• 제목/요약/키워드: Alternating Current

검색결과 391건 처리시간 0.026초

A New Overlap Current Restraining Method for Current-source Rectifier

  • Qin, Haihong;Liu, Qing;Zhang, Ying;Zhang, Xin;Wang, Dan
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.615-626
    • /
    • 2018
  • To ensure a DC current path and avoid large voltage overshoot of the DC-link inductor, alternating PWM pulses in the current-source rectifier should be supplemented by overlap time, which generates an overlap current and causes input current distortion. In this study, the influence of overlap time is illustrated by comparing the AC-side current before and after overlap time is added. The overlap current distribution caused by overlap time is discussed under different modulation carriers, including triangle carrier, positive-going carrier, and negative-going carrier. The quantitative relationship between the extra harmonics of the AC-side current and overlap time is based on the Fourier analysis. Based on the commutation analysis, a new carrier modulation scheme that can restrain overlap current is proposed. A 3 kW prototype is established to verify the effectiveness of the influence of overlap time and the proposed restraining modulation scheme.

Silicon carbide저항소자의 교류 비선형특성에 관한 연구 (An Experimental Research On Nonlinear Characteristics Of Disk-Type Siliconcarbide Resistors With The Sinusoidal Alternating Currents)

  • 조철;오명환
    • 전기의세계
    • /
    • 제21권2호
    • /
    • pp.25-33
    • /
    • 1972
  • The main focus of this paper is on the study of voltage-current characteristics in disk-type siliconcarbide resistors. For each of the 15 different sintering and other process conditions, 10 samples were prepared. Experiments performed with each sample consist of supplying sinusoidal AC current of a few miliamperes after conditioning-shots with 400ma. Experimental data were examined with regard to the relationship between the process conditions and the nonlinear resistivity. The examination suggests several possibilities of improving the nonlinlinear characteristics of siliconcarbide resistors while maintaining low resitance. One of those possible conditions is to sinter the powdered SiC and the binding materials approximately 2 hours in nitrogen. In addition to describing the nonlinear characteristics of siliconcarbide resistors, this paper also presents the distortion characteristics of current waves vs. the nonlinear exponent, n. Photographical results show that the more nonlinear characteristics samples have, the more distorted current waves are.

  • PDF

아조벤젠 유기단분자의 광제어에 관한 연구 (A Study on the Light Control of Azobenzene Organic Monolayers)

  • 김성진;정헌상;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 전자세라믹스 센서 및 박막재료 반도체재료 일렉트렛트 및 응용기술
    • /
    • pp.139-142
    • /
    • 2000
  • Displacement current was generated in the light stimulus. Solution of azobenzene molecules (8A5H) have to character trans-to-cis. The Maxwell displacement current measuring technique has been applied for the investigation of azobenzene organic thin films under alternating photoirradiation with ultraviolet($\lambda_1$) and visible($\lambda_2$) light. also, As laser beam(630~670nm) investigate light response. As result, ultraviolet($\lambda_1$) and visible($\lambda_2$) light see photoisomerization response, but laser beam not appear photoisomerization in current that differ wave range reagent.

  • PDF

부분공진형 고역률 승강압 AC-DC 컨버터 (A New partial resonant buck-boost AC-DC converter for high power factor)

  • 신현식;서기영;권순걸;곽동걸;이현우;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.512-515
    • /
    • 1994
  • This paper propose the high power factor and efficiency buck-boost AC-DC converter because the input current is made sinusoidal wave in single phase alternating current source. The proposed converter is able to minimize switching loss by the partial resonant switching which is for switching devices to operate the zero voltage switching (ZVS) or zero current switching(ZCS) without increasing their voltage and current stresses.

  • PDF

Decomposition Properties of Trifluoroiodomethane under Discharges and Interruptions

  • Cai, Fan-Yi;Tan, Dong-Xian;Zhou, Bai-Jie;Xue, Jian;Xiao, Deng-Ming
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2385-2391
    • /
    • 2018
  • This paper is devoted to detecting decomposition characteristics of Iodotrifluoromethane ($CF_3I$) under alternating current (AC) discharges or load current interruptions. The decomposition products are measured utilizing chromatography-mass spectroscopy. It is found that less than 1% $CF_3I$ gas decomposed after several interruptions at load current of 200 A or hundred times of AC discharges. However, under interruptions at a current of 400 A, more than 95% $CF_3I$ gas decomposed into carbon tetrafluoride ($CF_4$) and hexafluoroethane ($C_2F_6$). The equilibrium compositions based on Gibbs free energy minimization of $CF_3I$ was calculated to explain the decomposition mechanism.

