• Title/Summary/Keyword: Ambient Control

Search Result 606, Processing Time 0.026 seconds

A Study on Performance Degradation Analysis of Gas Turbine Combined Heat and Power Plant (가스터빈 열병합발전소 성능저하 분석에 관한 연구)

  • Kim, Hong Joo;Kim, Byeong Heon;Oh, Byeong Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.248-255
    • /
    • 2016
  • In this study, the degree of performance changes between the guaranteed performance and the performance after a certain operating start time is calculated by using the performance test of gas turbine CHP. The reason of the performance degradation will then be analysed. For some results of the CHP plant performance tests the comprehensive electric power output was 8,380 kW lower than the guaranteed performance, and the gas turbine's output was reduced to about 250 kW whenever ambient temperatures rose to $1^{\circ}C$. Also, causes of the performance degradation of gas turbines are ambient temperature rise, temperature aging and air compressor's efficiency drop.

Drop Time Evaluation for SMART Control Rod Assembly (스마트 제어봉집합체의 낙하시간 평가)

  • Kim, Kyoung-Rean;Jang, Ki-Jong;Park, Jin-Seok;Lee, Won-Jae
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.2
    • /
    • pp.25-28
    • /
    • 2011
  • The control rod assemblies do freely fall into the reactor core by the gravity from the control rod drive mechanism. In order to achieve a rapid shutdown and control the reactor power, it is required to insert control rod assemblies as soon as possible. In this paper, we evaluated the drop time and flow characteristics caused around guide tube for SMART(System-integrated modular advanced reactor) control rod assembly. Numerical analyses are carried out with FLUENT program of computational fluid dynamics. This study results show that the drop time of the control rod assembly in the operating condition of SMART is more 20 percent rapidly than the drop time of the room temperature and ambient atmosphere condition.

Trends and Control Technologies of Volatile Organic Compound (국내의 휘발성유기화합물(VOC) 현황 및 관리기술)

  • Kim, Jo-Chun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.743-757
    • /
    • 2006
  • Volatile organic compound (VOC) has been well-known to Korea since the end of 1990's however, it has not been well documented until now. In this study, present ambient VOC levels, VOC emission sources, and VOC control technologies were reviewed and discussed. In addition, VOC management strategies to cut down ozone concentrations were suggested based on the present VOC database. For anthropogenic VOC reduction, VOC emitted from painting processes and automobiles should be controlled in the first place in large cities such as Seoul, Daegu, and Incheon. For natural VOC management, low emission trees need to be planted in those cities. It is also very significant to keep updating present and future VOC emission inventories for efficient VOC control strategies. As a conclusion, more systematic VOC control road-map based on BACT (best available control technology) needs to be made up. and more economical and efficient VOC control techniques have to be developed under strong national support in order to lower toxic VOC and photochemical oxidant levels.

Performance evaluation of a 400 W precise window motor for glass houses

  • Hong, Soon-Joong;Park, Soo-Bok;Kang, Na-Rae;Kim, Yong-Joo;Chung, Sun-Ok
    • Korean Journal of Agricultural Science
    • /
    • v.44 no.4
    • /
    • pp.595-603
    • /
    • 2017
  • Crop growth and production cost are greatly influenced by management of environmental factors such as ambient temperature, humidity, and $CO_2$, especially in protected horticulture. Opening and closing of greenhouses is the most important operation for control of these ambient environmental factors, and precise and stable operation requires high performance window motors. In this study, a 400 W precise window motor was constructed, and its performance was evaluated for plastic and glass greenhouses. First, the motor was designed and fabricated by benchmarking of an advanced foreign product. Then, the performance was evaluated through vibration, PCB (Process Control Block), and load tests. Vibration tests resulted in averaged vibration displacement and velocity of the developed motor of 0.002 mm and 0.2267m/s, which were statistically significantly different from those of the target motor. Average vibration acceleration ($0.26m/s^2$) of the developed motor was also significantly different from that ($0.51m/s^2$) of the target motor. PCB tests showed 2 - 4 mm deviation from the target values, and confirmed the operating status and precision of the control. Load tests with a 300 kg load also showed acceptable operating status and durability. Current values were $1.31{\pm}0.06A$ and RPMs were in the range of 2.9 - 3.0. Considering the above results, the developed window motor would be competitive to the target foreign product.

