• 제목/요약/키워드: Ambient air ozone concentration

검색결과 41건 처리시간 0.029초

광도가 서울 대기의 오존 생성 및 에어로졸 수 농도에 미치는 영향 (Effect of light intensity on the ozone formation and the aerosol number concentration of ambient air in Seoul)

  • 배귀남;박주연;김민철;이승복;문길주;김용표
    • 한국입자에어로졸학회지
    • /
    • 제4권1호
    • /
    • pp.9-20
    • /
    • 2008
  • The effect of light intensity on the ozone formation and the aerosol number concentration during the photochemical reactions of ambient air was investigated in an indoor smog chamber. The smog chamber consists of a housing, 64 blacklights, and a $2.5-m^3$ reaction bag made of Teflon film. The bag was filled with the unfiltered ambient air in Seoul from January 10 to March 18, 2002. In this work, the photolysis rate of $NO_2$, $k_1$ was used as an index of light intensity. Three levels of light intensity were controlled by changing the number of blacklights turned on among 64 blacklights: $0.29min^{-1}$ (50%), $0.44min^{-1}$ (75%), $0.57min^{-1}$ (100%). The ozone concentration increased rapidly within 10 minutes after irradiation irrespective of light intensity, thereafter it increased linearly during the irradiation. The ozone production rate seems to be dependent on both the light intensity and the quality of ambient air introduced into the reaction bag. The change in aerosol number concentration also depended on both the light intensity and the ambient air quality, especially aerosol size distribution. Based on the initial ambient aerosol size distributions, the photochemical potential for aerosol formation and growth is classified into two cases. One is the case showing aerosol formation and growth processes, and the other is the case showing no apparent change in particle size distribution.

  • PDF

자연대기수준의 오존농도가 동진벼의 수량에 미치는 영향 (Effects of Ambient Ozone Levels on Rice Yield)

  • 허재선;이충일
    • 한국식물병리학회지
    • /
    • 제14권6호
    • /
    • pp.720-724
    • /
    • 1998
  • Open-top field chamber study was carried out to investigate effect of ambient ozone level on the yield of rice cultivar 'Dongjin' in Kwangyang area located in the vicinity of the industrial complex of Yechon petrolium refinery and chemical works or Kwangyang Iron and Steel works during the summer of 1997. mean ozone concentration of ambient air during daytime (9:00∼17:00) was revealed to exceed over 40 ppb which is defined to be a critical level causing plant injury and yield reduction in Europe. Yield component analysis showed that there was no significant difference in rice yield between ambient air and charcoal-filtered air. The results suggest that the ambient ozone levels during the exposure period had no effect on yield reduction of rice cultivar 'Dongjin' and it is likely that the cultivar is tolerant to ambient ozone levels.

  • PDF

서울시 대기중 오존의 오염도와 그 영향인자 분석 (An Analysis of Influencing Factors on Ozone Concentration in the Ambient Air in Seoul)

  • 정용;장재연;권숙표
    • 한국대기환경학회지
    • /
    • 제2권1호
    • /
    • pp.73-79
    • /
    • 1986
  • This study is carried out to determine the concentration of the ozone and the factors affecting the variation of ozone concentration in the ambient air in Seoul. The one-hour average concentration of ozone $(O_3)$, sulfur dioxide $(SO_2)$, nitrogen oxides (NO and $NO_2$), suspended particulate (TSP), carbon monoxide (CO) and non-methane hydrocarbon (NMHC) at 5 sites in Seoul measured from September to October in 1983 and 1984 were analysed statistically along with meteorological data for the same period. The results were as follows; 1. The average concentrations of ozone at 5 sites during the period ranged from 3.3 to 9.1 ppb, they were below 20 ppb of the ambient air quality standard of Korea. 2. The maximum hourly concentration of ozone occurred between 2 and 3 p.m. in a day and concentration at night were very low but higher concentrations were observed at around 4 a.m. 3. The concentration ratio between NO and $NO_2$ in Seoul was relatively lower than that for the cities of foreign countries reported so far. 4. The ozone concentration has negative correlationships with the concentration of other primary pollutants$(SO_2, NO, NO_2, CO and NMHC)$ in simple regression analyses. 5. The ozone concentration was positively correlated to wind speed, temperature and insolation intensity but negatively correlated to relative humidity. 6. Stepwise multiple regression analysis of the ozone concentration to the pollutants and meteorological factors indicate that insolation intensity and $[NO_2]/[NO]$ were the primary influencing factors. 7. The three factors of insolation intensity, $[NO_2]/[NO] and NO_2$ concentration had a significant combined effect on the ozone concentration $(r^2 = 0.47-0.57)$.

