• Title/Summary/Keyword: Ambient air quality

Search Result 293, Processing Time 0.027 seconds

Study on the Long Term Storage of Garlic Bulbs -Part 1. The Effects of Post-harvest Drying Method and Storage Condition on the Quality- (마늘 장기(長期) 저장(貯藏) 방법(方法) -제일보(第-報). 예건처리방법(豫乾處理方法)과 저장조건(貯藏條件)이 품질변화(品質變化)에 미치는 영향(影響)-)

  • Park, Mu-Hyun;Koh, Ha-Young;Shin, Dong-Hwa;Suh, Kee-Bong
    • Applied Biological Chemistry
    • /
    • v.24 no.4
    • /
    • pp.218-223
    • /
    • 1981
  • This study was conducted to investigate the effects of post-harvest drying method and subsquent storage condition on the quality of garlic bulbs for 10 months from July, 1980 to April, 1981. The 27% weight loss of garlic bulbs by HPHD (hot air post-harvest frying) for 12 days at $40^{\circ}C$ (8hrs/day) was equal to that by NPHD (conventional natural post-harvest drying) for 35 days. But the decay occured 5.5% only in NPHD. During the storage period of garlic bulbs by HPHD, their decay and weight ]oss were less 25.4% and 13.5% in ambient storage, and less 14.2% and 7.5% in low temperature storage than those of NPHD. When garlic bulbs were stored in low temperature, the weight loss and decay were less 20.0% and 22.4% in NPHD, and tess 14.0% and 9.9% in HPHD than those in ambient temperature storage. The Quality of garlic bulbs packed with 0.08mm polyethylene film stored at ambient temperature for 2 months was so poor as to be inedible because of the adverse effect of $CO_2$ and the growth of molds, but in low temperature storage for 10 months it was in good shape showing the weight loss, the decay and the sprouting 2.6%, 3.4% and 26.8%, respectively.

  • PDF

Source Identification and Trends in Atmospheric Particulate-bound Mercury at Seoul and Baengnyeong, South Korea (서울과 백령도의 대기 중 입자상 수은의 분포 특성 및 발생원 추정연구)

  • Noh, Seam;Park, Kwang-Su;Kim, Hyuk;Yu, Seok-Min;Lim, Yong-Jae;Lee, Min-Do;Seok, Kwang-Seol;Kim, Younghee
    • Journal of Environmental Analysis, Health and Toxicology
    • /
    • v.21 no.4
    • /
    • pp.220-228
    • /
    • 2018
  • $PM_{2.5}$-bound mercury (PBM) was monitored at weekly intervals for three years (from 2014 to 2016) at an urban (Seoul) and rural site (Baengnyeong) in South Korea. The average PBM concentrations in $PM_{2.5}$ samples over the entire sampling period were $12{\pm}11pg/m^3$ and $36{\pm}34pg/m^3$ for Baengnyeong and Seoul, respectively. Seasonal differences were pronounced, with concentrations being highest in winter due to local meteorological conditions (high gas-particle coefficient due to low temperature and low mixing layer height in winter) as well as seasonal factors, such as coal combustion for heating purposes in China. In Baengnyeong, the significant positive correlation of PBM with $PM_{2.5}$, air pollutants, and heavy metals suggested that coal combustion in China might be the most important source of ambient mercury in Korea. In winter, no correlation of PBM with $PM_{2.5}$, air pollutants, and heavy metals was seen in Seoul. Furthermore, Seoul showed higher $PBM/PM_{2.5}$ and $Pb/PM_{2.5}$ ratios in winter due to the strong atmospheric oxidation-reduction reaction conditions as well as local and regional PBM sources. We conclude that immediate attention must be given to addressing PBM levels in Korea, including considering it as a key component of future air quality monitoring activities and mitigation measures.