Identifications of Source Locations for Atmospheric Total Gaseous Mercury Using Hybrid Receptor Models (Hybrid receptor model을 이용한 대기 중 총 가스상 수은의 오염원 위치 추정 연구)

  • Lee, Yong-Mi;Yi, Seung-Muk;Heo, Jong-Bae;Hong, Ji-Hyoung;Lee, Suk-Jo;Yoo, Chul
    • Journal of Environmental Science International
    • /
    • v.19 no.8
    • /
    • pp.971-981
    • /
    • 2010
  • The objectives of this study were to measure ambient total gaseous mercury (TGM) concentrations in Seoul, to analyze the characteristics of TGM concentration, and to identify of possible source areas for TGM using back-trajectory based hybrid receptor models like PSCF (Potential Source Contribution Function) and RTWC (Residence Time Weighted Concentration). Ambient TGM concentrations were measured at the roof of Graduate School of Public Health building in Seoul for a period of January to October 2004. Average TGM concentration was $3.43{\pm}1.17\;ng/m^3$. TGM had no notable pattern according to season and meteorological phenomena such as rainfall, Asian dust, relative humidity and so on. Hybrid receptor models incorporating backward trajectories including potential source contribution function (PSCF) and residence time weighted concentration (RTWC) were performed to identify source areas of TGM. Before hybrid receptor models were applied for TGM, we analysed sensitivities of starting height for HYSPLIT model and critical value for PSCF. According to result of sensitivity analysis, trajectories were calculated an arrival height of 1000 m was used at the receptor location and PSCF was applied using average concentration as criterion value for TGM. Using PSCF and RTWC, central and eastern Chinese industrial areas and the west coast of Korea were determined as important source areas. Statistical analysis between TGM and GEIA grided emission bolsters the evidence that these models could be effective tools to identify possible source area and source contribution.

Investigation on the Validation for Designating Air Quality Control Region among Provincial Cities by the Data Measured with Air Quality Monitoring Network (대기오염 측정 자료에 의한 지방도시의 대기환경규제지역 설정에 관한 타당성 검토)

  • Yu, Mee-Seon;Yang, Sung-Bong;Woo, Kyung-Bin
    • Journal of Environmental Science International
    • /
    • v.25 no.1
    • /
    • pp.181-190
    • /
    • 2016
  • Regional air quality regulation is a system that allows the Minister of Environment to designate the local area as air quality control region where the concentrations of air pollutants are exceeding the environmental standards, and the local governments that administrate the regulated area have to develop and practise a plan for reducing the air pollutants. From the data observed yearly by the monitoring stations in 8 provincial cities with more than 0.5 million people was judged the compliance with air quality standards in each municipality for the period of 2003 to 2013. As the result of investigation on air pollutants concentrations of each city, it was found that there was no station that exceeds the ambient air quality standards of CO, $SO_2$ and 24-hour $NO_2$. But all municipalities exceeded the standards of 8-hour $O_3$, annual and 24-hour $PM_{10}$, and therefore 8 municipalities can be designated to be under the local air regulation. For the annual $NO_2$ were the monitoring sites necessary requirements for designation of the air quality regulation region in Cheongju, Cheonan, Daejeon and Gwangju area. Incase of 1-hour $O_3$, some of stations in Pohang, Cheongju, Cheonan and Changwon area were over the designation standards for the air quality control region.

Multi-dimensional seismic response control of offshore platform structures with viscoelastic dampers (I-Theoretical analysis)

  • He, Xiao-Yu;Li, Hong-Nan;Zhang, Jun
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.2
    • /
    • pp.157-174
    • /
    • 2016
  • Based on classical viscoelastic damper, a brand-new damper is designed by the change of simple construction to implement vibration control for both translational vibration and rotational vibration simultaneously. Theoretic analysis has been carried out on the restoring force model and the control parameters. Two improved models are presented to obtain high simulation precision. The influence of the size, shape of the viscoelastic material, the ambient temperature and the response frequency on the vibration control effect is analyzed. The numerical results show that the new type viscoelastic damper is capable of mitigating the multi-dimensional seismic response of offshore platform and the response control effect has complicated relations with aforementioned related factors.

Changes in Moisture Content and Quality of Oriental Hybrid Lily (Lilium oriental cv. Siberia) Cut Flowers during Storage at Cold and Dry Condition and Subsequent Exposure to Ambient Temperature (오리엔탈 나리 '시베리아' 절화의 포장내 건식저장 기간별 수분함량과 품질 변화)