  • PDF

시화.반월단지지역의 고농도 오존일에 대한 광화학모델 적용 연구 - 기상특성에 대한 분석 - (A study on high ozone concentration in Shiwha.Banwol industry complex using photochemical air pollution model- Analysis of meteorological characteristics -)

  • 안재호
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.47-59
    • /
    • 2011
  • The purpose of this paper is to simulate the high ozone concentration in Shiwha Banwol indusrial complex. High pollution episodes (ozone alert) of this area are the results of geographical location and its air pollutants emission. This research has used meteorological model (RAMS) and photochemical air pollution Model (CIT model). As first step of the evaluate of this combined model system simulations are done in terms of meteorological characteristics like wind fields, PBL-height, etc.. Numerical simulations are carried out with real meteorological synoptic data on June. 24-25, 2010. In comparison with real measurement and another research the model reflects well local meteorological phenomena and shows the possibility to be utilized to analyse the pollutant dispersion over irregular terrain region. The high ozone concentration is deeply correlated to the ambient air temperature, wind speed and solar radiation. Local meteorological phenomena like sea-land breeze impact on horizontal dispersion of ozone. This analysis of meteorological characteristics can, in turn, help to predict their influences on air quality and to manage the high ozone episodes.

대구시 고농도 오존 사례일인 경우 대기 오염물질 농도의 일변화 특성 (Characteristics of Diurnal Variation of the Atmospheric Pollutants Concentration in High-Ozone Episode day in Daegu)

  • 손임영;윤일희;김희종
    • 한국환경과학회지
    • /
    • 제11권12호
    • /
    • pp.1253-1259
    • /
    • 2002
  • This study analyzes the surface ozone, NO and $NO_2$ concentration data from 1997 to 1999 in Daegu. It investigates effect on precursor during high-ozone episode days. The high-ozone episode is defined when a daily maximum ozone concentration is higher than 100 ppb(ambient air quality standard of Korea) in at least one station among six air quality monitoring stations. The frequency of episodes is 13 days(33 hours). The frequency is the highest in May and September, and the area with the highest frequency is Nowondong and Manchondong. The average value of daily maximum ozone concentration with high ozone episode is 81.6 ppb, and that of 8-hour average ozone concentration is 58.6 ppb. It means that ozone pollution is continuous and wide-ranging in Daegu. The daily variation of NO, $NO_2$ and $O_3$ in high-ozone episodes are inversely proportional one another. Nowondong an industrial area, is affected by pollutants that are emitted from the primary sources, while Manchondong a residential area, is affected by the advection of $O_3$ or by the primary pollutants like VOCs.

항공기를 이용한 남해안 지역의 오존 공간분포 조사 (2009년, 여름철) (The Analysis of Spatial Distribution of Ozone in the Southern Coast of Korea using the Aircraft (2009, Summer))

