• 제목/요약/키워드: Alluvium

검색결과 128건 처리시간 0.024초

전도성 충적지반의 지질 및 하부 기반암 조사를 위한 지하레이다(GPR)의 적용 (Application of GPR Technology for Detecting Bedrock under Conductive Overburden and Geological Survey)

  • 윤운상;배성호;김병철;김학수
    • 터널과지하공간
    • /
    • 제5권2호
    • /
    • pp.114-122
    • /
    • 1995
  • The principle and applications of GPR(Ground Penetrating Radear) are familiar to engineering geologists and geophsicists as very attractive technique for continuous high resolution images of the subsurface. However, the main limitation of GPR is obviously related to presence of clayey or silty conductive soils, resulting in complete attenuation of radar signals. This difficulty gives hesitation for the exploration of the deeper targets for example detecting bedrock, particularly in Korean situation that most regions have conductive overburden. In order to prove usefulness of geological survey with GPR in that situation, the technique was tried to investigate depth of bedrock under thick conductive overburden and the other geolocgical informations for the constructionof foundation in the Dongbu apartment site, Kimhae. The reflection patterns on the processed GPR sections are well correlated with the geotechnical units-bedrock, alluvium, landfill unit and their internal layer-boundaries of boring data before GPR survey, except upper contact of bedrock. The isopach maps of the geotechnical units for the 3-D interpretations are made from GPR sections. The maps provided useful geological information that bedrock was distributed as plain and valley with 22~27m depth under alluvium unit (this depth is 5~8 m deeper than drill log) and sedimentary layers subsided and bended along growth fault with NNE strike/15$^{\circ}$SE dip in alluvium unit.

  • PDF

전기비저항 모니터링 방법을 이용한 충적층 지하수위 변동 감지 (Detection of Groundwater Table Changes in Alluvium Using Electrical Resistivity Monitoring Method)

  • 김형수
    • 지질공학
    • /
    • 제7권2호
    • /
    • pp.139-149
    • /
    • 1997
  • 전기비저항 모니터링을 이용하여 충적층 지하수위의 변동을 감지 할 수 있는지의 여부가 연구되었다. 연구는 유한요소법을 이용한 전기비저항 수치 모델링 시험과 20일간의 장기 양수 시험이 수행된 금강 정동리 지역의 현장 자료를 이용하여 수행되었다. 수치 모델링 시험 및 현장 자료 획득은 전극 기본 간격이 4m인 21개의 고정전극을 이용하였으며, 전극배열은 "변형 웨너 배열"과 쌍극자 배열을 이용하였다. 현장 장기 양수 시험에서 관측된 수위 변화를 단순화하여 지하 2차원 비저항 모델로 사용한 사용한 결과, 겉보기 전기비저항의 변화 양상은 수위 변화보다 둔감한 변화 양상을 보여 주며, 수위 변화가 있는 부분뿐만 아니라하부 결정질 기반암의 경계 부위에 해당하는 심도에서도 겉보기 비저항 장치가 변화하는 현상이 관측되었다. 이러한 수치 결과와 부합되는 결과가 실제 현장에서 획득된 겉보기 전기 비저항 단면에서도 나타났다. 수치 계산결과 및 현장 자료는 전기 비저한 모니터링이 지하수위 변동을 유무 감지하는데 유용하게 사용될 수 있음을 보여주었다. 그러나 겉보기 전기비저항 단면이 수위 변동량을 정량적으로 규명할 만큼의 뚜렷한 변화를 보여주지는 못하기 때문에 전기비저항 방법만으로 정략적인 수위변동을 감지하는데 한계가 있는 것으로 판단되었다. 이러한 지하 수위 변동량 등을 명확히 규명하기 위해서는 고해상도 탄성파 또는 지하레이다 탐사처럼 지하의 모습을 영상화 할 수 있는 지구물리 탐사법이 병행되는 것이 바람직하다.

