• 제목/요약/키워드: Ambient air quality

검색결과 291건 처리시간 0.023초

A Study on Acute Effects of Ambient Air Particles on Pulmonary Function of Schoolchildren in Ulsan

  • Yu, Seung-Do;Kim, Dae-Seon;Cha, Jung-Hoon;Ahn, Seung-Chul;Lee, Jong-Tae
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2003년도 Challenges and Achievements in Environmental Health
    • /
    • pp.183-186
    • /
    • 2003
  • To evaluate the effect of air pollution on respiratory health in children, we conducted a longitudinal study in which children were asked to record their daily levels of peak expiratory flow rate using potable peak flow meter (mini-Wright) far 4 weeks. The relationship between daily PEFR and ambient air particle levels was analyzed using a mixed linear regression models including gender, age in you, weight, the presence of respiratory symptoms, and relative humidity as an extraneous variable. The daily mean concentrations of PM$\_$10/ and PM$\_$2.5/ over the study period were 64.9$\mu\textrm{g}$/㎥ and 46. l$\mu\textrm{g}$/㎥, respectively. The range of daily measured PEFR in this study was 170-481 l/min. Daily mean PEFR was regressed with the 24-hour. average PM$\_$10/ (or PM$\_$2.5/) levels, weather information such as air temperature and relative humidity, and individual characteristics including sex, weight, and respiratory symptoms. The analysis showed that the increase of air particle concentrations was negatively associated with the variability in PEFR. We estimated that the IQR increment of PM$\_$10/ or PM$\_$2.5/ were associated with 1.5 l/min (95% Confidence intervals -3.1, 0.1) and 0.8 l/min (95% Cl -1.8, 0.1) decline in PEFR. Even though this study shows negative findings on the relationship between respiratory function and air particles, it is worth noting that the findings must be interpreted cautiously because exposure measurement based on monitoring of ambient air likely results in misclassification of true exposure levels and this is the first Korean study that PM$\_$2.5/ measurement is applied as an index of air particle quality.

  • PDF

Canister와 GC/MSD를 이용한 대기 중 VOCs 분석시스템의 정도관리(QC) (Quality Control(QC) Analysis of Ambient VOCs in Canisters Using GC/MSD Method)

  • 전준민;허당;김동술
    • 한국대기환경학회지
    • /
    • 제18권6호
    • /
    • pp.527-538
    • /
    • 2002
  • In this study, the performance of sampling and of analytical methodology was examined against a number of selected volatile organic compounds (VOCs) in the ambient air. The canister-based sampling method for VOCs has been a viable and widely used approach that is based on research and evaluation performed over the past several years. VOCs were determined using canisters by GCMSD analysis. A total of target analyses in this study included approximately 30 VOCs designated in TO-l4A categories including BTEX. The methodology for QC(quality control) was intensively investigated with a wide range of performance criteria such as; (1) cleanliness of canisters, (2) reproducibility of diluter, (3) instrumental detection limits of preconcentrator and GCMSD, and (4) precision and accuracy of GCMSD. For most of the compounds tested, precision was less than $\pm$5%, IDL was 0.2 ppbv, accuracy was $\pm$5%, respectively. This study demonstrated that the combination of canister sampling and GC/MSD analysis could be reliably applied to the measurements of BTEX in ppbv levels that are typically observed in/outdoor air environment.

대기온도에 따른 휘발유 자동차의 배출가스 특성에 관한 연구 (A Study on the exhaust gas characteristics of the vehicle gasoline according to the ambient temperature)

  • 임재혁;김기호;김성우;이민호;오상기
    • 동력기계공학회지
    • /
    • 제19권6호
    • /
    • pp.47-53
    • /
    • 2015
  • Korea is the geographic location during the summer, the temperature rising to $35^{\circ}C$ and winter temperature is $-15^{\circ}C$ to reduce the air temperature changes, such as relatively large compared to other countries. This increase or decrease of the harmful exhaust gas discharged from automobile substantially inconvenience a significant impact on the active side of the car engine temperature and exhaust gas reducing device receives a large impact on the atmospheric temperature is regulation to be different. However, domestic vehicle emissions test temperature of $20{\sim}30^{\circ}C$ is it does not reflect this situation the actual test temperature to accurately measure the exhaust gas volume of the vehicle is difficult. In this study, domestic automobile exhaust gas test conditions of a test temperature $20{\sim}30^{\circ}C$ various temperatures, including (35, 25, 0, -7, -15, $-25^{\circ}C$) under the two vehicles (2.0L MPI, 2.4 L GDI) as was discussed with respect to the exhaust gas characteristics of the vehicle according to the ambient temperature gas. As a result, domestic emissions test temperature of $25^{\circ}C$ than average conditions were temperature decreases greenhouse gas emissions and increase overall increased by up to 15 times higher. Air temperature and the engine exhaust gas inconvenience a direct effect on the activation temperature required in the reduction unit is determined to be an increase of emissions and greenhouse gases, and also an increase in the variety of lubricants based lubricating and viscosity reduction, such as the engine oil due to the low temperature of these result It is considered that shows the.

