• 제목/요약/키워드: Ambient measurement

검색결과 500건 처리시간 0.025초

완전제어형(完全制御型) 실험용(實驗用) 작물생육장치(作物生育裝置)의 개발(開發)(I) -온(溫)·습도(濕度) 제어(制御) 시스템- (Development of a Fully-Controlled Phytotrons -Temperature and Humidity Control System-)

  • 이규철;유관희;노상하;홍순호
    • Journal of Biosystems Engineering
    • /
    • 제17권1호
    • /
    • pp.55-64
    • /
    • 1992
  • The aim of this study was to develop a phytotron for studying the effects of environmental factors such as temperature and humidity on plant growth. This equipment consists of the growth chamber, and the measurement and control system including control algorithms required for optimum operation. As the first step of the study, a temperature and humidity control system was developed. The results of this study are summarized as follows ; 1. Pt-100 was selected to measure temperature and a linearized op-amp circuit was developed for signal conditioning. 2. Pt-100 wet bulb thermometer based on Asmann's principle was developed to measure relative humidity. 3. Temperature and relative humidity conditions were controlled by ON-OFF and PWM operation using a PID controller. And an autotuning algorithm using the characteristics of step response was developed to determine optimal PID constants which were independent of the size of apparatus and environmental factors. 4. Under the ambient temperature of $20^{\circ}C{\sim}25^{\circ}C$, the temperature was kept within the error of ${\pm}0.3^{\circ}C$ in the range of $10^{\circ}C{\sim}40^{\circ}C$, and the relative humidity was kept within the error of ${\pm}5%$ in the range of ${\pm}50%{\sim}90%$.

  • PDF

ALD법을 이용해 증착된 TaN 박막의 Cu 확산방지 특성 (Characteristics of TaN by Atomic Layer Deposition as a Copper Diffusion Barrier)

  • 나경일;허원녕;부성은;이정희
    • 센서학회지
    • /
    • 제13권3호
    • /
    • pp.195-198
    • /
    • 2004
  • For a diffusion barrier against copper, tantalum nitride films have been deposited on $SiO_{2}$ by atomic layer deposition (ALD), using PEMAT(Pentakis(ethylmethylamino)tantalum) and $NH_{3}$ as precursors, Ar as purging gas. The deposition rate of TaN at substrate temperature $250^{\circ}C$ was about $0.67{\AA}$ per one cycle. The stability of TaN films as a Cu diffsion barrier was tested by thermal annealing for 30 minutes in $N_{2}$ ambient and characterized through XRD, sheet resistance, and C-V measurement(Cu($1000{\AA}$)/TaN($50{\AA}$)/$SiO_{2}$($2000{\AA}$)/Si capacitor fabricated), which prove the TaN film maintains the barrier properties Cu below $400^{\circ}C$.

Rhombohedral - Boron Phosphide 의 저온 증착과 물성분석 (The Deposition of Rhombohedral - Boron Phosphide at Low Temperature and its Analysis of Physical Properties)

  • 홍근기;윤여철;복은경;김철주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.27-30
    • /
    • 2002
  • Boron Phosphide films were deposited on the glass substrate at the low temperature, $550^{\circ}C$, $480^{\circ}C$, by the reaction of $B_{2}H_{6}$, with $PH_{3}$ using CVD. The reactant gas rates were 50 cc/min and 20 cc/min for $B_{2}H_{6}$, 50 cc/min and 40 cc/min for $PH_{3}$ and $1.5\ell$/min for $N_{2}$ carrier gas. The films were annealed for 1hour, 3hours in $N_{2}$ ambient at $550^{\circ}C$ and $400^{\circ}C$. The deposition rate was $1000{\AA}$/min and the refractive index of film was 2.6. From results of XRD measurement the films have the preferred orientation of (1 0 1). For as deposited the film, the data of VIS spectrophotometer show 75.49%, 76.71% for 1hr-annealed and 86.4% for 3hrs-annealed. From AFM datas the surface condition of obtained films are was shown $73{\AA}$, $88.9{\AA}$ and $220{\AA}$ for as-deposited, for 1hr-annealed and for 3hr annealed, respectively.

