• Title/Summary/Keyword: Allowable Error

Search Result 168, Processing Time 0.025 seconds

Static Load Test for Verification of Structural Robustness of Composite Oxidant Tank for Space Launch Vehicle (우주발사체용 복합재 산화제탱크 구조 강건성 검증을 위한 정하중 시험)

  • Kim, Hyun-gi;Kim, Sungchan
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.5
    • /
    • pp.98-105
    • /
    • 2021
  • This study presented the results of the static load tests conducted to verify the structural robustness of the composite oxidant tank for a space launch vehicle. First, we introduced the test equipment used in the static load test of the composite oxidant tank, and then described the test requirements that the composite oxidant tank must satisfy. In addition, we presented a test set-up diagram consisting of the static load test fixture, hydraulic pressure, control equipment, and data acquisition equipment, and the load profile of the static load test of the composite oxidant tank consisting of shear, equivalent compression, bending, and combination tests. As a result of load control, we verified the reliability of this test by showing the errors between the input load and the feedback load in each channel according to the increase of the test load, and the feedback error between the channel A and channel B of load cell in each load actuator. As a result of the static load test, the load of the actuator was properly controlled within the allowable error range in each test, and we found that the test specimen did not cause damage or buckling that causes significant structural defects in the required load.

Distribution Characteristics of Bending Properties for Visual Graded Lumber of Japanese Larch (육안등급으로 구분된 낙엽송 제재목의 휨성능 분포 특성)

  • Lee, Jun Jae;Kim, Gwang Chul;Kim, Kwang Mo;Oh, Jung Kwon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.72-79
    • /
    • 2003
  • In reliability based design(RBD) method, the distribution characteristics of mechanical properties of material are basic input variable. Therefore, distribution type and parameters of mechanical properties should be determined accurately. Until now, the properties were derived from tests with small, clear specimens. However, the test conditions should emulate as nearly as possible the way in which the timber would be used in practice and the test results should, as closely as possible, reflect the structural end use conditions to which the timber products would be subjected. In this study, structural timbers (38mm by 140mm, 3.0m long) were graded by visual assessment of growth characteristics and defects. And then bending tests were conducted on 498 structural size timbers. For each grade, the distribution type and the parameters of mechanical properties were determined for each grade. For the determination of best-fit distribution type, comparing of square error between distribution types and KS test were conducted. Best-fit distribution type of bending strength(MOR) is weibull distribution for all grade. In case of MOE, normal distribution is best-fit.

Structural Static Test of Pylon for External Attachment Separation Load (외부장착물 분리하중에 대한 파일런 구조 정적시험)

  • Kim, Hyun-gi;Kim, Sungchan;Hong, Seung-ho;Choi, Hyun-kyung;Cho, Sang-hwan;Park, Hyung-bae
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.1
    • /
    • pp.104-109
    • /
    • 2022
  • The bomb rack unit (BRU) installed inside the pylon serves to fix external attachments such as external fuel tank or external weapon, and also serves to separate external attachments in case of emergency. In particular, the load generated when the external attachment is separated from the BRU is called the punching load. In this study, we present the results of a structural static test performed to verify the structural integrity of the pylon under the BRU punching condition acting on it. In the structural static test report, we present the implementation method for the separation load of the external attachment and the test profile for the BRU punching load condition, and compared the error between the load input signal and the feed-back signal to determine the appropriateness of load control in each test. Furthermore, we compared the strain results obtained in the numerical analysis and structural test at the main positions of the specimen. As a result, it was shown that the load of the actuators were properly controlled within the allowable error range in each test, and the numerical analysis effectively predicted the test result. Finally, through structural static tests conducted by design limit load and design ultimate load, we verified that the aircraft pylon dealt with in this study has sufficient structural strength for external attachment separation condition.

Studies on the Estimation of Annual Tree Volume Growth for the Use as Basic Data on the Plan of Timber Supply and Demand in Korea - The Sub-sampling Oriented - (우리나라 목재수급계획(木材需給計劃)의 기초자료(基礎資料)로 활용(活用)키 위한 연간(年間) 임목성장량(林木成長量)의 추정(推定)에 관한 연구(硏究) - 부차추출법(副次抽出法)을 중심(中心)으로 -)