Effects of Elevated Spring Temperatures on the Growth and Fruit Quality of the Mandarin Hybrid 'Shiranuhi' (봄철 가온처리가 부지화의 생장과 과실품질에 미치는 영향)

  • Moon, Young-Eel;Kang, Seok-Beom;Han, Seung-Gab;Kim, Yong-Ho;Choi, Young-Hun;Koh, Seok Chan;Oh, Soonja
    • Horticultural Science & Technology
    • /
    • v.33 no.4
    • /
    • pp.459-469
    • /
    • 2015
  • The effects of elevated spring temperatures on the growth and fruit quality of the mandarin hybrid 'Shiranuhi' [(Citrus unshiu ${\times}$ C. sinensis) ${\times}$ C. reticulata] were investigated in plastic greenhouses, to develop a cropping system to improve the quality of the fruit and increase the income of growers on Jeju Island, South Korea. Under conditions of elevated temperature I ($25/15^{\circ}C$, day/night) and elevated temperature II ($28/18^{\circ}C$, day/night) during early spring, budburst was advanced by 11 and 15 d, and full bloom by 22 and 45 d, respectively, compared to those of the plants grown at ambient air temperature in a plastic greenhouse. Elevated temperatures decreased the number of spring shoots but increased mean spring shoot length and leaf area. Growing 'Shiranuhi' trees at elevated temperatures resulted in increases in mean fruit weight and fruit L/D ratio (> 1.0). In addition, fruit color development was significantly advanced in trees grown under elevated temperatures during early spring, which allowed the fruit to be harvested 1-2 months earlier than trees grown under ambient air temperature. Fruit soluble solids content (SSC) and titratable acidity (TA) at harvest were similar between elevated temperature I and ambient air temperature, but were significantly higher than at elevated temperature II. Considering fruit quality, harvest time, and yield, the elevated temperature treatment regime of $25/15^{\circ}C$ (day/night) during early spring could be useful for cultivation of the mandarin hybrid 'Shiranuhi' to increase the income of growers.

Short-term Effect of Air Pollution on Respiratory Disease in Seoul : A Case-Crossover Study (서울지역 대기오염이 호흡기계질환에 미치는 단기영향에 관한 환자교차연구)

  • Lee, Young-Ju;Lee, Jong-Tae;Shin, Dong-Chun;Im, Hyoung-June;Cho, Soo-Hun;Ju, Young-Su
    • Journal of Preventive Medicine and Public Health
    • /
    • v.34 no.3
    • /
    • pp.253-261
    • /
    • 2001
  • Objectives : To evaluate the hypothesis that air pollution could increase emergency room visits for respiratory diseases, and if so, to quantify the strength of association between those. Methods : We compiled daily records of hospital emergency room visits for respiratory diseases in Seoul, from November 1. 1955 to October 31. 1996, by using medical utilization data of unscheduled visits. In addition, air quality and weather data for the same period was collected. And a case-crossover design was applied by adopting conditional logistic regression analysis to determine the relationship between air pollutants and emergency room visits for respiratory diseases. In particular, the control periods were chosen by a bidirectional paired matching technique 7, 14, and 21 days before and after the case periods. Results : Only ozone was associated with the increased number of emergency room visits for respiratory diseases. The relative risk according to a 30ppb increase of ozone concentration (24hr mean, lagged 1day) was 1.91(95% confidence interval = 1.78-2.05). Conclusion : There was a statistically significant association between the ambient ozone and daily emergency room visits for respiratory diseases.