  • PDF

지하수질에 따른 배관부식 상태와 이의 해결방안 연구

  • 김윤영;김정진;김형수;원종호
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 총회 및 춘계학술발표회
    • /
    • pp.263-266
    • /
    • 2002
  • The purpose of this study is to clarify the reasons of pipe corrosion and well clogging which are taken place in long term bank filtering and to establish countermeasure of them in the alluvium of Goryeong Gun, Dasan Myeon, Nakdong River It is believed that the scale inside the pipe is not caused by only iron hydroxides but compounds consisted with some carbonate and silicate minerals. For the removal of the scales, it is desirable to loosen the bonds of the scale itself by dissolving the carbonate and silicate minerals after detailed study of the scale compounds.

  • PDF

사대강유역의 지하수 (Ground water in the four major basins in Korea)

  • 최승일
    • 물과 미래
    • /
    • 제12권1호
    • /
    • pp.21-27
    • /
    • 1979
  • Ground water stored in the alluvium and the rocks provides the vase flow of the streams and can be withdraw from wells and infiltration galleries. And it is also recharge naturallyby precipitation. The amount of ground water in the four major basins it is estimated to be about 137,000 million cubiv meters(Table1), while nationwide ground water storage to be about 232,000 million cubic meters. The estimation of storage volume has been made on the basis of assumed thickness of the saturated zone of the different rocks and assumed porosities of those rocks. The values of the porosity of alluvium and saprolite were assumed to be 25% and 40% respectivvely which are based on tests made of similar materials in Georgia, U.S. The volume of water in storage is believed to be a conservative estimate. Detailed geologic and hydrologic investigation should be made where and when water resources are needed.

  • PDF

금강 부여 군수리 충적 대수층 조사를 위한 고해상도 지구물리탐사 - 탄성파 탐사 및 GPR 조사를 중심으로 -

  • 김형수;서만철;이철우;진세화
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 총회 및 춘계학술발표회
    • /
    • pp.287-291
    • /
    • 2003
  • To delineate the internal structures of alluvial aquifer, high resolution seismic and GPR methods were adopted in Buyeo Gunsu-Ri area. The result of seismic refraction survey shows the water table of the aquifer and the result of seismic reflection reveals the basement and somewhat dominant internal structures of alluvial aquifer. The internal heterogeneity due to variations in channel behavior can be delineated using GPR survey. GPR profiles for the point bar deposits near Buyeo county reveals two different stratigraphic units the lower inclined heterogeneous strata and the upper horizontally stratified strata. According to the increase of demand for water resource using artificial recharge in alluvium, it is believed that the information acquired by high resolution geophysical methods will have an important roles for the effective and sustainable development and usage of groundwater in alluvial aquifer.

  • PDF

난지도에 인접한 한강변에서의 쌍극자-쌍극자 전기탐사 (Dipole-Dipole Resistivity Survey on the Side of Han River near Nanjido Landfill)

  • 이기화;권병두;오석훈;김차섭
    • 자원환경지질
    • /
    • 제29권3호
    • /
    • pp.335-343
    • /
    • 1996
  • The dipole-dipol electrical resistivity survey was conducted to investigate the probable contamination of the Han river by leachate from the near-by Nanjido Landfill. The survey line of 3 km was set along the unpaved road toward the Han river. For the convenience of the field work, the survey line was divided into four segments. The complete two-dimensional resistivity section was constructed by connecting the inversion result of each segment. Gravity survey was also carried out along the profile parallel to the resistivity line. Near surface resistivity generally appeared to be of very low value in most part of the survey area and the boundary between the alluvium layer and underlying basement rocks is well discriminated on the resistivity section. These results agree well with those of the preceding Schlumberger depth sounding made at adjacent area by Lee and fun (1995). The variation of thickness of the alluvium layer delineated by gravity anomaly profile also correlates well with the result of the resistivity survey on the qualitative basis. The problem of contamination by leachate from the Nanjido Landfill, where various waste materials have been dumped without any proper treatment facilities, has been remains unsolved yet. Therefore, we present the most probable passages of leachate flow based on the survey results and have briefly discussed about measure for contamination control. Considering the thickness of alluvium and the possible existence of fractured zone, the middle point between 1st and 2nd landfill and the midst of 1st landfill are the most hazardous regions to make leachates flow into the Han river. Since large amounts of leachates are observed from the test wells located on the lines extending from the border between the 1st and 2nd landfill and the middle of the lst landfill, contamination protection barriers are strongly recommended near these regions.

