• Title/Summary/Keyword: Ambient Control

Search Result 606, Processing Time 0.023 seconds

Review of design parameters for FRP-RC members detailed according to ACI 440.1R-06

  • Jnaid, Fares;Aboutaha, Riyad
    • Computers and Concrete
    • /
    • v.11 no.2
    • /
    • pp.105-121
    • /
    • 2013
  • This paper investigates the parameters that control the design of Fiber Reinforced Polymer (FRP) reinforced concrete flexural members proportioned following the ACI 440.1R-06. It investigates the critical parameters that control the flexural design, such as the deflection limits, crack limits, flexural capacity, concrete compressive strength, beam span and cross section, and bar diameter, at various Mean-Ambient Temperatures (MAT). The results of this research suggest that the deflection and cracking requirements are the two most controlling limits for FRP reinforced concrete flexural members.

Temperature Control for an Oil Cooler System Using PID Control with Fuzzy Logic (퍼지 적용 PID제어를 이용한 오일쿨러 시스템의 온도제어)

  • 김순철;홍대선;정원지
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.4
    • /
    • pp.87-94
    • /
    • 2004
  • Recently, technical trend in machine tools is focused on enhancing of speed, accuracy and reliability. The high speed usually results in thermal displacement and structural deformation. To minimize the thermal effect, precision machine tools adopt a high precision cooling system. This study proposes a temperature control for an oil cooler system using Pill control with fuzzy logic. In the cooler system, refrigerant flow rate is controlled by rotational speed of a compressor, and outlet oil temperature is selected as the control variable. The fuzzy control rules iteratively correct PID parameters to minimize the error and difference between the outlet temperature and the reference temperature. Here, ambient temperature is used as the reference one. To show the effectiveness of the proposed method, a series of experiments are conducted for an oil cooler system of machine tools, and the results are compared with the ones of a conventional Pill control. The experimental results show that the proposed method has advantages of faster response and smaller overshoot.

The effect of dietary ions difference on drinking and eating patterns in dairy goats under high ambient temperature

  • Nguyen, Thiet;Chanpongsang, Somchai;Chaiyabutr, Narongsak;Thammacharoen, Sumpun
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.4
    • /
    • pp.599-606
    • /
    • 2019
  • Objective: The present study was carried out to evaluate the effect of high dietary cation and anion difference (DCAD) rations on diurnal variations in eating and meal patterns, water intake and urination patterns in dairy goats fed under high ambient temperature (HTa). Methods: Ten crossbred dairy goats during peri-parturition period were selected and divided into two groups of five animals each. Experimental diets were control DCAD (control, 22.8 mEq/100 g dry matter [DM]) and high DCAD (DCAD, 39.1 mEq/100 g DM). The composition of two diets consisted of 44% corn silage and 56% concentrate. From the 2nd week to 8th week postpartum, goats were fed ad libitum twice daily either with the control or DCAD total mix ration with free access to water. The spontaneous eating and drinking patterns were determined. Results: The environmental conditions in the present experiment indicated that goats were fed under HTa conditions (average peak THI = 85.2) and were in heat stress. In addition to the typical HTa induced tachypnoea in both groups, the respiratory rate in the DCAD group was significantly higher than the control group (p<0.05). Although the goats from both groups showed comparable level of eating, drinking and urination during experiment, the meal pattern and water intake were different. High DCAD apparently increased eating and meal patterns compared with the control. At week 8 postpartum, goats from high DCAD group had significant (p<0.05) bigger meal size and longer meal duration. Moreover, high DCAD appeared to increase night-time water intake (p<0.05). Conclusion: Both meal pattern and night-time drinking effects of DCAD suggested that feeding with high DCAD ration may alleviate the effect of heat stress in dairy goat fed under HTa conditions.