Si(111) 기판 위에 증착된 ZnO 박막의 열처리 분위기에 따른 구조적, 광학적 특성 연구 (Effect of Ambient Gases on Thermal Annealed ZnO films deposited on Si(111) Substrates)

  • 이주영;김홍승;정은수;장낙원
    • 한국전기전자재료학회논문지
    • /
    • 제18권8호
    • /
    • pp.734-739
    • /
    • 2005
  • Zinc oxide films were deposited on Si (111) substrates by radio-frequency (rf)sputtering at a room temperature and post annealed in Na, air, and $H_2O$ ambient at temperatures between $800{\circ}C$ for 2 hrs. The properties were investigated by atomic force microscope (AFM), X-ray diffraction (XRD), Auger electron spectroscopy (AES) and photoluminescence (PL). Our experiments demonstrated that ZnO films have the better crystal quality for post thermal annealing and especially in $H_2O$ ambient. Even though thermal annealing reduced deep level emission somewhat, for further getting rid off deep level emission, oxygen contents should be adjusted. In our results, $H_2O$ ambient gave the best structural and optical properties.

서울시 주요 도로변 대기중 납, 아연 및 철 농도에 관한 조사연구 (A study on Pb, Zn and Fe Concentrations of Ambient Air Adjacent to Heavy Traffic Road Side in Seoul)

  • 조준호;박석환;정문식
    • 한국환경보건학회지
    • /
    • 제24권2호
    • /
    • pp.110-117
    • /
    • 1998
  • This study was carried out to investigate the concentrations of TSP, Pb, Zn and Fe in ambient air adjacent to the heavy traffic road side in Seoul from October 1 to October 31, 1997. The results were as follows 1. The concentrations of TSP were 260 $\mu g/m^3$, 184 $\mu g/m^3$, 147 $\mu g/m^3$ in Chongro, Chungkechun and Kangnam-terminal, respectively. The concentration of TSP was correlated with the traffic volume of the sampling sites (r=0.77). 2. The concentrations of Pb were 638 ng/m$^3$, 335 ng/m$^3$, 233 ng/m$^3$ in Chungkechun, Kangnam-terminal and Chongro, respectively. The concentration of Pb was correlated with the Truck (over 1.4 ton) volume of the sampling sites (r=0.71). The Pb contents among these sites were significantly different (p < 0.05). 3. The concentrations of Zn were 535 ng/m$^3$, 461 ng/m$^3$, 439 ng/m$^3$ in Chongro, Kangnam-terminal and Chungkechun, respectively. The concentration of Zn was badly correlated with the traffic volume of the sampling sites (r=0.23). 4. The concentrations of Fe were 5.32 $\mu g/m^3$, 4.51 $\mu g/m^3$ and 3.18 $\mu g/m^3$ in Chongro, Kangnam-terminal and Chungkechun, respectively. The concentration of Fe was correlated with the traffic volume of the sampling sites (r=0.83). The Fe contents among these sites were significantly different (p < 0.05). 5. The concentrations of TSP, Pb, Zn, Fe investigated didn't exceed the Korean Ambient Air Quality Standards, but more researches in relation to these will be required in considering people working in these sites suffered from cough, asthma and chronic headache.

  • PDF

수동측정기에 의한 대기오염 자동측정망의 지역대표성 조사 및 보완방완에 대한 기초연구 (Evaluation and Complement of the Representativeness of Air Quality Monitoring Stations Using Passive Air Samplers)

  • 우정현;김선태;김정욱
    • 한국대기환경학회지
    • /
    • 제13권6호
    • /
    • pp.415-426
    • /
    • 1997
  • Some arguments have been about over the representativeness of government-run air quality monitoring stations among scholars and non-governmental organizations (NGOs). However, it is not a simple problem to move monitoring stations because of continuity of data and high cost. So it is necessary to complement the monitoring data if it do not represent the ambient air quality properly. The purpose of this study was to evaluate the representativeness of some monitoring stations using passive $NO_2$ samplers and to find a complementary method from linear regression. Two stations were chosen for the evaluation: Shinlim Station was one of the most controversial stations in Seoul and Banpo Station had the best reputation. Air qualities were surveyed at seven points around each monitoring station with consideration of land use and distance. The ratios of the average $NO_2$ levels of the areas to these at the monitoring stations were 1.59 for Shinlim Station and 1.03 for Banpo Station. The differences between the average $NO_2$ levels and those at the monitoring stations were 10.75 ppb for Shilim Station and 0.34 ppb for Banpo Station. The correlation coefficients between the two levels were 0.7668 for Shinlim and 0.7662 for Banpo. The average coefficients of determination $(R^2)$ were 0.61 for Shinlim and 0.61 for Banpo. The Shinlim Station could not represent the air quality of Shinlim-Dong good because it is located in a green area at an outskirt of Shinlim-Dong. But the Banpo Station located in a central residential area of Banpo-Dong showed a fair representativeness. However, air quality turned out to be different with land use such as residential area, green area or road: the air quality data from a monitoring station located at a certain land use should not be interpreted as representing the air quality at any sites around the station. Equations to predict the average $NO_2$ levels of each area from the data from the monitoring stations were presented based on linear regression.