  • PDF

충적층 조사를 위한 모래와 점토의 유도분극 특성 고찰 (A study on induced polarization characteristics of sand and clay for alluvium investigation)

  • 최상혁;김형수;김지수
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2008년도 공동학술대회
    • /
    • pp.179-184
    • /
    • 2008
  • 충적층 구성 물질 중 포화된 실트 혹은 점토층은 상대적으로 낮은 전기비저항 값을 나타낸다. 낮은 전기비저항 값은 이 지층을 투수성이 높은 대수층으로 오인하는 문제를 발생시킨다. 이러한 문제를 극복하고 충적층 내 포화된 실트 혹은 점토층과 모래 혹은 자갈 대수층을 구분하기 위해 전기비저항 조사와 함께 유도분극 조사를 활용하는 방안을 검토하였다. 본 연구에서는 우선, 실내 실험을 통해 충적층 구성 물질별 전기비저항(resistivity)과 충전성(chargeability)을 조사하였고, 비분극 전극을 활용한 현장 수직 전기비저항/유도분극 조사를 수행하였다. 실내 실험을 통해 모래/점토 혼합층에서 점토함량이 증가함에 따라 비저항은 낮아지고, 충전성은 높아짐을 확인하였다. 이러한 실험 결과를 바탕으로 강변여과 현장에서 전기비저항/유도분극 조사를 수행하였다. 자료의 정량적 해석을 통해, 낮은 비저항과 낮은 충전성을 갖는 지층이 상대적으로 투수성이 우수하고 지하수 산출성이 높은 충적 대수층에 해당되는 것으로 최종 해석하였다.

  • PDF

미국 아리조나 투산과 치리카와 지역의 지형발달 (Geomorphic Development of Tucson and Chiricahua in Arizona, U.S.A)

  • 박희두
    • 한국지형학회지
    • /
    • 제15권2호
    • /
    • pp.1-9
    • /
    • 2008
  • 본 연구지역은 악지를 이루고 있는 산지와 그 계곡에 발달한 충적평야, 하천을 중심으로 발달하는 하성단구, 하성단구와 산지 사이의 충적선상지로 구성되었다. 화산 폭발에 의한 화산회층이 쌓여서 형성된 치리카와는 응회암이 침식작용을 받아 기암괴석을 노출시켰다. 윌콕스 플라야는 현재보다 기후가 습윤했던 플라이스토세에 $32km^2$ 정도의 호수가 존재했던 곳으로 칼슘과 나트륨, 칼륨 같은 염이 집적된 알카리각이 드러나기도 한다. 윌콕스 주변의 과거 호안은 사구가 발달하였다. 이곳의 계곡은 주변의 산지에서 공급된 실트와 점토, 모래, 역으로 이루어진 약 700m 두께의 퇴적층으로서 플라이오세와 플라이스토세 화석이 다양하게 발견된다. 드래군 산맥 기슭에는 페디멘트가 충적지와 파상으로 만난다. 주변에 산재하는 거대한 원력은 박리작용에 의한 파쇄작용과 박판작용의 결과이다. 투산은 두께 약 7,000ft. 정도의 충적평야이다. 본 연구지역은 화산, 단층, 침식, 퇴적 등의 작용에 의하여 형성된 지형이다.