  • PDF

Correlations for Prediction of Non-evaporating Diesel Spray Penetration

  • No, Soo-Young
    • 한국분무공학회지
    • /
    • 제12권3호
    • /
    • pp.146-153
    • /
    • 2007
  • The prediction of diesel spray penetration has been the subject of several works and intensive investigations are still underway by many researchers. It is required to summarize the correlations developed before 1990 days and to introduce the correlations reported recently in the literature. The existing zero-dimensional models for the prediction of diesel fuel spray penetration can be classified as theoretical and empirical correlations. Of various correlations, the models considered in this paper were selected as based on the evaluation results of previous reviews and the recently published works in the literature. The existing theoretical correlations can be classified into seven categories and the existing empirical ones as two categories in this review. According to the review of existing models, the dominating factors for the prediction of spray tip penetration are the spray angle, discharge coefficient, pressure drop across nozzle, ambient density and orifice diameter and time after the start of injection. Especially, the definition for the measurement of spray angle is different with researchers. It is required to evaluate the existing spray tip penetration models for the very high injection pressure and other fuel sprays such as DME. It is also required to evaluate the correlations for the prediction of diesel spray penetration with the connection of liquid-phase penetration.

  • PDF

시화.반월단지지역의 고농도 오존일에 대한 광화학모델 적용 연구 - 기상특성에 대한 분석 - (A study on high ozone concentration in Shiwha.Banwol industry complex using photochemical air pollution model- Analysis of meteorological characteristics -)

  • 안재호
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.47-59
    • /
    • 2011
  • The purpose of this paper is to simulate the high ozone concentration in Shiwha Banwol indusrial complex. High pollution episodes (ozone alert) of this area are the results of geographical location and its air pollutants emission. This research has used meteorological model (RAMS) and photochemical air pollution Model (CIT model). As first step of the evaluate of this combined model system simulations are done in terms of meteorological characteristics like wind fields, PBL-height, etc.. Numerical simulations are carried out with real meteorological synoptic data on June. 24-25, 2010. In comparison with real measurement and another research the model reflects well local meteorological phenomena and shows the possibility to be utilized to analyse the pollutant dispersion over irregular terrain region. The high ozone concentration is deeply correlated to the ambient air temperature, wind speed and solar radiation. Local meteorological phenomena like sea-land breeze impact on horizontal dispersion of ozone. This analysis of meteorological characteristics can, in turn, help to predict their influences on air quality and to manage the high ozone episodes.

대구지역 주요 도로변 대기오염물질의 농도 특성 (Characteristics of Air Pollutant Concentrations Near Major Roadways in Daegu)

  • 조완근;최성락
    • 한국환경과학회지
    • /
    • 제15권8호
    • /
    • pp.737-744
    • /
    • 2006
  • Present study was designed to characterize the concentrations of major roadside air pollutants in Daegu and to compare with those of Seoul and Busan. Evaluated were the exceedance frequence of mean concentrations of target compounds(CO, NO$_2$, O$_3$, PM$_{10}$, SO$_2$) and the relationship for time variation. Two air pollution monitoring stations(one roadside station and one residential station) in Daegu were selected for this study. In addition, one roadside monitoring station from each of Seoul and Busan was chosen for the comparison of Daegu monitoring stations. The data analyzed in the current study were collected from 1998 to 2000 by Daegu Regional Environmental Management Office. The roadside concentrations of NO2 and PM to and the exceedance frequency of ambient air standard levels in Daegu were higher than those of Seoul and Busan. Except 03, the roadside concentrations of all target compounds showed following three distinguished patterns; first, possibly due to increased traffic density, the concentrations increased from 0500 to 0900(LST), second, the concentrations decreased from 0900 to 1700(LST) possibly due to the increased wind velocity and decreased traffic density, and finally, increased traffic density, the concentrations increased again from 1700 to 2100(LST). An implication was that major air pollution sources shifted from residential area to road-area during rush hours.

