• Title/Summary/Keyword: Ambient Environment

Search Result 1,166, Processing Time 0.031 seconds

A Review on the Atmospheric Concentrations of Polycyclic Aromatic Hydrocarbons (PAHs) in Asia Since 2000 - Part I: Data from Developed Countries

  • Suvarapu, Lakshmi Narayana;Seo, Young-Kyo;Lee, Beom-Seok;Baek, Sung-Ok
    • Asian Journal of Atmospheric Environment
    • /
    • v.6 no.3
    • /
    • pp.147-168
    • /
    • 2012
  • Among all hazardous air pollutants, polycyclic aromatic hydrocarbons (PAHs) are more significant owing to their carcinogenic, mutagenic and teratogenic properties. Many researchers worldwide have focused on determining the concentrations of PAHs in ambient air. However, the literature survey reveals that the seriousness of air pollution in Asia in terms of PAHs, compared to the rest of the world. Owing to the importance of PAHs in Asia, this paper reviews the concentrations of PAHs in Asia in recent years. For convenience, this paper describes the concentrations of PAHs in developed Asian countries reported during 2000-2011 as Part-I and in developing Asian countries as Part-II. The first section of this review provides a brief description of the properties, sources of PAHs and the health effects caused by their presence in the atmosphere. The ambient air PAH concentrations in both particle and vapor phases in developed Asian countries are then discussed. This study finds the ambient air concentrations of PAHs in developed Asian countries was higher than the Western countries but was lower than the developing Asian countries. The present review predicts the accurate toxicity due to the presence of PAHs in the atmosphere by calculating the Risk Weighted Concentration (RWC), regardless of the total amount of PAHs. The total data obtained during the literature survey is tabulated and presented as supplementary information to the readers.

Initial and Near-field Dilution at the Ocean Outfall of Masan-Changwon Municipal Wastewater Treatment Plant(II) (마산ㆍ창원 하수종말 처리장의 해양방류 처리수에 대한 초기ㆍ근역 희석연구(II))

  • Kang See Whan;You Sung-Hyup;Oh Byung-Cheol;Park Kwang-Soon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.3 no.1
    • /
    • pp.35-44
    • /
    • 2000
  • The winter case of the near-field dilution at the Masan outfalls has been studied by field measurements and CORMIX model simulations. Dilution rates of the wastewater discharge in winter were obtained by a salinity deficit method using the field data observed in the neap tidal period of February, 1999. The observed dilution rates in winter season were found to be very high in the range of 90~130 due to the isopycnal mixing of ambient density compared with the summer range of 30~40 under weak neap tidal currents. The results of CORMIX model simulations also show that the winter dilution rates under a weak ambient current(Ua=6.0ms/s) were increased by 3-fold of the summer dilution rates. However, the difference between two seasons becomes small by 30% under a strong current(Ua=15.5cm/s). This result indicates that the dilution and hydrodynamic mixing process of the effluents are more influenced by ambient crossflow condition than by ambient density stratification at the outfalls site.

  • PDF

An Experimental Study of the Effect of the Test-well Arrangement on the Partitioning Interwell Tracer Test for the Estimation of the NAPL Saturation (지하수 유동 방향에 대한 관정배열이 분배추적자 시험에 미치는 영향 분석)

  • Kim, Bo-A;Kim, Yongcheol;Yeo, In Wook;Ko, Kyung-Seok
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.111-122
    • /
    • 2014
  • Partitioning interwell tracer test (PITT) is a method to quantify and qualify a site contaminated with NAPLs (Non-Aqueous Phase Liquids). Analytical description of PITT assumes that the injection-pumping well pair is on the line of the ambient groundwater flow direction, but the test-well pair could frequently be off the line in a real field site, which could be an erroneous factor in analyzing PITT data. The purpose of this work is to study the influence of the angle of the test-well pair on the ambient groundwater flow direction based on the result from PITT. From the experiments, it was found that the obliqueness of the test-well pair to the ambient groundwater flow direction could affect the tracer test resulting in a decreased NAPL estimation efficiency. In case of an oblique arrangement of the test-well pair to the ambient flow direction, it was found that the injection of a chase fluid could enhance the estimation efficiency. An increase of the pumping rate could enhance the recovery rate but it cannot be said that a high pumping rate can increase the test efficiency because a high pumping rate cannot give partitioning tracers enough time to partition into NAPLs. The results have a implication that because the arrangement of the test-well pair is a controlling factor in performing and interpreting PITT in the field in addition to the known factors such as heterogeneity and the source zone architecture, flow direction should be seriously considered in arranging test-well pair.