상시미동 HVSR 기법 적용을 통한 포항지역의 충적층 및 연일층군의 층후 분석 (Thickness Analysis of the Alluvium and Yeonil Group in Pohang Area through the Microtremor HVSR Techniques)

  • 김정현;기정석;노영화
    • 지질공학
    • /
    • 제31권2호
    • /
    • pp.211-222
    • /
    • 2021
  • 포항지진은 2017년 규모 5.4의 포항시 북구 북쪽 7.5 km 부근에서 발생하였다. 지진피해가 크게 발생한 경상북도 포항 북구 지역의 상시미동의 특성을 알아보기 위하여 총 39 지점에 상시미동 자료를 취득하여 수평 대 수직 스펙트럼 비율(Horizontal to Vertical Spectral Ratios, HVSR) 분석연구를 실시하였다. 상시미동은 지역에 따라 각각 다르므로 상시미동을 조사해 그 지역의 공명주파수를 취득한다. 층후 분석을 위해서는 기반암까지의 전단파 속도(Vs) 구조 및 특성을 분석하여 공명주파수를 인근의 시추자료와 대비하여 수평 대 수직 스펙트럼 비율(Horizontal to Vertical Spectral Ratios, HVSR) 분석기법이 일치하는지 비교하였다. 충적층의 공명주파수 1.3 ± 0.07 Hz, 연일층군의 공명주파수 0.69 ± 0.22 Hz로 F0 = Vs/4H를 이용하여 층후를 구하면 충적층은 26~30 m, 연일층군은 170~250 m로 인근 시추자료와 비교하여 대체로 일치한 것으로 분석하였다.

전기비저항, 탄성파 그리고 GPR 탐사를 활용한 충적층 탐사 (The Investigation of Alluvium by Using Electrical Resistivity, Seismic Survey and GPR)

  • 박충화;원경식;변지환;민대홍;윤형구
    • 한국지반공학회논문집
    • /
    • 제29권9호
    • /
    • pp.17-29
    • /
    • 2013
  • 물리탐사 기법은 적은 비용으로 광범위한 영역을 간접적으로 해석할 수 있는 장점이 있어 다양한 분야에 활용성이 높다. 본 논문의 목적은 물리탐사 기법을 충적층 평가에 적용하고 그 결과를 고찰하고자 하는 것이다. 이번 연구에서는 다양한 물리탐사 방법 중 활용성이 높은 탄성파 탐사, 전기비저항 탐사 그리고 레이더 탐사를 활용하였다. 또한 시추조사도 함께 실시하여 측정한 물리탐사 데이터의 신뢰성을 검증하였다. 발신 에너지원의 종류에 따른 탄성파 탐사의 해상도 비교를 위해 햄머와 땅속발파(sissy)로 나누어 실험결과를 비교하였으며, 전기비저항 탐사는 전극 길이, 형상 그리고 배열방법을 변화시켜 비교 실험을 통해 나타나는 결과의 해상도를 비교 및 검증하였다. 레이더 탐사는 중심주파수 270MHz를 활용하여 획득한 결과를 시추조사 데이터와 비교하였다. 실험결과 탄성파 탐사는 땅속발파를 활용하였을 경우 큰 에너지원이 발생하여 가진원 Hammer보다 굴절파 감쇄 현상이 적게 발생하여 해상도가 높게 나타났으며, 지하 구조는 시추자료와 유사하게 나타났다. 전기비저항 탐사 결과는 접지비저항 변화가 작은 비분극 전극과 충적층의 경계를 신뢰성 있게 파악 할 수 있는 슐럼버져 배열 방법에서 해상도 높은 결과가 나타났으며, 레이더 탐사는 심도의 제약이 많아 해상도가 많이 부족한 것으로 나타났다. 따라서 본 연구는 물리탐사 기법을 활용하여 충적층 탐사에 적용한 결과로 추후 충적층 탐사에 활용성이 높을 것으로 판단된다.