  • PDF

SP2 (Single Particle Soot Photometer)를 이용한 제주도 5월 Black Carbon 특성 (Characteristics of Black Carbon Particles in Ambient Air Using a Single Particle Soot Photometer (SP2) in May 2013, Jeju, Korea)

  • 오준;박진수;이상욱;안준영;최진수;이상덕;이용환;김현재;홍유덕;홍지형;김정호;김상우;이강웅
    • 한국대기환경학회지
    • /
    • 제31권3호
    • /
    • pp.255-268
    • /
    • 2015
  • Single particle soot photometer (SP2) is an advanced instrument capable of real-time measurement of concentration, coating thickness, and size distribution of individual BC particle using laser-induced incandescence. So far, there have been insufficient studies examining the real-time characteristics of BC in Korea. In this study, we examined temporal variations in BC concentration and mass size distribution of BC in volume equivalence diameter at a background site of Aewol, Jeju in May. Average concentration and mass median diameter (MMD) of BC particles measured during the study period (06~ 16 May 2013) were $0.69{\pm}0.48{\mu}g/m^3$ and $196{\pm}17nm$, respectively. The BC concentration measured in Aewol was very similar to that observed in the spring of 2012 in Baengnyeong island, and showed diurnal profiles similar to those in other background areas. MMD of BC ranged from 172 to 222 nm. It was found that the mass size distribution of BC varied depending on the location (ground-based), season, types of air masses, and altitude (aircraft-based).

Wafer-Level Packaged MEMS Resonators with a Highly Vacuum-Sensitive Quality Factor

  • Kang, Seok Jin;Moon, Young Soon;Son, Won Ho;Choi, Sie Young
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권5호
    • /
    • pp.632-639
    • /
    • 2014
  • Mechanical stress and the vacuum level are the two main factors dominating the quality factor of a resonator operated in the vacuum range 1 mTorr to 10 Torr. This means that if the quality factor of a resonator is very insensitive to the mechanical stress in the vacuum range, it is sensitive to mainly the ambient vacuum level. In this paper, a wafer-level packaged MEMS resonator with a highly vacuum-sensitive quality factor is presented. The proposed device is characterized by a package with out-of-plane symmetry and a suspending structure with only a single anchor. Out-of-plane symmetry helps prevent deformation of the packaged device due to thermal mismatch, and a single-clamped structure facilitates constraint-free displacement. As a result, the proposed device is very insensitive to mechanical stress and is sensitive to mainly the ambient vacuum level. The average quality factors of the devices packaged under pressures of 50, 100, and 200 mTorr were 4987, 3415, and 2127, respectively. The results demonstrated the high controllability of the quality factor by vacuum adjustment. The mechanical robustness of the quality factor was confirmed by comparing the quality factors before and after high-temperature storage. Furthermore, through more than 50 days of monitoring, the stability of the quality factor was also certified.

신축공동주택의 실내공기질 특성 및 평가 -휘발성 유기화합물 및 포름알데히드 중심으로- (Characterization and Assessment of Indoor Air Quality in Newly Constructed Apartments -Volatile Organic Compounds and Formaldehyde-)

  • 심상효;김윤신
    • 한국환경보건학회지
    • /
    • 제32권4호
    • /
    • pp.275-281
    • /
    • 2006
  • Indoor air quality is the dominant contributor to total personal exposure because most people spend a majority of their time indoors. Especially exposure to indoor air can potentially pose a greater threat than exposure to ambient air when indoor environments have sources of contaminants. In this study, volatile organic compounds (VOCs) and formaldehyde (HCHO) within newly constructed apartment have been determined in 27 houses of apartment in Seoul from December 2004 to March 2005. The measured indoor air pollutants were HCHO, volatile organic compounds including benzene, toluene, styrene, xylene, ethylbenzene and sampled on the standard method of Ministry of Environment in Korea. The indoor levels for benzene, xylene, toluene, ethylbenzene, styrene, and HCHO have significant increase trend after 5 hours closing of windows and doors. Levels of measured air pollutants concentrations between living rooms and bedrooms have not shown significant difference. Spearman correlation coefficient among the measured air pollutants ranged from 0.303 to 0.946, indicating similar source in building materials.