The Current Distribution and Habitat Preferences of Hibernating Myotis formosus in Korea

  • Kim, Sun-Sook;Choi, Yu-Seong;Kim, Bong-Hyeon;Yoo, Jeong-Chil
    • Journal of Ecology and Environment
    • /
    • v.32 no.3
    • /
    • pp.191-195
    • /
    • 2009
  • We monitored 38 hibernation sites of Myotis formosus in South Korea and recorded the number of bats occupying each site and assessed the micro-climate at the sites during four winters from 2005 to 2009 at. The mean rock temperature of the bat roosting sites was $13.2{\pm}1.4^{\circ}C$ and the mean body temperature of the hibernating bats was $13.3{\pm}1.3^{\circ}C$. The number of hibernating bats was negatively related to the size of the entrance and positively related to the minimum ambient temperature and humidity in the site interior. More bats hibernated in roosts with smaller entrances and higher minimum ambient temperatures, and more bats selected sites presenting a narrow temperature range. This study showed that the internal environments of hibernacula of M. formosus were highly stable despite dramatic variation in the external environment.

Comparison of Sampling and Analysis Methods for Volatile Organic Compounds in Ambient Air (대기중 휘발성 유기화합물의 채취 및 분석 방법 비교)

  • 나광삼;김용표
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.5
    • /
    • pp.507-518
    • /
    • 1998
  • A field comparison study was carried out to quantify differences among various sampling and analytical methods for volatile organic compounds (VOCs) at a site in Vlsan in June 1997. Air sampling containers (SUMMA canisters) were used by the Korea Institute of Science and Technology (KIST) and adsorption tubes (carbotrap) were used by Yeungnam University (YN Univ.) for sampling ambient air. Duplicate samples obtained by KIST were analyzed by KIST with a GC-MS system for aromatics and halogenated hydrocarbons and by Atm AA with a GC -FID system for C2∼C9 hydrocarbons, respectively. The adsorption tube samples were analyzed by YN Univ. with a GC-FID system for aromatics. VOC levels for the duplicate canister sampls analyzed by KIST and Atm AA were in good agreement. Concentrations of aromatics by the adsroption tube method were generally higher than those by the canister sampling method by factor of 1.5 to 2.0. Differences between the two sampling methods were discussed.

  • PDF

Concentration of Particulate Nitrate Originated from Sea Salt in Seoul Ambient Air (서울시 부유분진중 해염입자에 의한 입자상 nitrate농도)

  • 천만영;이영재;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.3
    • /
    • pp.191-196
    • /
    • 1994
  • Concentration of particulate nitrate originated from sea salt in ambient air was determined from February to October 1993. Sampling was carried out using a two-stage Anderson air sampler at the top of a five-story building located at Kon-Kuk University in Seoul. Concentration of NaNO$_3$, which originated from sea salt was highest in spring time and lowest in summer the and the concentration range was between 0.10 and 0.66 $\mu\textrm{g}$/㎥. NaNO$_3$/TSP ratio was very low 0.05~0.39%) indicating that the portion of NaNO$_3$ in TSP was negligible.