  • PDF

A Study on Air Pollution in the Underground Shopping Store of Taejon Area (대전지역 지하상가의 대기오염도에 관한 조사연구)

  • 양천회;류완호;장철현
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.1
    • /
    • pp.134-139
    • /
    • 1994
  • In order to assess the level of atmospheric pollution and to contribute the hearth improvement of residents in Taejon city, the authors were measured the concentration of air pollutants(CO, SO$_2$, NO$_2$, TSP, Pb, Cd, Cr) at three places of the control road in Taejon. The investigative research performed bimonthly from May 1993 to September 1993, and the places were the underground shopping stores of Taejon station, Dongyang department store and provincial goverment areas. The results of statistical analysis are as followings. \circled1CO :0.569~0.966ppm \circled2SO$_2$:0.084~0.170ppm \circled3NO$_2$:0.0045~0.022ppm \circled4TSP:249~299$\mu\textrm{g}$/㎥. \circled5Pb :0.366~1.157$\mu\textrm{g}$/㎥. \circled6Cd:0.016~0.025$\mu\textrm{g}$/㎥. \circled7 Cr : 0.198 ~0.290$\mu\textrm{g}$/㎥. The mean concentration of SO$_2$in Dongyang department store area was 0.17ppm, and it exceeded the ambient air quality standard by 0.02ppm. The concentration of TSP was higher than a standing rule of public hygiene, and it was very near to a standing rule of environmental preservation. The standing rule of indoor air pollution in underground shopping store have two different laws, the public hygiene and the environmental preservation. Therefore, it was difficult to judge what to do in such circumstance. In regarding to the laws, an environmental standard for air pollution in the underground space must unify into the standard of public hygiene.

  • PDF

Studies on the Environmental Behaviors of Ambient $PM_{2.5}$ and $PM_{10}$ in Suwon Area (수원지역 대기 중 $PM_{2.5}$$PM_{10}$의 환경거동에 관한 연구)

  • 김동술
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.2
    • /
    • pp.89-102
    • /
    • 2000
  • A total of 318 particulate sample sets consisting of both fine PM(FPM : dp$\leq$2.5 ${\mu}{\textrm}{m}$) and coarse PM(CPM : 2.5${\mu}{\textrm}{m}$${\mu}{\textrm}{m}$) was collected by a dichotomous sampler in Suwon area from December 1996 to November 1997. The concentration of seven inorganic elements such as pb. Cr, Cd, Cu, Zn Fe and Na were determined from each sample using an AAS. The purpose of the study was to extensively investigate environmental behaviors of particulate matters and to provide air quality management schemes applying various statistical approaches. The mean concentrations of PM10 Results of correlation analyses indicated the existence of strong correlations among inorganic elements PM10 FPM CPM and various meterological variables. Our study also examined the degree of uncertainties whether the particular elements can be assorted into the accumulation mode or the coarse mode in their size distribution. Furthermore the analysis of the pollution rose showed graphically the direction of potential sources of particulate matters. According to statistical analyses of our data quantitative differences appeared in the pollution patterns between weekdays and weekends.

  • PDF

Assessment of Reliability when Using Diagnostic Binary Ratios of Polycyclic Aromatic Hydrocarbons in Ambient Air PM10

  • Pongpiachan, Siwatt
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8605-8611
    • /
    • 2016
  • The reliability of using diagnostic binary ratios of particulate carcinogenic polycyclic aromatic hydrocarbons (PAHs) as chemical tracers for source characterisation was assessed by collecting PM10 samples from various air quality observatory sites in Thailand. The major objectives of this research were to evaluate the effects of day and night on the alterations of six different PAH diagnostic binary ratios: An/(An + Phe), Fluo/(Fluo + Pyr), B[a]A/(B[a]A + Chry), B[a]P/(B[a]P + B[e]P), Ind/(Ind + B[g,h,i]P), and B[k]F/Ind, and to investigate the impacts of site-specific conditions on the alterations of PAH diagnostic binary ratios by applying the concept of the coefficient of divergence (COD). No significant differences between day and night were found for any of the diagnostic binary ratios of PAHs, which indicates that the photodecomposition process is of minor importance in terms of PAH reduction. Interestingly, comparatively high values of COD for An/(An + Phe) in PM10 collected from sites with heavy traffic and in residential zones underline the influence of heterogeneous reactions triggered by oxidising gaseous species from vehicular exhausts. Therefore, special attention must be paid when interpreting the data of these diagnostic binary ratios, particularly for cases of low-molecular-weight PAHs.