팔당호로의 질소와 황성분 침적 측정 (Measurement of Nitrogen and Sulfur Deposition to Lake Paldang)

  • 김영성;진현철
    • 한국대기환경학회지
    • /
    • 제21권1호
    • /
    • pp.39-48
    • /
    • 2005
  • Nitrogen and sulfur deposition was measured on Lake Pal dang from March 2002 to October 2003. Wet and dry depositions were separately measured using wet- and dry-only samplers, respectively. In order to measure the dry deposition to the water body, a dry deposition sampler composed of three pans filled with pure water, called the deposition water, was used. Since ammonium was generally in excess in ambient air, more than half of ammonium was present in the gaseous form. Ammonium concentration was also generally higher than the sum of major anion concentrations in the deposition water because gaseous species were much easily deposited than the species in fine particles. Nevertheless, the contribution of gaseous ammonia to the deposition of ammonium was not high as well as that of particulate ammonium while the contribution of gaseous nitric acid was much higher than that of particulate nitrate. Annual wet deposition fluxes of nitrogen and sulfur were five and six times higher than their dry deposition fluxes, respectively. Except for ammonium, the dry deposition flux estimated in the present work was a half of the previous results. This was mainly caused by much smaller dry deposition velocities over the water than over the ground.

건전도 감시용 자립형 계측유닛을 위한 진동발전시스템 (Vibration Powered Generator System for Stand-Alone Health Monitoring Sensor Unit)

  • 최남섭;김재민
    • 한국지진공학회논문집
    • /
    • 제7권2호
    • /
    • pp.85-92
    • /
    • 2003
  • 본 논문에서는 교량의 건전도 감시용 자립형 계측유닛을 위한 교량의 상시진동을 이용한 진동발전시스템을 제시하였다. 본 연구에서는 전기자 반작용의 영향을 최소화한 새로운 구조의 진동발전기를 제안하고, 기계적 및 전기적인 설계식을 유도한 다음, 시험용 진동발전기를 제작하였다. 또한, 매우 작은 발전 전류의 축전시스템에 대하여 고찰하고 개선점을 도출하였다. 축전시스템에 대한 고찰 결과, 정류기에 사용된 다이오드 특성이 충전과정에서 지배적임을 밝혔다. 마지막으로, 진동발전시스템 모델에 실측 남해대교 가속도 데이터를 적용한 시뮬레이션과 실내 실험을 수행하였고, 제작된 시험용 진동발전기의 적용성과 효용성을 확인할 수 있었다.

Metamorphic HEMT에서 low-k Benzocyclobutene (BCB)를 이용한 표면 passivation 비교 연구 (Comparative study of surface passivation for Metamorphic HEMT using low-k Benzocyclobutene(BCB))

  • 백용현;오정훈;한민;최석규;이복형;이성대;이진구
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.471-472
    • /
    • 2006
  • The passivation technology is very important, because this technology can protect a device against the influence of ambient environment, and prevent the performance reduction. In this paper, we fabricated the $0.1{\mu}m\;{\Gamma}$-gate InAlAs/InGaAs metamorphic high electron mobility transistors (MHEMTs) on GaAs substrates using the low-k benzocyclobutene (BCB) and $Si_3N_4$ as a passivation and we performed the comparisons of characteristics of the MHEMTs. After passivation, the DC and RF measurement results were decreased either the conventional Si3N4 or BCB layers. The decrement of the BCB passivation was smaller than the $Si_3N_4$ passivation.

  • PDF

Characteristics of Aerosol Composition at Jeju City, Korea

  • Hu, Chul-Goo;Lee, Ki-Ho;Oh, Tae-Gwon;Kang, Chun-Hee;Yang, Soon-Mi
    • 한국환경과학회지
    • /
    • 제12권5호
    • /
    • pp.541-549
    • /
    • 2003
  • Aerosol measurement were carried out to investigate the characteristics of its chemical composition directly affected by the local emissions of Jeju City, Jeju Island by using an eight-stage cascade impactor from Dec. 1999 to Aug. 2000. The ambient aerosol concentrations measured at Jeju City were generally very low but the fine particle concentrations were to be higher than the US standard of PM2.5. The majority of sulfate were non sea salt and contained in the fine particles. In the fine particles, the concentrations of Na$\^$+/, K$\^$+/, Mg$\^$2+/, Ca$\^$2+/, Cl$\^$-/ and NO$\sub$3$\^$-/ had a tendency to increase during the springtime rather than the other seasons. However, the springtime sulfate and ammonium concentrations in the fine particles were slightly lower than those during the other seasons. On the other hand, associated with the coarse particles, the concentrations of ionic species except potassium and ammonium were elevated during the springtime. The calcium concentrations in the coarse particles were increased up to 8 times relative to the other seasons.