  • PDF

Development of Relationship between Air Quality and Rain Acidity (대기질 - 강우산성도 관계식의 개발)

  • 구자공;유동준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.2 no.3
    • /
    • pp.45-51
    • /
    • 1986
  • The simple and precise model for the estimation of rain acidity from the ambient air quality was developed using the theory of wet scrubber and the chemical equilibria of $SO_2, CO_2, and H_2O$ system. From the measured mixing height, and from the developed relationship between NTU (=number of transfer units) and the concentration of $SO_2$(aq) in rain drops, the HTU (= height equivalent to one transfer unit, i.e. mass transfer resistance) was estimated, and validated with the field-measured data. In Seoul, Korea where the effect of $SO_2$ on rainfall acidity is as high as 84% and the average mixing height is 1 km, the average HTU of $SO_2$ system was found to be 191.5m. The important parameters affecting HTU were identified as rainfall intensity and initial ambient concentration of $SO_2$, and their effects on the value of overall volumetric mass transfer coefficient were quantified.

  • PDF

시추공 유속측정기(Borehole Flowmeter)를 이용한 암반의 구간별 수리전도도 산정

  • 구민호;차장환;이주형;박창희;정복선
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.93-97
    • /
    • 2001
  • 시추공의 구간별 수리전도를 추정하는 방법으로는 수압시험(packer test)이 많이 이용되는데 최근에는 유속측정기(flowmeter)를 이용한 시추공 검층법이 개발되어 활발한 연구가 진행 중이다. 본 연구에서는 열원(heat-pulse) 공급 방식의 유속측정기를 이용하여 공주대학 교내에 설치된 시추공에서 자연 유속(ambient flow) 및 양수 유발 유속(pump-induced flow)을 측정하였으며, 자료를 분석하여 수리전도도의 수직적인 분포를 산정하였다. 분석 결과는 수압시험에 의해 산정된 수리전도도의 분포와 잘 일치하였으며, BIPS에 의해 촬영된 시추공 영상 자료와 비교함으로써 지하수 유동과 관련된 투수성 단열(conductive fracture) 들의 수직적인 위치를 정확하게 파악할 수 있었다. 분석 결과는 암반 대수층 내에 발달된 단열망(fracture network)에 대한 3차원적인 정보를 제공할 수 있으며, 이는 효과적인 지하수 모니터링, 모델링, 및 정화 설계(remedial design)에 필요한 기초 자료로 활용될 수 있을 것으로 기대된다.

  • PDF

Visibility study in Seoul in Aug., 1993. (1993년 8월의 서울지역 시정 연구)

  • 이종훈;백남준;김용표;문길주
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.3
    • /
    • pp.291-298
    • /
    • 1995
  • An intensive field study was carried out during Aug. 1993 in Seoul to study the characteristics of summertime visibility and diurnal trend of ionic composition of ambient particles. A transmissometer, nephelometer with heated and unheated inlets, PM3 fine particle sampler, and cascade impactor were used to measure optical and particle properties of ambient air. During this study period, a weak smog episode has occurred. Light scattering by particles is the most dominant factor on total light extinction. The effect of light absorption by particles in Seoul is much higher than other major cities in U.S.A. throughout the summer and fall with relatively constant values. The effect of water on $b_{sp}$ was small during the period. The particle size distribution shows a typical bimodal one. Sulfate, ammonium, chloride, and nitrate are the major chemical species in fine fraction aerosols, about 30% of toral mass concentration. Concentraion of sulfate is higher during the daytime while those of nitrate and chloride are higher during the nighttime. Ammonium concentration is constant through the daytime.

  • PDF

A Study on the Heat pump - Latent Heat Storage System for the Greenhouse Heating (그린하우스 난방을 위한 열펌프-잠열축열 시스템 연구)

  • 송현갑;노정근;박종길;강연구;김현철
    • Journal of Biosystems Engineering
    • /
    • v.23 no.2
    • /
    • pp.147-156
    • /
    • 1998
  • It is desirable to use the renewable energy for the greenhouse heating in winter season, it make possible not only to save fossil fuel and conserve green environment but also to promote the quality of agricultural products and reduce the agricultural production cost. In this study the heat pump - PCM latent heat storage system has been developed to use the natural energy as much as possible for the thermal environment control of greenhouse. The coefficient of performance (COP) of the heat pump system was 3~4 with the ambient temperature ranging from 8$^{\circ}C$ to -8$^{\circ}C$, and greenhouse heating effect of the heat pump-PCM latent heat storage system on the basis of the ambient temperature was about 12-15$^{\circ}C$.

  • PDF