  • 서석준;김소영;이민도;최진수;김수연;이석조;김정수;이강웅
    • 한국대기환경학회지
    • /
    • 제28권1호
    • /
    • pp.12-21
    • /
    • 2012
  • The purpose of this study is to understand distribution of ozone concentration in the south coastal region of Korea by evaluating ozone spatial distribution in the upper air using aircraft. Sampling was carried out from May to August in 2009. The average concentration of ozone in the upper air was ranged from 32.3~90.8 ppb with its maximum concentration of 132 ppb. When it comes to the spatial distribution of ozone, ambient concentration was high in the air, 1,000 m and 500 m above the southern sea near the Gwangyang Bay area and emission sources, respectively. Daily mean concentration of NOy was 6.7~24.2 ppb and that of CO was 0.152~0.487 ppm. In addition, the concentration was appeared to be relatively high in the upper air of industrial regions and the southern seas. Meanwhile, the concentration of both $NO_y$ and CO was high in the upper air of the emission sources regardless of latitude. As for PAN, its daily mean concentration ranged between 0.1 and 0.6 ppb with overall mean concentration of 0.2 ppb. The average concentration of VOCs was 48 ppb, and the concentration of toluene and m,p-Xylene were higher than other components.

통계분석을 이용한 광주지역 대기오염도 (An Assessment of Air Quality Using Statistical Analysis in Gwangju Area)

  • 서광엽;백계진;신대윤
    • 한국환경보건학회지
    • /
    • 제30권5호
    • /
    • pp.417-426
    • /
    • 2004
  • We investigate changing characteristics and concentration distribution of ambient air quality using data from which obtained local ambient air monitoring network and local meterological measuring sites in Gwangju area from January to December in 2003. Sulfur dioxide ($SO_2$) showed that increase from 8 AM and decrease in 6 PM but, it was not drastically changed concentration. it also 0.010 ppm in 1995 from at this time it's decrease step by step and than some constant in year 2001 to 2003. Nitrogen dioxide ($NO_2$) concentration was showed highest peak in 10 AM and increase again at 6 PM. And also it showed peak concentration (0.026 ppm) in 2001 and decreased from after that times. Ozone was showed peak concentration in 1 PM and Nitrogen dioxide was ditto in 10 AM from this data, we can conclude that this two article ws showed chemical reaction by 3 to 5 hours. There was no case of Ozone alarm in Gwangju area since 1995, but it showed highest ozone concentration (over 0.070 ppm) in May and June of the year and 2 to 4 PM of the day and sometimes it showed increase at the dawn. Ozone product optimum condition was that air temperature is over $25^{\circ}C$, no rain and increase solar radiation (over $20MJ/m^2$) and no wind or below 2.0 m/s wind speed.

단기 측정용 오존 간이 측정기의 실험 챔버 내에서 성능에 관한 연구 (A Study on the Performance of a Short Term Ozone Passive Sampler in Experimental Chamber)

  • 정상진
    • 한국환경과학회지
    • /
    • 제16권8호
    • /
    • pp.1001-1009
    • /
    • 2007
  • Passive sampler is a simple and cost-effective measuring equipment for ambient and indoor air pollution. We studied the performance of a short term (1 hour mean concentration) ozone passive sampler which was coated with a colorant (indigo carmine) to a filter substrate. Acetone and sulfamic acid added ozone passive sampler was investigated to measure short term mean ozone concentration. Ozone response and interference of criteria air pollutant($SO_2,\;NO_2$, CO) on a short term ozone passive sampler was tested through experimental chamber. The results show sulfamic acid added passive ozone sampler have good response in ozone exposure. Interference of $NO_2$ gas is larger than other two criteria gases.

Spatial Analysis of Ambient Air Quality Using GIS

  • Choi, Byoung-Gil;Lee, Hee-Kwan;Ra, Young-Woo
    • Korean Journal of Geomatics
    • /
    • 제2권2호
    • /
    • pp.145-151
    • /
    • 2002
  • GIS technique is applied to the analysis of ambient air quality information. For this study, the TMS-monitored air quality information was imported with the geographical information of the TMS stations in Capital Area. It is found that currently available GIS technique has a great extend of potential for air quality management. From the analysis of air quality information, the GIS application demonstrates the poor air quality in the central Capital Area and the it is improved as it travels down to the suburb area. The ambient air quality is also proven to be highly influenced by the ozone concentration in a mid-summer day.

  • PDF