  • Lee, Jong Lak
    • Journal of Korean Society of Forest Science
    • /
    • v.61 no.1
    • /
    • pp.37-44
    • /
    • 1983
  • This study was to estimate total annual volume growth by the measurement of mean tree growth during the last 10 years. Surveyed Forest stand was the second block (20.80 ha.)of Kyung Hee University Forests located at San 58 and 64, Gaegok-Ri, Gapyung-Yeup, Gapyung-Goon, Kyunggi province in Korea. The stand was mainly composed of uneven-aged Pinus densiflora and the estimation of tree volume was conducted by taking the cores at the D.B.H. of the sample tree which was selected by sub-sampling. The results obtained were as follows; 1) The regression between the diameter (D) and diameter growth ($\hat{I}$) was $\hat{I}=0.5499+0.0101D$. 2) The estimated equation of confidence interval for the diameter growth was $S^2{\hat{I}}=0.00817(0.09538-0.00952D+0.00027D^2$) 3) The equation for estimating tree height (H) from diameter was $H=1.32376D^{0.77958}$ 4) The equation for estimating tree volume from diameter and height $V=0.0000622D^{1.6918}H^{1.1397}$ 5) Total annual tree volume growth was $5.4041m^3/ha$, and ranged from 5.6131 to $5.1984m^3/ha$. 6) Annual growth rate of total tree volume and its error were 8.8% and 3.9%, respectively. The annual volume growth per tree for any districts can be estimated by this method, and the annual volume growth will be successfully predicted. Because of poor forest growing stock in Korea, annual amount of allowable cut should not exceed annual tree volume growth for better forest management. Accordingly, annual amount of allowable cut should be either equal to or less than annual tree volume growth for the balanced establishment between timber supply and demand in Korea. Demand shortage will be substituted with imported timber. Such plans enable Korean Government to develop a better policy of forest resources management.

  • PDF

UAV Photogrammetry Accuracy Analysis at Marine Using Arbitrary Reference Points (임의의 기준점을 이용한 해상에서의 UAV 사진측량 정확도 분석)

  • Oh, Jae Hyun;Kim, Byung Woo;Hwang, Dae Young;Hong, Soon Heon
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.4
    • /
    • pp.39-45
    • /
    • 2016
  • In this study, with arbitrary reference points on the water, photogrammetry accuracy analysis was conducted using unmanned aerial vehicle(UAV). A small reservoir is a research area, and twenty buoys were used as arbitrary reference points. Errors of location coordinate were identified with control of amounts of used reference points. cases are categorized by index scores per photos. Accuracy of X is 0.141m~0.166m and accuracy of Y is 0.136m~0.241m. Considering that allowable error for the maritime boundary survey is ${\pm}2m$, it is possible to get the accuracy data available for the photogrammetry of UAV using an reference point. In addition, the coefficient of correlation between the number of reference points per unit and number of buoys used as reference point and the ratio of the reference point per square measure, and percentage of buoys used as reference point and the coefficient of x and y were performed. Each element, x, and y showed a strong correlation and the coefficient of number of buoys used as reference point was irrelevant. The results of this correlation analysis can be analyzed that the number of reference points used in each picture is greater than the actual number of reference points used in location accuracy.

Parcel Boundary Demarcation in Residential Area Using High Resolution Aerial Images (고해상도 항공영상을 이용한 주거지역 필지경계 설정에 관한 연구)

  • Park, Chiyoung;Lee, Jaeone
    • Spatial Information Research
    • /
    • v.23 no.1
    • /
    • pp.59-68
    • /
    • 2015
  • As part of an effort to leap smart cadastre system by doing rearrangement of various mismatches in the land register, the cadastre renovation project is being recently conducted. In response to this demand, this paper proposes an image-based rapid parcel boundary demarcation plan using the high resolution aerial image with a GSD (Ground Sample Distance) of 5cm that matches to real ground boundary situation in residential area. To review the feasibility and accuracy of this proposed methodology, we compared the accuracy of parcel boundary point and parcel area extracted from the digital stereo plotting on the basis of results of cadastral boundary surveying and land register over the selected two test areas. The comparative accuracy result of all boundary points by digital stereo plotting is satisfied with accuracy requirement according to the criteria of the enforcement regulation of cadastral surveying, whereas it exceeded allowable error of ${\pm}0.07m$, more strictly specified in the Special Act on Cadastral Renovation. And about 20% of the total 70 parcels extracted by digital plotting are out of area tolerance in Jecheon study area, and 10% of the total 19 parcels in Suwon study area. The parcels exceeding accuracy limit are mostly due to the occlusion caused by building roof or eaves, and the obstacles such as trees existing on the boundary. Furthermore, an object identification is impossible in image because of vague boundary reference in case of nonexistence of man-made structures or natural features. Therefore, the utilization of boundary identification stickers is recommended as a solution for these types of land parcel.

An analysis of problems and countermeasures in the installation of plastic greenhouse on reclaimed lands (간척지에 플라스틱 온실 설치 시의 문제점 분석 및 개선방안)