교류용초전도연선의 교류전류열화현상의 이론적 검토 (Theoretical Evaluation of Degradation in Superconducting Multistrands for AC Use)

  • 오봉환;나완수;오상수;류강식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.76-78
    • /
    • 1993
  • When an alternating current is supplied to a super-conducting multi-stranded cable, the quench current value of the cable was observed to be less than the simple summation of individual quench current value of each strand. One of the causes for such a degradation was attributed to the nonuniform of the current distribution in multi-stranded cable due to magnetic mutual coupling among the strands. The degradation of the superconducting cable is evaluated theoretically by taking into account the magnetic coupling among the strands.

  • PDF

부분공진형 고역률 승강압 컨버터 (High power factor Buck-Boost converter with partial resonant circuit)

  • 서기영;권순걸;이현우;곽동걸;배성식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.126-128
    • /
    • 1993
  • Rectifiers of power conversion system are widely used condenser at input to be cheap and to be simple construction. But this method is produced harmonics of pulse at peak value of input AC voltage. The main circuit which make input current of a sinusoidal wave and improve power-factor is almost taken step-up converter. This paper is able to obtain high power-factor and efficiency because the input current is made sinusoidal wave in single phase alternating current(AC) source. Also the proposed converter is able to minimize switching loss by ZVCS(zero voltage switching and zero current switching).

  • PDF

저전류 영역에서 로고우스키 코일 특성 (Characteristics of Rogowski coil at Low Cutrrent Region)

  • 박정남;이강원;이청;김길수;박영국;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.47-50
    • /
    • 2001
  • Conventionally, air-cored Rogowski coil was designed for use as high alternating and transient current sensor without saturation caused by ferromagnetic material in its core. This paper investigated that Rogowski coil can be applied to low current measurement in 60Hz power line. Measured parameters R, L of coil were compared with theoretically calculated values. Output voltages crossed by Rogowski coil have shown some linearity according to input current(tens to thousands of amperes) passing through it. And also shielding effect for external noises was investigated for three cases.

  • PDF

Reliability Modeling of Direct Current Power Feeding Systems for Green Data Center

  • Choi, Jung Yul
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.704-711
    • /
    • 2013
  • Data center is an information hub and resource for information-centric society. Since data center houses hundreds to ten thousands servers, networking and communication equipment, and supporting systems energy saving is one of the hottest issues for green data center. Among several solutions for green data center this paper introduces higher voltage direct current (DC) power feeding system. Contrary to legacy alternating current (AC) power feeding system equipped with Uninterruptible Power Supply (UPS), higher voltage DC power feeding system is reported to be a more energy efficient and reliable solution for green data center thanks to less AC/DC and DC/AC conversions. Main focus of this paper is on reliability issue for reliable and continuous operation of higher voltage DC power feeding system. We present different types of configuration of the power feeding systems according to the level of reliability. We analyze the reliability of the power feeding systems based on M/M/1/N+1/N+1 queueing model. Operation of the power feeding system in case of failure is also presented.

Effect of form of applied current on the formation behavior of PEO films on Al6082 alloy

  • Moon, Sungmo;Kim, Juseok;Shin, Heon-Cheol
    • 한국표면공학회지
    • /
    • 제55권1호
    • /
    • pp.9-17
    • /
    • 2022
  • This work is concerned with the formation behavior of PEO (Plasma Electrolytic Oxidation) films on Al6082 alloy under the application of direct current (DC) and alternating current (AC) in an alkaline solution. Arc initiation voltage became much lower by the application of AC than DC, and arc initiation time became shorter under DC than AC. The number of pores present in the PEO films was much larger than that on the surface, irrespective of DC and AC. It was also found that the number of pores in the PEO films formed under AC was more than that under DC and the size of pores is smaller under AC than DC. During the formation of PEO films, a lot of heat was generated and solution temperature increased more rapidly under DC than under AC which is attributed to high PEO film formation voltage under DC than AC.