Synthesis of thin-multiwalled carbon nanotubes by Fe-Mo/MgO catalyst using sol-gel method

  • Dubey, Prashant;Choi, Sang-Kyu;Kim, Bawl;Lee, Cheol-Jin
    • Carbon letters
    • /
    • v.13 no.2
    • /
    • pp.99-108
    • /
    • 2012
  • The sol-gel technique has been studied to fabricate a homogeneous Fe-Mo/MgO catalyst. Ambient effects (air, Ar, and $H_2$) on thermal decomposition of the citrate precursor have been systematically investigated to fabricate an Fe-Mo/MgO catalyst. Severe agglomeration of metal catalyst was observed under thermal decomposition of citrate precursor in air atmosphere. Ar/$H_2$ atmosphere effectively restricted agglomeration of bimetallic catalyst and formation of highly-dispersed Fe-Mo/MgO catalyst with high specific surface-area due to the formation of Fe-Mo nanoclusters within MgO support. High-quality thin-multiwalled carbon nanotubes (t-MWCNTs) with uniform diameters were achieved on a large scale by catalytic decomposition of methane over Fe-Mo/MgO catalyst prepared under Ar-atmosphere. The produced t-MWCNTs had outer diameters in the range of 4-8 nm (average diameter ~6.6 nm) and wall numbers in the range of 4-7 graphenes. The as-synthesized t-MWCNTs showed product yields over 450% relative to the utilized Fe-Mo/MgO catalyst, and indicated a purity of about 85%.

Synthesis of Nanoporous Metal Oxide Films Using Anodic Oxidation and Their Gas Sensing Properties

  • Suh, Jun Min;Kim, Do Hong;Jang, Ho Won
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.1
    • /
    • pp.13-20
    • /
    • 2018
  • Gas sensors based on metal oxide semiconductors are used in numerous applications including monitoring indoor air quality and detecting harmful substances like volatile organic compounds. Nanostructures, for example, nanoparticles, nanotubes, nanodomes, and nanofibers have been widely utilized to improve gas sensing properties of metal oxide semiconductors, and this increases the effective surface area, resulting in participation of more target gas molecules in the surface reaction. In the recent times, 1-dimensional (1D) metal oxide nanostructures fabricated using anodic oxidation have attracted great attention due to their high surface-to-volume ratio with large-area uniformity, reproducibility, and capability of synthesis under ambient air and pressure, leading to cost-effectiveness. Here, we provide a brief overview of 1D metal oxide nanostructures fabricated by anodic oxidation and their gas sensing properties. In addition, recent progress on thin film-based anodic oxidation for application in gas sensors is introduced.

An Experimental Study on Electrohydrodynamic Atomization of Non-Conducting Liquid (비전도성 액체의 전기수력학적 분무에 관한 실험적 연구)

  • Lee, Ki-Joon;Park, Jong-Seung;Lee, Sang-Yong
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1322-1327
    • /
    • 2004
  • In the present work, a series of experiments have been performed on electro-hydrodynamic atomization of non-conducting liquid using a charge injection type nozzle. Effects of liquid flow rate, input voltage, and distance between the needle and the ground electrode (nozzle-embedded metal plate) have been examined. For fixed electrode distances, total and spray currents increase with increase of liquid flow rate and input voltage. When the distance between the needle and the ground electrode becomes closer, total, leakage and spray current increase, but the onset voltage for dielectric breakdown decreases. When the electric field strength of the liquid jet exceeds that for the air breakdown, a portion of the electric charges in the liquid jet is dissipated into the ambient air, and the charge density shows a limiting value. Atomization quality can be improved by increasing the flow rate because the higher charge density is achieved with the larger liquid velocity in addition to the enhanced aerodynamic effect.

  • PDF