  • Yu, In-Ho;Ku, Yang-Gyu;Cho, Myeong-Whan;Ryu, Hee-Ryong;Moon, Doo-Gyung
    • Korean Journal of Agricultural Science
    • /
    • v.41 no.4
    • /
    • pp.473-480
    • /
    • 2014
  • Upon setting up a dedicated plastic greenhouse for tomato cultivation developed by the Rural Development Administration on the Gyehwa reclaimed land, this study was aimed at analyzing the problems can be occurred in the installation of plastic greenhouse on reclaimed lands as well as finding out solutions for improvement. A relatively cheaper wooden pile was used in the installation in order to supplement the soft ground conditions. Based on the results of ground investigation of the installation site, both the allowable bearing capacity and pulling resistance of the wooden pile with a diameter of 150 mm and a length of 10 m were computed and came out to be 30.645 kN. It was determined that the values were enough to withstand the maximum compressive force (17.206 kN) and the pullout force (20.435 kN) that are generally applied to the greenhouse footing. There are three problems aroused in the process of greenhouse installation, and the corresponding countermeasures are as follow. First, due to the slightly bent shape of the wooden pile, there were phenomenon such as deviation, torsion, and fracture when driving the pile. This could be prevented by the use of the backhoe (0.2) rotating tongs, which are holding the pile, to drive the pile while pushing to the direction of the driving and fixing it until 5 m below ground and applying a soft vibrating pressure until the first 2 m. Second, there exists a concrete independent footing between the column of the greenhouse and the wooden pile driven to the underground water level. Since it is difficult to accurately drive the pile on this independent footing, the problem of footing baseplate used to fix the column being off the independent footing was occurred. In order to handle with this matter, the diameter of the independent footing was changed from 200 mm to 300 mm. Last, after films were covered in the condition that the reinforcing frame and bracing are not installed, there was a phenomenon of columns being pushed away by the strong wind to the maximum of $11m{\cdot}s^{-1}$. It is encouraged to avoid constructions in winter, and the film covering jobs always to be done after the frame construction is completely over. The height of the independent footing was measured for 9 months after the completion of the greenhouse installation, and it was found to be within the margin of error meaning that there was no subsidence. The extent to the framework distortion and the value of inclinometers as well showed not much alteration. In other words, the wooden pile was designed to have a sufficient bearing capacity.

Evaluate the Accuracy of Drone Photogrammetry Surveying Using Water Reference Points (수상기준점을 활용한 드론 사진측량의 정확도 평가)

  • Kim, Byungwoo;Hong, Soonheon;Oh, Jaehyun;Hwang, Daeyoung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.2
    • /
    • pp.445-449
    • /
    • 2017
  • Most studies using drone is confined utilization on the ground and regulation. The drone in the water is rarely used in hydrographic surveying because of the limit of flight time and image matching. This paper is the basic research for drone hydrographic photogrammetry. The accuracy of hydrographic photogrammetry, using buoys for water reference point, was evaluated. The accuracy is influenced by the accuracy of the water reference points like the photogrammetry. The position of water reference points set up on water, keep on changing due to various environmental factors such as wind speed and water velocity. The position continuously changed of the water reference points were measured 3 times using Total Station and VRS. Experiments were conducted at two reservoirs in Gimhae City, and the accuracy of the manual image matching using the water reference points is 40 cm and 80 cm. Allowable accuracy of the ocean boundary survey is ${\pm}2m$, the results of this study are fully available. The maximum position error of the water reference point for ensuring accuracy within ${\pm}2m$ is 1.8 m.

Temperature Prediction of Underground Working Place Using Artificial Neural Networks (인공신경망을 이용한 심부 갱내온도 예측)

  • Kim, Yun-Kwang;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.17 no.4
    • /
    • pp.301-310
    • /
    • 2007
  • The prediction of temperature in the workings for the propriety examination for the development of a deep coal bed and the ventilation design is fairly important. It is quite demanding to obtain precise thermal conductivity of rock due to the variety and the complexity of the rock types contiguous to the coal bed. Therefore, to estimate the thermal conductivity corresponding to this geological situation and complex gallery conditions, a computing program which is TemPredict, is developed in this study. It employs Artificial Neural Network and calculates the climatic conditions in galleries. This advanced neural network is based upon the Back-Propagation Algorithm and composed of the input layers that are acceptant of the physical and geological factors of the coal bed and the hidden layers each of which has the 5 and 3 neurons. To verify TemPredict, the calculated result is compared with the measured one at the entrance of -300 ML 9X of Jang-sung production department, Jang-sung Coal Mine. The difference between the results calculated by TemPredict ($25.65^{\circ}C$) and measured ($25.7^{\circ}C$) is only $0.05^{\circ}C$, which is less than the allowable error 5%. The result has more than 95% of very high reliability. The temperature prediction for the main carriage gallery 9X in -425 ML under construction when it is completed is made. Its result is $28.2^{\circ}C$. In the future, it would contribute to the ventilation design for the mine and the underground structures.

Study on Coordinate Transformation of Railroad Central Linear-line Using the Railroad Reference Points (철도기준점을 이용한 철도중심선형 좌표변환에 관한 연구)

  • Moon, Cheung-Kyun;Heo, Joon;Kang, Sang-Gu;Kim, Il-Joo;Park, Jae-Hong;Kim, Sung-Hoon
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.6
    • /
    • pp.685-691
    • /
    • 2007
  • In this paper through Honan high-speed railroad which is planned with the north and south axis, we will verify the feasibility of the coordinate conversion using railroad control points after regarding current planned-railroad as the linear central axises. From analysis, distortion of Y axis varies 21 cm to 40 cm diminishing to a gentle straight line, distortion of X axis varies 14 cm to 29 cm. Through a revision, the deviation value between the coordinates were 6 mm to 9 mm and it satisfied the allowable error of national geographic information institute which is following ITRF (International Terrestrial Reference Frame) and cadastral boundary survey (10 cm). consequently the coordinate conversion is possible using railroad control points as common control points.