, the removal efficiency of atmospheric-pressure plasma operating at an ambient condition was investigated by evaluating the concentrations at upflow and downflow between the plasma reactor. The decomposition of offensive odor using plasma is based on the mechanism of photochemical oxidation of offensive odor using free radical and ozone(O3) generated when discharging plasma, which enables the decomposition of offensive odor at ordinary temperature and has the advantage of no secondary pollutants. As a result, all three odor substances were completely decontaminated within 1 minute as soon as discharging the plasma up to 500 W. This result confirms that high concentration odors or mixed odor materials can be reduced using atmospheric-pressure plasma.