Implementation of a LED light control module using Zigbee (Zigbee를 이용한 LED 조명 제어 모듈 구성)

  • Jang, Young-Ho;Kim, Hwan-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.10
    • /
    • pp.4740-4744
    • /
    • 2012
  • The purpose of this paper was to make a LED light control module using Zigbee. The module was made so that brightness of the LED light changes according to the ambient brightness. A 8-bit microcontroller was used to implement the module to enable LED dimming and wireless light intensity measurement. Using the proposed method, power consumption can be improved by up to 48% on average, with 3.4-0.4W changes in power. The measured ambient light intensity values are converted from analog to digital and outputted as a PWM waveform. According to the output waveform and changes in the current outputted from the LED driver, the brightness of the LED light is controlled. Also, Zigbee with close-range wireless communication capabilities was used to enable wireless transmission of light intensity measurements.

Quality Control(QC) Analysis of Ambient VOCs in Canisters Using GC/MSD Method (Canister와 GC/MSD를 이용한 대기 중 VOCs 분석시스템의 정도관리(QC))

  • Jeon, Jun-Min;Hur, Dang;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.527-538
    • /
    • 2002
  • In this study, the performance of sampling and of analytical methodology was examined against a number of selected volatile organic compounds (VOCs) in the ambient air. The canister-based sampling method for VOCs has been a viable and widely used approach that is based on research and evaluation performed over the past several years. VOCs were determined using canisters by GCMSD analysis. A total of target analyses in this study included approximately 30 VOCs designated in TO-l4A categories including BTEX. The methodology for QC(quality control) was intensively investigated with a wide range of performance criteria such as; (1) cleanliness of canisters, (2) reproducibility of diluter, (3) instrumental detection limits of preconcentrator and GCMSD, and (4) precision and accuracy of GCMSD. For most of the compounds tested, precision was less than $\pm$5%, IDL was 0.2 ppbv, accuracy was $\pm$5%, respectively. This study demonstrated that the combination of canister sampling and GC/MSD analysis could be reliably applied to the measurements of BTEX in ppbv levels that are typically observed in/outdoor air environment.

A Development of a LED Stand Using Illuminance Sensor for Efficient Energy Saving (효율적인 에너지 절감을 위한 센서 LED 스탠드 개발)

  • Chun, Sung-Yong;Shin, Ji-Yea;Park, Shin-Won;Yi, Hwa-Cho;Lee, Chan-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.9
    • /
    • pp.1-7
    • /
    • 2012
  • In this paper, we present a new lighting control method considering ambient light in addition to the required lighting illumination for efficient energy saving of a LED stand. We estimate accurate environmental illuminance using a cheap illuminance sensor by modeling measured- and actual-illuminance using quadratic polynomial approximation. The relation between PWM(Pulse Width Modulation) duty ratio and illuminance intensity is modeled by a linear model. Illumination of the LED stand is controlled by estimating the difference of required illumination and the estimated ambient illumination. The developed LED stand has reduced electric energy consumption compared with a conventional manually controlled LED stand with the same lighting source. In addition, human subject evaluation shows that the LED stand, which is applied the proposed method, is more satisfactory than conventional ones since the proposed automatic controlled illumination produce more accurately required lighting and it is convenient.

The Effect of Indoor Temperature Change on Human Physiology for Comfort Control during Sleep Early Stage (쾌적제어를 위한 수면 초기 실내온도 변동이 인체 생리에 미치는 영향)

  • Shin, H.J.;Kim, D.G.;Jeong, S.K.;Kum, J.S.;Kim, H.C.
    • Journal of Power System Engineering
    • /
    • v.11 no.3
    • /
    • pp.29-34
    • /
    • 2007
  • Existent researches about indoor thermal environment have been focused on to seek human's comfort in daytime. Also researches about thermal comfort during the sleeping time that is important for resting and recharging to modern people have been seldom existed. At present, as global warming phenomenon is being continued, most people are going through inconvenience by sultriness during the sleeping hours in sweltering summer night. Therefore we need another control method of an air conditioner to keep human's thermal comfort. Ambient temperature is a common factor of the environment, but analysis of its effect on human body physiology is still unknown. The effect of ambient temperature on human sleep has been increasingly studied in the last decade. This research investigated about optimal indoor temperature to maintain proper skin temperature and comfortable sleep when indoor air is cooled by an air conditioner in sweltering summer night.