  • Lee, Jung-Soo;Rhee, JuHee;Kang, Yun-Im;Choi, Ji Weon
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.23 no.1
    • /
    • pp.27-36
    • /
    • 2017
  • In order to determine the relationship between water content and flower qualities of oriental hybrid lily cv. 'Siberia' cut flower, flowers were subjected to dry and cold storage at $5^{\circ}C$ for 3, 6, and 12 days and subsequently exposed to ambient temperature ($26^{\circ}C$) in bottles with water for up to 16 days. Flowers stored at $22^{\circ}C$ in dry condition for 3 days were used as the control. Changes in fresh weight, moisture content, water balance, flowering stages, osmolality and vase life of cut flowers were observed. Flowers treated with cold and dry storage had higher moisture content compared to control sample. However, this trend was evident only for 3-day cold and dry stored sample during the whole storage period. The fresh weight of cut flowers increased gradually when the samples were transferred to ambient temperature in water bottles and then declined steadily before reaching the peak in between 6-8 days of vase life. However, the changes of fresh weight of control sample were substantially faster than samples pre-treated with cold and dry storage. This was also correlated with the water balance of cut flower as it reached the minus (-) value in 6-8 days of vase life at ambient temperature. Cut lily flowers showed high osmolality values corresponding with the duration of dry storage regardless of low or higher temperature. However, osmolality had no effect on vase life since flower stem absorbed water rapidly at the end of dry storage period. Our vase life results suggest that cold and dry storage of lily cut flowers for a certain period could ensure longer vase life at ambient temperature. It was observed that prolonging the storage period at cold and dry condition for more than a week significantly increased bud abortion, reduced longevity of flowers and reduced the vase life of cut flowers. On the other hand, the shorter cold and dry storage treatment delayed the bud opening and senescence of the flowers, thus, slowering the normal maturation and aging. Results indicated that dry and cold storage at $5^{\circ}C$ for 3 days was effective in maintaining and preserving overall quality and vase life at ambient condition of oriental hybrid lily cut flowers.

Structural performance evaluation of a steel-plate girder bridge using ambient acceleration measurements

  • Yi, Jin-Hak;Cho, Soojin;Koo, Ki-Young;Yun, Chung-Bang;Kim, Jeong-Tae;Lee, Chang-Geun;Lee, Won-Tae
    • Smart Structures and Systems
    • /
    • v.3 no.3
    • /
    • pp.281-298
    • /
    • 2007
  • The load carrying capacity of a bridge needs to be properly assessed to operate the bridge safely and maintain it efficiently. For the evaluation of load carrying capacity considering the current state of a bridge, static and quasi-static loading tests with weight-controlled heavy trucks have been conventionally utilized. In these tests, the deflection (or strain) of the structural members loaded by the controlled vehicles are measured and analyzed. Using the measured data, deflection (or strain) correction factor and impact correction factor are calculated. These correction factors are used in the enhancement of the load carrying capacity of a bridge, reflecting the real state of a bridge. However, full or partial control of the traffic during the tests and difficulties during the installment of displacement transducers or strain gauges may cause not only inconvenience to the traffic but also the increase of the logistics cost and time. To overcome these difficulties, an alternative method is proposed using an excited response part of full measured ambient acceleration data by ordinary traffic on a bridge without traffic control. Based on the modal properties extracted from the ambient vibration data, the initial finite element (FE) model of a bridge can be updated to represent the current real state of a bridge. Using the updated FE model, the deflection of a bridge akin to the real value can be easily obtained without measuring the real deflection. Impact factors are obtained from pseudo-deflection, which is obtained by double-integration of the acceleration data with removal of the linear components on the acceleration data. For validation, a series of tests were carried out on a steel plategirder bridge of an expressway in Korea in four different seasons, and the evaluated load carrying capacities of the bridge by the proposed method are compared with the result obtained by the conventional load test method.

Impact of Elevated Temperature in Growing Season on Growth and Bulb Development of Extremely Early-Maturing Onion (Allium cepa L. cv. Singsingball) (생육기 온도상승이 극조생 양파의 생육 및 구 비대에 미치는 영향)

  • Song, Eun Young;Moon, Kyung Hwan;Wi, Seung Hwan;Kim, Chun Hwan;Lim, Chan Kyu;Oh, Soonja;Son, In Chang
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.19 no.4
    • /
    • pp.223-231
    • /
    • 2017
  • This study was conducted to determine the impact of elevated temperature based on climate change scenario on growth and bulb quality of extremely early-maturing onion (Allium cepa L. cv. Singsingball) in the temperature gradient tunnels. There were treated with 3 groups, one is a control group (ambient temperature, mean temperature at $9.8^{\circ}C$), another ambient temperature $+2^{\circ}C$ (mean temperature at $12.0^{\circ}C$), and the other ambient temperature $+5^{\circ}C$ (mean temperature at $14.3^{\circ}C$). Compared with the control, plant height, neck diameter, leaf area, top fresh weight and dry weight were significantly increased at ambient $+2^{\circ}C$ temperature. Bulb diameter and bulb weight was highest at ambient $+2^{\circ}C$ temperature (mean temperature at $12.0^{\circ}C$) during the growth period. Bulb/neck diameter ratio, over 2.0 a good indicator of development of bulb, increased rapidly at ambient $+2^{\circ}C$ temperature. This result suggests that extremely early-maturing onion (Allium cepa L. cv. Singsingball) could maintain the higher productivity and bulb quality at ambient $+2^{\circ}C$ temperature. On the contrary, $5^{\circ}C$ higher than atmospheric temperature shows negative effects on yields under a future climate change scenario.