  • PDF

Subcellular Distribution of Heavy Metals in Organs of Bivalve Modiolus Modiolus Living Along a Metal Contamination Gradient

  • Podgurskaya, Olga V.;Kavun, Victor Ya.
    • Ocean Science Journal
    • /
    • v.41 no.1
    • /
    • pp.43-51
    • /
    • 2006
  • Concentration and distribution of Fe, Zn, Cu, Cd, Mn, Pb, Ni among subcellular fractions (cellular membrane structures and cytosol) and Zn, Cu, Cd among cytoplasmic proteins in the kidney and digestive gland of mussel Modiolus modiolus living along a polymetallic concentration gradient were studied. It was found in the kidney of M. modiolus from contaminated sites that the Fe percent increased in the "membrane" fraction, whereas Zn, Pb, Ni and Mn percent increased in the cytosol compared to the kidney of the control mussel. Note kidney cytosol of M. modiolus from clean and contaminated sites sequestered major parts of Cu and Cd. In the digestive gland of M. modiolus from contaminated sites Fe, Zn, Cd, Mn, Ni percent increased in the "membrane" fraction, whereas Cu, Pb percent increased in the cytosol compared to digestive gland of control mussel. Gel-filtration chromatography shows kidney of M. modiolus contains increased metallothionein-like protein levels irrespective of ambient dissolved metal concentrations. It was shown that the metal detoxification system in the kidney and digestive gland of M. modiolus was efficient under extremely high ambient metal levels. However, under complex environmental contamination in the kidney of M. modiolus, the metal detoxification capacity of metallothionein-like proteins was damaged.

The Effect of Chelators and Reductants on the Mobilization of Metals from Ambient Particulate Matter: More Transition Metals are Mobilized with PM2.5 than with PM10

  • Song, H-S;Chang, W-C;Bang, W-G;Kim, Y-S;Chung, N
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2002.10a
    • /
    • pp.155-155
    • /
    • 2002
  • Ambient urban particulate matters contain various transition metals. When the particulate matters are inhaled into the lung, not all but some part of metals from the particles might be mobilized to participate in a reaction that can damage various biomolecules, such as DNA and proteins. The dust particle size as well as organic acids may influence the metal mobilization. Thus, the mobilization of the metal from SRM1648 (NIST, USA) and urban particulate matters (PM2.5 and PM10) was measured in the presence of artificial or biological chelator with or without reductant. The degree of the mobilization was higher with the artificial or biological chelator than the control with saline. In some cases, a reductant increased the mobilization as much as about 5 times the control without the reductant. Especially, the mobilization of Fe was greatly influenced by the presence of reductants. In general, the degree of the mobilization of the transition metal was higher with PM2.5 than with PM10. Therefore, it is expected that, considering the previously known toxicities of the transition metals, the PM2.5 is more damaging to various biomolecules than PM10. The results also suggest that not the total amount but the mobilizable fraction of the metal in the dust particles should be considered with regard to the toxicity of the urban particulate matters.

  • PDF

Steady-state Thrust Characteristics of Hydrazine Thruster for Attitude Control of Space Launch Vehicles (우주발사체 자세제어용 하이드라진 추력기의 정상상태 추력 특성)

  • Kim, Jong Hyun;Jung, Hun;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.6
    • /
    • pp.48-55
    • /
    • 2012
  • An ambient hot-firing test was carried out for the hydrazine thruster which may be employed in the space launch vehicles. The thruster is designed to produce 67 N (15 $lb_f$) of nominal steady-state thrust at an inlet pressure of 2.41 MPa (350 psia). A scrutiny into the performance characteristics of thruster is made in terms of thrust, propellant supply pressure, mass flow rate, chamber pressure, and temperature at the steady-state firing mode. As a result, it is ensured that the practical performance efficiencies are above 89.1% compared to its ideal requirements.